VICI DBS MINI WHISPER User manual

1
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
TECH SUPPORT
Europe, Asia, Africa, Australia & New Zealand:
techsupport@vicidbs.com
USA, Canada, Central & South America:
techsupportusa@vicidbs.com
Italy
VICI AG INTERNATIONAL
Parkstrasse 2
CH-6214 Schenkon
Switzerland
tel: +41 41 925-6200
fax: +41 41 925-6201
web: www.vicidbs.com
APPLICABLE MODELS
This manual is applicable to the following models:
• Mini Whisper
Version 1.03.0000

1
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
TABLE OF CONTENTS
1. VERSION HISTORY................................................................................................................................ 2
2. INTRODUCTION.................................................................................................................................... 2
2.1. FUNCTIONALITY.................................................................................................................................2
2.2. SYMBOL DEFINITIONS.......................................................................................................................3
3. SAFETY.................................................................................................................................................. 4
3.1. PERSONAL SAFETY INSTRUCTIONS..................................................................................................4
3.2. INSTRUMENT SAFETY INSTRUCTIONS.............................................................................................4
3.3. WARNING ...........................................................................................................................................4
4. SPECIFICATIONS ................................................................................................................................... 5
4.1. TECHNICAL SPECIFICATIONS ............................................................................................................5
4.2. CAPACITY ...........................................................................................................................................6
4.3. SPARE PARTS ......................................................................................................................................6
4.3. SEPARATION PRINCIPLE ....................................................................................................................6
4.4. COMPONENTS...................................................................................................................................7
4.5. PROCESS DIAGRAM...........................................................................................................................8
5. INSTALLATION ...................................................................................................................................... 8
5.1 TRANSPORT.........................................................................................................................................8
5.2 LOCATION...........................................................................................................................................8
5.3 CONNECTING THE MINI WHISPER TO THE LC-MS...........................................................................8
6. OPERATION........................................................................................................................................... 8
6.1 STARTING THE UNIT ...........................................................................................................................8
6.2 STOPPING THE UNIT ..........................................................................................................................9
7. TROUBLESHOOTING............................................................................................................................. 9
8. MAINTENANCE..................................................................................................................................... 9
8.1 MAINTENANCE...................................................................................................................................9
8.2 CHANGING THE FILTERS..................................................................................................................10
9. FLOW SCHEMATIC .............................................................................................................................. 11

2
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
1. VERSION HISTORY
VERSION DATE COMMENT/CHANGE
1.00.0100 1/18/2017 Layout and initial release, VICI DBS
1.01.0000 1/8/2019 Update
1.02.0000 3/11/2019 Layout, images and graphics, VICI Gig Harbor Group
1.03.0000 2/4/2021 New layout, minor copy updates, VICI Gig Harbor Group
2. INTRODUCTION
This manual is an integral part of the product. The manual describes the installation and maintenance
operations as well as user modes and troubleshooting.
Contents
Read the manual carefully before starting up the Mini Whisper and familiarize yourself with its content.
Modications
Do not make any modications to the Mini Whisper unless explicit written permission has been given by the
manufacturer. If such modications are made without the manufacturer’s consent, the manufacturer denies any
responsibility for eventual consequential damage.
Information
All information provided in this manual, including drawings, tables, and technical descriptions, remain the
property of the manufacturer and may not be used (with the exception of the purposes herein), copied,
reproduced or published without explicit consent.
2.1. Functionality
The Mini Whisper separates compressed air into pure nitrogen and oxygen-enriched air. The separation
system is based on a special membrane technology.

