Videx DINB100-SA v2 User manual

USER’S MANUAL
v. c2
Standalone Biometric Reader
DINB100-SA v2
1

INTRODUCTION
MOUNTING
SPECIFICATIONS
APPLICATION DIAGRAM
RECOMMENDED SWIPING TECHNIQUE
INDICATION
WIRING
ADDING ADMIN FINGER
PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing DINB100-SA with DINRTT
Pairing DINB100-SA with RTT
Pairing DINB100-SA with RU2
ADMINISTRATOR PROGRAMMING
ADD Finger Relay 1
ADD Finger Relay 2
ADD Finger Relay 1&2
DELETE Finger
DELETE ALL Fingers
CHANGE ADMIN Finger
CHANGE INSTALLER Finger
Administrator Programming block diagram
INSTALLER PROGRAMMING
Set Relay 1 Time
Set Relay 2 Time
BUZZER ON/OFF
BACKLIGHT ON/OFF
Installer Programming block diagram
ADMINISTRATOR PROGRAMMING BY KEYPAD
ADMINISTRATOR PROGRAMMING BY KEYPAD
3
3
4
4
4
4
5
5
Contents
..............................................................
..............................................................
...........................................................
...........................................................
.............................................................
....................................................................
....................................................................
...........................................
..............................................................
..............................................................
..............................................................
..............................
...........................................................
...........................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
...........................................................
7
7
7
7
7
8
8
8
9
6
6
6
10
10
10
10
10
11
...........................................................
6
...........................................
...........................................
12
14
2

Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the MC-MINI metal cover available in our accessories in order to protect
the sensor from direct rainfall. The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the
temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a
third party sealed wall mount box (fitted with additional heater if very low temperature) to keep a constant sensor level performance. Videx™ cannot
guarantee the functionality of the product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use
different readers depending on users.
DINB100-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The
scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance in the way finger is swiped over the sensor
reducing to minimum the need to repeat finger swiping at the sensor.
The reader can store up to 100 finger templates. One template is reserved for User manager (Administrator), one
template is reserved for Reader configuration (Installer) and up to 98 templates are for Users.
INTRODUCTION
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can increase the security of
the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he leaves the site to enroll your finger as
administrator.
Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or construction work is ongoing in
the area around the reader, protect the reader sensor area from possible damages and paint. If reader is to be dismounted or relocated, call authorized
installer for the job. Disposal of this product must be handled according to all national laws and regulations.
RECOMMENDATIONS
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips, making difficult for the sensor to
recognize correctly the fingerprint. In most cases, these are children and older persons. To solve this problem, do the following:
1. Try with different user’s fingers to find the “best” finger.
2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use chemicals and materials that can
scratch the sensor.
WARNING!
MOUNTING
3

APPLICATION DIAGRAM
RS485 (max. 50m)
DINRTT (Oponal)
2 Relay Remote Unit
and request-to-exit Buon
DINB100-SA v2
Standalone Biometric Reader
RTT (Oponal)
1 Relay Remote Unit
and request-to-exit Buon
RU2 (Oponal)
2 Relay Remote Unit
OR
DINB100-SA v2
SPECIFICATIONS
Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the
selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
Tricolor Status LED
- Access GrantedGreen
- Access deniedRed
- Idle ModeOrange
OK Beep - short + long beep
- 3 short beepsError Beep
Swipe Finger - 2 short beeps
RECOMMENDED SWIPING TECHNIQUE
INDICATION
Secured Area Outside
123
456
789
A0B
Oponal
Keypad
OR
Oponal
Proximity Reader
use the cable provided
with the keypad/reader
Note: Frame sold separately
Fingerprint Capacity:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Admin/Installer Fingers:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
IP Factor:
Storage/Operating Temperature :
Storage/Operating Humidity:
Dimensions(mm):
98 templates
1 x Relay ( )2 A /24V AC/DC
Yes
Pulse (1 to 30 seconds) or Toggle(ON/OFF)
Finger (basic installation)
Finger or Card (when used with card reader DIN Card reader)
Finger or PIN code (when used with keypad DINPAD-M)
By swiping
1 Administrator and 1 Installer Finger
Yes
Yes
via RS485 converter and windows application
100 mA max.
9-14 V DC
Tricolor Status LED
IP40
-20°C to +50°C
5% to 93% RH without condensation
80 x 80 x 9
4

