INSTALLATION GUIDE
LVDT series LV, LVIT, LVIG, LVISM, LVPH
For further information please see the data sheet at www.waycon.biz/products/inductive-sensors-lvdt/
FIRST STEPS
WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and
our products. This manual will make you familiar with the installation and operation of our inductive
sensors LVDT. Please read this manual carefully before initial operation!
Unpacking and checking:
Carefully lift the device out of the box by grabbing the housing. After unpacking the device, check
it for any visible damage as a result of rough handling during the shipment. Check the delivery for
completeness.
If necessary consult the transportation company, or contact WayCon directly for further assistance.
GENERAL NOTES
• Mount the sensor before connecting the external electronics.
• The LV series can optionally be mounted with ange or foot clamps.
• Do not use the sensors near strong magnetic elds.
• Protect the electronics from moisture and humidity.
• Avoid lateral forces on the push rod.
• Do not press in the push rod beyond the specied total mechanical stroke.
• For a measuring range of 100 mm or more, the sensor housing must be additionally stabilised.
Otherwise the sensor may bend due to its own weight. In this case, we recommend using three
mounting brackets.
• For sensors without WayCon electronics, the minimum of the output signal is at the electrical centre
position. From there, half of the entire measuring range is in plus and half in minus (measuring range
start and measuring range end).
• The sensor is calibrated to the electronics supplied. The calibration protocol supplied loses its
validity as soon as the electronics are readjusted.
• Use the shortest possible cables between the sensor and the electronics.
ELECTRICAL CONNECTION LV
Sensor LV for external electronics LVA
Function Cable output Connector output Connection cable K4P...
Primary 1 BN Pin 1 BN
Primary 2 WH Pin 2 WH
Secondary 2 BU Pin 3 BU
Secondary 1 BK Pin 4 BK
Connector output M12,
male
12
34
Sensor LV for cable electronics LVC
Function Cable output Connector output Connection cable K5P...
Primary 1 BN Pin 1 BN
Primary 2 WH Pin 2 WH
Secondary 2 BU Pin 3 BU
Secondary 1 BK Pin 4 BK
Secondary 1, 2
Centre RD Pin 5 GY
Connector output M12,
male
12
34
5
ELECTRICAL CONNECTION LVIT
Function Cable output Connector output Connection cable K4P...
+24 VDC BN Pin 1 BN
Signal GN Pin 2 WH
GNDSupply GY Pin 3 BU
GNDSignal WH Pin 4 BK
Shield Shield Housing Shield
Connector output M12,
male
12
34
ELECTRICAL CONNECTION LVIG
Sensor with internal electronics
Function Cable output
+24 VDC BN
GNDSupply GY
Signal GN
GNDSignal WH
n.c. YE
Sensor for external electronics
Function Cable output
Primary 1 RD
Primary 2 BK
Secondary 2 OG
Secondary 1 YE
Secondary 1, 2
Centre WH
Shield Housing
core
secondary 1
secondary 2
secondary 1, 2 centre
primary 1
primary 2
ELECTRICAL CONNECTION LVISM
Function Cable output
Primary 1 BK
Primary 2 BU
Secondary 2 YE
Secondary 1 GN
Secondary 1, 2 Centre WH
Shield Housing
core
secondary 1
secondary 2
secondary 1, 2 centre
primary 1
primary 2
ELECTRICAL CONNECTION LVPH
Function Connector output
Primary 1 Pin 1
n. c. Pin 2
Secondary 2 Pin 3
Secondary 1 Pin 4
Primary 2 Pin 5
Connector output M12,
male
1
2
3
4
5
ELECTRICAL CONNECTION ELECTRONICS LVA
Function Terminal Function Terminal
Shield 1 Secondary 1 8
GNDSupply 2 Primary 1 9
+V 3 n. c. 10
n. c. 4 GNDSignal 11
Primary 2 5 Signal 12
Secondary 2 6 Shield 13
Shield 7
45678910
Ampl.
Gain
Oset
1
2
3
11
12
13
45 6 7 8 9 10
ELECTRICAL CONNECTION CABLE ELECTRONICS LVC
Function Connector output Connection cable K4P...
+V Pin 1 BN
Signal Pin 2 WH
GNDSupply Pin 3 BU
GNDSignal Pin 4 BK
Connector output M12,
male
12
34
WARNING NOTICES
• Do not open the device.
• Do not touch the push rod during operation.
• Protect the push rod from ice formation.
• In humid environments, install the sensor with the push rod outlet to the oor, otherwise water may
collect inside the sensor.
MAINTENANCE
The devices are maintenance-free. However, if the push rod becomes soiled due to adverse
environmental conditions, clean it with a cloth as required.
DECLARATION OF EU-CONFORMITY
WayCon Positionsmesstechnik GmbH
Mehlbeerenstraße 4
82024 Taufkirchen / Germany
This is to certify that the products
Classication Inductive Sensors LVDT
Series LVA, LVC, LVIT, LVIG
fulll the current request of the following EU-directives:
directive 2014/30/EU
2011/65/EU
The declaration of conformity loses its validity if the product is misused or modied without proper
authorisation.
Taufkirchen, 14.07.2021 Andreas Täger
CEO

