weewell WTE250 User manual

Infrared Ear Thermometer
www.weewell.com
WTE250
EN
TRKullanım Kılavuzu
User Manual
DIGITAL EAR THERMOMETER
DİJİTAL KULAK TERMOMETRE
ATEŞ ÖLÇEN CİHAZLAR

2 │ WTE250 USER MANUAL
Safety Precautions..............................................................................................3
Product Introduction............................................................................................4
Use Caution Items...............................................................................................5
Common Sense About Body Temperature...........................................................6
Product Layout....................................................................................................7
The Screen Display Marks Description................................................................8
Battery Installation Explanation...........................................................................8
Basic Parameter Instructions...............................................................................9
Introduction of Measurement Methods................................................................9
Product Cleaning Methods Instructions.............................................................11
Frequently Asked Questions and Solutions.......................................................12
Troubleshooting.................................................................................................13
Specifications of the Product............................................................................14
CONGRATULATIONS
Dear Stakeholder,
We congratulate you on hav�ng one of the Weewell products wh�ch are safely preferred all
over the World and becom�ng a part of the Weewell fam�ly. We are pleased to serve you w�th
our carefully des�gned products that appeal to bab�es such as v�deo mon�tor, aud�o mon�tor,
thermometer, nurs�ng and feed�ng group products.
Please read the user manual carefully before us�ng the product. Th�s gu�de has been
met�culously prepared to get the most out of your purchased product. You can call our call
center to get all k�nds of �nformat�on about the dev�ce and to contr�bute to our fam�ly w�th
your suggest�ons and op�n�ons. If you face w�th any problems or malfunct�ons, you can
contact Weewell author�zed serv�ce. For safety of yourself and other persons, read the
SAFETY PRECAUTIONS before us�ng the dev�ce.
Best Regards,
Weewell Turkey Team.
Contents
Safety Precaut�ons
• The warning signs and illustrations indicated in the manual are intended to
enable you to use the product safely and correctly and to prevent any harm
to you and others.
• Warning signs, illustrations and their meanings are as follows.

WTE250 USER MANUAL │ 3
Warning
• Please ask professional doctors to explain the measured value of body
temperature.
• The product is only used for human body temperature measurement.
• Please do not use this product for purposes other than body
temperature measurement.
• No mobile phones are allowed to use around this product.
• Please do not use equipment that generates electromagnetic fields
near the product.
• Please do not disassemble or repair this device by yourself including
changing device.
• Please do not bend or stretch the device hard.
• Please do not impact or drop this product.
No discard it at will is allowed.
IP Classification: IP22
Caution: please refer to attached file.
Legends
This mark means warning things (the things that you have to follow),
the left graph shows general compulsion.
It means the package of this unit can comply with the requirements of
green environmental protection.
This mark means prohibited things (not allowed things), it means general
prohibition in left picture.
It means general warning.
This mark means prohibited disassembly.
Type BF Applied part
Water resistance, moisture resistance.
It means that you need to read the manual carefully before use.
It means that the material of product or product itself is made of renewable
material so that we can cycle this product.

Product Introduction
Intended use: Infrared Ear Thermometer intended to measure human body
temperature by measuring ear canal.
Scope of application: It is suitable for displaying the body temperature of the
measured object by measuring the heat radiation in the ear canal.
Features:
1. Non-touching type infrared measurement of ear / surface temperature.
2. Multiple colors and backlight display: White, Green, Orange and Red.
3. 9 sets of memory values.
4. The switch of degree Fahrenheit °F and degree Celsius °C. (original setting
is degree Celsius °C)
5. Instant measurement within 1 second.
6. The design is convenient and economical without earmuff, which can save
subsequent use costs.
7. It has the function of sound on/off.
8. The machine idle time of 30 seconds, turn off power automatically.
9. WTE250 has already been calibrated during production. No need to
recalibrate.
4 │ WTE250 USER MANUAL
If you use or store this product beyond the range of specified temperature and
humidity, maybe it can not reach original performance specification.
Use environment: temperature: from +10°C~+40°C,
humidity: from 15%RH~93%RH
Storage environment: temperature: from -25°C~+55°C,
humidity: from 0%RH~93%RH
Warning Items
• This unit is only used for human body temperature measurement
without use of disease diagnosis; it cannot be used for emergency and
continuous measurement in surgery.
• The kids should get away from this product. If the kids are in this
range from zero to twelve years old, they need to use this unit to
measure under their parents help.
• The patients cannot diagnose the disease and get treatment by
themselves on the base of measurement result, they must follow the
instruction of doctors.
• Children under 12 years of age and those who cannot express their
thoughts are prohibited from using them.
• Please do not use this product for these people who suffer from otitis
external, tympanitis and other ear diseases.

