Videx B100-SA v2 User guide

Standalone Biometric Reader
INSTALLER’S MANUAL
v. c1
B100-SA v2
1

INTRODUCTION
MOUNTING
SPECIFICATIONS
APPLICATION DIAGRAM
RECOMMENDED SWIPING TECHNIQUE
INDICATION
WIRING
ADDING ADMIN FINGER
PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing B100-SA v2 with DINRTT
Pairing B100-SA v2 with RTT
Pairing B100-SA v2 with RU2
ADMINISTRATOR PROGRAMMING
ADD Finger Relay 1
ADD Finger Relay 2
ADD Finger Relay 1&2
DELETE Finger
DELETE ALL Fingers
CHANGE ADMIN Finger
CHANGE INSTALLER Finger
Administrator Programming block diagram
INSTALLER PROGRAMMING
Set Relay 1 Time
Set Relay 2 Time
BUZZER ON/OFF
BACKLIGHT ON/OFF
Installer Programming block diagram
3
3
4
4
4
4
5
5
Contents
..............................................................
..............................................................
...........................................................
...........................................................
.............................................................
....................................................................
....................................................................
...........................................
..............................................................
..............................................................
..............................................................
..............................
...........................................................
...........................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
...........................................................
7
7
7
7
7
8
8
8
8
6
6
6
9
9
9
9
9
10
...........................................................
6
2

4.
Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the MC-MINI metal cover available in our accessories in order to protect
the sensor from direct rainfall. The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the
temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a
third party sealed wall mount box (fitted with additional heater if very low temperature) to keep a constant sensor level performance. Videx™ cannot
guarantee the functionality of the product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use
different readers depending on users.
1.
Cable
Ø6.0(3NoS)
30mm
5mm
2.
3 (3 x 30mm)
3.
1 (M3 x 6mm)
MC-MINI
B100-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The
scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance in the way finger is swiped over the sensor
reducing to minimum the need to repeat finger swiping at the sensor.
The reader can store up to 100 finger templates. One template is reserved for User manager (Administrator), one
template is reserved for Reader configuration (Installer) and up to 98 templates are for Users.
INTRODUCTION
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can increase the security of
the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he leaves the site to enroll your finger as
administrator.
Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or construction work is ongoing in
the area around the reader, protect the reader sensor area from possible damages and paint. If reader is to be dismounted or relocated, call authorized
installer for the job. Disposal of this product must be handled according to all national laws and regulations.
RECOMMENDATIONS
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips, making difficult for the sensor to
recognize correctly the fingerprint. In most cases, these are children and older persons. To solve this problem, do the following:
1. Try with different user’s fingers to find the “best” finger.
2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use chemicals and materials that can
scratch the sensor.
WARNING!
MOUNTING
3

APPLICATION DIAGRAM
RS485 (max. 50m)
DINRTT (Oponal)
2 Relay Remote Unit
and request-to-exit Buon
B100-SA v2
Standalone Biometric Reader
RTT (Oponal)
1 Relay Remote Unit
and request-to-exit Buon
RU2 (Oponal)
2 Relay Remote Unit
OR
Fingerprint Capacity:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Admin/Installer Fingers:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
IP Factor:
Storage/Operating Temperature :
Storage/Operating Humidity:
Dimensions(mm):
98 templates
1 x Relay ( )2 A /24V AC/DC
Yes
Pulse (1 to 30 seconds) or Toggle (ON/OFF)
Finger
By swiping
1 Administrator and 1 Installer Finger
Yes
Yes
via RS485 converter and windows application
100 mA max.
9-14 V DC
Tricolor tatus LEDS
IP65
-20°C to +50°C
5% to 93% RH without condensation
x x 92 51 25
B100-SA v2
51mm
92mm
25mm
SPECIFICATIONS
MC-MINI
(Oponal)
Metal Cover
Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the
selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
Tricolor Status LED
- Access GrantedGreen
- Access deniedRed
- Idle ModeOrange
OK Beep - short + long beep
- 3 short beepsError Beep
Swipe Finger - 2 short beeps
RECOMMENDED SWIPING TECHNIQUE
INDICATION
Secured Area Outside
4

