Wiznet W7500S2E-R1 User manual

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual
Introduction
W7500S2E-R1 is an industrial grade serial to Ethernet module. It supports TCP server, TCP client and UDP three
operating modes. The maximum serial baud rate is 460,800Mbps. W7500S2E-R1 supports WIZS2E ConfigTool
(Configuration Tool for Windows®), web page configuration and AT command to configure the module.
W7500S2E-R1 uses W7500 MCU with hardwired TCP/IP protocol. This enable a faster, stable and secure Ethernet
connectivity. With reference schematic(s) and guideline(s) in this user manual, it could be greatly reduced the time
and difficulty of the hardware design and development when comparing with other approaches.
Features
10/100 Mbps Ethernet interface with auto-negotiation and RJ45 connector
Support TCP server, TCP client and UDP operating modes
Flexible serial interface data packaging condition settings
Smart Ethernet cable detection and keep alive features
As DHCP client to automatically acquire IP address
As DNS client to lookup domain name
Support NetBIOS allows user to identify module’s name
Support user password authorization for security
Support serial AT command configuration method
Built-in web server for browser and remote configuring
Provide user-friendly configuration tool program (WIZS2E ConfigTool)
Support firmware upgrade by ConfigTool
Specification
Serial interface: 3.3V TTL x1: TXD, RXD, GND
Default Serial communication parameters
oBaud Rate: From 300bps to 460,800bps
oData Bit: 7, 8
oStop Bit: 1, 2
oParity: None, Even, Odd
oFlow Control: None, CTS/RTS
Configuration methods
oWIZS2E ConfigTool
oWeb based (via web browser)
oSerial AT command
Power supply: Input Power: DC 3.3V
Size: 44.45 x 31.75 x 23 (mm)
Operating temperature: -40 ~ +85 ℃(Industrial Grade)
Storage environment: -40 ~ +85 ℃, 5 ~ 95% RH
Version
Date
Remarks

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual
Document Revision History
Copyright notice
Copyright © WIZnet H.K. Ltd. All rights reserved.
ContactE-mail: supports@wiznet.hk
For moreinformation,pleasevisit: http://www.wiznet.com.hk/
V1.0
2017-09-19
First release
V1.1
2018-05-30
1. Description of AT+NETBIOS command is revised
2. Parameters of AT+C1_STOPB command is changed to 0:1, 1:2
3. Maximum length of the AT+C1_SER_T command parameter is changed to 5, value
range is changed to 0~60000
4. Parameter of the Terminal check (AT) query command is removed
5. Replace all "/n/r " in the text with "\r\n"
6. Maximum length of the AT+C1_BIND command parameter is changed to 1
7. Maximum length of the AT+C1_TCPAT command parameter is changed to 3
8. Description of the AT+NAME command is updated
9. Chapter 2.2: Pin 2 of SW3 description in changes from GND to Vcc; picture has also
been modified
10. Updated Figure 2-4 Evaluation Board Reference Design Schematic
11. Maximum length of the AT+MAC command parameter is removed
12. Stop Bit is changed to 1, 2 in the specification
13. Power supply is changed to DC 3.3V in the specification
14. Chapter 1.2.2: "upper and lower parts" is changed to "left and right"
15. Chapter 7.2: Baud Rate and Stop Bit is revised
16. Chapter 7.3: Device Name has maximum length 15 bytes
17. Chapter 7.4: Password has maximum length 15 bytes
18. Power supply is changed to DC 3.3V
19. Maximum length of the AT+DEFAULT and AT+RESET command parameters in the
list of AT commands is modified to 15
20. Default value of AT+DEBUGMSGEN parameter is modified to 1
21. Chapter 5.3, WIZS2E ConfigTool new function introduction is added
22. All WIZS2E ConfigTool screen captures are updated