Use Caution Items
• Warm tip:
The measurement results of this unit at any time only can be a reference, it
can not replace the medical diagnosis of professional doctor. If you have any
question about the personal temperature measurement result , please use
and diagnose under the right instructions of doctor.
Warning
1. It is very dangerous for patients to judge and treat on their own only by
measurement results, so please be sure to follow the doctor's instructions.
♦Self-judgment may lead to a worsening condition of patient.
2. Please do not touch with your hands or blow infrared sensor with your mouth.
♦When the infrared sensor is damaged or dirty, it may cause abnormal
measurement results.
3. If there is a temperature difference between the storage site and the
measurement site, please place it at room temperature (measurement site)
for about 30 minutes before next measurement.
♦May result in incorrect measurement results.
4. Please keep this product out of the reach of children.
♦When the child sticks to measure by himself, his ears may get hurt. If he
swallows the battery or the transparent cover accidentally, please contact
your doctor immediately.
5. When measuring body temperature, please do not get close to air conditioning.
♦Avoid affecting the measurement accuracy.
6. Before and after use every time, use a cotton swab dipped 75% alcohol to
wipe the probe surface. (If you see stains, fog or water on the infrared sensor
glass, please use a cotton swab dipped 75% alcohol for wiping the infrared
sensor glass gently.)
♦If you wipe it with toilet paper or facial tissue, it will scratch the infrared
sensor resulting in incorrect measurement result.
♦Avoid cross-infection of ear disease and affect the accuracy of the
measurement.
7. The product suffers mechanical damage.
♦There is a possibility that the measurement is not right.
8. The product touches water or immerses water accidentally, please fully dry
before use, especially the water on the surface of the sensor should be clean
by using cotton swab.
♦Our aim is to avoid causing safety accidents and affecting measurement
accuracy.
WTE250 USER MANUAL │ 5

Common Sense About Body Temperature
Caution:
1. Please do not use this product for these people who suffer from otitis
external, tympanitis and other ear diseases.
♦It is possible to worsen the affected area.
2. Please do not use this product after swimming or bath or wet ears.
♦It is possible to have low measured temperature value.
3. Do not place waste battery to danger zone.
♦The battery may break.
4. When measuring the ear temperature of human body, the product must be
operated in the ear temperature mode.
♦Result in inaccurate measurement result.
Suggestions
1. When you tell the doctor measured body temperature value, please tell the
doctor that you measured it with ear thermometer.
2. Please don't force to impact, fall, trample and shake this product.
3. Please do not disassemble, repair and modify this product.
4. Please do not allow liquid(such as alcohol, water- drop, hot water and so on)
to enter the product body because of this product without water resistance.
5. The product must be kept clean in a dry place.
6. If you find any problems, please contact the sales, you cannot repair the
product by yourself.
7. Please do not use it under the environment of electromagnetic interference.
8. Please deal with the waste and residue of this product at the end of the
service life according to local laws and regulations.
6 │ WTE250 USER MANUAL
The comparison of different measurement methods. The measured values are
different if we use different measurement methods. The WHO provides normal
human body temperature reference values, please see below table about the
specific temperature difference.
Measurement Methods Normal Body Temperature
Anal temperature 36.6°C~38°C
Oral temperature 35.5°C~37.5°C
Cochlear temperature 35.8°C~38°C
Axillary temperature 34.7°C~37.3°C
Oral temperature 35.5°C~37.5°C (WTE250 measured value)

