Wisy Optima User manual

● Operating
instructions for
the OPTIMA
rainwater unit
● Please read through
these instructions
carefully before
you attempt to
install and use the
rainwater unit!
● 3- or 4-stage
self-priming
centrifugal pump
● Operates fully
automatically to
supply household
appliances on
demand
● Automatic mains
water top-up
with integral
9-litre top-up tank
● Energy efficient
technology, standby
usage less than 0.2 W
InstallatIon InstructIons
Rainwater Unit
OPTIMA
WISY
Rainwater Harvesting
Original
ΩΩ
OPTIMA
EN
2
30 %
5 %
Harvesting rainwater
reduces mains water
consumption by:
50 %!
WC:
30 %
Laundry:
13 %
Garden irrigation:
5 %
Cleaning:
2 %
13 %
2 %
1 Vortex fine filter (WFF)
2 Inflow calming
3 Floating
suction filter
4 Multisiphon
5 Rainwater storage tank
6 Sigma rainwater unit
7 Filter collector (FS)
8 Rainwater barrel 500 l
Stage 2
WISY inflow calming
prevents resuspension of
sediment and distributes
the fresh, oxygen-rich
water in the storage tank
Stage 3
Water is extracted with
the WISY floating suction
filter suspended
at the optimum height
Stage 4
Overflow with skim effect,
odour seal, small animal
guard and backflow pre-
vention with WISY multi-
siphon
The WISY 4-stage
rainwater cleansing
system
6
7
8
1
4
2
3
5
The WISY 4-stage rainwater cleansing principle in the single-family home
Stage 1
Filtering with WISY
vortex fine filter with
separation of dirt particles
and oxygen enrichment
3
OPTIMA Rainwater Unit
Please read through these installation instructions carefully
before you attempt to install and use the rainwater unit!
These installation instructions include the following information relating to:
● Applications
● Handling and storage instructions, scope of delivery
● Components diagram
● Safety instructions
● Preparations for installation, assembly
● Commissioning
● Design and operating principle
● Maintenance, repairs
● Materials
● Troubleshooting guide
● Technical data
● Environmental guidance
● Declaration of conformity
● Guarantee conditions, device number
Applications
The OPTIMA rainwater unit by WISY is the control centre of the rainwater har-
vesting system.
OPTIMA works without suction pipes. It pumps the rainwater out of the storage
tank and feeds it under pressure into the rainwater supply circuit. At the same
time, the OPTIMA checks the fill level of the storage tank and tops up the system
with mains water when required.
The OPTIMA can supply toilet flush, washing mashine and garden Irrigation with
prefiltered rainwater for detached/semi-detached houses up to three storeys. Op-
tima needs a minimum flow of 5 Liter per minute for operation. All taps and pipes
must be sealed and tight closing. For more than 20 starts per hour an additional
surge tank is necessary. Sand or dirt must not be in the water as they can destroy
the OPTIMA unit.
Delivery / shipment of the unit
The standard version of the Optima unit is generally shipped as a parcel contai-
ning two cardboard packages. The cardboard packages must not be dropped,
crushed or handled with force. As soon as the packages are received, they must
be checked for any signs of damage.
The cardboard packages or their contents must be stored in a safe, dry and frost-
free location.
Scope of delivery
● Wall unit with normal-suction, multi-stage centrifugal pump with automatic
switch and pressure indicator Zeta 02: Max. pressure in rainwater operation:
4.2 bar or 5.3 bar . In mains water operation 3.3 bar or 4,4 bar
●Automatic mains water top-up (to DIN EN 1717) of integrated top-up tank
(9 litres) when rainwater runs out, with float valve, dirt filter and safety
emergency overflow (DN 70).
●Cover, grey color, to protect the rainwater unit.
●Wall mounting kit.
●Separate submersible pump with 20 m connecting cable. Installation inside
the storage tankwith fix mounted vertical float switch for dry run protection and
fix mounted floating fine suction filter..
● Screw and rope to lift the submersible pump
Contents
Wall unit
Read the operating instructions
carefully before commencing
assembly and installation work
and store them in a safe place for
later reference. Follow the safety
instructions!
Storage tank equipment
!
Failure to heed the infor-
mation indicated by this
symbol could result in
serious or fatal injury.
Failure to heed the
information indicated by
this symbol could result
in death by electric shock.
Failure to heed the information indi-
cated by this symbol could result in
damage to the equipment, or damage
caused by the equipment.
!
!