ADDING ADMIN FINGER
1.Close the jumper on the back of the device.
2.Reset the Power of the device.
3.Wait for One long + mulple short beeps
4.Open the jumper. (short beeps will stop)
5.Wait for about 15 seconds for the LED to blink in Orange.
6.Swipe the Admin finger min.6 mes. (Unl Ok Beep)
Warning: This procedure also deletes all the users and the installer finger.
Warning: This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)
WIRING
12/24V AC/DC
12V
GND
B
A
DINB100-SA
x 6
NC
C
NO
12V
GND
B
PB
A
GND
tamp
tamp
Relay Output
1N4007
Electric Door Strike
(DC powered)
+
-
Exit Buon (NO)
Jumper (Adding Master Finger)
12 VDC
+-
12V
GND
B
PB
A
GND
tamp
tamp
PB
GND(PB)
tamp
tamp
C
NO
Alarm
12V
GND
Power Supply
(9-14V DC)
GND
B
+12V
PB
GND
ARS485
Push Button
Tamper
tamp
tamp
NC
C
NO
NC
C
NO
Connection to additional
card reader or keypad
DINB100-SA v2
5

1. Close the Jumper. DINRTT beeps continuously and
the red led blinks.
2. Open the Jumper
3. Wait for Beep + OK Beep (short + short + long
beep)
After the OK beep, the coupling is done.
1. Put Dipswitch No.1 to position ON. RTT
beeps continuously and the red led
blinks.
2. Put Dipswitch No.1 to position OFF.
3. Wait for Beep + OK Beep (short + short +
long beep)
After the OK beep, the coupling is done.
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of
request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay’s Manual.
Warning: Changing the ADMIN finger will also unpair the remote relay unit.
PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing DINB100-SA with DINRTT
Pairing DINB100-SA with RTT
Pairing DINB100-SA with RU2
1. Put the Jumper to closed position. RU2
beeps continuously and the red led
blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short +
long beep)
After the OK beep, the coupling is done.
12 VDC
+
-
1N4007
+
-
RU2
Violet
Pink
COMNO
A (RS485)
B (RS485) +12V
GND
GND
+12V
DINB100-SA v2
1
2
max. 50 meters
RS485
AB
12V
GND
B
A
+12V
GND
12 VDC
+
-
DINB100-SA
AB
+12V
GND
1N4007
+
-
12 VDC +
-
NO
COM
RTT
1 2
ON
PB2
GND
PB1
GND
NC1
COM
NO1
NC2
COM
NO2
A
BTAMP T AMP
RS485
GND
+12V
GND
+12V
Exit Button
(NO)
1N4007
+
-
RS485
AB
12V
GND
B
A
+12V
GND
12 VDC
+
-
12 VDC +
-
DINB100-SA v2 DINRTT
AB
+12V
+12V
GND
GND
GND
PB1
NO1
COM
1 2
max. 50 meters
max. 50 meters
6

short beep
Swipe Admin Finger 1 time
Action
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
Finger Backlight Buzzer Sound
x 1
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers.
Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin
finger is described in installer manual.
ADMINISTRATOR PROGRAMMING
ADD Finger Relay 1 (Finger that will activate relay 1)
slow blinking
fast blinking short + long beep
short beep
INSTALLER
RIGHT
ADMIN
LEFT
x 6
Present card/tag 1 time fast blinking short + long beep
or
Swipe Admin Finger 2 times
Action
Wait 5 seconds (until fast blinking)
Finger Backlight Buzzer Sound
x 2
ADD Finger Relay 2 (Finger that will activate relay 2)
slow blinking
fast blinking
short beep
short + long beep
short beep
Swipe User Finger min. 6 times
(until short + long beep) x 6
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
Present card/tag 1 time fast blinking short + long beep
or
Swipe Admin Finger 3 times
Action
Wait 5 seconds (until fast blinking)
Finger Backlight Buzzer Sound
x 3
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
ADD Finger Relay 1&2 (Finger that will activate relay 1&2)
slow blinking
fast blinking
short beep
short + long beep
short beep
Swipe User Finger min. 6 times
(until short + long beep) x 6
Present card/tag 1 time fast blinking short + long beep
or
x 1
x 1
x 1
7

