SPECIFICATIONS
Gas Supply
Installation must conform with local codes and ordinances.
Locate the gas supply as shown in the illustrations on
page 4.
The cooktop is equipped for use with natural or liquid pro-
pane (LP) gas. The product rating plate has information on
the type of gas that should be used. For rating plate loca-
tion, refer to the illustration below. If this information does
not agree with the type of gas available, check with the local
gas supplier.
Prior to installation, ensure that the local distribution condi-
tions (nature of the gas and gas pressure) and the adjust-
ment of the appliance are compatible. The adjustment
conditions for this appliance are stated on the label (or
rating plate). The data plate can be found on the underside
of the cooktop.
This appliance is not connected to a combustion prod-
ucts evacuation device. It shall be installed and connected
in accordance with current installation regulations. Par-
ticular attention shall be given to the relevant requirements
regarding ventilation.
The cooktop must be connected to a regulated gas supply.
The supply line must be equipped with an approved external
gas shut-off valve located near the cooktop in an accessible
location. Do not block access to the shut-off valve. Refer to
the illustration below.
GAS SUPPLY REQUIREMENTS
NATURAL GAS
Gas Supply Pressure 12.5 mb
Min Line Pressure 17.5 mb
Max Pressure to Regulator 100 mb
LP GAS
Gas Supply Pressure 25 mb
Min Line Pressure 27.4 mb
Max Pressure to Regulator 100 mb
GAS RATING
MODEL
TOTAL HEAT
OUTPUT
GAS
UNITS
APPLIANCE
CATEGORY
TYPES AND
PRESSURE (mbar) COUNTRY OF DESTINATION
ICBGC152T/S 6.2 kW
I2H G20 at 20 AT, CZ, DK, FI, GR, HR, IS, IE, IT, PT, SK, SI, ES, SE, CH,
TR, GB, EE, LV, LT, NO, RO
I2E G20 at 20 DE, LU
I2E+ G20 at 20/25 BE, FR
ICBCG152T/S/LP 6.2 (443) kW (g/h) I3P G31 at 37 CH, CZ, DE, IT, ES, FI, GR, GB, NL, SK, IE, SI, RO, PL,
LV, LT
ICBCG304T/S 14.2 kW
I2H G20 at 20 AT, CZ, DK, FI, GR, HR, IS, IE, IT, PT, SK, SI, ES, SE, CH,
TR, GB, EE, LV, LT, NO, RO
I2E G20 at 20 DE, LU
I2E+ G20 at 20/25 BE, FR
ICBCG304T/S/LP 14.2 (1014) kW (g/h) I3P G31 at 37 CH, CZ, DE, IT, ES, FI, GR, GB, NL, SK, IE, SI, RO, PL,
LV, LT
ICBCG304P/S 14.2 kW
I2H G20 at 20 AT, CZ, DK, FI, GR, HR, IS, IE, IT, PT, SK, SI, ES, SE, CH,
TR, GB, EE, LV, LT, NO, RO
I2E G20 at 20 DE, LU
I2E+ G20 at 20/25 BE, FR
ICBCG304P/S/LP 14.2 (1014) kW (g/h) I3P G31 at 37 CH, CZ, DE, IT, ES, FI, GR, GB, NL, SK, IE, SI, RO, PL,
LV, LT
ICBCG365T/S 16.9 kW
I2H G20 at 20 AT, CZ, DK, FI, GR, HR, IS, IE, IT, PT, SK, SI, ES, SE, CH,
TR, GB, EE, LV, LT, NO, RO
I2E G20 at 20 DE, LU
I2E+ G20 at 20/25 BE, FR
ICBCG365T/S/LP 16.9 (1207) kW (g/h) I3P G31 at 37 CH, CZ, DE, IT, ES, FI, GR, GB, NL, SK, IE, SI, RO, PL,
LV, LT
ICBCG365P/S 16.9 kW
I2H G20 at 20 AT, CZ, DK, FI, GR, HR, IS, IE, IT, PT, SK, SI, ES, SE, CH,
TR, GB, EE, LV, LT, NO, RO
I2E G20 at 20 DE, LU
I2E+ G20 at 20/25 BE, FR
ICBCG365P/S/LP 16.9 (1207) kW (g/h) I3P G31 at 37 CH, CZ, DE, IT, ES, FI, GR, GB, NL, SK, IE, SI, RO, PL,
LV, LT
A gas supply line of 19 mm rigid pipe must be provided to
the cooktop. If local codes permit, a certied, .9 m long,
13 mm or 19 mm ID exible metal appliance connector is
recommended to connect the units 1/2" NPT (or ISO 7/1-14)
male inlet to the gas supply line. Pipe joint compounds, suit-
able for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of 100
mbar. The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off valve
during any pressure testing of the system at test pressures
equal to or less than 100 mbar.
Wolf natural gas cooktops will function up to 3124 m in
altitude without adjustment and LP gas cooktops will func-
tion up to 2621 m. If the installation exceeds these eleva-
tions, contact your authorized Wolf dealer for a high altitude
conversion kit.
WARNING
FOR AUSTRALIA ONLY:
•The appliance must be connected to a regulated
gas supply with an approved regulator.
•This appliance can be installed using a 10 mm
diam-eter 1000 mm flexible hose assembly
complying with AS/NZS 1869, Class ‘B. Maximum
working pressure 14 kPa, ambient temperature: -20°
C to 125°C and AGA approved. The hose is not
provided with the appliance.
•If installing with a flexible hose, verify the hose is not
kinked or can be damaged. If installing above and
oven, use a hose that will not be damaged by the
heat from the oven.
•Failure to locate this appliance without proper clear-
ances will result in a fire hazard.
•Model ICBCG152TF/S has an internal regulator that has
TPP of 1kPa for Natural Gas and 2.5kPa for LPG
commissioning should be completed with both burners on
higb.
SHUT-OFF VALVE
OPEN POSITION
GAS SUPPLYTO APPLIANCE
Rating plate location. Gas shut-off valve.
RATING PLATE
GAS RATING—AUSTRALIA ONLY
MODEL GAS TYPE GAS PRESSURE MJ/h ULTRA RAPID RAPID SEMI RAPID
ICBCG152TF/S Natural 1.0 kPa 24.5 N/A 1.80 / 0.65 mm 1.60/0.65mm
LP 2.75 kPa 23.5 N/A 1.06/ 0.47 mm 0.93 / 0.41 mm
ICBCG304 Natural 1.0 kPa 47.3 2.05 / .79 mm 1.59 / .65 mm 1.40 / .65 mm
LP 2.75 kPa 47.8 1.18 / .47 mm .94 / .47 mm .82 / .41 mm
ICBCG365 Natural 1.0 kPa 56.4 2.05 / .79 mm 1.59 / .65 mm 1.40 / .65 mm
LP 2.75 kPa 56.9 1.18 / .47 mm .94 / .47 mm .82 / .41 mm
Note - ICBCG152 TF/S has an on board regulator which regulates the operating pressure for Natural Gas @ 1kPa and Propane (LPG) @ 2.5kPa.
Commisioning Proceedure is with both burners set to maximum.
Not applicable for Australia