4
1 Mains water connection (top-up)
2 Pumped rising main (submersible pump)
3 Pressurized outlet
4 Mains plug for complete system
5 Electrical connection (blue socket)
for submersible pump
6 Emergency overflow drain connection (DN 70)
7 Operating pressure indicator
(pressure gauge)
8 Normal-suction centrifugal pump
9 Schaltautomat ZETA 02
10 Base frame
11 Connecting hose to pressurized outlet
12 Submersible pump with float switch
13 Floating fine suction filter (FFSF)
14 Screw plug for venting/filling
Accessories not included in the
scope of supply:
15 Isolating valves for mains water pipe
and rainwater circuit
16 Multisiphon (odour seal and
backflow prevention)
17 Water meter/mains water top-up
18 Water meter/rainwater
19 Flexible connecting hoses
Illustration does not show connecting kit for
extending the electric cable
Guide to components
1
7
9
15
18
19
4
5
2
5
2 19
311148
10
6
17
16
1213
5
Safety instructions
Read the operating instructions carefully before commencing assembly and in-
stallation work and store them in a safe place for later reference.
Do not lift or pull the float switch by its electric cable.
Never climb inside the storage tank when the OPTIMA rainwater unit is connec-
ted to the power supply. Always unplug the OPTIMA rainwater unit to discon-
nect it from the power supply before carrying out any inspection, maintenance
or repair work to the OPTIMA rainwater unit or inside the storage tank.
Never leave the rainwater storage tank unsupervised when it is open! No one ex-
cept specially trained personnel is allowed to climb inside the rainwater storage
tank. When working inside the tank, personnel must be supervised at all times
and must take appropriate safety precautions (e.g. wear a recovery harness).
If the residual current device or the fuse trips, the trip cause must be identified
and rectified by the manufacturer / by a contractor appointed by the manufac-
turer.
If the power cable to the OPTIMA unit or the float switch is found to be dama-
ged, it must be replaced by the manufacturer / by a contractor appointed by the
manufacturer.
Installation work which involves particular hazards (e.g. risk to mains water sup-
ply or the electrical installation) must always be carried out by a properly trai-
ned, approved plumber or electrician who is at least qualified in the following
technical areas:
● Selection of appropriate tools and suitable electrical and installation
materials
● IP degrees of protection
● Correct methods of installing electrical and other materials
● TN-C system, TN-S system and appropriate additional measures
where necessary.
● Drinking water protection in accordance with DIN EN 1717, DIN 1989
Failure to install the equipment properly can endanger your own life and the
lives of people who use the equipment.
The system must be connected to a 230 V, single-phase AC (50 Hz) supply.
The SIGMA unit must be operated with clean water (rainwater or mains water)
which does not contain aggressive, abrasive or solid substances.
Failure to adhere to these instructions and/or unauthorized interference with the
OPTIMA shall exempt WISY AG from any liability for any personal injuries, pro-
perty damage and/or damage to individual components of the OPTIMA system.
The OPTIMA product is generally shipped in a cardboard box. The cardboard
box must not be dropped, crushed or handled with force, and must be inspec-
ted for damage as soon as it is received.
The cardboard box or its unpacked contents must be stored in a safe, dry, and
frost-free location and protected against the ingress of dirt or contaminants.
Preparations for installation
The OPTIMA rainwater unit should be installed by a specialist installation compa-
ny. This is a basic requirement for maintaining the validity of the manufacturer‘s
guarantee.
Please note: The OPTIMA must be installed above the backflow level. Special
protective measures must be implemented if the unit is installed and operated
below the backflow level!
If the maximum fill level of the storage tank is higher than the bottom edge of
the installed OPTIMA wall unit, the pumped rising main connection at the wall
unit must be equipped with a solenoid valve (normally closed) and possibly an
isolating valve (for service work). The solenoid valve is opened only when the
loading pump is started.
If a reliable, permanent connection cannot be made between the emer-
gency overflow of the mains water top-up tank and a domestic drainage