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual I
Table of Contents
1INTRODUCTION ........................................................................................................... 1
1.1.1 Configuration methods ....................................................................................... 1
1.2 SPECIFICATIONS.......................................................................................................... 1
1.2.1 Electrical characteristics.................................................................................... 1
1.2.2 Dimensions ......................................................................................................... 1
1.2.3 Thermal Characteristics..................................................................................... 1
2HARDWARE DESCRIPTION....................................................................................... 3
2.1 PINOUTS AND PIN DESCRIPTION.................................................................................. 3
2.2 WIZS2E EVALUATION BOARD .................................................................................... 5
2.3 QUICK TESTING GUIDE................................................................................................ 7
3OPERATING MODES.................................................................................................... 8
3.1 TCP SERVER MODE ..................................................................................................... 8
3.2 TCP CLIENT MODE...................................................................................................... 8
3.3 UDP MODE ................................................................................................................. 9
4IP ADDRESS .................................................................................................................. 10
4.1 MODULE IP ADDRESS FACTORY DEFAULT SETTINGS................................................. 10
4.2 METHOD TO GET THE IP ADDRESS OF THE MODULE ................................................. 10
4.3 MODULE AND HOST COMPUTER NETWORK DETECTION ............................................11
4.4 HOW TO SET THE IP ADDRESS OF THE HOST COMPUTER ........................................... 12
5WIZS2E CONFIGTOOL.............................................................................................. 13
5.1 COLLECT MODULE’S SETTING INFORMATION ........................................................... 13
5.2 MODIFY THE DEVICE SETTINGS ................................................................................ 14
5.3 FACTORY RESET........................................................................................................ 15
5.3.1 Factory reset setting by software...................................................................... 15
5.3.2 Factory reset module through AT command..................................................... 15
5.3.3 Hardware factory reset method ........................................................................ 16
5.4 FIRMWARE UPGRADE ............................................................................................... 16
6AT COMMAND CONFIGURATION.......................................................................... 17
6.1 AT COMMAND OVERVIEW......................................................................................... 17
6.2 ENTER AT COMMAND MODE.................................................................................... 18
6.3 AT COMMAND LIST ................................................................................................... 18
6.3.1 System control command list ............................................................................ 18
6.3.2 Control command list........................................................................................ 18
6.3.3 Serial configuration command list.................................................................... 19
6.4 AT COMMAND DETAILS............................................................................................. 21
6.4.1 Basic commands ............................................................................................... 21
6.4.2 Control commands............................................................................................ 21
6.4.3 Device configuration command list.................................................................. 23
6.4.4 Serial control command.................................................................................... 28

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual II
6.5 AT COMMAND CONFIGURATION EXAMPLES ............................................................. 31
6.5.1 Set into TCP server mode example................................................................... 31
6.5.2 TCP client mode example ................................................................................. 33
6.5.3 UDP mode example.......................................................................................... 34
7WEB PAGE CONFIGURATION................................................................................. 35
7.1 MAIN PAGE ............................................................................................................... 35
7.2 BASIC SETTINGS ....................................................................................................... 37
7.3 ADVANCE SETTINGS ................................................................................................. 38
7.4 DEVICE MANAGEMENT ............................................................................................. 40
8FIRMWARE UPGRADE .............................................................................................. 42
8.1 W7500S2E-R1 FIRMWARE UPGRADE THROUGH CONFIGTOOL................................ 42

W7500S2E-R1 user manual 1
1Introduction
1.1.1 Configuration methods
W7500S2E-R1 provides three types configuration methods for user to operate with the module.
WIZS2E ConfigTool is a computer software configuration tool. It can be installed and
run in Windows® environment.
Web page configuration allows user locally or remotely to configure the module through
web browser.
AT command configuration support sending serial commands from the mainboard of the
embedded device or from the serial terminal to configure the parameters of WIZS2E
modules.
1.2 Specifications
1.2.1 Electrical characteristics
1.2.1.1 Voltage and current characteristics
The following table 1-1 and 1-2 was the result tested in 25oC environment.
Table 1-1 Voltage and current characteristics
1.2.1.2 Current characteristics
Table 1-2 Current characteristics
1.2.2 Dimensions
For fitting the module into your design, please refer to the reference figure 1-1; It shows all the
dimensions of the modules. In the figure, it provides the regulation for three dimensions with the
distance of left and right pin headers and the location of the one mounting holes. The pin header
has pitch 2.54mm.
Symbol
Types
Ratings
Min
Normal
Max
Unit
VDD
Module Voltage
2.97
3.3
3.6
V
I
Module Current
101
106
157
mA
Working Mode
Ratings (mA)
Working Mode
Ratings (mA)
Standby
101
100Mbps without connection
157
10Mbps without connection
106
100Mbps with data communication
157
10Mbps with data communication
106

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 2
Figure 1-1 W7500S2E-R1 dimensions top view
Figure 1-2 W7500S2E-R1 dimensions side view
1.2.3 Thermal Characteristics
Table 1-3 Thermal characters
Part Number
Grade
Operating temperature
Storage temperature
W7500S2E-R1
Industrial Grade
-40 ~ +85 ℃
-40 ~ +85 ℃

