manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ventair
  6. •
  7. Fan
  8. •
  9. Ventair GLA1203WH User manual

Ventair GLA1203WH User manual

Glacier DC Ceiling Fan INSTRUCTION MANUAL
Images are for reference only and may vary slightly from actual product.
Ceiling Fan Installation Manual Rev 1.2
GLA1203WH, GLA1203WH-L, GLA1303WH, GLA1303WH-L
1
2
33
2
1
3 3
Please Note: Check for any damage to the fan prior to installation. Physical damage
such as marks and scratches are not overed by the in home warranty. In this case,
please contact Ventair to discuss replacement parts.
Remote control x 1 Remote control x 1
(2 pcs R03 1.5V AAA Batteries included.
Wood Screws 3.5 x 20mm)
(2 pcs R03 1.5V AAA Batteries included.
Wood Screws 3.5 x 20mm)
GLACIER DC WITHOUT LIGHT GLACIER DC WITH LIGHT
(M5 x 20mm) (M5 x 20mm)
Insert the blade screw, being careful not to over-tighten
BEAM
MUST BE
ABLE TO
SUPPORT UP
TO 20KG
NOTE: THIS PICTURE IS FOR ILLUSTRATIVE PURPOSES ONLY AND
DOES NOT REPRESENT THE ACTUAL BRACKET.
3. Slide the motor housing canopy downward until covering the motor.
Motor housing canopy
Slot
Blade Screw
Secure the safety wire
using the designated
screw point on the hang
bracket or other secure
point such as ceiling joist.
Fig 4
Highest Point
NOTE: Glacier DC is a Class I electrical product.
(
(Fig. 3)
• Slide the canopy upwards into position over the
mounting bracket then turn counter clockwise to
twist lock into position. Ensure all 4 tabs on the
mount bracket are located correctly into the slots
on the canopy. Canopy should be sitting approx.
-6mm off the ceiling.
• Ensure all wires are tucked neatly
into canopy taking care not
to cause damage.
- 3mm off the ceiling.
Please Note: Ensure the Canopy
has xed fully into position by twisting rmly.
and 7.2
Twistlock Canopy
Please note: The Glacier DC ‘Remote Handset’ cannot be used either simultaneously,
or in conjunction with, a ‘Wall Controller’ (DC wall Controller available seperately)
Fan Models with Light
The Glacier DC remote control comes pre-paired at the factory and is ready to
1. Using 1 remote handset to control 2 or more Glacier DC Ceiling fans
3. Replacing an old or damaged handset
If you are replacing a handsset only (not the receiver), the repairing process
(point 1) will need to be performed before operation of the fan is possible.
2. Loss of function or control between hand piece and receiver
Try the re-pairing process as outlined above (point 1)
Try pairing a hand piece from a different fan as outlined above (point 1).
If the problem persists, call Ventair technical support on 1300 665 926.
Turn the isolation switch on for the 1st fan and within 20 seconds press and hold
on the remote for 3 seconds. Remote should be paired, check fan functions.
Troubleshooting - Glacier DC
Q) One remote is controlling multiple fans, how do I x this?
A) This can be xed by re-pairing each fan one at a time:
Turn all fans you wish to separate off at the isolation switch leave off for a
minimum of 1 minute.
Repeat the above steps with next fan ensuring the previous fan is left on at
the isolation switch.
NOTE: Each fan must have its own isolation switch as per the instructions on page 2 and the diagram
on page 7. Please contact your installing electrician to rectify if this is not the case.
10
Fan Operation:
Glacier DC has been designed to optimise airow with minimal amount of energy usage.
A ceiling fan rotates much slowly than a traditional style wall, pedestal or desk fans; ceiling
fans cool people effectively by introducing slow movement, with high airow into otherwise
still, hot air of a room, creating a natural evaporative cooling effect. Fans never actually cool
air, like air conditioning equipment, but use signicantly less power.
Normal Wear and Tear
Over time, moving parts may become slightly loose or worn creating small increases in noise
or movement. Fan operation may also be effected by accidental contact by person or foreign
objects. These conditions are not covered under warranty, but a little care and maintenance
can reduce or prevent these problems from arising.
Night Noise
All electric motors, including fan motors make some noise, however the Glacier DC fan motor
is not susceptible to the noise problems that are commonly experiences with typical Higher
wattage, heavier AC type ceiling fan motors. The Glacier DC range are one of the quietest
fans available and are ideal for all areas of the home especially bedrooms where noise is a
crucial consideration.
GLA1203WH
GLA1203WH-L
GLA1303WH
GLA1303WH-L
220-240 VAC
220-240 VAC
220-240 VAC
220-240 VAC
26W 3.48
3.84
3.53
3.91
26W
26W
26W
11
• If you suspect faults relating to installation, contact your installer to rectify.
• If you suspect there to be a manufacturing defect, lodge a warranty by visiting
www.ventair.com.au/warranty or contact Ventair support on 1300 665 926
You will need to provide the following information:
• The name and contact details of the licensed electrician/installer.
• The brand, model number and serial number (on motor housing).
• The date and place of purchase of the unit.
• The owners name, address and telephone contact numbers.
• The nature of the fault.
The customer will not hain the benet of this warranty without making a claim with
Ventair. This warranty is not valid if any repairs or replacement is undertaken without the
prior approval of Ventair.
Please see www.ventair.com.au/warranty for terms and conditions.