connection, a floor Drain must be provided.
The water column between the pump integrated in the wall unit and the highest
operating point (valve at appliance) must not exceed 15 m!
Piping or hoses must be cleaned or flushed through before use to remove any
deposits of dirt/dust caused by building work!
Important: The protective plugs fitted over the connectors on the wall unit
and the submersible pump must be removed before hoses or pipes are
connected to the units!
Note regarding the backflow
level and essential installation
conditions
!
Additional instructions
Delivery / shipment of the unit
Flush pipes before connecting
to the wall unit
6
Electrical connection
Installing the submersible pump
!
Assembly
● Attach the wall mounting kit horizontally according to the dimensions given.
The wall-mounting bracket can be used as a drilling template; the distance
between the two holes is 280 mm. The rainwater unit can then simply be
inserted in the groove of the bracket.
● We recommend the use of our hose connection kit (Item No. RW 7800) to
connect the wall unit. Furthermore, all connections on the wall unit must be
flat-sealing.
●Connect the incoming mains water pipe to the mains inlet connector on the
OPTIMA unit. Use a ¾” connecting hose with stainless steel sheath (acces-
sory) to connect the mains water pipe to the mains inlet connector on the
OPTIMA wall unit. The top-up flow rate is approximately 95 l/min with a mains
pressure rating of 3 bar (= 300 kPa).
●Important: If the mains pressure rating at the installation site is less than 3 bar
(= 300 kPa), it may be necessary to increase the cross section of the mains
pipe (e.g. to 1”). If the mains pressure rating is higher than 5 bar (= 500 kPa),
it may be necessary to install a pressure reducing valve in order to limit the
flow pressure to between 4 and 5 bar (= 400 to 500 kPa). Please consult
your installation specialist or contact WISY AG directly. It is also advisable to
install an isolating ball valve (with dirt trap) between the mains water supply
and the connecting hose to the wall unit
●Connect the emergency overflow (DN 70) of the mains water top-up tank us-
ing an odour seal (siphon) to a domestic drainage connection or feed it back
to the storage tank.
●If the unit is installed below the backflow level, an additional backflow preven-
tion device (multisiphon) must be provided. l Connect the OPTIMA unit to the
household rainwater circuit using a flexible connecting hose and an isolating
ball valve with drain valve (accessory). In order to record water consump-
tion, it is advisable to fit a water meter in the pressurized rainwater outlet
hose and the mains water top-up hose, as shown in the illustration.
●In order to record water consumption, it is advisable to fit a water meter in
the pressurized rainwater outlet hose and the mains water top-up hose, as
shown in the illustration.
●Place the pump with float switch and fine suction filter in a vertical position on
the base of the storage tank!
●Important: Never lift or pull the submersible pump by the cable! Please use
the plastic carrying strap (supplied with the unit)! Use a pressure hose or a
rigid PE pipe to connect the submersible pump to a flexible connecting hose
(accessory) of the rainwater unit (diameter of pressure hose 1”). Do not install
any flow resistances (e.g. water meters, backflush filters) in the pumped ris-
ing main between the loading pump and the wall unit.
● The mains electrical connection of the OPTIMA unit (alternating current,
single-phase, 50 Hz, 230 V) must be protected by an earth-leakage circuit-
breaker (0.03 A) and a 16 A fuse. It is essential that all electrical installation
work is carried out in compliance with the relevant safety regulations!
●A blue socket is provided on the underside of the wall unit to connect the
electrical supply to the submersible pump (loading pump). No other item of
equipment may be connected to this socket! The loading pump must not be
connected to the electrical supply at the wall unit until the pump has been
vented.
Assembling the wall-
mounting bracket
Installing the wall unit
Top
rear panel
of casing
Note height of
top edge of unit
Insert
!
Ratio between Distance from loading pump
to wall unit and the maximum Delivery height.
When greater Heights or longer pipes are
needed we recommend to use the Rainwater
unit OptimaPlus or Maxima
88
Height in meters
Pipe length in meters
0
1
2
3
4
5
6
7
10 12 14 16 18 20 22 24 26
7

