xpr BIOPAD-M User manual

BIOPAD-M Biometric Keypad Reader
a Company Visual CorporationPlus
User’s Manual
EN
v.a2

1. DESCRIPTION
2. SPECIFICATIONS
3. MOUNTING
4. WIRING
5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER
5.1 CONNECTING BIOMETRIC READERS IN SAME RS485 LINE WITH THE EWS CONTROLLERS
5.2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP/IP COMMUNICATION
6. CONNECTING BIOMETRIC READERS TO 3RD PARTY CONTROLLER
6.1 CONVERTERS PIN DESCRIPTION
7. ENROLLMENT
8. CONFIGURING THE BIOMETRIC READERS IN PROS SOFTWARE
8.1 ADDING BIOMETRIC READER
8.2 ENROLLING FINGERPRINTS FROM A READER
8.3 ENROLLING FINGERPRINTS FROM DESKTOP READER
8.4 DELETING FINGERPRINTS
8.5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
8.6 FIRMWARE UPDATE
8.7 ENTRY MODE
8.7.1 Finger or PIN Code
8.7.2 Finger and PIN Code
8.7.3 Finger Only
8.8 CHANGE PIN CODE LENGTH
8.9 SENSOR CALIBRATION
8.10 SEND CONFIGURATION
8.11 ADVANCED SETTING
9. CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER
9.1 ADD READER
9.2 EDIT READER
9.3 DELETE READER
9.4 CALIBRATE SENSOR
9.5 ADD USER
9.6 EDIT USER
9.7 DELETE USERS
9.8 ENROLL FINGERS
9.9 UPLOAD FINGERPRINTS TO READER
9.10 DELETE FINGERPRINTS
9.10.1 Deleting one user from the biometric reader
9.10.2 Deleting all users from the biometric reader
9.11 COMPLEX USER UPLOAD
9.12 CUSTOM WIEGAND
10. WIEGAND PROTOCOL DESCRIPTION
11. SAFETY PRECAUTIONS
12. TROUBLESHOOTING
Contents
2
www.visual-plus.com
3
3
4
5
5
6
6
7
7
8
8
8
9
10
11
13
12
12
13
13
13
14
15
15
15
16
16
17
18
18
18
18
19
19
19
20
20
20
20
21
22
23
23

1. DESCRIPTION
BIOPAD-M is a Wiegand biometric keypad for access control applications with backlit keys and programmable wiegand output.
It offers storage up to 9500 fingerprints, programmable Wiegand Output (8 to 128 bits) and selectable PIN Code length.
The tamper switch output can trigger the alarm system, if an attempt is made to open or remove the unit from the wall.
2. CARATTERISTICHE
Capacità memoria
Tecnologia
Tipo autenticazione
Impronte per utente
Lunghezza codice PIN
Protocollo
Programmazione protocollo
Massima distanza cablaggio
Tipologia sensore biometrico
9500 impronte
Biometrico e Tastiera
Impronta, codice PIN, Impronta e/o codice PIN
1-10 impronte
1- 8 Numeri
Wiegand da 8 a 128 bits; Default: Wiegand 26 bit
con PROS software (sistemi con EWS); BIOMANAGER (tutti i sistemi di controllo accessi)
50m
Capacitivo
< 1 sec
da lettore o dal lettore da tavolo collegato in USB al pc (BIOE)
Cavo, 1m
Controllati esternamente
Modalità inattività
Si
Si, settabile da software
Si
Massimo 130mA
Tempo di identificazione
Memorizzazione impronte
Connessioni pannello
LED verde rosso
LED arancione
Buzzer
Retroilluminazione ON/OFF
Tamper
Consumi
Grado IP
Alimentazione
Temperatura di funzionamento
Dimensioni (mm)
Contenitore
Colore
65
9-14V DC
-15°C to +60°C
100 x 94 x 30
Alluminio
Argento
3
www.visual-plus.com