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 3
2 Hardware description
2.1 Pin assignment
The following section will introduce W7500S2E-R1 pin header explanation and the usage of
WIZS2E evaluation board.
The following figure 2-1 is the appearance of WIZS2E module. From this figure, we could
identify there are 2 rows of pin headers on the module as hardware connectors for users. J1 is a
1x12 single row 2.54mm pin and J2 is 1x11 single row 2.54mm pins.
Figure 2-2 is the pin assignment of W7500S2E-R1, table 2-1 and 2-2 are the pin header
description of W7500S2E-R1 module.
Figure 2-1 W7500S2E-R1 module
Figure 2-2 W7500S2E-R1 pinout

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 4
Table 2-1 W7500S2E-R1 J1 pin definition
Pin No.
Pin Name
I/O
Function
1
NC11
-
-
2
NC10
-
-
3
NC9
-
-
4
NC8
-
-
5
DATA_LED
O
Ethernet Status Indicator
6
TXD
O
Serial output signal
7
RXD
I
Serial input signal
8
RTS
I/O
Serial RTS signal
9
DEFAULT
I
Active low, pull down over 3s for factory reset
10
RESET
I
Hardware reset pin
11
GND
-
GND
12
GND
-
GND
Table 2-2 W7500S2E-R1 J2 pin definition
Pin No.
Pin Name
I/O
Function
13
VCC
-
VCC
14
VCC
-
VCC
15
LINK_LED
O
Ethernet link indicator
16
NC7
-
-
17
NC6
-
-
18
NC5
-
-
19
NC4
-
-
20
NC3
-
-
21
CTS
I/O
Serial CTS signal pin
22
NC2
-
-
23
NC1
-
-

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 5
2.2 WIZS2E evaluation board
Figure 2-3 WIZS2E evaluation board
WIZS2E evaluation board provides a simple platform for testing and running an application for
WIZS2E modules including W7500S2E-R1. Where Z1-J1 and Z1-J2 are used to plug in the
W7500S2E-R1 module, S1-J1 and S1-J2 are used to plug in other models of WIZS2E module (s),
which are described in the user manuals of the related modules. The evaluation board integrates
RJ45, serial TTL and USB mini interfaces. (The following figure shows “x” means vacant)
Note: When the evaluation board is connected to the W7500S2E-R1 module, the RJ45 on the
evaluation board is disabled automatically.
TTL interface (P2) Pin Assignment
Pin
Signal
Pin
Signal
1
5V
5
3V3
2
GND
6
GND
3
TX
7
RTS
4
RX
8
CTS
USB Mini Interface (J6) Pin Assignment supply 5 V DC power for the evaluation board only.
Note: Not for debug or communication
Pin
Signal
Pin
Signal
1
5V
4
×
2
×
5
GND
3
×
SW3 is power supply pin for other modules, it would be leave open for W7500S2E-R1
Pin
Signal
Pin
Signal
1
5V
3
3V3
2
Vcc
W7500S2E-R1 evaluation board buttons introduction
Marking
Description
SW1 (DEFAULT)
Press switch for 1-3 seconds for soft reset, over 3 seconds to factory reset
SW2 (RESET)
Hardware reset button
Table 2-4 W7500S2E-R1 evaluation board button description
W7500S2E-R1 evaluation board LED description
1 2 3 4
5 6 7 8

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 6
Marking
Description
ACT
Ethernet status indicator
LINK
Ethernet connection indicator
DATA
Ethernet data communication LED, the Blink speed shows the data speed
Table 2-5 W7500S2E-R1 evaluation board LED description
Hardware connection explanation
W7500S2E-R1 used two sections of pin layouts in 1 x 12 pin and 1 x 11 pin designs. This is to avoid
plugging the module in the wrong directing which may damage to the module.
Figure 2-4 shows the reference schematic of the evaluation board for developing reference.
Figure 2-4 W7500S2E-R1 evaluation board reference schematic

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 7
2.3 Quick testing guide
WIZS2E module can upgrades products or devices from serial interface to Ethernet interface.
Evaluation board can be used for a quick test before implement the module into the design. By
connection the serial interface to the module and Ethernet interface connected to the host
computer, the user could easily control the serial device through Ethernet as the figure 2-5.
E t h e r n e t
Serial
User Device
PC
Serial Serial
W7500S2E-R1
User Device User Device
W7500S2E-R1 W7500S2E-R1
Figure 2-5 W7500S2E-R1 module testing evaluation block diagram
Using LAN cables and USB to Serial (TTL)cables to connect from the host computer and to the
respective LAN ports and TTL ports of the evaluation board. This will create a simple testing
network; The IP address of the host computer's wired network card is changed according to the
4.4 chapters, the user can send/receive data through the network port, receive/send from the
serial port, and conduct a simple testing and evaluation.