●If the mains connection cable of the wall unit becomes damaged, a replace-
ment cable must be obtained from the manufacturer, from a service partner
or from an authorized specialist supplier.
Important: The pumps must not be put into
operation, or even tested, unless the system
is filled with water.
Make sure that the storage tank is filled with a
sufficient quantity of water. The submersible
pump should be completely immersed in
water and the float switch must be floating.
Basic operating principle
with two pressure pumps
Top-up with mains water
Commissioning
before starting the operation the water level in the tank must be at least 0,5 m.
The submersible pump must be completely immersed in water
1. Flush all pipes to make sure all dirt from construction is removed
2. Venting of the pump integrated in the wall unit by the loading pump:
Undo the venting screw on the pump in the wall unit, connect only the
loading pump to a nearby electrical supply and wait until water starts to
flow from the opening of the venting screw, then close the screw. pull out
the electrical plug of the loading pump and connect it to the wall unit (blue
socket on underside of the wall unit).
3. Flush the mains water pipe and connect it to the wall unit. Connection
is on top right side. Observe the filling of the 9 Liter container. The float
switch must not touch the walls and must close in due time. Water must not
overflow into the emergency overflow.
4. Open the valves at the appliances.
5. Connect the OPTIMA to the electricity supply.
6. Close the Cover of the water container
7. As soon as system all air is removed from pipes, close the valves at the
appliances! The OPTIMA unit is ready to operate.
Design and operating principle
The OPTIMA system developed by WISY essentially operates with two pressure
pumps: The submersible pump (or „loading pump“) of the OPTIMA system is
installed in the storage tank. It is equipped with a fine suction filter and a float
switch. The loading pump pumps the rainwater to the normal-suction, multi-
stage centrifugal pump in the wall unit. As a result of the admission pressure,
the centrifugal pump is required only to pump and the mains water top-up inlet
pipe remains closed.
If a valve at one appliance (e.g. toilet flushing system) is opened, the pressure in
the circuit drops. When the factory-set pump starting pressure (1.5 bar) on the
automatic switch is reached, both pumps of the rainwater unit start up. When
the valves at all appliances are closed again, the pump control system (automa-
tic switch) turns off both pumps when the operating pressure is reached.
Note: If a „drip irrigation“ system (often computer-controlled) is to be connected
as an appliance to the OPTIMA, a small expansion vessel (around 15 l capacity)
must be installed downstream of the wall unit in the rainwater circuit. The expan-
sion vessel used for this purpose must be of the „flow-through“ type.
Switchover to mains water top-up is fully automatic. If the storage tank is empty,
the flow switch turns off the loading pump. Since the admission pressure then
drops to zero, mains water is automatically sucked out of the top-up tank of the
OPTIMA system. The water level in the top-up tank then falls, causing the float
valve for the mains water inlet to open so that mains water can be supplied to
the centrifugal pump.
If it is necessary to temporarily operate the OPTIMA system exclusively in mains
water operation (e.g. to carry out maintenance on the storage tank), then the
loading pump need only be electrically disconnected from the wall unit (remove
plug from socket on OPTIMA unit!).
The mains water top-up system is implemented as an open outlet in accordance
with DIN EN 1717 (formerly DIN 1988/4). Furthermore, a continuous exchange of
water takes place automatically in the mains top-up tank.
The tank can be topped up with approximately 95 litres of mains water per minu-
te if required. The mains water top-up tank has a storage capacity of 9 litres and
is also fitted with an emergency overflow (DN 70) as an additional precaution.
A pressure gauge in the sight glass of the OPTIMA indicates the relevant system
pressure at which the rainwater unit is currently operating.
When the system is completely empty of water, the dry run protection system
