FITTING INSTRUCTIONS
ASTRON PASSAGE SET
© WINDSOR ARCHITECTURAL HARDWARE
1. Measure the door thickness and mark
the centre at the desired height for the
latch.
2. Drill a 25mm (1") diameter hole
through the door edge to a depth of
at least 90mm. Ensure this hole is
square to the door.
3. Mark the face of the door each side
for drilling a 48mm diameter hole.
The centre of the spindle hole will
need to be 60mm from the door edge
(backset). We recommend using a
48mm hole saw. For clean cut-outs,
drill from both sides, meeting in the
middle of the door.
4. Insert the latch, scribe
around the faceplate,
remove, then chisel out
recess to enable the latch
faceplate to sit flush with
the door edge.
5. Remove any loose saw
dust, insert the latch and
secure it with the wood
screws provided.
6. Insert handle ‘A’ in the 48mm
hole with the spindle and
rapidFIT® attached and
press against the door.
Ensure the grooved side of
the spindle is aligned with
the grubscrews on the
handles.
7. Insert ‘handle B’ over the
spindle. Ensure the handles
are straight before securing
the through fixing screws.
8. Screw the rose cover onto
the handle and tighten the
grubscrews on the side of
the levers onto the spindle
for each side of the door.
For the square rose (Astron
Elite) press on the rose
cover and tighten the
grubscrew on the side
of the rose.
Note: The grubscrews may
need a re-tighten after a
bedding-in period.
We recommend medium
strength thread-lock to be
used, Windsor code:1276
48mm
backset
25mm
Version 2
handle ‘B’
handle ‘A’
Product codes:
7059 7107 7422 7432 7036 7033
60mm
Backset
length
Lever
rapidFIT®
Spindle
Latch
Grubscrew
Screw-on rose
Striker with
dustbox
9. Close the door against the
frame and mark the latch
position for fitting of the
striker.
10. Router or chisel so the
striker fits flush, allowing
for the plastic dustbox
behind the striker.
11. Secure the striker with the
wood screws provided. Test
the door and if necessary,
adjust the striker anti-rattle
tab to take up any rattle.
To view an easy to follow how-to video for installing this product visit windsorhardware.co.nz/installation.
0800 607 028
sales@windsorhardware.co.nz
windsorhardware.co.nz
FITTING INSTRUCTIONS
© WINDSOR ARCHITECTURAL HARDWARE
Version 4
ASTRON PASSAGE SET - rapidFIT REMOVED Product codes:
7059 7107 7422 7432 7036 7033
1. Remove the rose cover
from the handle.
For the round roses
unscrew rose cover.
For the square roses
(Elite) unscrew the
grubscrew on the side
of the rose and pop off
the rose cover.
2. Remove the screws
with the red screw
head.
3. Remove the rapidFIT
boss from the handle.
4. Measure the door thickness and mark the
centre of the door edge at the desired
height for the latch.
5. Drill a 25mm (1") diameter hole through
the door edge to a depth of at least 90mm.
Ensure this hole is square to the door.
6. Mark the face of the door each side for
drilling a 25mm diameter spindle hole. The
centre of the spindle hole will need to be
60mm from the door edge (backset). Mark
two screw holes at 21mm above and
below the centre of the spindle hole. Drill
the screw holes to 6mm diameter. For
clean cut-outs, drill from both sides,
meeting in the middle of the door.
7. Insert the latch, scribe around
the faceplate, remove, then
chisel out recess to enable the
latch faceplate to sit flush with
the door edge.
8. Remove any loose saw dust,
insert the latch and secure it
with the wood screws provided.
9. Unscrew or pull off the rose covers
and i
nsert the spindle into the latch
so an even amount protudes on
each side of the door. Ensure the
grooved side of the spindle is
aligned with the grubscrews on the
handles.
To view an easy to follow how-to video for installing this product visit windsorhardware.co.nz/installation.
11. Slide the handle on the opposite
side of the door over the spindle
and press against the door.
Insert the long bolts through the
face of the rose and tighten
them into the blind nuts.
12. Screw the rose covers onto the
handles and tighten the
grubscrews on the side of the
levers onto the spindle for each
side of the door. For the square
rose (Astron) press on the rose
covers and tighten the
grubscrews on the sides onto
the roses.
10. Insert the blind nuts through the face
of the rose at two vertical positions.
Slide the handle over the spindle and
press against the door.
13. Close the door against the
frame and mark the latch
position for fitting of the
striker.
14. Router or chisel so the
striker fits flush, allowing
for the plastic dustbox
behind the striker.
15. Secure the striker with the
wood screws provided.
16. Adjust the anti-rattle tab on
the inside of the striker if
necessary to ensure a firm
close of the door.
Note: The grubscrews may need a
re-tighten after a bedding-in period.
We recommend medium strength
thread-lock to be used, Windsor
code:1276

This manual suits for next models

5

Other Windsor Door Lock manuals

Windsor 1501 User manual

Windsor

Windsor 1501 User manual

Windsor 9201D User manual

Windsor

Windsor 9201D User manual

Windsor 5327 User manual

Windsor

Windsor 5327 User manual

Windsor 1335 User manual

Windsor

Windsor 1335 User manual

Popular Door Lock manuals by other brands

BURG-WACHTER TSE HOME 4001 Installation and user manual

BURG-WACHTER

BURG-WACHTER TSE HOME 4001 Installation and user manual

Griffwerk smart2lock installation instructions

Griffwerk

Griffwerk smart2lock installation instructions

GEM GL600-S Specification sheet

GEM

GEM GL600-S Specification sheet

Kwikset Smartcode 914 Installation and user guide

Kwikset

Kwikset Smartcode 914 Installation and user guide

Weiser 26924 instructions

Weiser

Weiser 26924 instructions

Signature Hardware BULLOCK 915876-DU Installation

Signature Hardware

Signature Hardware BULLOCK 915876-DU Installation

Digitus Biometrics dbBioLock installation manual

Digitus Biometrics

Digitus Biometrics dbBioLock installation manual

Schlage BE469 user guide

Schlage

Schlage BE469 user guide

Yale YDR3110 user guide

Yale

Yale YDR3110 user guide

Maco A-TS Assembly instructions

Maco

Maco A-TS Assembly instructions

ShineACS SL-P8812 user manual

ShineACS

ShineACS SL-P8812 user manual

Assa Abloy R10 installation guide

Assa Abloy

Assa Abloy R10 installation guide

Gate House G2X2D01 installation guide

Gate House

Gate House G2X2D01 installation guide

PEAKnx Controlpro and Gira DCS Getting started

PEAKnx

PEAKnx Controlpro and Gira DCS Getting started

Hafele Dialock DT 210 R2 installation instructions

Hafele

Hafele Dialock DT 210 R2 installation instructions

WALA WU1R E instructions

WALA

WALA WU1R E instructions

Intelligent Biometric Controls 1TouchXLS Operator's manual

Intelligent Biometric Controls

Intelligent Biometric Controls 1TouchXLS Operator's manual

ikonic Privacy Lever Set manual

ikonic

ikonic Privacy Lever Set manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.