3
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
2.2. Symbol Denitions
SYMBOL DESCRIPTION
General warning. Caution is necessary when operating the device or control
close to where the symbol is placed, or to indicate that the current situation
needs operator awareness or operator action in order to avoid undesirable
consequences.
The manual must be consulted in all cases where this symbol is marked on
the device.
Risk of asphyxia. Caution is necessary when operating the device in a not
sufciently ventilated area.
Oxidant material. Caution is necessary due to the presence of oxidant material.
WEEE symbol. When discard this product, it must be sent to separate collection
facilities for recovery and recycling.
Fuse. Notify replaceable fuse place.
OR
OR
OR

4
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
3. SAFETY
3.1. Personal Safety Instructions
The Mini Whisper is a nitrogen generator. Do not operate the generator with the nitrogen outlet
open in a small or not sufciently ventilated room. An increase of the nitrogen and a decrease of
the oxygen concentration in the air may cause health problems. It is the responsibility of the user to
check whether the room is appropriate or an O2measurement is necessary.
3.2. Instrument Safety Instructions
The Mini Whisper ejects oxygen as waste. Oxygen concentration in the air could change around the
generator in a small or not sufciently ventilated room. If fuel gases are present, their explosive or
ammable limits could be affected.
3.3. Warning
• The quantity of dust in the ambient Air can be very different from one place to
another. We recommend replacement of the dust lters every 4000 hours. In
some dusty areas, this maintenance needs to be performed more frequently.
• Clogged dust lters may damage the generator or give a bad Nitrogen quality.
• If the Mini Whisper is used in a way not specied by VICI DBS, the protection
provided by the equipment could be compromised.

5
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
4. SPECIFICATIONS
4.1. Technical Specications
MINI WHISPER
Flow L/min 12
Purity 99% @ 12 L/min
99% @ 10 L/min
Dewpoint -50 ºC
Outlet pressure barg (psig) 7 (100)
Inlet pressure barg (psig) 8.5 to 10 (123 to 160)
Actual inlet air requirement liters 60
Recommended compressor air inlet 120
Pressure drop barg (psig) 1.5 (22)
Inlet air quality Clean dry compressed air ISO8573-1:2010 Class 1.2.1
Technology Membrane
Warm up time (minutes) None
Electrical supply None
Noise level None
Dimensions mm (in) 348W x 735H x 350D (13.7W x 29H x 13.7D)
Weight kg (lbs) 8 (17.6)
Shipping dimensions mm (in) 890W x 445H x 3530D (35W x 17.5H x 20.8D)
Shipping weight kg (lbs) 14 (31)
Operating temp oC (oF) 15 to 35 (59 to 95)
Inlet connection 3/8” G
Outlet connection 1/4” Compression
Certication CE
MODELS & SPECS

6
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
A special characteristic of the Mini Whisper is the momentary stop of the compressor if the LCMS is not using
Nitrogen. This momentary stop is regulated by a pneumatic control valve pre-calibrated by VICI DBS. This will
extend the life span of the compressor and at the same time help save energy.
4.2. Spare Parts
PART NUMBER DESCRIPTION
DB-WN2-001 Annual Filter Kit (3 lters)
DB-WN2-002 Pneumatic Valve
DB-WN2-003 Manometer
DB-WN2-005 10 liter tank
DB-WN2-006 Tube 10 m
DB-WN2-014 Valveless N2 small membrane
DB-WN2-015 Filter housing for A0035 element without ttings
DB-WN2-016 Filter housing for V0035 and S0035 element without ttings
4.3. Seperation Principle
A
FS
H2O - H2 O2 N2
B
C
ACompressed Air Input BHollow Fiber Membrane CNitrogen Output
Atmospheric air contains nitrogen (78.1%), oxygen (20.9%), argon (1%), carbon dioxide, water vapor, and
traces of inert gases. The compressed air (A) is forced through the hollow ber membrane (B). The various
components of the air permeate the porous membrane walls.