integrated in the automatic switch shuts down both pumps.
Shutdown of loading pump
Water exchange in the mains water
top-up tank
Operating pressure indicator
Integrated dry run protection
8
Maintenance and servicing
6-monthly control
● Inspect the water circuit connections for leaks
● Perform a function test on the pumps and check the system
pressure indicator
● Test the pump start and stop points set on the automatic switch
● Check the level indicator (compare actual tank fill level with
indicated fill level)
● Perform function test on mains water top-up system, for example, by
disconnecting the electrical power supply to the loading pump at the
wall unit and opening a valve at an appliance at the same time
● Inspect the mains water inlet; if necessary, clean the dirt trap at the
inlet of the float valve and the dirt trap at the isolating valve
● Check the fine suction filter (inspect visually and clean if necessary)
● Inspect the vertical float switch at the loading pump (if necessary,
clean the filter at the casing of the vertical float switch)
If it is necessary to perform maintenance work in the storage tank, the
electrical supply to the submersible pump must be disconnected.
Repairs
All repair work must be carried out by the manufacturer or by contractors
whohave been explicitly approved.
Repairs, modifications to components or modifications to the OPTIMA
installation carried out by unauthorized persons shall invalidate the guarantee!
The OPTIMA rainwater unit must be
disconnected from the mains power
supply before any maintenance work is
carried out on the open storage tank.
Compliance with the safety instructions
(see heading „Safety instructions“ in this
document) is absolutely essential
!
Materials
Horizontal, multi-stage centrifugal pump
●Stainless steel 1.4301 (pump casing, casing cover)
●Nickel-plated brass (screw plug (for filling))
●Stainless steel 1.4401 (pump shaft)
●NORYL (impeller)
●Aluminium alloy (motor enclosure)
Submersible pump
●Stainless steel 1.4301 (outer casing, motor enclosure,
bottom cover, suction foot, base plate)
●Stainless steel 1.4305 (pump shaft)
●NORYL (pump casing, handle, top bearing, impeller)
●Polypropylene (float switch)
Mains water top-up tank
●Polystyrene (tank)
●KTW-approved plastic (float valve)
Floating fine suction filter (FFSF)
●Stainless steel 1.4301 (suction strainer)
●Polyurethane (suction tube)
●Polyethylene (float)
Automatic switch
●Polyamide, polypropylene (casing)
Screw connections, pump connections, valve
●Brass, stainless steel
Connecting hoses
●Natural rubber with stainless steel braiding
OPTIMA casing
●Stainless steel (base frame)
●Polystyrene (cover)
9
Troubleshooting guide
Type of fault Cause Remedy
OPTIMA is not supplying
water to the appliance(s)
a) The storage tank is empty
and the mains water con-
nection is closed (air suction,
dry run protection is active).
b) The automatic switch does
not start the pumps.
c) The pump is blocked.
d) Power supply to OPTIMA
is interrupted.
a) Absperrventil am TW-An-
schluß zur OPTIMA öffnen.
Haube abziehen und fest
installierte Pumpe über
Auffüllstutzen neu befüllen.
Schraube zudrehen. RESET-
Taste am Schaltautomaten
drücken. Pumpe startet und
schaltet bei max. Druck wie-
der aus. OPTIMA ist wieder
betriebsbereit
b) Netzstecker der OPTIMA
ziehen und wieder einste-
cken. Sofern die Störung
nicht behoben ist, bitte den
Kundendienst rufen.
c) Abhilfe wie unter b).
d) Elektroanschluß überprüfen
(eventuell hat der FI-Schutz-
schalter ausgelöst)!
Switchover from
rainwater to mains water
is not working and the
automatic switch is set
to „Fault“
a) The float valve in the mains
water top-up tank is blocked
or does not open.
b) The loading pump in the
storage tank has fallen over
when the water level was
low and the float switch has
not switched off the pump.
The pump is sucking in air.
c) The floating suction filter
is caught against the wall
of the storage tank and
the pump is drawing in air.
d) The loading pump is defective.
a) Check that the float valve is
operating correctly, clean if
necessary, contact customer
service if necessary.
b) Check the position of the
loading pump; if necessary,
change the pump position
or secure it in the correct
position.
c) Check the position of the