Product Layout
WTE250 USER MANUAL │ 7
The changes in human body temperature
Human belongs to constant temperature animals, the body temperature is
basically constant, but it is not totally changeless, the human body temperature
is constantly changing in a day, the details as follows:
At night
Lowest Body temperature is lowest because of sleep and decreasing activity.
below 37°C)
In the morning
Higher From warm bed to the lower temperature room in the morning, the
whole body's muscles get contractions and produce heat.
At noon
Highest After lunch, human body reaches the highest temperature and the
body will adjust naturally.
Three or four o’clock in the afternoon
Lower Due to physical exertion, blood sugar decreased.
In the evening
Lowest Due to the sun down, room temperature goes down.
Measurement display
Display screen
Probe
Ear temperature cranium
MEM button
Power button
Battery cover

8 │ WTE250 USER MANUAL
Battery Installation Explanation
1. Press battery cover, the battery cover will bounce automatically.
2. Prepare two pieces of battery with the module of 1.5V AAA (number seven
battery) batteries (It is recommended to use alkaline batteries), please install
it into base of battery according to correct positive and negative poles.
Remove the battery
cover under pressure
Insufficient power caution:
when battery voltage is lack, LCD shows “ ” sign and battery
mark is always on, which means you should replace the battery.
The Screen Display Marks Description
Indication to Ear temperature
be measured measurement
Objects
measurement
Measurement
result display
Sound symbols Temperature
unit (°F or °C)
Power mark Memory
storage
Warm prompts
If you do not use this product for a long time, please take out battery to assure its longevity.
The liquid leakage of battery will harm the product; as well as pollute our environment.
• It is recommended to use alkaline batteries.
• The way to handle scrapped battery should match the requirements
of local country government and environmental protection organ.

WTE250 USER MANUAL │ 9
Please pull these
persons' ears back
above. (overone year old
kids and adults)
Introduction of Measurement Methods
Please pull back ears of
your kid who is within
one year old.
Ear temperature Ear temperature
Basic Parameter Instructions
1. Sound function: turn on/off
1) In the power-on state, press “mem” key to set the sound on or off.
2) Press “mem” button, LCD screen will show “ ” it means the sound works,
meanwhile we will hear a short beep sound.
3) Press “mem” button again, “ ” will change into, “ ” it means the sound will be off.
4. Back light status instructions
When measured temperature is < 34°C, it shows LO with red backlight.
When measured temperature value is 34°C~ 37.1°C, it means normal body
temperature and shows green backlight.
When measured temperature value is 37.2°C~ 38.1°C, it means that you have a bit of
fever and shows orange backlight.
When measured temperature value is 38.2°C~43.0°C, it means that you are in fever
stage and shows red backlight.
When measured temperature value is > 43.0°C, it shows red backlight and shows HI.
2. The switch of °F or °C
In off status , long press “mem” button for six seconds, it can switch between
Fahrenheit degree (°F) and Celsius degree (°C). Wait for 8 seconds to turn on the
product automatically or press “ ” to turn off the product directly.
3. Memory storage function
In off status, press “mem” button, the product can read and save 9 sets of
measurement values in order (as below picture shows). It will turn off automatically
without operating for 30 seconds or press “ ” button to turn off this product with your
hands.
Warm prompts: This function is for reference only.

