manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Visonic
  6. •
  7. Security Sensor
  8. •
  9. Visonic CLIP-4N User manual

Visonic CLIP-4N User manual

DE1164 CLIP-4N Installation Instructions 1
CLIP
CLIPCLIP
CLIP-
--
-4N
4N4N
4N
The Smallest Digital, Curtain-Type Infrared Detector
Installation Instructions
1. INTRODUCTION
1. INTRODUCTION1. INTRODUCTION
1. INTRODUCTION
The CLIP-4N is the smallest and most elegant curtain-pattern PIR
detector, designed for adjustment-free easy installation. Its function is
based on new, patented digital signal processing.
A new technology is used to include 3 different detectors in a single
case, each programmable for optimized performance at the specific
mounting location. This results in better catch performance and
virtually no false alarms.
The superiority of this detector over similar products is achieved by
applying an improved version of the patented True Motion
Recognition™ (TMR) algorithm. This advanced motion analysis
method allows the CLIP-4N to distinguish between the true motion of
the human body and any other disturbances that cause false alarms.
Detailed coverage patterns and mounting alternatives are given in
Figures 2 through 6 below.
Figure 1. CLIP -4N General View
Figure 2. Wall-Mount Curtain
Figure 3. Ceiling-Mount Curtain
Figure 4. Overhead Curtain
Figure 5. Curtain / Pet Alley
Figure 6. CLIP-4N on Internal Doorframe
2. SPECIFICATIONS
2. SPECIFICATIONS2. SPECIFICATIONS
2. SPECIFICATIONS
OPTICAL
Number of Curtain Beams: 2
Mounting Positions: See Figures 2 through 6.
Mounting Height: Up to 3.6 m (12 ft).
Range: Long, Medium and Short (jumper-selected)
ELECTRICAL
Voltage: 10 to 16 VDC.
Current Drain: About 8 mA at 12 VDC.
Alarm Output: Solid-state relay, N.C., up to 100 ma / 30 V, approx. 30
ohms internal resistance. Circuit opens upon alarm.
Tamper Output: N.C., rated at 50 mA resistive / 30 VDC.
Alarm Duration: 2-3 seconds.
LED: Walk test enabled or disabled with internal link.
Detector: Dual-element low noise pyroelectric sensor.
Microprocessor: 8-bit, low power CMOS.
ENVIRONMENTAL
Operating Temperature: -10°C to 50°C (14°F to 122°F).
Storage Temperature: -20°C to 60°C (-4°F to 140°F).
RFI Protection: > 20 V/m to 1000 MHz.
PHYSICAL
Dimensions (H x W x D): 70 x 28 x 25 mm (2-3/4 x 1-1/4 x 1 in.).
Weight: 25 g (0.9 oz).
Color: White.
PATENTS
U.S. Patent 5,693,943 (other patents pending)
3. INSTALLATION
3. INSTALLATION3. INSTALLATION
3. INSTALLATION
3.1 Disassembly and Assembly
A. Removing the Front Cover
Insert a small screwdriver into
one of the narrow gaps at the
sides of the name plate (see Fig.
7). Lever carefully sideways, until
the name plate arches slightly out
and snaps free (do not let it fly
off). Retain the name plate and
loosen the screw within the inner
shaft (see Fig. 8). Remove the
cover carefully, to avoid dropping
the screw.
Figure 7. Name-Plate Removal
B. Installing the Front Cover
Carefully fit the front cover onto
the base, with the lens in front of
the sensor, insert the screw into
its shaft and tighten it well.
Position the name plate correctly,
and insert one of the tabs into its
groove. Press the free edge
sideways against the already
seated edge, until the name plate
arches slightly outward. Then
force the other tab into its groove,
and let the name plate snap into
place.
Figure 8. Disassembly
2 DE1164 CLIP-4N Installation Instructions
3.2 ounting
The CLIP-4N may be mounted in various positions on walls, ceilings
and door frames (see Figures 2 to 6).
CAUTION! To prevent false alarms caused by external temperature
changes and sudden air gusts, detectors should not be mounted on or
within window frames built into external walls. Moreover, it is
mandatory to seal the wiring entry holes with sealing compound such
as RTV, thus protecting the sensor from insects and air currents.
A. Select the mounting location so that the expected motion of an
intruder will cross the curtain beams.
B. When mounting on the ceiling (Figure 3), the ceiling height must
not exceed 3.6 m (12 ft). The maximum detection distance is 6 m
(20 ft), and the curtain width at that distance is 1.3 m (4.5 ft).
C.To minimize false alarms, it is
advisable to avoid aiming the
detector at heaters, sources
of light, or windows subjected
to direct sunlight. Also avoid
running wiring close to high
power electrical cables.
D. Remove the front cover as
instructed in Para. 3.1A.
E. Mount the base with the PCB
at the location and height that
gives optimum coverage. Use
the two mounting knock- outs
(see Fig. 9).
F. Always install the unit on a
firm and stable surface.
Figure 9. Inside the CLIP -4N
3.3 Wiring
To route wires into the detector, use the wiring knockout located at
the top left of the unit base (Figure 9). Since the knockout is angular,
the wiring may be inserted from behind the base or from the top, as
required for the particular installation. Refer to Fig. 10 and connect
wires to the terminal block in the following order:
A. Connect terminals 5 and 6
(the tamper N.C. terminals)
to a normally closed 24-
hour protective loop of the
control panel. The tamper
contacts will open when the
cover is removed
.
Figure 10. Terminal Block Wiring
B. Connect terminals 1 & 2 (the relay N.C. terminals) to a normally
closed protective loop of the control panel. The alarm output
circuit will open when motion is detected or during power loss.
C. Connect terminals 3 (–) and 4 (+) to a 10 to 16 Volt DC power
source (observe polarity). The power supply must have battery
backup. The current drain of each unit is approximately 12.5 mA.
D. It is advisable to seal all openings properly after installation.
3.4 Setting the Coverage Range
A 3-pin jumper is used to select 3 coverage ranges for the curtain
beams (see Figure 11). The jumpers are shown as seen when the
detector is positioned with its terminal block up (refer to Figure 9).
Figure 11. Coverage Range Jumper Settings
The purpose of the range setting is is to ensure optimal signal
processing and high immunity against false alarms.
Mount the range jumper in the desired position and make sure that
the protected area is within the selected coverage range. Carry out a
walk test (refer to Para. 3.5 below) to verify proper performance.
3.5 Walk Testing
