DE1161 3
:LULQJ
To route wires into the detector, use the wiring knockout located
at the top left of the unit base (Figure 12).
Since the knockout is
angular, the wiring may be
inserted from behind the
base or from the top, as
required for the particular
installation. Refer to Fig. 13
Figure 13. Terminal Block Wiring
and connect wires to the terminal block in the following order.
A. Connect terminals 5 and 6 – the tamper N.C. terminals – to a
normally closed 24-hour protective loop of the control panel.
The tamper contacts will open when the cover is removed.
B. Connect terminals 1,2 (the relay N.C. terminals) to a normally
closed protective loop of the control panel. The relay contacts
will open when motion is detected or during power loss.
C. Connect terminals 3 (–) and 4 (+) to a 10 to 16 Volt DC power
source, making sure that the polarity is correct. It is
mandatory that the power supply have battery backup.
Current drain of each CLIP PIR is approximately 12.5 mA.
9HUWLFDO$GMXVWPHQW
The vertical adjustment scale (printed on the lower left corner of
the PCB) and the plastic pointer on the base indicate in degrees
the approximate vertical angle between the horizontal line of the
unit and the upper detection layer.
Table 1 gives the recommended scale adjustment for various
combinations of mounting height and coverage distance. The
scale permits fast, easy pattern adjustment from 0° to -12°
downward according to the installation height and the required
coverage range.
The sensors are preset to -4°. To change the vertical pattern
adjustment, remove the cover, hold the terminal block with two
fingers and slide the PCB up or down to the desired angle.
Caution! CLIP is a delicate device due to its small size. Do
not exert force on any component other than the terminal
block. Failure to observe this may damage the detector.
The friction on the PCB should be enough to maintain the new
position until you remount the front cover and tighten the screw.
Tightening the screw exerts additional pressure on the plastic
bushing which binds the p.c. board to the back cover.
Note: Since the beam width increases with distance from the
detector, an inverted (lens up) installation of the CLIP-2 (Pet Alley
model ) is advisable in certain cases. Set the scale between -4°
and -6°, to obtain the desired pet alley height.
Table 1. Vertical Adjusting Scale
&/,33XOVH&RXQWHU
The CLIP PIRs are equipped with a programmable pulse counter
which can be set to count 1 or 2 pulses with alternate polarity,
before activating the alarm relay. To set the pulse counter, place
the jumper at the desired setting (ON or OFF).
ON (2 pulses). This setting provides improved protection against
false alarms caused by all types of environmental disturbances. It
should only be used in temperature controlled locations (less than
30°C / 86°F).
OFF (1 Pulse). This setting actually disables the pulse counter. It
should be used when it is necessary to activate an alarm on the
first detected pulse, or in high security installations, when fast
"catch" performance is of greatest importance.
:DON7HVWLQJ
A. Apply 12 VDC power and allow five minutes for the unit to
warm up and stabilize.
B. Adjust the vertical calibration angle according to Table 1.
C. Set the pulse counter per Para. 3.5 above.
D. Walk-test the range and coverage area by walking slowly
across the field of view (in opposite directions) and observe
the LED. The LED lights up whenever you enter or exit a
sensitive beam. Allow 5 seconds between each test for the
unit to stabilize.
E. After testing, the LED can be disabled to prevent unauthorized
persons from tracing the coverage pattern. To disable the
LED, remove the LED jumper from its position across the 2
pins and install it on one of the pins to prevent losing it.
Note: The range and coverage area should be checked at least
once a year. To assure proper continuous functioning, the user
should be instructed to perform a walk test at the far end of the
coverage pattern to assure an alarm signal prior to each time the
alarm system is armed.
:$55$17<
:$55$17<
Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its
products hereinafter referred to as "the Product" or "Products" to be in conformance with
its own plans and specifications and to be free of defects in materials and workmanship
under normal use and service for a period of twelve months from the date of shipment by
the Manufacturer. The Manufacturer's obligations shall be limited within the warranty
period, at its option, to repair or replace the product or any part thereof. The Manufacturer
shall not be responsible for dismantling and/or reinstallation charges. To exercise the
warranty the product must be returned to the Manufacturer freight prepaid and insured.
This warranty does not apply in the following cases: improper installation, misuse,
failure to follow installation and operating instructions, alteration, abuse, accident or
tampering, and repair by anyone other than the Manufacturer.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or
liabilities, whether written, oral, express or implied, including any warranty of
merchantability or fitness for a particular purpose, or otherwise. In no case shall the
Manufacturer be liable to anyone for any consequential or incidental damages for breach
of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall not be modified, varied or extended, and the Manufacturer does not
authorize any person to act on its behalf in the modification, variation or extension of this
warranty. This warranty shall apply to the Product only. All products, accessories or
attachments of others used in conjunction with the Product, including batteries, shall be
covered solely by their own warranty, if any. The Manufacturer shall not be liable for any
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or
otherwise, caused by the malfunction of the Product due to products, accessories, or
attachments of others, including batteries, used in conjunction with the Products.
The Manufacturer does not represent that its Product may not be compromised and/or
circumvented, or that the Product will prevent any death, personal and/or bodily injury
and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the
Product will in all cases provide adequate warning or protection. User understands that a
properly installed and maintained alarm may only reduce the risk of events such as
burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such
will not occur or that there will be no death, personal damage and/or damage to property
as a result.
The Manufacturer shall have no liability for any death, personal and/or bodily injury
and/or damage to property or other loss whether direct, indirect, incidental,
consequential or otherwise, based on a claim that the Product failed to function.
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of cause or origin, the
Manufacturer's maximum liability shall not in any case exceed the purchase price of the
Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the
complete and exclusive remedy against the Manufacturer.
Warning: The user should follow the installation and operation instructions and among
other things test the Product and the whole system at least once a week. For various
reasons, including, but not limited to, changes in environmental conditions, electric or
electronic disruptions and tampering, the Product may not perform as expected. The user
is advised to take all necessary precautions for his /her safety and the protection of
his/her property. 6/91
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): 10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISONIC LTD. (UK): UNIT 1, STRATTON PARK, DUNTON LANE, BIGGLESWADE, BEDS. SG18 8QS. PHONE: (01767) 600857 FAX: (01767) 601098
VISONIC LTD. 1998 CLIP D-1161-0 NEW: DE1161- (REV. 1 ,4/98).