Wassermann SG-10 User manual

Suction Unit
SG-10
Single Workbench Suction Unit
USER MANUAL
SG-10
Activated Carbon
Version
(REF 140987)
fig. with accessory
external spee regulator
SG-10
Basic Version
(REF 140988)
fig. with accessory
external spee regulator

ear customer,
Thank you for choosing a pro uct from the Wassermann range. Wassermann Dental-
Maschinen incorporates the highest stan ar s of quality an the latest technology.
In or er to enjoy maximum performance an years of trouble-free operation, please rea
this user manual carefully before you connect this evice an start work, an operate the
evice accor ing to the recommen e gui elines. The operation safety an the
functionality of this evice can only be guarantee if you follow both the general safety
gui elines an the applying laws to prevent acci ents as well as the precautions given in
this user manual. We are not liable for any amages which occur ue to inappropriate
usage or faulty operation of this evice.
Make sure that anyone using this evice has rea an un erstoo this user
manual.
Keep this user manual in a safe place where it can be referre to as require at
any time.
The unit complies with the relevant EU gui elines.
The unit is subject to the EU gui elines 2012/19/EU (WEEE Directive).
Company address:
Wassermann Dental-Maschinen GmbH
Ru orffweg 15-17
21031 Hamburg, Germany
Phone : +49 (0)40 730 926 -20/ -24 Fax.: +49 (0)40 730 37 24
export@wassermann- ental.com
www.wassermann.hamburg
www.facebook.com/WassermannDentalmaschinen
Erstellt: 03.09.20/ msc Version: 2 Auftrag: 140988 // 140987 ab #00168724
.

Contents
1 Features............................................................................................................................4
2 Safety Symbols use in this Manual.................................................................................4
3 Safety Gui elines..............................................................................................................5
4 Responsibility for Operation or Damage...........................................................................5
5 Application.........................................................................................................................6
6 Before Starting..................................................................................................................6
6.1 Transport....................................................................................................................6
6.2 Installation..................................................................................................................7
6.3 Storage.......................................................................................................................7
7 Installation/ Start-up..........................................................................................................7
8 Operation..........................................................................................................................8
8.1 General Operating Instructions..................................................................................8
9 Troubleshooting................................................................................................................9
10 Care an Maintenance..................................................................................................10
10.1 Cleaning.................................................................................................................10
10.2 Maintenance...........................................................................................................10
10.2.1 Replacing the filter...........................................................................................10
10.3 Repairs...................................................................................................................11
10.4 Spare Parts.............................................................................................................11
10.5 Service Hotline 0049 (0)40 730 926 -20/ -24.........................................................11
10.6 Scope of Delivery/ Accessories..............................................................................12
10.6.1 Use of the Filter Extension Mo ule.................................................................13
10.6.2 Operating with Activate Carbon Filter Slot....................................................14
10.7 Warranty.................................................................................................................15
11 Technical Data..............................................................................................................15
12 Technical Drawings.......................................................................................................16
12.1 Construction SG-10 (incl. Activate Carbon Filter)................................................16
12.2 Construction Mo ule Activate Carbon Filter (REF: 140424)................................17
13 Disposing of the Unit.....................................................................................................18
13.1 Information on Disposal for Countries within the EU.............................................18
14 EU Declaration of Conformity.......................................................................................19

1 Features
The suction unit SG-10 is use to extract ental ust at the workplace an to extract
polishing ust an fine blasting units.
•Universal suction unit works with the low pressure principle
•Single workbench suction unit
•Power control is infinitely variable using the control element on the housing
(an external control element can be retrofitte , accessory item no.140408)
•Mo ular filter system for ifferent uses
•Innovative filter concept, easy-to-replace filter system
•Filter saturation isplay
•Other filters available: from the activate carbon filter to the high-volume plaster
pre-filter
•Suitable for continuous operation
•High-quality finish
•Free from wear an maintenance-free
•Recommen e version for our fine blasting units
2 Safety Symbols used in this Manual
Warning!
This is a warning of risk situations an angers.
Failure to observe this warning coul be life-threatening. These warnings has to
be observe .
Information!
This symbol raws your attention to specific features that has to be observe .
4