A. Apply 12 VDC and allow 1 minute for warming up and stabilizing.
B. Walk slowly across the curtain pattern (in opposite directions).
The LED lights whenever you enter or exit a curtain beam. Allow 5
seconds between each test for the unit to stabilize.
C. After testing, you may disable the LED to prevent unauthorized
tracing the coverage pattern. Remove the LED jumper from its
position across the 2 pins and install it on one of the pins.
Note: The range and coverage area should be checked at least
once a year. To assure proper continuous functioning, the user
should be instructed to perform a walk test at the far end of the
coverage pattern to assure an alarm signal prior to each time the
alarm system is armed.
This device has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in residential installations. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio and television reception. However, there is no guarantee that
interference will not occur in a particular installation. If this device does cause such
interference, which can be verified by turning the device off and on, the user is
encouraged to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one which
supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
WARNING! Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
WARRANTY
WARRANTYWARRANTY
WARRANTY
Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original
purchaser only (the “Purchaser”) against defective workmanship and materials under normal use of
the Product for a period of twelve (12) months from the date of shipment by the Manufacturer.
This Warranty is absolutely conditional upon the Product having been properly installed, maintained
and operated under conditions of normal use in accordance with the Manufacturers recommended
installation and operation instructions. Products which have become defective for any other reason,
according to the Manufacturers discretion, such as improper installation, failure to follow
recommended installation and operational instructions, neglect, willful damage, misuse or vandalism,
accidental damage, alteration or tampering, or repair by anyone other than the manufacturer, are not
covered by this Warranty.
The Manufacturer does not represent that this Product may not be compromised and/or
circumvented or that the Product will prevent any death and/or personal injury and/or damage to
property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases
provide adequate warning or protection. The Product, properly installed and maintained, only
reduces the risk of such events without warning and it is not a guarantee or insurance that such
events will not occur.
THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES,
OBLIGATIONS OR LIABILITIES, WHETHER WRITTEN, ORAL, EXPRESS OR IMPLIED,
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, OR OTHERWISE. IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO
ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS
WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS AFORESAID.
THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS, DAMAGE, OR
EXPENSE, INCLUDING LOSS OF USE, PROFITS, REVENUE, OR GOODWILL, DIRECTLY OR
INDIRECTLY ARISING FROM PURCHASER’S USE OR INABILITY TO USE THE PRODUCT, OR
FOR LOSS OR DESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE, EVEN
IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH, PERSONAL AND/OR
BODILY INJURY AND/OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT,
INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT THE
PRODUCT FAILED TO FUNCTION.
However, if the M
anufacturer is held liable, whether directly or indirectly, for any loss or damage
arising under this limited warranty, the Manufacturer's maximum liability (if any) shall not in any case
exceed the purchase price of the Product, which shall be fixed as liquidated damages and not as a
penalty, and shall be the complete and exclusive remedy against the Manufacturer.
When accepting the delivery of the Product, the Purchaser agrees to the said conditions of sale and
warranty and he recognizes having been informed of.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so
these limitations may not apply under certain circumstances.
The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or
malfunctioning of any telecommunication or electronic equipment or any programs.
The Manufacturers obligations under this Warranty are limited solely to repair and/or replace at the
Manufacturer’s discretion any Product or part thereof that may prove defective. Any repair and/or
replacement shall not extend the original Warranty period. The Manufacturer shall not be
responsible for dismantling and/or reinstallation costs. To exercise this Warranty the Product must
be returned to the Manufacturer freight pre-paid and insured. All freight and insurance costs are the
responsibility of the Purchaser and are not included in this Warranty.
This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize
any person to act on its behalf in the modification, variation or extension of this warranty. This
warranty shall apply to the Product only. All products, accessories or attachments of others used in
conjunction with the Product, including batteries, shall be covered solely by their own warranty, if
any. The Manufacturer shall not be liable for any damage or loss whatsoever, whether directly,
indirectly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to
products, accessories, or attachments of others, including batteries, used in conjunction with the
Products. This Warranty is exclusive to the original Purchaser and is not assignable.
This Warranty is in addition to and does not affect your legal rights. Any provision in this warranty
which is contrary to the Law in the state or country were the Product is supplied shall not apply.
Warning:The user must follow the Manufacturer’s installation and operational instructions including
testing the Product and its whole system at least once a week and to take all necessary precautions
for his/her safety and the protection of his/her property.
1/08
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Di
rective 2002/96/EC Waste Electrical and Electronic Equipment
.
EMAIL: [email protected]
INTERNET: www.visonic.com

