manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vertiv
  6. •
  7. UPS
  8. •
  9. Vertiv LIEBERT GXT5-6000IRT5UXL User manual

Vertiv LIEBERT GXT5-6000IRT5UXL User manual

This manual suits for next models

1

Other Vertiv UPS manuals

Vertiv Liebert NXL 500kVA User manual

Vertiv

Vertiv Liebert NXL 500kVA User manual

Vertiv Liebert PSA User manual

Vertiv

Vertiv Liebert PSA User manual

Vertiv Liebert GXT5-5000MVRT4UXLN Installation and maintenance instructions

Vertiv

Vertiv Liebert GXT5-5000MVRT4UXLN Installation and maintenance instructions

Vertiv Liebert GXT4 Series Installation and maintenance instructions

Vertiv

Vertiv Liebert GXT4 Series Installation and maintenance instructions

Vertiv NetSure +24V Battery Tray Kit User manual

Vertiv

Vertiv NetSure +24V Battery Tray Kit User manual

Vertiv Liebert PST5 Series Installation and maintenance instructions

Vertiv

Vertiv Liebert PST5 Series Installation and maintenance instructions

Vertiv Liebert GXT5 Installation and maintenance instructions

Vertiv

Vertiv Liebert GXT5 Installation and maintenance instructions

Vertiv Liebert EXS 10kVA User manual

Vertiv

Vertiv Liebert EXS 10kVA User manual

Vertiv LIEBERT PSI5 Series Installation and maintenance instructions

Vertiv

Vertiv LIEBERT PSI5 Series Installation and maintenance instructions

Vertiv Liebert EXM series User manual

Vertiv

Vertiv Liebert EXM series User manual

Vertiv Liebert PSA4 Installation and maintenance instructions

Vertiv

Vertiv Liebert PSA4 Installation and maintenance instructions

Vertiv Liebert ITA2 30kVA User manual

Vertiv

Vertiv Liebert ITA2 30kVA User manual

Vertiv Liebert APM Plus User manual

Vertiv

Vertiv Liebert APM Plus User manual

Vertiv EDGE-750IMT User manual

Vertiv

Vertiv EDGE-750IMT User manual

Vertiv Liebert GXT RT+ Series Installation and maintenance instructions

Vertiv

Vertiv Liebert GXT RT+ Series Installation and maintenance instructions

Vertiv Liebert ITA2 User manual

Vertiv

Vertiv Liebert ITA2 User manual

Vertiv Liebert Installation and maintenance instructions

Vertiv

Vertiv Liebert Installation and maintenance instructions

Vertiv Liebert NXL User manual

Vertiv

Vertiv Liebert NXL User manual

Vertiv Liebert PST5 Series User manual

Vertiv

Vertiv Liebert PST5 Series User manual

Vertiv Liebert APM2 User manual

Vertiv

Vertiv Liebert APM2 User manual

Vertiv Liebert GXT MT+ EX 1-3 kVA User manual

Vertiv

Vertiv Liebert GXT MT+ EX 1-3 kVA User manual

Vertiv Liebert MicroPOD Installation and maintenance instructions

Vertiv

Vertiv Liebert MicroPOD Installation and maintenance instructions

Vertiv Liebert EXL User manual

Vertiv

Vertiv Liebert EXL User manual

Vertiv LIEBERT PSI5 Series User guide

Vertiv

Vertiv LIEBERT PSI5 Series User guide

Popular UPS manuals by other brands

AEG Protect 3.M 2.0 manual

AEG

AEG Protect 3.M 2.0 manual

Alpha Novus FXM 650 Installation and operation manual

Alpha

Alpha Novus FXM 650 Installation and operation manual

CyberPower RB12120X2A user manual

CyberPower

CyberPower RB12120X2A user manual

Pylontech Victron & Pylontech US5000 manual

Pylontech

Pylontech Victron & Pylontech US5000 manual

BEL LDX-U20 user manual

BEL

BEL LDX-U20 user manual

Mustek PowerMust 530(B) Plus Startup manual

Mustek

Mustek PowerMust 530(B) Plus Startup manual

Emerson Liebert NXL series Operation and maintenance manual

Emerson

Emerson Liebert NXL series Operation and maintenance manual

MAKELSAN BOXER SERIES user manual

MAKELSAN

MAKELSAN BOXER SERIES user manual

Block PC-0524-400-0 manual

Block

Block PC-0524-400-0 manual

CyberPower CP585LCD user manual

CyberPower

CyberPower CP585LCD user manual

Eaton 3S Advanced user's guide

Eaton

Eaton 3S Advanced user's guide

CyberPower Office Tower Series UPS 1000 user manual

CyberPower

CyberPower Office Tower Series UPS 1000 user manual

CyberPower BM100 quick start guide

CyberPower

CyberPower BM100 quick start guide

Best Power 610 quick start guide

Best Power

Best Power 610 quick start guide

Best Power Unity/I UT3K user manual

Best Power

Best Power Unity/I UT3K user manual

Mustek PowerMust 400 Offline user manual

Mustek

Mustek PowerMust 400 Offline user manual

Xantrex Trace 512 UR-UPS owner's manual

Xantrex

Xantrex Trace 512 UR-UPS owner's manual

Forza SL-1501UL user manual

Forza

Forza SL-1501UL user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LIEBERT® GXT5™ UPS
5-6KVA I, 230V IN, 230V OUT
GXT5-5000/6000IRT5UXL
Quick Installation Guide
SL-70528_REV0_11-19 1
I M P O R TA N T: Before installing,
connecting to supply or operating
your Liebert GXT5 UPS, please
review the Safety and Regulatory
Statements sheet. For detailed
installation, operating, maintenance
and troubleshooting information
refer to the GXT5 User Guide for
your model available at
www.Vertiv.com.
INSTALLATION
1. Inspecting the UPS
Inspect the UPS for any signs of
obvious damage. If damage is