ADDING ADMIN FINGER
1.Push dip switch no.2 in position ON.
2.Reset the Power of the device.
3.Wait for One long + mulple short beeps
4.Put the dip switch in position OFF. (short beeps will stop)
5.Wait for about 15 seconds for the LED to blink in Orange.
6.Swipe the Admin finger min.6 mes. (Unl Ok Beep)
1 2
ON
1 2
ON
No.2
No.2
Warning: This procedure also deletes all the users and the installer finger.
Warning: This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)
x 6
NC
COM
NO
Tamp
Blue
Yellow
Red
Black
Pink
Violet
Orange
Gray
White
PB
RS485
+
_
12VDC
POWER SUPPLY
+
_
NC
COM
GND (PB)
PB
+
_
Electro Magnetic Lock
Green
Blue
Yellow
Red
Black
Pink
Violet
Orange
Gray
White
Green
Colour
Connection
Tamper
12V DC
Red
Black
White
Yellow
Grey
NC
COM
NO
GND
Green
Relay
(2A)
Push Button
Orange
Pink
Violet
Blue
Tamper
A (RS485)
B (RS485)
1N4001
Diode
12V DC
GND
A
B
WIRING
1N4007
+
-
Electric
Strike
NO
12/24V AC/DC
5

B (RS485)
A (RS485)
1. Close the Jumper. DINRTT beeps continuously and
the red led blinks.
2. Open the Jumper
3. Wait for Beep + OK Beep (short + short + long
beep)
After the OK beep, the coupling is done.
PB2
GND
PB1
GND
NC1
COM
NO1
NC2
COM
NO2
A
BTAMP TA MP
RS485
GND
+12V
GND
+12V
Exit Button
(NO)
1N4007
+
-
12 VDC +
-
DINRTT
+12V
+12V
GND
GND
GND
PB1
NO1
COM
1 2
1. Put Dipswitch No.1 to position ON. RTT
beeps continuously and the red led
blinks.
2. Put Dipswitch No.1 to position OFF.
3. Wait for Beep + OK Beep (short + short +
long beep)
After the OK beep, the coupling is done.
1 2
ON
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of
request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay’s Manual.
12 VDC +
-
1N4007
+
-
RTT
Black
Red
Pink
Violet
Black
Brown
Pink
Violet
Red
White
Yellow COM
NO
GND
12V out
A (RS485)
B (RS485)
B100-SA v2
Black
Red
Pink
Violet
BRS485
12 VDC
+
-
Warning: Changing the ADMIN finger will also unpair the remote relay unit.
PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing B100-SA v2 with DINRTT
Pairing B100-SA v2 with RTT
Pairing B100-SA v2 with RU2
1. Put the Jumper to closed position. RU2
beeps continuously and the red led
blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short +
long beep)
After the OK beep, the coupling is done.
12 VDC
+
-
1N4007
+
-
RU2
Violet
Pink
COMNO
A (RS485)
B (RS485) +12V
GND
GND
+12V
B100-SA v2
+
_
Electro Magnetic Lock
1N4001
Diode
NC2
1
2
max. 50 meters
max. 50 meters
max. 50 meters
6

short beep
Swipe Admin Finger 1 time
Action
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
Finger Backlight Buzzer Sound
x 1
Swipe Admin Finger 2 times
Action
Wait 5 seconds (until fast blinking)
Finger Backlight Buzzer Sound
x 2
Swipe Admin Finger 3 times
Action
Wait 5 seconds (until fast blinking)
Finger Backlight Buzzer Sound
x 3
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers.
Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin
finger is described in installer manual.
Swipe Admin Finger 4 times
Action
Wait 5 seconds (until fast blinking)
Swipe User Finger
Finger Backlight Buzzer Sound
x 4
ADMINISTRATOR PROGRAMMING
ADD Finger Relay 1 (Finger that will activate relay 1)
ADD Finger Relay 2 (Finger that will activate relay 2)
ADD Finger Relay 1&2 (Finger that will activate relay 1&2)
DELETE Finger
slow blinking
fast blinking short + long beep
short beep
slow blinking
fast blinking
slow blinking
fast blinking
short beep
short + long beep
short beep
short beep
short + long beep
short beep
slow blinking
fast blinking
short beep
short + long beep
short beep
INSTALLER
RIGHT
ADMIN
LEFT
x 6
Swipe User Finger min. 6 times
(until short + long beep) x 6
Swipe User Finger min. 6 times
(until short + long beep) x 6
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
x 1
7