VISONIC LTD. 20
14
CLIP
-
4N DE1164
-
(REV.
3, 1
/
1
4
)

Other Visonic Security Sensor manuals

Visonic SPD-1000 User manual

Visonic

Visonic SPD-1000 User manual

Visonic MCT-340 SMA User manual

Visonic

Visonic MCT-340 SMA User manual

Visonic DUO 240 - INSTALLER GUIDE User manual

Visonic

Visonic DUO 240 - INSTALLER GUIDE User manual

Visonic NEXT CAM PG2 User manual

Visonic

Visonic NEXT CAM PG2 User manual

Visonic CLIP SMA User manual

Visonic

Visonic CLIP SMA User manual

Visonic NEXT DUO User manual

Visonic

Visonic NEXT DUO User manual

Visonic TOWER 10 AM - User manual

Visonic

Visonic TOWER 10 AM - User manual

Visonic MCT-350 User manual

Visonic

Visonic MCT-350 User manual

Visonic SD-304C PG2 User manual

Visonic

Visonic SD-304C PG2 User manual

Visonic MCT-425 User manual

Visonic

Visonic MCT-425 User manual

Visonic DUET User manual

Visonic

Visonic DUET User manual

Visonic TOWER-32AMPG2 User manual

Visonic

Visonic TOWER-32AMPG2 User manual

Visonic XHS1-TY User manual

Visonic

Visonic XHS1-TY User manual

Visonic SPY 1 User manual

Visonic

Visonic SPY 1 User manual

Visonic K-940 User manual

Visonic

Visonic K-940 User manual

Visonic MCW User manual

Visonic

Visonic MCW User manual

Visonic K-980W User manual

Visonic

Visonic K-980W User manual

Visonic MP-840 User manual

Visonic

Visonic MP-840 User manual

Visonic MCW-570 User manual

Visonic

Visonic MCW-570 User manual

Visonic NEXT K9-85 MCW User manual

Visonic

Visonic NEXT K9-85 MCW User manual

Visonic Logica User manual

Visonic

Visonic Logica User manual

Visonic NEXT PLUS Series User manual

Visonic

Visonic NEXT PLUS Series User manual

Visonic MCT-560 User manual

Visonic

Visonic MCT-560 User manual

Visonic GLASSTECH User manual

Visonic

Visonic GLASSTECH User manual

Popular Security Sensor manuals by other brands

WindowMaster WSK 320 manual

WindowMaster

WindowMaster WSK 320 manual

HomeMatic HM-Sen-MDIR-O-2 manual

HomeMatic

HomeMatic HM-Sen-MDIR-O-2 manual

Protecto F-SAFE Series Installation and operating manual

Protecto

Protecto F-SAFE Series Installation and operating manual

Lornet LORNET-24 user manual

Lornet

Lornet LORNET-24 user manual

EDTM ShowerGuard RD1661 Operator's manual

EDTM

EDTM ShowerGuard RD1661 Operator's manual

STEINEL StudioLine IS 2160 operating instructions

STEINEL

STEINEL StudioLine IS 2160 operating instructions

SUTO S 530 Instruction and operation manual

SUTO

SUTO S 530 Instruction and operation manual

Elcometer 270 user guide

Elcometer

Elcometer 270 user guide

System Sensor 5451 Installation and maintenance instructions

System Sensor

System Sensor 5451 Installation and maintenance instructions

Vivitar WT-09 user manual

Vivitar

Vivitar WT-09 user manual

smartmicro UMRR-11 45 user manual

smartmicro

smartmicro UMRR-11 45 user manual

steute Ex RC Si 56-3G/D Mounting and wiring instructions

steute

steute Ex RC Si 56-3G/D Mounting and wiring instructions

Elkron ELKEIR600 Installation, programming and functions manual

Elkron

Elkron ELKEIR600 Installation, programming and functions manual

PCB Piezotronics 4105-07A Installation and operating manual

PCB Piezotronics

PCB Piezotronics 4105-07A Installation and operating manual

Bierer VD1000 operating instructions

Bierer

Bierer VD1000 operating instructions

PNI SAFE HOUSE PG07 user manual

PNI

PNI SAFE HOUSE PG07 user manual

UE Systems ULTRAPROBE 2000 instruction manual

UE Systems

UE Systems ULTRAPROBE 2000 instruction manual

netvox S31501 user manual

netvox

netvox S31501 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.