loading pump and the FFSF
set and change if necessary.
d) Contact customer service or
installation specialist.
OPTIMA is not producing
enough pressure
OPTIMA pumps have not been
fully vented.
Vent the pumps again.
Integral (centrifugal)
pump is running
continuously
a) Water loss of more than
0.7 l/min from the system.
b) Printed circuit board in the
automatic switch is defective.
a) Inspect the entire installa-
tion and the valves at all
appliances, seal and repair if
necessary.
b) Contact the installation spe-
cialist or customer service.
The integral (centrifugal)
pump is switching on
and off continuously
Leak in the system. Inspect all appliances supplied
by the rainwater circuit for
minor water losses (e.g. drip-
ping taps, valve failing to close
completely in toilet cistern) and
repair.
Continuous top-up with
mains water despite suf-
ficient fill level in storage
tank
a) Suction filter in submersible
pump is dirty.
b) Interruption in pumped rising
main between loading pump
and OPTIMA wall unit.
c) Interruption in electric cable
between loading pump and
automatic switch.
d) Float switch at loading pump
is blocked or defective.
e) Loading pump is defective
a) Clean external surface of
suction filter with a brush.
b) Inspect the pumped rising
main and replace if
necessary.
c) Inspect the electric cable
and replace if necessary.
d) Check whether the float
switch reaches the ON level;
contact customer service if
necessary.
e) Contact customer service.
Mains water is continuo-
usly running out through
the emergency overflow
of the mains top-up tank
(audible!)
Float valve in the mains water
top-up tank is not closing or is
clogged
Clean the valve; contact custo-
mer service if necessary.
Inadequate top-up with
mains water
The float valve in the top-up
tank is blocked or the dirt filter
at the valve inlet is clogged
Clean the float valve and/or the
dirt filter, replace if necessary
The pressure gauge
(pressure indicator) is
showing a raised pres-
sure.
An external heat source (e.g.
radiator) is causing a pres-
sure increase in the OPTIMA
system.
Contact customer service of
your installation company (it
might be necessary to install a
pressure relief valve).
10
Technical data
10
Environmental guidance
The OPTIMA is shipped in recyclable packaging. Please recycle it! Waste
electrical and electronic equipment contains valuable materials which can be
reused / recycled. Do not dispose of an old unit as general (non-recyclable)
household waste. Use the recycling centres provided in your area to return de-
fective electrical or electronic equipment so that it can be recycled!
Disposal / recycling of
transport packaging
Disposal / recycling of
old units
OPTIMA 4 bar OPTIMA 5 bar
Power consumption
- horizontal centrifugal pump
- submersible/loading pump
- Standby (W)
600 W Prisma 15/3
510 W Provedo VX
< 0,2
800 W Prisma 15/4
510 W Provedo VX
< 0,2
Mains connection
1-phase alternating current
230 V, 50 Hz 230 V, 50 Hz
Total maximum power consump-
tion for both pumps
10 A 10 A
Degree of protection
- horizontal centrifugal pump
- submersible/loading pump
- automatic switch
IP 55
IP 68
IP 44
IP 55
IP 68
IP 44
Water connections of OPTIMA
system:
-
Inlet connection of loading pump
- Mains water connection
- Outlet connection to appliances
- Suction inlet / discharge outlet
of loading pump
(OT=outside thread, IT= inside thread)
1“ OT
¾“ OT
1“ OT
1“ grommet / 1¼“ IT
1“ OT
¾“ OT
1“ OT
1“ grommet / 1¼“ IT
Sound pressure level dB
(A) (in decibels)
- in rainwater operation
- in mains water operation
52
63
57
63
Horizontal centrifugal pump
Delivery head H /Flow rate Q
Rainwater operation: Hmax / Qmin
Hmin / Qmax
Mains water operation: Hmax / Qmin
Hmin / Qmax
35 m / 20 l/min
16 m / 65 l/min
30 m / 20 l/min
8 m / 65 l/min
45 m / 20l/min
17 m / 65 l/min
40 m / 20 l/min
7 m / 65 l/min
Submersible Loading pump
Delivery head H at Q = 25 l/min
Max. immersion depth
8 m
5 m
8 m
5 m
Cut-in pressure of
automatic switch
1.5 bar 1.5 bar
Max. operating pressure in RW operation
Max. operating pressure in mains operation
4,2 bar
3,3 bar
5,3 bar
4,4 bar
Max. permissible operating pressure
8 bar 8 bar
Max. water temperature 35° C 35° C
Capacity of mains water
top-up tank
9 Liter 9 Liter
Mains water connection:
- min. inlet water pressure