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 8
3 Operating modes
WIZS2E module supports TCP server, TCP client and UDP modes; Below demonstrate
these operating modes.
3.1 TCP server mode
TCP/IP
RS232 Serial
①Link REQEUST ②Data
Communication
TCP Client
TCP Server User Device
Figure 3-1 TCP server mode diagram
Figure 3-1 shows, W7500S2E-R1 module open a local port to listen TCP requests in TCP server
mode. The default port number is 5000 and it is waiting for client connections. After the
connection has created, it will start data communication.
3.2 TCP client mode
TCP/IP
RS232 Serial
①Link REQUEST ②Data
Communication
TCP Server
TCP Client User Device
Figure 3-2 TCP client mode diagram
According to figure 3-2, W7500S2E-R1 module will starts to connect to TCP server that set in
the module for TCP client mode. If connection fails, client will base on reconnection setting
condition and try to connect with the TCP server. After its connected, it will start data
communication.

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 9
3.3 UDP mode
TCP/IP
RS232 Serial
Data
Communication
without Link
User Device
Figure 3-3 UDP mode diagram
For UDP mode in Figure 3-3, W7500S2E-R1 module is required to have the remote IP address
and port number to create an UDP communication. UDP mode communicate is not based on
“connection”. Therefore, it does not guarantee the target device could receive the data correctly
or not. Thus, it requires an upper layer communication protocol to communicate for ensuring the
data accuracy. However, since UDP mode is a simple communication protocol, it could provide a
better communication speed due to less workload on data accuracy. In fact, UDP are not likely to
get data error in network environment under normal workload. In this operating mode, both
devices are equal, and they do not differentiate into server or client.

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 10
4 IP address
Before using the module, we need to know some parameters like IP address. This module
support “Static” and “DHCP” IP collection method. For “Static” mode, user could manually
change the IP address, subnet mask & gateway parameters. The emphasis here is that the IP
address of the module cannot be the same as the IP address of other devices in the same LAN. i.e.
the module will activate DHCP protocol to collect IP address, subnet mask and gateway
information from the DHCP server.
4.1 Module IP address factory default settings
WIZS2E Serial to Ethernet module’s factory default IP address: 192.168.1.88.
4.2 Method to get the IP address of the module
No matter forgotten the IP address of the module or the module is working on DHCP mode, the
current IP address of the module could be searched using the WIZS2E ConfigTool. The
following steps are the method to use WIZS2E ConfigTool to search the IP address for WIZS2E
module:
1. Connect the host computer and the module with LAN cable and power up the module.
2. Run the WIZS2E ConfigTool and it shows as the following 4-1 figure.
Figure 4-1 WIZS2E ConfigTool interface
3. Press button, it shows the IP address information as the following figure 4-2.

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 11
Figure 4-2 WIZS2E ConfigTool search result
4.3 Module and host computer network detection
Before starting to communicate between the WIZS2E module and the host computer, please
ensure the host computer and the module are in the same network segment.
The factory default setting for IP address and Subnet mask in WIZS2E module are 192.168.1.88
and 255.255.255.0 respectively. User could follow the flow diagram 4-3 to understand the
communication procedure between the module and the host computer. If they are in the same
network segment, it could communicate with the module. Otherwise, the host computer needs to
change its IP address to communicate with the module.
W7500S2E-R1 IP Address
192.168.1.88 and
W7500S2E-R1 Submask
255.255.255.0
PC Submask
?and
PC IP Address
?
W7500S2E-R1 Subnet
192.168.1.0
PC Subnet
?
Compare
Use W7500S2E-R1 to Communicate Change IP Address
Different SubnetThe Same Subnet
Figure 4-3 WIZS2E module and IP segment of host computer flow diagram

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 12
4.4 How to set the IP address of the host computer
The following procedure is based on Windows® 7 Operation System.
Press “Start” → “Control Panel” → “Network Sharing Centre” → “Changing adaptor setting” →
“Local connection” → Right Click “Properties” → Double Click “Internet protocol version 4
(TCP/IPv4)”. After all these procedures, you could get into the result as the following figure
shows. Please choose “Using the following IP addresses” for inputting the IP address as
192.168.1.99, the subnet mask is 255.255.255.0 and default gateway into 192.168.1.1. The DNS
section could ignore. Finally, please click “Enter” for saving these settings and starts to
communicate with WIZS2E module.
Figure 4-4 Window 7 (Chinese version) IP address setting interface

