3/3
461 317
1/2
Brake Valve
© 2005 American Standard All rights reserved 461 317 961 3/09.2005
– Check exhaust of the device for tightness.
No leakages admissible.
3.2 Complete device
– Fix degree scale to device.
0-position of the pedal means 0-position of
the graduation at the same time.
– Adjust pedal to G1 (stop within device).
Gauges 3 and 4 must indicate P2.
– Cover complete device with soap and check
tightness.
No leakages admissible.
With soap bubbling the device is not tight.
– Re-adjust pedal to 0°.
Gauges 3 and 4 must indicate 0 bar.
4. Obtain maximum pressure
– Adjust pedal to G1 (stop within device).
Pressure must increase immediately.
Gauges 3 and 4 must indicate P2.
– Re-adjust pedal to 0°.
Gauges 3 and 4 must indicate 0 bar.
5. Graduability
In all pressure scopes incremental steps of
max. 0.2 bar must be possible.
6. Check pressure increase
– Operate pedal several times.
Gauges 3 and 4 must indicate immediate
pressure increase resp. decrease.
In accordance with the type of device, one cir-
cuit must have predominance.
6.1 Check sudden pressure increase
– Adjust pedal to G2.
Gauge 3 must indicate P3.
Gauge 4 must indicate P4.
6.2 Distance until venting of P5/P6
– Adjust pedal to G3.
Pressure must increase immediately.
Gauge 3 must indicate P5.
Gauge 4 must indicate P6.
6.3 Distance until venting of P7/P8
– Adjust pedal to G4.
Pressure must increase immediately.
Gauge 3 must indicate P7.
Gauge 4 must indicate P8.
6.4 Distance until venting of P2
– Adjust pedal to G1.
Pressure must increase immediately.
Gauges 3 and 4 must indicate P2.
– Re-adjust pedal to 0°.
Gauges 3 and 4 must indicate 0 bar.
7. Failure of circuit 1
– Vent port 11 to 0 bar.
Gauge 1 must indicate 0 bar.
Gauge 2 must indicate P1.
– Adjust pedal to G5.
Gauge 3 must indicate 0 bar.
Gauge 4 must indicate P9.
– Re-adjust pedal to 0°.
Gauges 3 and 4 must indicate 0 bar.
8. Completion of test
– Vent port 12 to 0 bar.
Gauges 1 and 2 must indicate 0 bar.
Do not disconnect the hose connections until you
have vented the device to 0 bar.
– Remove device from fixture.
– Clean device.
i
i
i
i
i
i
i
i
i