This manual suits for next models

3

Other Ventair Fan manuals

Ventair WAL75-DC User manual

Ventair

Ventair WAL75-DC User manual

Ventair SPINIKA Series User manual

Ventair

Ventair SPINIKA Series User manual

Ventair SPYDAEC SPYEC1253WH User manual

Ventair

Ventair SPYDAEC SPYEC1253WH User manual

Ventair HARMONY II Series User manual

Ventair

Ventair HARMONY II Series User manual

Ventair GYRO 250 Installation guide

Ventair

Ventair GYRO 250 Installation guide

Ventair ROYALE DC Series User manual

Ventair

Ventair ROYALE DC Series User manual

Ventair MANROSE SIERRA MR2DXWH User manual

Ventair

Ventair MANROSE SIERRA MR2DXWH User manual

Ventair PRO-V PVPX200WH User manual

Ventair

Ventair PRO-V PVPX200WH User manual

Ventair VWF150AS Assembly instructions

Ventair

Ventair VWF150AS Assembly instructions

Ventair WAL45-DC User manual

Ventair

Ventair WAL45-DC User manual

Ventair GYRO 200 Installation guide

Ventair

Ventair GYRO 200 Installation guide

Ventair Stanza STA1203WH User manual

Ventair

Ventair Stanza STA1203WH User manual

Ventair MALIBU Series User manual

Ventair

Ventair MALIBU Series User manual

Ventair STANZA STA1203WH-LR User manual

Ventair

Ventair STANZA STA1203WH-LR User manual

Ventair Orbital 45 User manual

Ventair

Ventair Orbital 45 User manual

Ventair PRO-V Slimline VSLF100 Assembly instructions

Ventair

Ventair PRO-V Slimline VSLF100 Assembly instructions

Ventair DC 3 Series User manual

Ventair

Ventair DC 3 Series User manual

Ventair MALIBU MAL1404WH User manual

Ventair

Ventair MALIBU MAL1404WH User manual

Ventair Z564EXTSS User manual

Ventair

Ventair Z564EXTSS User manual

Ventair SPYDA SPY903NWH User manual

Ventair

Ventair SPYDA SPY903NWH User manual

Ventair Mixflow Assembly instructions

Ventair

Ventair Mixflow Assembly instructions

Ventair Brook 4 Installation guide

Ventair

Ventair Brook 4 Installation guide

Ventair FAN0530 User manual

Ventair

Ventair FAN0530 User manual

Popular Fan manuals by other brands

Westinghouse Magnolia owner's manual

Westinghouse

Westinghouse Magnolia owner's manual

Delta Electronics BFB0405HE Dimensions and installation information

Delta Electronics

Delta Electronics BFB0405HE Dimensions and installation information

NuTone 758 Specification sheet

NuTone

NuTone 758 Specification sheet

Monte Carlo Fan Company 3SY52 D Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3SY52 D Series Owner's guide and installation manual

Broan HRVH100S installation guide

Broan

Broan HRVH100S installation guide

Scarlett Comfort SC-SF111B16 instruction manual

Scarlett

Scarlett Comfort SC-SF111B16 instruction manual

Intertec Data Systems HT-ExVENT operating instructions

Intertec Data Systems

Intertec Data Systems HT-ExVENT operating instructions

Duka pro multi User and installation guide

Duka

Duka pro multi User and installation guide

PAX Retro Basic User and installation guide

PAX

PAX Retro Basic User and installation guide

Borg W2100R owner's guide

Borg

Borg W2100R owner's guide

Kruger APL Series General instructions

Kruger

Kruger APL Series General instructions

Caframo 797CA-GBX Instructions for use

Caframo

Caframo 797CA-GBX Instructions for use

MIA VLO 6010 manual

MIA

MIA VLO 6010 manual

Craftmade Envy EVY60 installation guide

Craftmade

Craftmade Envy EVY60 installation guide

Maico PP 45 O operating instructions

Maico

Maico PP 45 O operating instructions

DCG CLIMA VE1462TT instruction manual

DCG

DCG CLIMA VE1462TT instruction manual

Bionaire BT14 instruction manual

Bionaire

Bionaire BT14 instruction manual

Monsoon MON-MEVDC400 quick start guide

Monsoon

Monsoon MON-MEVDC400 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.