- max. inlet water pressure
2,5 bar (250 kPa)
4 bar (400 kPa)
2,5 bar (250 kPa)
6 bar (= 600 kPa)
Top-up flow rate (mains pressure
rating 3 bar (300 kPa), pipe cross
section ¾“)
approx. 95 l/min approx. 95 l/min
Dimensions of OPTIMA system
Depth x width x height (in mm)
315 x 500 x 510 315 x 500 x 510
Electr. connecting cable wall unit
Electr. cable for submersible
pump
1,5 m (3x 1,0 mm²)
15 m (3x 1,00 mm²)
1,5 m (3x 1,0 mm²)
15 m (3x 1,00 mm²)
1111
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
erklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung • Konformitätserklärung •
Declaration of conformity
WISY
Rainwater Harvesting
Product name
Relevant EU directives
Applied harmonized
standards
Other applied national
standards and
specifications
Manufacturer
Authorised person with
responsibility for technical
documentation
Kefenrod, February 14, 2013
In compliance with the EU Machinery Directive 2006/42/EC,
Annex II Part 1 Section A
We hereby declare that the machines named below
comply with all provisions of version 2006/42/EC of the
EU Machinery Directive.
Multimat type 205, type 407 rainwater units
Optima 4, Optima 5, Optima Plus rainwater units
Maxima type 205, type 407 rainwater units
Sigma 3, Sigma 4 rainwater units
Delta rainwater unit
Machinery directive 2006/42/EC dated 17.05.2006
Directive 2004/108/EC relating to electromagnetic compatibility
dated 15.12.2004
EN ISO 13849-1:2008 Safety of machinery -
Safety-related parts of control systems - Part 1:
General principles for design (ISO 13849-1:2006)
EN 809:1998+A1:2009 Pumps and pump units for liquids -
Common safety requirements
EN ISO 12100:2010 Safety of machinery -
General principles for design - Risk assessment
and risk reduction (ISO 12100:2010)
EN 60204-1:2006 Safety of machinery -
Electrical equipment of machines – Part 1: General requirements
EN 60529 (VDE 0470-1) Degrees of protection provided by enclosures
DIN 1989 Rainwater harvesting systems,
Parts 1+4 DIN EN 1717 and DIN 1988-100 Drinking water protection
WISY AG
Oberdorfstraße 26
D-63699 Kefenrod
WISY AG
Oberdorfstraße 26
D-63699 Kefenrod
Arnold Denk
Managing Board
of WISY AG
Jan Maurer
Managing Board
of WISY AG
WISY AG
D-63699 Kefenrod, Oberdorfstraße 26
Telefon +49 (0) 60 54-91 21-0
Fax +49 (0) 60 54-91 21-29
Internet: www.wisy.de
E-Mail: info@wisy.de
AHA019-E-V05-30.09.2020 / Technical changes reserved
Device no.
The registered manufacturer device number of your product is as follows:
Guarantee
This guarantee is valid for a period of 24 months and becomes effective on the date
of purchase by the customer. Replacement of the product under guarantee will not
extend the original period of the guarantee.
WISY shall meet its guarantee obligations for the OPTIMA rainwater unit If it can be
demonstrated that the following conditions are fulfilled:
1. The product has been purchased from a specialist WISY retailer in the Federal
Republic of Germany.
2. The product has been commissioned by the WISY customer service or by a spe-
cialist installation company.
Claims can be made under the guarantee only if WISY receives notification in writing
of any defect within 14 days of discovery of the defect.
During the guarantee period, WISY shall repair or replace free of charge any defective
part. Additional claims for damages shall be excluded to the extent permitted by law.
Faults or defects which arise as a result of the following factors are not covered by
the guarantee:
● Faulty assembly or installation, e.g. failure to comply with the valid VDE regulations
or with the Installation Instructions.
● Failure to connect the emergency overflow of the mains top-up tank to a domestic
drainage connection or failure to provide a floor drain.
● Inappropriate use or exposure to excessive mechanical strain
● The connection of equipment other than the submersible pump supplied with the
OPTIMA system to the blue socket provided for the submersible pump.
● External influences, e.g. shipping damage, damage caused by shock impacts,
damage caused by exposure to weather or other natural phenomena.
● Repairs or modifications undertaken by unauthorized third parties
Period and commencement
of the guarantee
Terms and conditions of the
guarantee
Content and scope of the guarantee
Limitation of the guarantee

