manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ventair
  6. •
  7. Fan
  8. •
  9. Ventair MANROSE SIERRA MR2DXWH User manual

Ventair MANROSE SIERRA MR2DXWH User manual

HEATFLOW Bathroom Heater/Exhaust/Light 204154/204155
HEATFLOW Bathroom Heater/Exhaust/Light 204154/204155
INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE 435 x 255 mm
INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE 435 x 255 mm
Please read these instructions
Thank you for purchasing your new EGLO Bathroom Heater/Exhaust/Light.
To ensure a safe and successful installation, please make sure to read this manual,
ensure it is on hand for your installer to refer to and keep in a safe place for future
reference.
For your safety
1. ALL electrical work should only be carried out by a licenced electrical contractor
in accordance with AS NZS 3000.
2. This appliance is not intended for use by persons (including children) with
reduced physical, sensory, or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
the use of the appliance by a person responsible for their safety.
3. Before commencing any electrical work, ensure the power is disconnected
and/or the mains switched off at the power supply.
4. This product has been designed to operate on a nominal supply voltage of 230
-240V AC.
5. The Bathroom Heater/Exhaust/Light unit must be earthed.
6. Disconnection may be achieved by having the plug accessible, or by
incorporating a switch into the fixed wiring in accordance with wiring rules.
The Bathroom Heater/Exhaust/Light must be isolated by means of a plug or all-
pole disconnection switch with a contact separation of at least 3mm in each
pole.
7. Use the Instant Heat only as described in this instruction, other use may cause
fire or electric shock.
8. This product has been designed for INDOOR domestic or similar uses and is not
suitable for a commercial installation. It is not suitable for use in an environment
heavily-laden with dust and/or corrosive areas. Under these conditions the life of
the fan motor can be significantly reduced.
9. The bulbs are hot when in use. Do not touch the infrared bulbs with any part of
your body when in use. Allow all bulbs to cool sufficiently before touching or
replacing.
10. The bulbs on this product should be tightened until fit is secure. Over
tightening may damage the bulbs and under tightening may result in hot
joints.
11. This product contains no serviceable parts and no attempt should be made to
repair this product.
12. Regular cleaning of dust and contaminants should be done with ONLY a damp
cloth, solvents should never be used.
13. This product has been designed to operate in ambient temperatures
up to 40°C.
14. This product is to be installed so that switches CANNOT be touched or
operated by a person in the bath or shower.
15. Joists, beams and rafters must not be cut, notched or damaged in the
installation of this product.
16. Ventilation products must have an adequate source of external air to ensure
rated performance can be achieved.
17. The ducting of the Bathroom Heater/Exhaust/Light must not be put in the
same flue as air-fuelled water heaters or open-fire appliances.
18. This product should not be enclosed in thermal insulation as it may cause the
unit to overheat.
19. This product should not be operated for more than 40 minutes continuously,
turn off when not in use.
20. The terminals on this product should not be over-tightened. Over tightening
may damage the product, under tightening may result in hot joints.
21. This unit is for ceiling mounting only, a minimum 2.1m above floor level.
Do not install in wardrobes or within 250mm of walls. There is a danger of
combustion if placed too close to curtains or other flammable materials.
22. Consideration must be taken in the installation of ducts to ensure that the
condensation that will form in the duct will not run back in to the fan housing.
24. The material in this product may vary in colour from batch to batch. Colour
matching from one batch to another cannot be guaranteed.
25. After installation this product must be tested as required by the appropriate
government and/or statutory regulations.
26. Ventair Pty Ltd will not be liable for any advice given to the consumer from
any of our suppliers or third parties, related or otherwise.
27. The important safeguards and instructions in this manual are not designed to
cover every possible condition or circumstance. It is understood that common
sense, caution and care are factors that cannot be built into the product,
those using and maintaining this product must supply these factors.
Parts list
Operation unit 1 piece
Infrared lamp (E27) 2 pieces
13 W LED Panel Light 1 piece
Installation instruction &
hole-cut-ting template
1 piece
Ventiduct kit 1 set
Duct clip 1 piece Ø120mm, 2 pieces Ø150mm
Switch 1 piece
Exterior vent 1 piece
Specifications
Model number 204154/204155
Rated Voltage 230 - 240 VAC
Rated Frequency 50 Hz
Rated Power 550-610 W
EGLO Lighting has a policy of continual product improvement and development,
dimensions, hardware and designs may change to reflect this policy. EGLO reserves
the right to discontinue or change product specifications & designs at any time
without notice and without incurring obligations. The images including all features
and specifications in this manual are for illustrative purposes only. Product details,
images & line drawings may vary depending on specific product models.
Installation considerations
• The unit must not be installed directly above a shower or bath. The unit
must not be installed where water may splash onto the bulbs.
• The unit must not be installed beneath a fixed socket.
• The unit is designed for installation on flat ceilings only. Do not install on
sloping ceiling or on a vertical wall.
• The infrared heating bulbs are most effective when you are standing directly
beneath them, install the unit above where you would stand to dry yourself.