1. Ear temperature measurement
10 │ WTE250 USER MANUAL
Note: If you did not hear the beep sound, which represents the temperature
measurement has not yet been completed. Please do not remove the
thermometer probe from ear canal at this time. (If you have closed the sound
indication, it will have no sound indication.)
1.1 After removing head cover, please press “ ” button to turn on this
product to enter the ear temperature measurement mode, LCD will display
measurement value last time. Then put the thermometer in your ear, the
ear temperature can be measured directly by pressing “ ” button.
1.2 After 1 second, you can see the measurement result.
When LCD is flashing,
we are waiting for
starting measurement.
Measurement result
2. Surface temperature measurement
2.1 Long press “ ” button to enter the object measurement mode for 6
seconds, and then aim the thermometer at the surface, the temperature of
the target surface can be measured directly by pressing “ ” button.
2.2 After 1 second, you can see the result of the measurement.
When LCD is flashing,
we are waiting for starting
measurement.
Measurement result

Product Cleaning Methods Instructions
Note: If you did not hear the beep sound, which represents the temperature
measurement has not yet been completed. Please do not remove thermometer
probe from target object at this time. (If you have closed the sound indication, it
will not have sound indication.)
WTE250 USER MANUAL │ 11
In order to ensure the precise measurements, it recommended to clean the
device after each use.
Please use cotton swab to dip 75% alcohol to wipe the thermometer probe and
remove the residue and dirt. We recommend you to clean the probe at least for
5 seconds. Then wipe the other components with a soft and dry cloth for 10
seconds at least. After cleaning, please ensure that there is no visible dirt or
residue on your thermometer, Wait 10 minutes before measuring
Warm prompt:
Why do you need to do a cleaning job after each measurement?
Because infrared temperature adopts highly sensitive technique to detect the
temperature of the target object, not only will any earwax and dust paste
affect the measurement accuracy, more likely to cause bacteria infection. So
we suggest that you should do cleaning job well as the picture shows after
you use every time.

Frequently Asked Questions and Solutions
12 │ WTE250 USER MANUAL
When the target object temperature is
higher than measurement range which
the ear temperature is more than
43.0°C, the LCD screen will
show "HI" indication.
1. (When the measurement probe is not
properly placed in the ear canal or if the
measurement distance is too far during
the measurement process, the
measurement result may be low.)
2. When measurement probe is dirty,
the measurement value may be low; we
should use a cotton swab to dip alcohol
to wash the measurement probe
properly.
When the target object temperature is
lower than measurement range which
the ear temperature is less than 34°C,
the LCD screen will show "Lo"
indication.
Screen
display
HI
Lo
This product has an upper limit of
operating temperature of 40°C. When
the ambient temperature exceeds this
temperature point, the LCD screen will
display an error message “Er.H".
When you operate this product,
the environment temperature cannot be
greater than 40°C.
Er.H
This product has a lower limit of
operating temperature of 10°C. When
the ambient temperature exceeds this
temperature point, the LCD screen will
display an error message “Er.L”.
When you operate this product, the
environment temperature can not be
lower than 10°C.
Er.L
When the environment temperature
changes rapidly about 5 degrees, it will
show“ Err ” during measurement in
object temperature mode, then
shutdown automatically.
When the operation is wrong, if the sound is turned on, then the sound will read the
value and remind at this moment.(A short beep will be heard.)
When it shows “Err”, please place this
product and keep steady in current
environment for 30 minutes before next
measurement.
Err
Reasons Solutions

WTE250 USER MANUAL │ 13
Troubleshooting
Reasons
PhenomenonsSolutions
The battery is exhausted. Replace the new battery.
The battery polarity is wrong.
When the power
is turned on, the
screen can not be
displayed.
The battery polarity is the
same as the battery case.
The measurement
temperature is
low.
The measurement position
is not correct.
There are dirt stuff in the
sensor or ear canal.
Measure the temperature
correctly according to the
instructions.
Please clear the dirt before
the measurement.
The measurement
interval is too small.
The interval for each
measurement should
be above 10 seconds.
Big temperature
fluctuations with
continuous
measurement.