Cable
Ø6.0
30mm
100 mm
94 mm
30 mm
3. MOUNTING
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the ATP polycarbonate cover available in our
accessories in order to protect the sensor from direct rainfall. The operating temperature of the product is between -15ºC - + 60ºC.
If the reader is installed in an environment where the temperature can drop below -10ºC or/and if the sensor could only be exposed
to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box (fitted with additional
heater if very low temperature) to keep a constant sensor level performance. XPR™ cannot guarantee the functionality of the
product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also
the possibility to use different readers depending on users.
4
www.visual-plus.com

B
12V DC
LED Green -
D0
D1
LED Red -
GND
A
Tamper
Tamper
RS485
Orange
Yellow
Red
Black
Pink
Violet
Green
Gray
Blue
White WIEGAND
4. WIRING
LR-
LG-
- The Biometric readers can be connected to virtually any controller that conforms to Wiegand format standards (standard Wiegand
26bit or self-defined Wiegand).
- The lines D0 and D1 are the Wiegand lines and the Wiegand Number is sent through them.
- The RS485 line (A, B) is used for fingerprint transfer and reader settings.
- The Biometric readers must be powered from the controller.
- If you use different power supply for the biometric reader, connect the GND from the both devices to ensure correct transfer of
the wiegand signal
- When you have connected the reader and powered on, the LED should flash in orange light + 2 beeps. This lets you know it's on
and ready for use.
- Fingerprint enrollment is done from the PC Software. Connection between the Biometric readers and the PC must be established.
LD16
R55
C41
C28
L2
R36
LD20
R18
R25
R24
C40
R10
C34
L10
L11
C18
C33
R9
C42
C1
R5
R45
C43
C44
R28
R21
C45
D13
LD14
R46
C3
C5
R38
ZD3 C29
L9
LD13
R14
ZD4 C32
R19
R37
ALD17 ALD19
ALD18
L7
C27
L6
C16
C15
RX4
D5
D10
R32 R33 R35
R49
IC6
ZD5
ZD6
R22
L3
R53
R34
TAS1
IC11
R15
IC15
R3
R4
L8
R47
FUSE1
IC8
R20
R16
R11
C2
X1
C4
IC7 ICN2
R1
C13
C12
ICN1
R23
R48
A
LD5
RE1 RE3
A
LD8
X3
IC1
C6
U5
L5
L4
RE4RE2
A
LD6 A
LD9
ZD2
LD15
R13
ZD1
R54
R50
R6
IC12 R17
R7
R62
ALD23
D3
D2
RX3
J1
Rb6
R2
LD21
IC2
H1 ALD22
BAT
U1
IC5
FUSE2
IC3
U4
A
A
IC1
A
A
A
A
Earth
screw
Free Led 1
Free Led 2
GND
12V out
D0
D1
Free Led 1
Free Led 2
GND
12V out
D0
D1
Door Sensor2
Door Sensor1
Exit Button1
Exit Button2
GND
GND
Free In 2 -
Free In 2 +
Free In 1 -
Free In 1 +
Rx Tx Busy System
OK
Door 1 Door 2 Free Out 1 Free Out 2
TCP/IP Earth
12Vdc Out
12V
gnd
D1
D0
12V
gnd
led2led1
12V
IN1
IN1
IN2
IN2
+
-
+
-
D1
D0
12V
gnd
led2led1
PB2
PB1 DS2DS1
gnd gnd
COM
NC1NO1 NC2NO2
COM
COM
NC3NO3 NC4NO4
COM
GND
BA
gnd
Fuse
Ser No: 11-04-16-013
Mac: 00-04-A3-16-90-D
RoHS
3 3 6 1 1 1 0 1 3 1
pink
violet
green
orange
black
red
white
yellow
50m. max
B
+12V
LG-
D1
D0
LR-
GND
A
5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER
5
www.visual-plus.com
Tricolor LED (Red, Green, Orange)
12V DC
GND
Tamper
Tamper
Tamper Switch(NO)
9-14V DC
ground
D1
D0
Data 1
Data 0
LR- Red LED -
LG- Green LED -
A
B
RS485 A
RS485 B
Tamper Switch(NO)