7
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
The speed of permeation varies from gas to gas:
• Oxygen and water vapor have a high permeation speed and pass quickly through the membrane wall
• Nitrogen has a slow permeation speed and passes slowly through the membrane wall
• The resulting Nitrogen ow (C) is then forced out of the membrane and used directly
4.4. Components
A
D
B C
E
A. Active Carbon Filter
B. Air Inlet/Coalescent Filter
C. Coalescent Filter for ne particles
D. Pressure Gauge
E. Nitrogen Outlet (coupling for 6 mm diameter tube)

8
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
4.5. Process Diagram
Compressed Air Mini Whisper LC-MS (or other)
5. INSTALLATION
5.1. Transport
Transport the Mini Whisper without tipping it.
Transport the Mini Whisper in the original packing.
5.2. Location
Install the Mini Whisper in an area with the following characteristics:
• Minimum distance of 20 cm at the front and lateral sides to allow sufcient cooling
• An enclosed (indoor), dry room
• Avoid direct sunlight
• Keep away from heat sources
• Room with adequate aeration/ventilation
• Connect a tube for waste humidity from lters “B” and “C”
5.3. Connecting the Mini Whisper to the LC-MS
ATTENTION: Check that the tubing connecting the Mini Whisper and the LC-MS is free from dust, grease,
drops of liquid etc., before making the connection. Connect the Mini Whisper and the LC-MS with stainless
steel tubing.
6. OPERATION
6.1. Starting the Unit
1. Connect the Air Inlet “B” (page 7) to the air supply line from the compressor (oil free!)
2. Install a piece of tubing from the nitrogen outlet to the LC-MS or another equipment using nitrogen
3. Slowly open the red tap upstream from the coalescent lter “B”
4. Slowly open the red taps from the air outlets
5. The generator is ready to be used

9
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
6.2. Stopping the Unit
To stop the generator, just close the red taps from the air outlets and the red tap from the coalescent lter
“B”.
7. TROUBLESHOOTING
ERROR POSSIBLE CAUSE POSSIBLE SOLUTION
Nitrogen ow insufcient or lacking Internal lters are contaminated Replace the lters
The Mini Whisper is off Start the Mini Whisper
There is a leak somewhere Check for possible leaks
Nitrogen outlet obstructed Check and clear the nitrogen
outlet
Oxygen concentration is too high Room temperature is less than
10º C
Raise the room temperature
Membrane no longer functions
correctly
Membrane column must be
replaced
8. MAINTENANCE
8.1. Maintenance
PARTS ACTION FREQUENCY
DB-WN2-001 Replace the internal lters Annually

10
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
8.2. Changing the Filters
1. Turn the Mini Whisper off
2. Close the red tap upstream from the coalescent lter “B”
3. Let the generator depressurize till the pressure is 0 bar
4. Remove the cap, unscrew it from the main body (1) and pull it down (2)
5. Remove the lter cartridge by pulling it down (3)
6. Replace the ltering element and reassemble the parts in reverse order

11
MINI WHISPER
USER MANUAL www.vicidbs.com
Version 1.03.0000
9. FLOW SCHEMATIC
System:
Schematic no:
Date:
Created:
Checked:
Released:
THIS DOCUMENT AND THE INFORMATION WHICH
IT CONTAINS SHALL NOT BE USED, EXPLOITED
OR SOLD, AND SHALL NOT BE REVEALED OR
DISCLOSED TO OTHERS WITHOUT THE EXPRESS
WRITTEN PERMISSION OF VICI. THIS DOCUMENT
SHALL REMAIN THE PROPERTY OF VICI AND
SHALL BE RETURNED UPON DEMAND.
R
Rev.:
Sheet:
By:
Description:
ECN no:
Mini Whisper flow
air flow diagram 04.12.20 SBU
1
Table of contents
Other VICI DBS Portable Generator manuals

VICI DBS
VICI DBS HK PLUS Series User manual

VICI DBS
VICI DBS MISTRAL User manual

VICI DBS
VICI DBS MISTRAL EVOLUTION HYBRID User manual

VICI DBS
VICI DBS HP PLUS Series User manual

VICI DBS
VICI DBS NM PLUS Series User manual

VICI DBS
VICI DBS MISTRAL EVOLUTION 10 User manual

VICI DBS
VICI DBS GT ULTRA ZERO AIR GENERATOR User manual

VICI DBS
VICI DBS NM PLUS User manual

VICI DBS
VICI DBS NM Plus 100 FID Tower User manual

VICI DBS
VICI DBS PCB 1500 User manual