3 Safety Guidelines
Configuring an operating this equipment requires precise knowledge an observance
of the instructions in this user manual. The equipment is esigne only for its inten e
application.
WARNING:
Servicing an repairs shoul be carrie out only by authorise specialists.
Disconnect the power plug before starting any maintenance work.
Make sure that the equipment is connecte to the correct power source.
Do not operate the unit without a fan guar or a filterbag! Do not operate the
SG-10 in an explosive atmosphere! Do not apply suction to any liqui s.
4 Responsibility for Operation or amage
The responsibility for operating the evice lies exclusively with the owner or user if sai
evice is incorrectly service , maintaine or altere by persons not employe by an
authorise ealer or if the evice is use in a manner contrary to its specifie purpose.
The unit has to be maintaine an operate in accor ance with this user manual.
Wassermann Dental-Maschinen GmbH is not responsible for amage arising from the
nonobservance of these instructions.
Warranty an responsibility provisions containe in the sales an supply con itions of
Wassermann Dental-Maschinen GmbH are not exten e by these instructions.
5

5 Application
The suction unit SG-10 is versatile in use, e.g. at ental technician workplaces, with
blasting units (e.g. Cemat NT, Puna) or with a polishing splash guar .
Maximum air extraction at low air spee is guarantee . Only respirable suspen e soli s
are extracte .
The benefits this provi es are practically silent operation of the fan motor an quiet
running ue to the low flow spee of the extracte air. The slow air flow means that even
uring work over longer perio s, the han s o not chill.
The SG-10 has an rotary potentiometer for fan control an a pilot lamp to in icate filter
saturation on the housing.
A itionally, the unit's mo ular structure permits operation with activate carbon an /or a
pre-filter setting, e.g. for larger quantities of plaster. Furthermore, a specially evelope
suction hoo is available for the ental technician workplace, hence optimising the suction
performance.
Only use the evice for this type of application.
6 Before Starting
6.1 Transport
Before transporting the unit, ensure that it has been unplugge from the power socket.
Make sure that it is packe correctly in or er to avoi acci ental amage.
Be sure to check for any transport amage when unpacking the goo s. Note own
any amage if foun .
6

6.2 Installation
Open the box, remove the packing materials, an carefully lift out the evice an
accessories. Check the inclu e accessories.
The evice has to stan horizontally on a stea y an even surface.
Install the evice in a place where it will not block the working area an the
functionality (take the imensions into account). Make sure that there are about
10 cm of free space on rear si e to guarantee air circulation (heat issipation).
Do not install the unit out oors or in places without proper ventilation.
Before start-up, be sure the evice reaches room temperature.
6.3 Storage
The unit location is very important when it comes to workplace safety, even if it is only to
be set up there for a short perio . The room shoul be ry, well ventilate an vibration-
free. An even temperature an woo en supports also help. The unit shoul not be store
or set up out oors. If the unit is to be store for an exten e perio , protect it from
moisture an ust.
7 Installation/ Start-up
1. Remove the supply line from the filter below the li .
2. Make an electric connection.
3. Insert the power plug into the socket, making sure that the mains an the unit
operate on the same voltage.
7

8 Operation
8.1 General Operating Instructions
All instructions for using the unit, whether in verbal or written form, are base on our own
experience an experimentation an can only be regar e as gui elines.
1. The unit can be switche on an off by pressing the rocker switch on the supply
line.
2. A rotary potentiometer for fan control is locate on the left si e of the housing. Start
the fan an set the esire level by turning the control element. It can also be use
to briefly stop the fan.
3. Use the rocker switch to eactivate the SG-10 uring longer interruptions in work.
You have to press the rocker switch on the supply line in or er to eactivate the
unit!
The control element can be use to stop the fan, but the unit itself is not switche
off!
elayed fan start-up is a feature of this series an permits maintenance-free
operation an a longer service life.
8

9 Troubleshooting
Fault Cause Solution
Filter saturation
– re lamp glows
Full filter Replacing the filter (see 8.2.1)
Motor control oes not
work
Damage
potentiometer
(spee control)
Please contact our service epartment
Full filter – but re lamp
oes not glow
Damage lamp Please contact our service epartment
Damage ifferential
pressure switch
Empty filter – but re
lamp alrea y glows
Damage ifferential
pressure switch
Please contact our service epartment
If the above recommen ations o not solve the problem, contact your ental epot
or our service epartment.
9