14 │ WTE250 USER MANUAL
Product name: Infrared Ear Thermometer
Model number: WTE250
Lot No: 1-20193107
Product appearance dimensions: 32×158×55mm
Product weight: about 65g (except battery)
Measuring range: 34.0°C-43.0°C.(93.2°F-109.4°F)
Surface temperature: 0°C- 93.2°C (32°F-199.7°F)
Resolution ratio: 0.1°C/°F
Measurement location: laboratory
Accuracy: (35.0°C~42.0°C)±0.2°C, (95.0°F~107.9°F)±0.4°F, other
temperature±0.3°C.
Operation temperature: 10.0°C~40.0°C(50.0°F~104.0°F), relative maximum
humidity 15%RH~93%RH
Atmospheric pressure: 70kPa~106kPa
Transportation/storage temperature: -25°C~55°C(-13°F~ 131°C), relative
maximum humidity 0%RH~93%RH
Atmospheric pressure: 50kPa~106kPa
Display screen: LCD display screen, 4 bit numbers and special icons.
Sound: when you turn on the product and ready to measure, a short beep will
be heard.
The measurement is finished with a long beep.
System error or fault: short beeps for three times.
Fever alert: short beeps for ten times come with urgency.
Memory: in memory mode, it can record nine temperature numbers.
Automatically shut down: if no operation for 30 seconds, it will shutdown
automatically.
Battery: two pieces of 1.5V AAA (number seven) batteries (alkaline batteries
are recommended to use).
Period of use: three years
Packing parts list
1. Main body
2. Product manual
Specifications of the Product

WTE250 USER MANUAL │ 15
The Model WTE250 Infrared Thermometer is intended for use in the electromagnetic
environment specified below. The customer or the user of the Model WTE250 Infrared
Thermometer should assure that it is used in such an environment.
Appendix 1 Guidance and Manufacturer Declaration Tables
Emissions Compliance Electromagnetic
environment - guidance
Guidance and Manufacturer’s Declaration - Electromagnetic Emissions
RF emissions
CISPR 11 Group 1
RF emissions
CISPR 11 Group B
Harmonic emissions
IEC 61000-3-2 N.A.
Voltage fluctuations
/ flicker emissions
IEC 61000-3-3 N.A.
The Model WTE250 Infrared Thermometer
uses RF energy only for its internal function.
Therefore, its RF emissions are very low and
are not likely to cause any interference in
nearby electronic equipment.
The Model WTE250 Infrared Thermometer is
used in home and it’s powered by DC 3V
The Model WTE250 Infrared Thermometer is intended for use in the electromagnetic
environment specified below. The customer or the user of the Model WTE250 Infrared
Thermometer should assure that it is used in such an environment.
NOTE UTis the a.c. mains voltage prior to application of the test level
Immunity
test IEC 60601
test level Compliance
level Electromagnetic
environment - guidance
Guidance and Manufacturer’s Declaration - Electromagnetic Immunity
Electrostatic
discharge
(ESD)IEC
61000-4-2
±8 kV contact
±2 kV, ±4 kV,
±8 kV, ±15KV
air
±8 kV contact
±2 kV, ±4 kV,
±8 kV, ±15 KV
air
Floors should be wood,
concrete or ceramic tile. If floors
are covered with synthetic
material, the relative humidity
should be at least 30 %.
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
30 A/m,
50/60Hz
30 A/m,
50/60Hz
Power frequency magnetic fields
should be at levels characteristic
of a typical location in a typical
commercial or hospital
environment.