This manual suits for next models

7

Other Waycon Accessories manuals

Waycon UFP Series User manual

Waycon

Waycon UFP Series User manual

Waycon MH60 Series User manual

Waycon

Waycon MH60 Series User manual

Waycon SX Series Operating and maintenance instructions

Waycon

Waycon SX Series Operating and maintenance instructions

Waycon MAB-A User manual

Waycon

Waycon MAB-A User manual

Waycon SX50 Series User manual

Waycon

Waycon SX50 Series User manual

Waycon UFA2 Series User manual

Waycon

Waycon UFA2 Series User manual

Waycon SX300 Series User manual

Waycon

Waycon SX300 Series User manual

Waycon LLD-RS232 User manual

Waycon

Waycon LLD-RS232 User manual

Waycon UFP Series User manual

Waycon

Waycon UFP Series User manual

Waycon LAS Series User manual

Waycon

Waycon LAS Series User manual

Waycon EZ 105 Series User manual

Waycon

Waycon EZ 105 Series User manual

Waycon LX Series User manual

Waycon

Waycon LX Series User manual

Waycon MAP Series User manual

Waycon

Waycon MAP Series User manual

Waycon LZW2 Series User manual

Waycon

Waycon LZW2 Series User manual

Waycon MSB Series User manual

Waycon

Waycon MSB Series User manual

Waycon SX300 Series User manual

Waycon

Waycon SX300 Series User manual

Waycon LAM Series User manual

Waycon

Waycon LAM Series User manual

Waycon UFA-CP Series User manual

Waycon

Waycon UFA-CP Series User manual

Popular Accessories manuals by other brands

NeuLog NUL-233 Guide

NeuLog

NeuLog NUL-233 Guide

Smeg Griddle Plate TBX6090 owner's manual

Smeg

Smeg Griddle Plate TBX6090 owner's manual

Aromasound Lilywood operating instructions

Aromasound

Aromasound Lilywood operating instructions

Hytronik HEC7028 instruction manual

Hytronik

Hytronik HEC7028 instruction manual

T&D RTR-500MBS-A Getting started guide

T&D

T&D RTR-500MBS-A Getting started guide

Hukseflux FHF04 user manual

Hukseflux

Hukseflux FHF04 user manual

PCB Piezotronics IMI SENSORS EX641B02 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS EX641B02 Installation and operating manual

QNect QN-WD01 installation guide

QNect

QNect QN-WD01 installation guide

Manitowoc K00044 installation instructions

Manitowoc

Manitowoc K00044 installation instructions

Viking DBCV3082 installation instructions

Viking

Viking DBCV3082 installation instructions

Orbis DICROMAT quick start guide

Orbis

Orbis DICROMAT quick start guide

Vega VEGAPULS 61 Quick setup guide

Vega

Vega VEGAPULS 61 Quick setup guide

Tellur PD102 Boost Pro user manual

Tellur

Tellur PD102 Boost Pro user manual

SunSetter EASYSHADE Replacement

SunSetter

SunSetter EASYSHADE Replacement

Bosch Rexroth HEDE 10-3 Series operating instructions

Bosch

Bosch Rexroth HEDE 10-3 Series operating instructions

Philips CRP350 brochure

Philips

Philips CRP350 brochure

Quark-Elec QK-AS08 manual

Quark-Elec

Quark-Elec QK-AS08 manual

Datasensor TL80 Series instruction manual

Datasensor

Datasensor TL80 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.