visible, do not proceed and call
our warranty support line for
assistance at 1-800-222-5877
menu option 3, or email at
microups.warranty@vertiv.com.
2. Choosing a location
Install the UPS in a
temperature-controlled
environment that is free of
corrosive and conductive
contaminants. Avoid locations
near heat or water sources and
exposed to direct sunlight.
REAR PANEL OF GXT5‑5000/6000IRT5UXL
GXT5 UPS
#Description
1Liebert® IntelliSlot™ port
2Terminal-block/Dry-contact communication connectors
3USB port
4RS-485 port
5RS-232 port
6REPO connector
7External-battery-cabinet connector
8C19 output receptacles (x2)
9Programmable C13 output receptacles (x2)
10 Output circuit breakers (x2)
11 Programmable Output circuit breakers (x2)
12 Output circuit breaker
13 Maintenance-bypass breaker
14 Cable-entry for hard-wire I/O
15 Input circuit breaker
LIEBERT® GXT5™ UPS I GXT5‑5000/6000IRT5UXL
Quick Installation Guide
2 SL-70528_REV0_11-19
For proper ventilation, leave
four inches clearance on all
sides of the UPS.
The input outlet should be
nearby and easily accessible.
3. Installing the UPS
The UPS and optional External
Battery Cabinets may be
installed in either a tower or
rack conguration. For tower
installation, assemble and
attach the tower support
stands. For rack installation,
attach the brackets to the UPS,
install the rail kit in the rack if
needed, and install the UPS in
the rack.
NOTE:
This UPS is not for use in a
computer room as dened in the
standard for the protection of
electronic computer/data
processing equipment of ANSI/
NFPA 75.
CONNECTIONS
4. Connecting External
Battery Cabinet
(Optional)
External Battery Cabinets (EBC)
provide longer battery run-time
for connected devices. Refer to
GXT5 User Guide, to select the
appropriate model and quantity
for your GXT5 model and
applications.
• Verify that the EBC breaker
is in the “O” position.
• Connect one end of the
supplied EBC cable to the
UPS battery connector and
autodetect port (terminal
block 3) and one end to the
EBC’s battery connector and
autodetect port. If connecting
more than one EBC, connect
one end of the external
battery cable to the second
set of connectors on the
battery cabinet, then connect
the other end to the next
battery
cabinet.
EBC terminal
GXT5TM UPS to External Battery Cabinet Connections
GXT5-5000/6000IRT5UXL
Shown
Single/First EBC
WIRING
Recommended external over-current
protection
40 A (5 kVA)
50 A (6 kVA)
Recommended wire size for all wires (75 °C
copper wire)
8 AWG (10 mm2)
Maximum wire accepted by terminal block 6 AWG (16 mm2)
Terminal-block torque 20 in-lb (2.26 Nm)
Second EBC
LIEBERT® GXT5™ UPS I GXT5‑5000/6000IRT5UXL
Quick Installation Guide
SL-70528_REV0_11-19 3
5. Connecting AC Input
Refer to the wiring table above
for the recommended
overcurrent protection.
Refer to the gure at the
upper-right for the terminal-
block connections. Connect to
an input-power supply that is
properly protected by a circuit
breaker in accordance with
national and local electrical
codes.
NOTE: Allow the batteries to
charge at-least 8 hours before rst
start-up to ensure adequate
back-up time. The batteries charge
when the UPS is connected to AC
input regardles of the o/on status
of the UPS.
POWERING THE UPS
NOTE: Do not start the UPS until
the installation is nished, the
system is commissioned by an
authorized engineer, and the
external input circuit breakers are
closed.
1. Make sure the maintenance
bypass switch is in the open
“OFF” position and that the
guard is secured in place.
2. Ensure that the REPO
connector on the rear of the
unit has a jumper between
pins 1-2 or that it is properly
wired to an Emergency Power-
O circuit (normally closed).
3. Make sure the breaker
supplying power to the UPS is
closed, and close the input
breaker on the rear of the UPS.
4. If necessary, use the LCD
display or a connected
computer to adjust any
required settings. (Refer to the
User Guide for conguration
set up.)
5. Close all output breakers on
the rear of the UPS (or in an
external panel board, if used).
6. If external battery cabinets are
included, close the breakers on
the rear of each cabinet.
7. Power-on the UPS using the
Operation and Display Panel
(see the illustration above) by
pressing and holding the power
button until the conrmation
dialog appears. Use the Up/
Down arrows to select “YES”,
then press Enter.
NOTE: During operation, the UPS
may sound an alarm as the output
receptacles are powered. You may
press the Esc button for 2 seconds
to silence the audible alarm.
Terminal Block Connections
Display
screen
Power
Operation and Display Panel
Run Alarm
Enter
Down
Up
Escape
To contact Vertiv Technical Support: visit www.Vertiv.com
© 2019 Vertiv Group Corp. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are
trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Group
Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specications are subject to change
without notice.
4 SL-70528_REV0_11-19