DE1606 3
to 16 Volt DC power source and check for correct polarity.
It is advisable that the power supply be battery backed-up.
Current drain of each sensor is approximately 15 mA.
9HUWLFDO$GMXVWPHQW
The vertical adjustment scale (printed on the upper right corner of
the p.c. board) and the plastic pointer on the base indicate in
degrees the approximate vertical angle between the horizontal
line of the unit and the upper detection layer.
Table 1 gives the recommended scale adjustment for various
combinations of mounting height and coverage distance. The
scale enables fast, easy pattern adjustment from 0° to -12°
downward according to the installation height and the required
coverage range.
Table 1. Vertical Adjusting Scale
All QUATRO+ sensors are factory preset to -4°. To change the
vertical pattern adjustment, loosen the screw which fastens the
printed circuit board to the rear cover. Slide the p.c. board up or
down to the desired angle and tighten the screw firmly.
In operation, a person must cross both the upper and lower PIRs
together to initiate an alarm (Fig. 1).
It is of utmost importance that a walk test be made over the entire
coverage area to assure that both upper and lower beams will be
crossed. This is of particular importance when using the long
range lens (Lens B).
48$7523XOVH&RXQWHU
The QUATRO+ QUAD PIR is equipped with two independent
alternate polarity pulse count circuits and controls (Fig. 6).
The Upper Detector (1) is controlled with pulse count switch 1.
The Lower Detector (2) is controlled with pulse count switch 2.
Placing both switches to ON selects the alternate polarity pulse
count operation for both detectors. A person is required to cross
both the (+) and (–) beams of both dual element detectors (1 and
2) before activation of the alarm relay. This means that motion
must be detected by all 4 beams (Fig. 1). Use of the pulse count
is recommended only in a temperature controlled environment
where the temperature does not exceed 28°C (82°F).
Placing both switches at OFF actually disables the pulse counters
of both detectors. This should be done if it is necessary to
activate an alarm in the first crossing of a vertical pair of beams,
such as with a long range lens or in high security installations
when high 'catch' performance is required. Still, both detectors
(one beam each) must be triggered.
To ensure proper detection when using the long range lens, pulse
count one must be selected for both the upper and lower
detectors. Set both switches to OFF.
With two pulse count switches you can select pulse count
operation on only one detector (1 or 2). This flexibility may prove
useful in certain applications which require different catch
performance levels in the same area.
:DON7HVWLQJ
A. Apply 12 VDC power and allow five minutes for the unit to
warm up and stabilize before testing.
B. Adjust the vertical pattern angle according to Table 1.
Note: be careful to position the printed circuit board so that
the upper and lower beams reach the maximum required
distance. This can be achieved by careful vertical adjustment
and walk testing.
C. Place the LED jumper at ON (across the middle and top pins)
to activate the LED.
D. Set the pulse counter per para 3.6 above.
E. Walk-test the range and coverage area by walking slowly
across the field of view (in opposite directions) and observe
the LED. The LED lights up whenever you cross a pair of
vertical sensitive beams. Allow 10 seconds between each test
for the unit to stabilize.
F. After testing, the LED can be disabled to prevent unauthorized
persons from tracing the coverage pattern. To disable the
LED, remove the LED jumper from the ON position (across
the middle and upper pins) and place it in the OFF position
(across the middle and lower pins).
NOTE: The range and coverage area should be checked at
least once a year. To assure proper continuous functioning,
the user should be instructed to perform a walk test at the far
end of the coverage pattern to assure an alarm signal.
:$55$17<
:$55$17<
Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its
products hereinafter referred to as "the Product" or "Products" to be in conformance with
its own plans and specifications and to be free of defects in materials and workmanship
under normal use and service for a period of twelve months from the date of shipment by
the Manufacturer. The Manufacturer's obligations shall be limited within the warranty
period, at its option, to repair or replace the product or any part thereof. The Manufacturer
shall not be responsible for dismantling and/or reinstallation charges. To exercise the
warranty the product must be returned to the Manufacturer freight prepaid and insured.
This warranty does not apply in the following cases: improper installation, misuse,
failure to follow installation and operating instructions, alteration, abuse, accident or
tampering, and repair by anyone other than the Manufacturer.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or
liabilities, whether written, oral, express or implied, including any warranty of
merchantability or fitness for a particular purpose, or otherwise. In no case shall the
Manufacturer be liable to anyone for any consequential or incidental damages for breach
of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall not be modified, varied or extended, and the Manufacturer does not
authorize any person to act on its behalf in the modification, variation or extension of this
warranty. This warranty shall apply to the Product only. All products, accessories or
attachments of others used in conjunction with the Product, including batteries, shall be
covered solely by their own warranty, if any. The Manufacturer shall not be liable for any
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or
otherwise, caused by the malfunction of the Product due to products, accessories, or
attachments of others, including batteries, used in conjunction with the Products.
The Manufacturer does not represent that its Product may not be compromised and/or
circumvented, or that the Product will prevent any death, personal and/or bodily injury
and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the
Product will in all cases provide adequate warning or protection. User understands that a
properly installed and maintained alarm may only reduce the risk of events such as
burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such
will not occur or that there will be no death, personal damage and/or damage to property
as a result.
The Manufacturer shall have no liability for any death, personal and/or bodily injury
and/or damage to property or other loss whether direct, indirect, incidental,
consequential or otherwise, based on a claim that the Product failed to function.
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of cause or origin, the
Manufacturer's maximum liability shall not in any case exceed the purchase price of the
Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the
complete and exclusive remedy against the Manufacturer.
Warning: The user should follow the installation and operation instructions and among
other things test the Product and the whole system at least once a week. For various
reasons, including, but not limited to, changes in environmental conditions, electric or
electronic disruptions and tampering, the Product may not perform as expected. The user
is advised to take all necessary precautions for his /her safety and the protection of
his/her property. 6/91
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): 10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISONIC LTD. (UK): UNIT 1, STRATTON PARK, DUNTON LANE, BIGGLESWADE, BEDS. SG18 8QS. PHONE: (01767) 600857 FAX: (01767) 601098
VISONIC LTD. 1998 QUATRO+ D-1606-0 NEW: DE1606- (REV. 1, 4/98)