16 │ WTE250 USER MANUAL
The Model WTE250 Infrared Thermometer is intended for use in the electromagnetic
environment specified below. The customer or the user of the Model WTE250 Infrared
Thermometer should assure that it is used in such an environment.
Immunity
test IEC 60601
test level Compliance
level Electromagnetic
environment - guidance
Guidance and Manufacturer ’s Declaration - Electromagnetic Immunity
Conducted
RF IEC
61000-4-6
Radiated
RF IEC
61000-4-3
3 Vrms150
kHz to 80
MHz 6 Vrms
150 kHz to
80 MHz
outside ISM
bandsa
10 V/m
80 MHZ to
2.7 GHz
N/A
10 V/m
Portable and mobile RF
communications equipment
should be used no closer to any
part of the Model WTE250
Infrared Thermometer, including
cables, than the recommended
separation distance calculated
from the equation applicable to
the frequency of the transmitter.
where P is the maximum output
power rating of the transmitter in
watts (W) according to the
transmitter manufacturer and d is
the recommended separation
distance in metres(m).
Field strengths from fixed RF
transmitters, as determined by an
electromagnetic site survey, a
should be less than the
compliance level in each
frequency range b
Interference may occur in the
vicinity of equipment marked with
the following symbol:
Recommended separation
distance

WTE250 USER MANUAL │ 17
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and people.
a The ISM (industrial, scientific and medical) bands between 0,15 MHz and 80 MHz are
6,765 MHz to 6,795 MHz; 13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283 MHz; and
40,66 MHz to 40,70 MHz. The amateur radio bands between 0,15 MHz and 80 MHz are
1,8 MHz to 2,0 MHz, 3,5 MHz to 4,0 MHz, 5,3 MHz to 5,4 MHz, 7 MHz to 7,3 MHz, 10,1
MHz to 10,15 MHz, 14 MHz to 14,2 MHz, 18,07 MHz to 18,17 MHZ, 21,0 MHz to 21,4
MHz, 24,89 MHz to 24,99 MHz, 28,0 MHz to 29,7 MHz and
50,0 MHz to 54,0 MHz.
c Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV
broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the Model WTE250
Infrared Thermometer is used exceeds the applicable RF compliance level above, the
Model WTE250 Infrared Thermometer should be observed to verify normal operation. If
abnormal performance is observed, additional measures may be necessary, such as
re-orienting or relocating the Model WTE Infrared Thermometer.
b The compliance levels in the ISM frequency bands between 150 kHz and 80 MHz and in
the frequency range 80 MHz to 2,7 GHz are intended to decrease the likelihood that
mobile/portable communications equipment could cause interference if it is inadvertently
brought into patient areas. For this reason, an additional factor of 10/3 has been
incorporated into the formulae used in calculating the recommended separation distance
for transmitters in these frequency ranges.
d Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

18 │ WTE250 USER MANUAL
The Model WTE250 Infrared Thermometer is intended for use in an electromagnetic
environment in which radiated RF disturbances are controlled. The customer or the user of
the Model WTE250 Infrared Thermometer can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF communications
equipment (transmitters) and the Model WTE250 Infrared Thermometer as recommended
below, according to the maximum output power of the communications equipment.
For transmitters rated at a maximum output power not listed above the recommended
separation distance d in metres (m) can be estimated using the equation applicable to the
frequency of the transmitter, where P is the maximum output power rating of the transmitter
in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range
applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and people.
Separation distance according to frequency of transmitter mRated maximum
output
of transmitter
W
Recommended Separation Distances Between Portable and mobile RF
Communications Equipment and the Model WTE250 Infrared Thermometer
100
10
1
0.1
0.01
12
3.8
1.2
0.38
0.12
12
3.8
1.2
0.38
0.12
23
7.3
2.3
0.73
0.23
150kHzto80 MHz 80MHzto800MHz
800 MHzto2.7GHz