To obtain the best heating effect, we recommend there is between 2.3 and
2.7 metres from the bulbs to the floor.
• For the exhaust fan to work effectively, replacement air of a volume equivalent
to what is being extracted must be able to enter the room. If the room is
airtight, leave a door or window open slightly to allow enough airflow.
• Before commencing installation, check the ceiling space to ensure there are no
obstructions such as ceiling joists, and that there is sufficient height clearance
for the housing.
Installation
1. Turn the power OFF.
2. Locate a desired position on the ceiling, do not cut a hole yet.
3. As the duct is only 3.0 m, make sure that the distance from the centre of the
installation position is not more than 3.0 m from the exterior vent outlet. It is
not recommended to use ducting longer than 3.0 m as this will lower the
performance of the exhaust fan. Check desired position suits duct length.
Fig. 1
4. Locate a position for the exterior vent on the wall not more than 3.0 m from
the unit, and allows the ducting to remain straight.
(Refer Fig. 1)
Fig. 2
5. Place this template against the ceiling and use it to mark the hole outline on
the ceiling, ensuring there is minimum 250mm between the edges of the unit
and any wall, and minimum cavity height of 250mm. Cut the hole for the unit.
(Refer Fig. 2)
6. Keep unit clear from insulation, use a barrier to keep loose-filled insulation
material away from unit.
7. Cut a 155mm diameter hole for the exterior vent outlet.
8. Connect one end of the ducting to the exterior vent with the duct clips
provided, and let the other end enter the room through the hole into the
vent hole and seal the space around the hole.
9. Remove all bulbs from the unit, unclip the internal fascia retaining springs
inside the housing, unplug the LED at the connector and remove the fascia.
10. Connect one end of the interconnecting cable wire with the switch panel.
HEATFLOW
Bathroom Heater/Fan/Light
Model 204154/204155
Installation Manual
BY VENTAIR PTY LTD
SIERRA
PREMIUM HEAT, LIGHT AND EXHAUST 3 1
in
MR2DXWH / MR2DXBL
Tri-Colour Downlight
MR2DXWH / MR2DXBL
Installation Instructions
the Manrose Sierra Premium Heat, Light and Exhaust unit.
Safety Considerations
The ducting of the Manrose Sierra Premium Heat, Light and Exhaust unit must
not be put in the same ue as air-fuelled water heaters or open-re appliances. Ventair Pty Ltd has a policy of continual product improvement and development,
dimensions, hardware and designs may change to reect this policy. Ventair Pty Ltd
reserves the right to discontinue or change product specications and designs at
any times without notice and without incurring obligations. The image including all
features and specications in this manual are for illustrative purposes only. Product
details, images and line drawings may vary depending on specic product model.
HEATFLOW Bathroom Heater/Exhaust/Light 204154/204155
HEATFLOW Bathroom Heater/Exhaust/Light 204154/204155
INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE 435 x 255 mm
INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE 435 x 255 mm
Fig. 3
11. Open the terminal block cover on the housing and make connections as per
wiring diagram and reattach the terminal block cover. (Refer Fig. 3)
12. Attach the end of the ducting to the adapter, and fit the adapter to the unit
outlet, and secure with the duct clips provided.
Fig. 4
13. Position the Bathroom Heater/Exhaust/Light unit into the hole, making sure
the duct outlet is aligned with the exterior vent, ensure all cabling is away
from the housing, and secure in place with the side spring clips. (Refer Fig. 4)
14. Fix the housing into the ceiling using the four fixing screws.
Note:
Fixing screws included are for timber fixings only, for all
alternate fixing materials, appropriate screws must be
sourced by the installer or consumer!
15. Plug in the downlight and attach the fascia to the unit using the internal fascia
retaining springs inside the housing.
16. Install the bulbs until fit is secure, do not over-tighten or under-tighten.
17. Clean the bulbs and fascia.
18. Attach the switch panel to the wall.
Wiring Diagram
Note:
This unit is fitted with a thermostat switch which will
automatically switch the exhaust fan ON, in the event
the heat bulbs are left on, and the internal temperature
exceeds 90ºC.
Operation
Heat: Turn ‘HEAT’ switch on/off.
The infrared heat bulbs provide the source of heat, do not touch while
they are in use.
Fan: Turn ‘FAN’switch on/off.
The exhaust fan will extract the steam and odours quickly and efficiently.
Light: Turn ‘LIGHT’ switch on/off.
Turn the lights off when you leave the room.
Maintenance
Cleaning:
• Turn the power OFF.
• Wipe bulbs and fascia with care using a damp soft cloth with just a small
amount of neutral detergent.
Bulb Replacement:
• Check and tighten the bulbs regularly.
• Turn the power OFF.
• Use max. 2 x 275W E27 R125 Infrared heat bulbs (EGLO part No.: ET3169)
• ONLY use designated bulbs, other bulbs may cause damage or danger.
Warranty
EGLO offers the original purchaser a repair or replacement of the EGLO product in
cases where the product fails due to defective materials or workmanship, when
installed and operated under normal domestic/residential conditions for 3 years
from the date of original purchase. Refer to the Warranty booklet enclosed with this
product for further details.
Imported by:
EGLO LIGHTING AUSTRALIA
5/339 Archerfield Road
Richlands
Queensland 4077
www.eglo.com.au
Made in China
BY VENTAIR PTY LTD
4 CAPITAL PLACE
CARRUM DOWNS VIC 3201
SIERRA
PREMIUM HEAT, LIGHT AND EXHAUST 3 1
in
Ventair Pty Ltd oers original purchaser a repair or replacement of the Manrose
product in cases where the product fails due to defective materials or workmanship,
when installed and operated under normal domestic/residential conditions for 3 years
from the original date of purchase. Refer to the warranty card for further details.