Swipe Admin Finger 4 times
Action
Wait 5 seconds (until fast blinking)
Swipe User Finger
Finger Backlight Buzzer Sound
x 4
DELETE Finger
slow blinking
fast blinking
short beep
short + long beep
short beep
x 1
Present card/tag 1 time short + long beep
or
fast blinking
Swipe Admin Finger 5 times
Action
Wait 5 seconds (until fast blinking)
Swipe NEW Admin Finger
min.6 times
Finger Backlight Buzzer Sound
x 5
x 6
short beep
short + long beep
3 short beeps
Swipe Admin Finger 6 times
Action
Wait 5 seconds (until fast blinking)
Swipe NEW Installer Finger
min.6 times
Finger Backlight Buzzer Sound
x 6
x 6
CHANGE ADMIN Finger
CHANGE/ADD INSTALLER Finger
slow blinking
slow blinking
fast blinking
short beep
short + long beep
short beep
slow blinking
slow blinking
fast blinking
short beep
multiple beeps
Swipe Admin Finger 4 times
Action
Wait 5 seconds (until fast blinking)
Swipe Admin Finger 2 times
Finger Backlight Buzzer Sound
x 4
x 2
DELETE ALL Fingers and Cards
slow blinking
slow blinking
fast blinking
short beep
x 1
CONNECTING DINB100 WITH DINMTPX PROXIMITY READER
DINMTPX
DINB100-SA v2
Connect both devices with the cable
provided. The proximity reader will be
powered via that cable. No extra power
supply for the proximity reader is needed.
Once connected, no further settings are
needed.
8

ADD Finger
Relay 1
1 swipe
ADD Finger
Relay 2
ADD Finger
Relay 1&2 DELETE FINGER
Change
ADMIN
Finger
Enroll
INSTALLER
Finger
2 swipes 3 swipes 4 swipes 5 swipes 6 swipes
Wait
5 seconds
(until fast blinking)
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
already enrolled
finger
1 time
or
present
card/tag
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
ADMIN finger
2 times
to
DELETE ALL
SWIPE
new ADMIN
FINGER
min. 6 times
SWIPE
new
INSTALLER
FINGER
min. 6 times
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
END END END END END END END
Administrator Programming block diagram
Only in combination
with DINRTT and RU2
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
9

short beep
Swipe Installer Finger 1 time
Action
Swipe the INSTALLER Finger
and start counting seconds
Finger Backlight Buzzer Sound
Set Relay 1 Time
slow blinking
fast blinking beeps on 1 second
short beep
INSTALLER PROGRAMMING
x 1
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
fast blinking short + long beep
x 1
x 1
short beep
Swipe Installer Finger 2 times
Action
Swipe the INSTALLER Finger
and start counting seconds
Finger Backlight Buzzer Sound
Set Relay 2 Time
slow blinking
fast blinking beeps on 1 second
short beep
x 2
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
fast blinking short + long beep
x 1
x 1
Swipe Installer Finger 3 times
Action
Swipe Installer Finger
Finger Backlight Buzzer Sound
x 3
Swipe Installer Finger 4 times
Action
Swipe Installer Finger
Finger Backlight Buzzer Sound
x 4
BUZZER ON/OFF
slow blinking
fast blinking
short beep
short + long beep
short beep
slow blinking
fast blinking
short beep
short + long beep
short beep
BACKLIGHT ON/OFF
x 1
x 1
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
10

Set
RELAY 1
Time
1 swipe
Set
RELAY 2
Time
BUZZER
ON/OFF
BACKLIGHT
ON/OFF
2 swipes 3 swipes 4 swipes
Wait
5 seconds
(until fast blinking)
Swipe the Installer Finger 1 to 4 times depending of the desired menu
END END END END
Installer Programming block diagram
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to put the Buzzer ON/OFF
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Only in combination
with DINRTT and RU2
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger
to put the Backlight
ON/OFF
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
11

ADMINISTRATOR PROGRAMMING BY KEYPAD
DINPAD-MDINB100
Programming by keypad can be done only if the DINB100-SA reader is connected to keypad DINPAD-M as shown
in the pictures bellow. The connection is done by the cable provided with the biometric reader. Once connected,
the keypad must be put in slave mode.
Connect both devices with the cable
provided.
Put the keypad in slave mode:
Press B seconds+000000
Press 0
Press 2
Press A to exit
12