10 Care and Maintenance
10.1 Cleaning
Disconnect the power plug before starting any maintenance work.
The i entification plate has always to be kept in easily legible con ition an has
not to be remove .
Remove external irt from time to time with some form of col cleaner.
Use only col cleaners to avoi amaging the paintwork or removing the lettering.
The equipment shoul be cleane at regular intervals to ensure trouble-free
operation.
It requires only normal cleaning (sponge, amp cloth, mil etergent) an no further
chemical a itives.
10.2 Maintenance
The unit oes not require any servicing. Just make sure that the evice is kept clean.
10.2.1 Replacing the filter
Replacing the filter is part of the maintenance work.
Please replace the filter in the event that the suction performance falls noticeably, an
certainly when the pilot lamp lights up.
Regular filter replacement is necessary to ensure maximum ust extraction. The red
pilot lamp for filter saturation was set to maximum suction performance. It simply
indicates that the filter should be replaced; it oes not eactivate the fan.
10

A isposable micro fine ust filterbag is fitte ; it must be replace when ust saturation
(red pilot lamp) is reache .
To o this, open the fasteners on the right an the left, remove the li , take out the
filterbag an wrap in the a hesive foil enclose with the spare filter. Insert the new filter,
close the li .
Depen ing on their use, activate carbon filters shoul be replace when
necessary, but after no later than 4 to 6 months. The filter cassette ust class M
(secon ary filter) shoul be replace epen ing on its use (recommen ation: use
for no more than 12 months).
10.3 Repairs
Servicing or repairs to the unit has only to be carrie out by qualifie technicians.
Only original spare parts are to be use . Responsibility for the pro uct is voi e
if unauthorise persons alter it or if inappropriate components are installe .
10.4 Spare Parts
If necessary please contact our service hotline phone.
10.5 Service Hotline 0049 (0)40 730 926 -20/ -24
11

10.6 Scope of elivery/ Accessories
Included parts Item no.
SG-10 basic version 140988
Suction unit SG-10 base 140980
Supply line with switchable shock proof plug 140022
Micro fine ust filterbag (yellow) small, ust class M ---
Included parts Item no.
SG-10 activate carbon version 140987
Suction unit SG-10 base 140980
Supply line with switchable shock proof plug 140022
Micro fine ust filterbag (yellow) large, ust class M 610074
Filter extension mo ule (without filter) 140410
Mo ule activate carbon filter (with filter) 140424
Accessories: Item no.
Spare micro fine ust filterbag (yellow) small, ust class M, 1 set = 4 pieces 611010
Spare filterbag for plaster (white) small, class 1 / class 2, 1 set = 4 pieces 611018
Spare micro fine ust filterbag (yellow) large, ust class M * 610074
Spare filterbag for plaster (white) large, class 1 / class 2 * 610073
Spare filter cassette, ust class F, cpl.* 140435
Spare activate carbon filter, cpl.*140436
Mo ule filter a -on (without filter) 140410
Mo ule activate carbon filter (with filter) 140424
External spee regulator for fan control, can be retrofitte
(accessory SG-10 #00168724 ff.)
140408
* (only SG-10 activate carbon version)
Item numbers for setup change SG-10 basic into activated carbon version:
140410/ 610074/ 140424
12

10.6.1 Use of the Filter Extension Module
In or er to fit a larger filterbag or the activate carbon filter, please use the filter extension.
To o this, open the fasteners on the right an the left, take off the li , insert the filter
extension an close the fasteners.
Insert the new filter (e.g. plaster filterbag, long) into the filter extension, replace the li an
close using the fasteners on the right an the left.
13

10.6.2 Operating with Activated Carbon Filter Slot
In or er to insert the activate carbon filter unit into the evice, please first remove the ol
filterbag (as escribe un er item 8.2.1).
After this, insert the slot alrea y fitte with filters into the unit an fit the interme iate
frame.
Then fit the filter extension to the unit (see item 8.5.1), insert the pre-filter (filterbag ust
class M, long 340 mm) an close the li .
In or er to replace the activate carbon filter while using the SG-10, please remove the
activate carbon filter slot from the unit an replace the use filters.
When fitting, resp. replacing the activate carbon filter, please initially press the
'filter cassette ust class M' (white fol e filter) into the slot for activate carbon filter
operation in the irection in icate by the arrow ( isplaye on the filter cassette).
The activate carbon mo ule cassette (black cassette) is then fitte .
14