This manual suits for next models

1

Other Ventair Fan manuals

Ventair GLA1203WH User manual

Ventair

Ventair GLA1203WH User manual

Ventair WAL75-DC User manual

Ventair

Ventair WAL75-DC User manual

Ventair GYRO 250 Installation guide

Ventair

Ventair GYRO 250 Installation guide

Ventair SPINIKA Series User manual

Ventair

Ventair SPINIKA Series User manual

Ventair ROYALE DC Series User manual

Ventair

Ventair ROYALE DC Series User manual

Ventair WAL45-DC User manual

Ventair

Ventair WAL45-DC User manual

Ventair VWF150AS Assembly instructions

Ventair

Ventair VWF150AS Assembly instructions

Ventair DC 3 Series User manual

Ventair

Ventair DC 3 Series User manual

Ventair Mixflow Assembly instructions

Ventair

Ventair Mixflow Assembly instructions

Ventair Orbital 45 User manual

Ventair

Ventair Orbital 45 User manual

Ventair SPYDA SPY903NWH User manual

Ventair

Ventair SPYDA SPY903NWH User manual

Ventair PRO-V Slimline VSLF100 Assembly instructions

Ventair

Ventair PRO-V Slimline VSLF100 Assembly instructions

Ventair SPYDAEC SPYEC1253WH User manual

Ventair

Ventair SPYDAEC SPYEC1253WH User manual

Ventair STANZA STA1203WH-LR User manual

Ventair

Ventair STANZA STA1203WH-LR User manual

Ventair MALIBU Series User manual

Ventair

Ventair MALIBU Series User manual

Ventair HARMONY II Series User manual

Ventair

Ventair HARMONY II Series User manual

Ventair GYRO 200 Installation guide

Ventair

Ventair GYRO 200 Installation guide

Ventair FAN0530 User manual

Ventair

Ventair FAN0530 User manual

Ventair Z564EXTSS User manual

Ventair

Ventair Z564EXTSS User manual

Ventair PRO-V PVPX200WH User manual

Ventair

Ventair PRO-V PVPX200WH User manual

Ventair Brook 4 Installation guide

Ventair

Ventair Brook 4 Installation guide

Ventair MALIBU MAL1404WH User manual

Ventair

Ventair MALIBU MAL1404WH User manual

Ventair Stanza STA1203WH User manual

Ventair

Ventair Stanza STA1203WH User manual

Popular Fan manuals by other brands

Xpelair Simply Silent LVCV Installation and maintenance instructions

Xpelair

Xpelair Simply Silent LVCV Installation and maintenance instructions

KDK SD30H operating instructions

KDK

KDK SD30H operating instructions

Somogyi Elektronic home SFR 40 3D instruction manual

Somogyi Elektronic

Somogyi Elektronic home SFR 40 3D instruction manual

LUCCI Air AIRFUSION UNIONE-56 ORB manual

LUCCI Air

LUCCI Air AIRFUSION UNIONE-56 ORB manual

Vents Solo RA1-35A-9 P user manual

Vents

Vents Solo RA1-35A-9 P user manual

Broan sensaire hs130 instruction manual

Broan

Broan sensaire hs130 instruction manual

SCA S160-23-02310 Owner's instruction manual

SCA

SCA S160-23-02310 Owner's instruction manual

Trotec TTV 4500 Original instructions

Trotec

Trotec TTV 4500 Original instructions

Tesco PFR1614W user manual

Tesco

Tesco PFR1614W user manual

Vent-Axia LuminAir Kit L Fitting and wiring instructions

Vent-Axia

Vent-Axia LuminAir Kit L Fitting and wiring instructions

Broan 349BR manual

Broan

Broan 349BR manual

Panasonic Whisper Value-Lite FV-10VSL2 Supplementary installation instructions

Panasonic

Panasonic Whisper Value-Lite FV-10VSL2 Supplementary installation instructions

Lunos RA 15-60 installation manual

Lunos

Lunos RA 15-60 installation manual

TOTALINE TOTALINE P707 Installation and operation instructions

TOTALINE

TOTALINE TOTALINE P707 Installation and operation instructions

Viessmann Vitovent 300-W operating instructions

Viessmann

Viessmann Vitovent 300-W operating instructions

TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1... installation instructions

TJERNLUND

TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1... installation instructions

Envirovent energisava250 installation guide

Envirovent

Envirovent energisava250 installation guide

NuAire NA Series installation manual

NuAire

NuAire NA Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.