Other Wisy Water Filtration System manuals

Wisy Optima 4 Service manual

Wisy

Wisy Optima 4 Service manual

Wisy WFF 150 User manual

Wisy

Wisy WFF 150 User manual

Wisy Vortex Fine Filter WFF 150 User manual

Wisy

Wisy Vortex Fine Filter WFF 150 User manual

Wisy LineAir 100 User manual

Wisy

Wisy LineAir 100 User manual

Wisy SIGMA User manual

Wisy

Wisy SIGMA User manual

Wisy Vortex-Fine-Filter User manual

Wisy

Wisy Vortex-Fine-Filter User manual

Popular Water Filtration System manuals by other brands

Cintropur NW 18 Instructions for installation, use and maintenance

Cintropur

Cintropur NW 18 Instructions for installation, use and maintenance

Sub-Zero WS Series quick start guide

Sub-Zero

Sub-Zero WS Series quick start guide

Prozone PZ2 Series Installation guide & operation manual

Prozone

Prozone PZ2 Series Installation guide & operation manual

Aquatlantis tecatlantis CLEANSYS PRO operating manual

Aquatlantis

Aquatlantis tecatlantis CLEANSYS PRO operating manual

GRE FS550 Installation and maintenance manual

GRE

GRE FS550 Installation and maintenance manual

Sears 625.34823 owner's manual

Sears

Sears 625.34823 owner's manual

Spirax Sarco 5800 Series Installation and maintenance instructions

Spirax Sarco

Spirax Sarco 5800 Series Installation and maintenance instructions

Formula Air E-PURE ASPRA S400 Series manual

Formula Air

Formula Air E-PURE ASPRA S400 Series manual

Abundant Flow Water DFK-Mu troubleshooting guide

Abundant Flow Water

Abundant Flow Water DFK-Mu troubleshooting guide

Grohe Blue Series manual

Grohe

Grohe Blue Series manual

Master Water Conditioning MBA Series Installation and operation manual

Master Water Conditioning

Master Water Conditioning MBA Series Installation and operation manual

Zodiac TRi Series Instructions for installation and use

Zodiac

Zodiac TRi Series Instructions for installation and use

GE GXRV10ABL01 Owner's manual and installation

GE

GE GXRV10ABL01 Owner's manual and installation

Monacor FGA-40 operating instructions

Monacor

Monacor FGA-40 operating instructions

Xtant CM12L Installation

Xtant

Xtant CM12L Installation

3M 3MDW101 Installation and operating instructions

3M

3M 3MDW101 Installation and operating instructions

Dynamic Engineering CF-Eco User instructions

Dynamic Engineering

Dynamic Engineering CF-Eco User instructions

CSI Duplex SD48 Installation & operation manual

CSI

CSI Duplex SD48 Installation & operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.