10.7 Warranty
The warranty perio for our equipment is 12 months. If faults occur within the
warranty perio , contact your ental epot or get in touch irectly with our service
epartment.
Your equipment shoul only be operate in perfect con ition. If faults occur which
coul harm operators or thir parties, the unit shoul not be use until it has been
fixe .
This warranty oes not cover amage cause by improper use, external mechanical
causes, transport amage or interference with the unit by unauthorize persons.
11 Technical ata
SG-10 basic version Item no.: 140988
SG-10 activate carbon version Item no.: 140987 *
Voltage(*) 220–240 V / 50/60 Hz
Power consumption 0.75 A
Output 110 W
W x H x D 348 (without plug) x 423 x 270 mm
348 (without plug) x 672 x 270 mm*
Weight 8.2 kg epen s on version
Soun level < 70 B (A)
Suction capacity 600 m3/h (free-blowing)
270 m3/h (operating state)
Extractor nozzle Ø 75 mm exterior
(*)Other voltages on request
The noise level of the unit amounts to ≤ 70 B (A).
The emission value may be higher, epen ing on the number an the operating
con itions. Please take suitable protective measures (e.g. ear protectors).
Technical changes reserve .
15

12 Technical rawings
12.1 Construction SG-10 (incl. Activated Carbon Filter)
1 REF: 140410 Filter extension mo ule (without filter)
2 REF: 140424 Mo ule activate carbon filter (with filter)
3 REF: 140980 Suction unit SG-10 base
4 REF: 310035 I entification plate (serial number etc.)
5 REF: 610074 Spare micro fine ust filterbag (yellow) large, ust class M
16
fig. with accessory
item no. 140408
external spee regulator,
can be retrofitte
SG-10 #00168724 ff.

12.2 Construction Module Activated Carbon Filter (REF: 140424)
1 REF: 140426 Filter casing, cpl. SG-10
2 REF: 140427 Filter frame, cpl. SG-10
3 REF: 140435 Spare filter cassette, ust class F, cpl.
4 REF: 140436 Spare activate carbon filter, cpl.
17

13 isposing of the Unit
The unit has to be ispose by an authorize recycling operation. The selecte company
has to be informe of all possibly health-hazar ous resi ues in the unit.
13.1 Information on isposal for Countries within the EU
To conserve an protect the environment, prevent environmental pollution an
improve the recycling of raw materials, the European Commission a opte a
irective that requires the manufacturer to accept the return of electrical
an electronic units for proper isposal or recycling.
Within the European Union units with this symbol shoul not therefore be ispose of
in unsorte omestic waste.
For more information regar ing proper isposal please apply at your local authoritie.
18

14 EU eclaration of Conformity
in accor ance with 2014/35/EU (Low Voltage Directive) an 2014/30/EU (Electromagnetic
Compatibility Directive) an 2006/42/EC (Machinery Directive) an 2011/65/EU (RoHS
Directive)
Manufacturer: W A S S E R M A N N
Dental-Maschinen GmbH
Ru orffweg 15-17
21031 Hamburg
Germany
Pro uct escription: Suction Unit for
ental
applications
Mo el: SG-10 basic version
SG-10 activate carbon version
Item no. 140988
Item no. 140987
Applicable
stan ar s:
DIN EN 61010-1
DIN EN 61000-6-3
DIN EN 61000-6-1
DIN 45635-1
DIN EN 60335-1
Hiermit wir bestätigt, ass ie oben bezeichnete Maschine en genannten EU-Richtlinien
entspricht. Diese Erklärung wir ungültig, falls ie Maschine ohne unsere Zustimmung
verän ert wir .
This is to confirm that the above mentione machine complies with the escribe EU
gui elines. This eclaration becomes invali if the machine is mo ifie without our
approval.
Cette machine est conforme aux normes en vigueur ´Union européenne. Cet avis est
nul et non avenant si cette machine est mo ifiée sans notre accor .
Esta máquina, anteriormente menciona a, cumple con los limites requeri os por el
reglamento UE. Ahora bien, esta eclaración que ará invali a a en caso e realizar
mo ificaciones al aparato sin nuestra aprobación.
Hiermee wor t bevestig at bovengenoem e machine vol oet aan e voorgeschreven
EU normen. Deze verklaring verliest gel ighei als er zon er onze uit rukkelijke
toestemming wijzigen aan e machine wor en aangebracht.
Place, ate: Hamburg, 2020-09-03 Company stamp :
Signature: ________________________
Sven Wassermann
(Managing Director)
19

This manual suits for next models
2