Güvenlik Uyarıları
• Kılavuzda belirtilen uyarı işaretleri ve resimler, ürünü güvenli ve doğru
şekilde kullanmanıza ve size ve başkalarına olabilecek herhangi bir zararı
önlemeye yöneliktir.
• Uyarı işaretlerinin anlamlarını Göstergeler tablosundan öğrenebilirsiniz.
WTE250 KULLANIM KILAVUZU │ 19
TEBRİKLER
Değerl� paydaşımız,
Weewell a�les�n�n b�r parçası olduğunuz ve dünyanın her yer�nde güvenle terc�h ed�len
Weewell ürünler�nden b�r�ne sah�p olduğunuz �ç�n s�z� kutlarız. Bebek �zleme c�hazı, bebek
tels�z�, ateş ölçer, emz�rme ve beslenme grubu ürünler� g�b� bebeklere h�tap eden özenle test
ed�lm�ş ürünler�m�zle s�zlere h�zmet vermekten mutluluk duyuyoruz.
Ürünü kullanmadan önce lütfen kullanma kılavuzunu d�kkatl�ce okuyunuz. Bu kılavuz, satın
almış olduğunuz üründen en �y� ver�m� almanız �ç�n t�t�zl�kle hazırlanmıştır. C�haz �le �lg�l� her
türlü b�lg� almak, öner� ve görüşler�n�z �le a�lem�ze katkı sağlamak �ç�n çağrı merkez�m�z�
arayab�l�r; herhang� b�r problem ya da arızayla karşılaşmanız durumunda Weewell Yetk�l�
Serv�s�’ne başvurab�l�rs�n�z. Kend�n�z�n ve d�ğer k�ş�ler�n güvenl�ğ� �ç�n c�hazı kullanmadan
önce GÜVENLİK UYARILARI bölümünü okuyunuz.
Saygılarımızla,
Weewell Türk�ye Ek�b�
Güvenlik Uyarıları..............................................................................................19
Ürün Genel Bilgileri............................................................................................21
Güvenlik Maddelerinin Kullanımı.......................................................................22
Vücut Sıcaklığı Hakkındaki Yaygın Fikir.............................................................23
Ürün Düzeni......................................................................................................24
Ekran Görüntüsü Açıklamaları...........................................................................25
Pil Yerleştirme Talimatları...................................................................................25
Temel Parametre Talimatları..............................................................................26
Ölçüm Yöntemlerine Giriş..................................................................................26
Ürün Temizleme Yöntemleri Talimatları.............................................................28
Sıkça Sorulan Sorular ve Çözümleri..................................................................29
Arıza Giderme...................................................................................................30
Ürünün Özellikleri..............................................................................................31
İçindekiler

20 │ WTE250 KULLANIM KILAVUZU
Uyarı
İsteğe göre atılmasına izin verilmez.
• Lütfen doktorlardan vücut sıcaklığının ölçülen değerini açıklamalarını
isteyin.
• Ürün sadece insan vücudu sıcaklığını ölçmek için kullanılır.
• Lütfen bu ürünü vücut sıcaklığı ölçümü dışındaki amaçlarla kullanmayın.
• Bu ürünün çevresinde cep telefonu kullanılmasına izin verilmez.
• Lütfen ürünün yakınında elektromanyetik alan üreten cihazları
kullanmayın.
IP Sınıflandırma: IP22
• Cihazı değiştirmemekle birlikte, lütfen bu cihazı kendiniz sökmeyin
veya tamir etmeyin.
• Lütfen cihazı bükmeyin veya germeyin.
• Lütfen bu ürüne darbeye maruz bırakmayın veya düşürmeyin.
Dikkat: lütfen ekli dosyaya bakınız.
Göstergeler
Uyarıları (takip etmeniz gerekenleri) ve genel zorunluluğu belirtir.
Ürün ambalajının yeşil çevre koruma gerekliliklerine uygun olabileceği
anlamına gelir.
Yasaklanan şeyleri (izin verilmeyen şeyler) ifade eder.
Genel uyarı anlamına gelir.
Yasaklanmış sökme işlemini ifade eder.
Tip BF uygulama parçası
Suya ve neme karşı dayanıklı anlamına gelir.
Kullanımdan önce kılavuzu dikkatlice okumanız gerektiği anlamına gelir.
Ürünün kendisinin ya da malzemesinin yenilenebilir malzemeden
yapıldığı anlamına gelir, böylece ürünün geri dönüşümünü yapılabilir.
Table of contents
Languages:
Other weewell Thermometer manuals