Swipe Admin Finger 5 times
Action
Wait 5 seconds (until fast blinking)
Swipe NEW Admin Finger
min.6 times
Finger Backlight Buzzer Sound
x 5
x 6
short beep
short + long beep
3 short beeps
Swipe Admin Finger 6 times
Action
Wait 5 seconds (until fast blinking)
Swipe NEW Installer Finger
min.6 times
Finger Backlight Buzzer Sound
x 6
x 6
short beep
multiple beeps
Swipe Admin Finger 4 times
Action
Wait 5 seconds (until fast blinking)
Swipe Admin Finger 2 times
Finger Backlight Buzzer Sound
x 4
x 2
ADD Finger
Relay 1
1 swipe
ADD Finger
Relay 2
ADD Finger
Relay 1&2 DELETE FINGER
Change
ADMIN
Finger
Enroll
INSTALLER
Finger
2 swipes 3 swipes 4 swipes 5 swipes 6 swipes
Wait
5 seconds
(until fast blinking)
SWIPE
new finger
min. 6 times
SWIPE
already enrolled
finger
1 time
SWIPE
new finger
min. 6 times
SWIPE
new finger
min. 6 times
SWIPE
ADMIN finger
2 times
to
DELETE ALL
SWIPE
new ADMIN
FINGER
min. 6 times
SWIPE
new
INSTALLER
FINGER
min. 6 times
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
END END END END END END END
DELETE ALL Fingers
CHANGE ADMIN Finger
CHANGE/ADD INSTALLER Finger
Administrator Programming block diagram
slow blinking
slow blinking
fast blinking
short beep
slow blinking
slow blinking
fast blinking
short beep
short + long beep
short beep
slow blinking
slow blinking
fast blinking
Only in combination
with DINRTT and RU2
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
8

short beep
Swipe Installer Finger 1 time
Action
Swipe the INSTALLER Finger
and start counting seconds
Finger Backlight Buzzer Sound
Set Relay 1 Time
slow blinking
fast blinking beeps on 1 second
short beep
INSTALLER PROGRAMMING
x 1
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
fast blinking short + long beep
x 1
x 1
short beep
Swipe Installer Finger 2 times
Action
Swipe the INSTALLER Finger
and start counting seconds
Finger Backlight Buzzer Sound
Set Relay 2 Time
slow blinking
fast blinking beeps on 1 second
short beep
x 2
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
fast blinking short + long beep
x 1
x 1
Swipe Installer Finger 3 times
Action
Swipe Installer Finger
Finger Backlight Buzzer Sound
x 3
Swipe Installer Finger 4 times
Action
Swipe Installer Finger
Finger Backlight Buzzer Sound
x 4
BUZZER ON/OFF
slow blinking
fast blinking
short beep
short + long beep
short beep
slow blinking
fast blinking
short beep
short + long beep
short beep
BACKLIGHT ON/OFF
x 1
x 1
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
9

Set
RELAY 1
Time
1 swipe
Set
RELAY 2
Time
BUZZER
ON/OFF
BACKLIGHT
ON/OFF
2 swipes 3 swipes 4 swipes
Wait
5 seconds
(until fast blinking)
Swipe the Installer Finger 1 to 4 times depending of the desired menu
END END END END
Installer Programming block diagram
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to put the Buzzer ON/OFF
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Only in combination
with DINRTT and RU2
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger
to put the Backlight
ON/OFF
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
10

11

This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with
RoHS directive EN50581:2012
12
Northern Office
Videx Security Ltd
Unit 4-7 Chillingham ind Est
Newcastle Upon Tyne
NE6 2XX
Tel: 0870 300 1240
Fax: 0191 224 5678
Southern Office
1 Osprey
Trinity Park
Trinity Way
London
E4 8TD
Fax: 0208 523 5825
Table of contents
Other Videx IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

IDTECK
IDTECK Star iCON100 user manual

eKey
eKey home FS IN operating instructions

Fermax
Fermax 5226 Installer manual

Spiderdoor
Spiderdoor S14c installation guide

ACT
ACT ACTPRO 3000 ACCESS CONTROL UNITS Operating and installation instructions

Alarm Lock
Alarm Lock Trilogy DK3000 Series installation instructions