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 13
5 WIZS2E ConfigTool
WIZS2E ConfigTool is a Windows® configuration tool compatibles to W5500S2E and
W7500S2E series modules. WIZS2E ConfigTool can be used to search, enquiry and configure
W5500S2E and W7500S2E device features and information.
5.1 Collect module’s setting information
Click the toolbar’s button, WIZS2E ConfigTool will search all WIZS2E module that
has connected in the same network segment (Direct connect or under the same router). The
figure 5-1 shows the result as mentioned. The search section shows all the modules in MAC
address format as the parent node for the list of information of WIZS2E module. By pressing the
“ ” button, it shows the detail information about this module. After pressing the MAC address
of that specific module, it will list out all the IP address, serial interface settings and other
parameters of this module. This information presents on the Basic settings and Advance Option
tab that were next to the search section.
Note: Prior configuration, it is recommended that you disable other unrelated network adapters in
your host computer (including virtual network adapters, if you use the wired network adapter
configuration module to turn off the wireless network card) and ensure that all device IP
addresses in the LAN are not conflicting.
Figure 5-1 WIZS2E ConfigTool basic settings interface

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 14
Figure 5-2 WIZS2E ConfigTool advance options interface
5.2 Modify the device settings
After searching the module, user could directly go to “Basic Settings” and “Advance Options” to
configure the module. Please press button to save your configuration.
5.3 Useful features
5.3.1 Switching Ethernet Interface
To solve the issue that it is impossible to determine whether the wired or wireless
network interface is currently used when configuring the module, the tool has added
a function of switching the network interface. User can set the network card to
search and configure according to the actual situation, click “Update IP list!” The list of network
interfaces can be updated.
5.3.2 Right mouse button
Right-click on the device list on the left, and the function list will appear as shown in the figure
below. There are 3 functions:
1. Expand/collapse all device details
2. The searched devices are sorted by MAC/device type/device name

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 15
3. “Search again!”: This function is convenient for users to keep the original device list
unchanged when batch configuring devices, and the newly searched device information
is list below the original device list.
Figure 5-1 Right mouse click menu
5.4 Factory reset
If the customer found out some uncertainties with the WIZS2E module, the user could reset the
module back to factory default setting to solve the problem. There are three kinds of method to
factory: Software (ConfigTool), AT command and hardware reset.
5.4.1 Factory reset setting by software
I. In the WIZS2E ConfigTool, please click the module on the search section that needs to
factory reset.
II. Please press toolbar’s → factory reset button to reset the
module back to default settings.
5.4.2 Factory reset module through AT command
For detail information about this AT command (AT+DEFAULT) for factory reset, please refer
section 6.4.2.6.

W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual 16
5.4.3 Hardware factory reset method
5.4.3.1 Factory reset through evaluation board
Figure 5-2 The evaluation board reset button
After providing power to the module, please press the DEFAULT button for more than 3 seconds
to apply factory reset procedure.
5.4.3.2 Factory reset through module
Figure 5-3 through the module default PIN to restore factory settings
W7500S2E-R1 has a restored factory set PIN. After power on the module, pull down the
DEFAULT pin for 3 seconds to activate factory default.
5.5 Firmware Upgrade
W7500S2E-R1 supports host computer firmware upgrade. For detail information, please refer
section 8 Firmware upgrade.
Table of contents
Other Wiznet Control Unit manuals

Wiznet
Wiznet WizFi210 User instructions

Wiznet
Wiznet W7100 Debugger User manual

Wiznet
Wiznet WIZ810Sio User manual

Wiznet
Wiznet IGM7100 User manual

Wiznet
Wiznet W5500S2E User manual

Wiznet
Wiznet WIZ610io User manual

Wiznet
Wiznet WIZ120SR User manual

Wiznet
Wiznet WIZ140SR User manual

Wiznet
Wiznet WIZ1000 User manual

Wiznet
Wiznet WIZ200WEB User manual

Wiznet
Wiznet EG-SR-7100A User manual

Wiznet
Wiznet WIZ610wi User manual

Wiznet
Wiznet WIZ630wi User manual

Wiznet
Wiznet W7500S2E Series User manual

Wiznet
Wiznet WIZ105SR User manual

Wiznet
Wiznet WIZ620wi User manual

Wiznet
Wiznet W5500S2E-S1 User manual

Wiznet
Wiznet WIZ107SR User manual

Wiznet
Wiznet WizFi630 Installation instructions

Wiznet
Wiznet WIZ820io User manual