ADMINISTRATOR PROGRAMMING BY KEYPAD
Example 1: Add user finger to Relay1 - Press 1234 + A + 1 + 1 + 1 + 01 + A + Enroll finger 6 times. 0A to exit.
Example 2: Add user PIN 147 to Relay2 - Press 1234 + A + 1 + 2 + 2 + 02 + A + 147 + A. 0A to exit.
ENTER ADMIN CODE default: 1234+A
ADD
User
DELETE
PIN Code
PIN Code
Location
DELETE
Finger
FINGER
Location
RELAY 1 RELAY 2 RELAY
1 & 2
MENU
Press 0A to exit the Menu
Press “A”
1
DELETE
User
2
DELETE
ALL
Users
3
ENROLL
Admin Finger
or PIN Code
45
ENROLL
Installer Finger
or PIN Code
1 2 3
CONFIRM ADD
Finger
ADD
PIN Code
ADD
Finger
ADD
PIN Code
1 12 2 1 2
7
01-97 01-97
ADD
Finger
1
FINGER
Location
01-97
Press “A”
ENROLL
Finger
Swipe
the finger
min.
6 times
ADD
PIN Code
2
PIN Code
Location
01-97
Press “A”
PRESS
the
PIN Code
1 to 8
digits
Press “A”
Press “A” Press “A” Press “A” Press “A” Press “A”
ENROLL
Finger
Swipe
the finger
min.
6 times
ENROLL
Finger
Swipe
the finger
min.
6 times
PRESS
the
PIN Code
1 to 8
digits
PRESS
the
PIN Code
1 to 8
digits
x 6
x 6 x 6
Press “A”Press “A”
Press “A”
Press 0A to exit the Menu
Note: The Fingerprint can be deleted by
keypad, only if it is enrolled with keypad.
Note: Entering this menu is done by
admin PIN Code. You can not enter
with Admin Finger.
Exit
multiple beeps
13

INSTALLER PROGRAMMING BY KEYPAD
Example: Change relay1 time to 2 seconds - 5678 + A + 1 + 02 + A.
ENTER INSTALLER CODE
default: 5678+A
Set Relay 1
TIME
MENU
1
Set Relay 2
TIME
2
Press 0A to exit the Menu
Press
01 to 30 for
time in seconds
or
00 for toggle
(ON/OFF) Mode
Backlight
ON/OFF
Buzzer
ON/OFF
34
Press
01 to 30 for
time in seconds
or
00 for toggle
(ON/OFF) Mode
0 = OFF
1 = ON
0 = OFF
1 = ON
Press “A” Press “A” Press “A” Press “A”
Press 0A to exit the Menu
Note: Entering this menu is done by
installer PIN Code. You can not enter
with Installer Finger.
14

15

This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies
with RoHS directive EN50581:2012
16
Northern Office
Videx Security Ltd
Unit 4-7 Chillingham ind Est
Newcastle Upon Tyne
NE6 2XX
Tel: 0870 300 1240
Fax: 0191 224 5678
Southern Office
1 Osprey
Trinity Park
Trinity Way
London
E4 8TD
Fax: 0208 523 5825
Table of contents
Other Videx Security System manuals
Popular Security System manuals by other brands

WirelessAlert
WirelessAlert TextAlert IV user manual

PSG Dover
PSG Dover Wilden SafeGuard Engineering, operation & maintenance

TTK
TTK FG-NET quick start guide

TRE i SYSTEMS
TRE i SYSTEMS DVR-6 user manual

Telect
Telect 009-8005-0404 installation guide

Nortek Security & Control
Nortek Security & Control Numera 2GIG-WMT1-345 installation instructions

Konig
Konig SEC-ALARM200 manual

Brahler
Brahler DIGIMIC CamControl2 Bundle quick guide

Denver
Denver SHA-150 manual

SOMFY
SOMFY PROTEXIOM GSM Installation and operating guide

Honeywell
Honeywell Galaxy Keyprox Installation and programming instructions

Honeywell
Honeywell Friedland HISK1 Quick installation guide