TCP/IP
50m
max.
50m
max.
50m
max.
Switch
5.1 CONNECTING BIOMETRIC READERS IN SAME RS485 LINE WITH THE EWS CONTROLLERS
The Biometric readers are connected through RS485 bus. The same RS485 bus that the EWS controllers are connected to.
Maximum units in one network (EWS + Biometric readers) is 32.
If there are more than 32 units in one network, please utilize RS 485 HUB to connect.
The RS485 Line should be configured in the form of a daisy chain, NOT in a form of a star. If star must be used in some points, keep
the stubs from the RS485 backbone as short as possible. Maximum length of the stub is dependant of the installation (total
number of devices in RS485 line (total cable length, termination, cable type...) so recommendation is to keep stubs shorter than
5 meters, keeping in mind that this can be possible reason for errors in communication with PC software
The cable must be twisted and shielded with a min. 0.2 mm2 cross section.
Connect the ground (0V) of each unit in the RS 485 Line using a third wire in the same cable.
The shield of the communication cable between two devices must be connected to the EARTH from ONE side of the RS 485 Line.
Use the side that has earth connection to the building’s grounding network.
RS485
Jumper for
RS485 termination
1 km max / 32 Units (EWS + Biometric Readers)
50 ohm 50 ohm
TCP/IP gnd gnd
Stub
max. 5m
Jumper for
RS485 termination
5.2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP/IP COMMUNICATION
When all the controllers are connected via TCP/IP, then the RS485 network becomes local (from Reader 1 to the Controller then
to the Reader 2).
Connect the readers directly to the Rs485 terminals in each controller.
If the distance Reader-Controller is high (50meters) and if the communication with the reader can not be established, then
terminate the RS485 network by closing the jumper in the EWS Controller or as described in chapter 4.
6
www.visual-plus.com

6. CONNECTING BIOMETRIC READERS TO THIRD PARTY CONTROLLERS
BIOMANAGER Software
RS485 A
RS485 B
A
B
3rd party controller
- + D0 D1 - + D0 D1
3rd party controller
- + D0 D1 - + D0 D1
CNV100
CNV200
CNV300
BIOE
USB Desktop Reader
optional
Connect the lines D0, D1, Gnd and +12V to the third party controller.
Connect the RS485 Line (A, B) to the converter. Connect the converter in the PC.
Fingerprint enrollment is done from the PC Software. Connection between the Biometric readers and the PC must be established.
The Biometric readers communicate with each other with a RS485 and with the PC Software through a Converter.
The RS485 Line should be configured in the form of a daisy chain, NOT in a form of a star. Keep the stubs from the RS485 backbone
as short as possible (not more than 5 meters)
Only one converter per installation is needed, not per reader.
Biometric Reader Converter
RS 485 A
RS 485 B
PIN 1 (RS 485 +)
PIN 2 (RS 485 -)
CNV100
Converter RS485 to RS232
Does not requires installation
CNV200
Converter RS485 to USB
Requires installation as USB serial
device (refer to CNV200 Manual). The
Drivers are located on the CD.
CNV300
Converter RS485 to TCP/IP
Does not require installation. IP
address set through Internet
Browser(refer to CNV300 Manual)
6.1 CONVERTERS PIN DESCRIPTION
PIN 1
PIN 1 PIN 1
7
www.visual-plus.com

7. ENROLLMENT
8. CONFIGURING THE BIOMETRIC READERS IN PROS CS SOFTWARE
1. Expand the Door item to view the readers
2. Right click on the reader and select properties (8.1)
3. In the Basic tab, for “Type” of the Reader select “BIOPAD-M”. (8.2)
4. After selecting the type, a third tab will appear “Biometric”. Go to that tab and put the serial number of the Biometric
Reader. (8.3)
Important Note: The serial number of the reader can be found on a sticker inside the reader, on the packaging box and it can
be search from the software (right click on the portal/search devices/readers). (8.4 & 8.5)
To check if the reader is On Line, right click on the reader and select “Check version”. In the Event Window a message should
appear “Device ON Line, Type: BIOPAD-M” (8.6)
BIOPAD-M
BIOC3
8.1
8.2
8.3
8.4
8.5
8.6
8.1 ADDING BIOMETRIC READER
8
www.visual-plus.com

1. Open the Users Window and create a new user.
Click on “New User”, put a name, ID(card number) and Access Code.(8.7)
2. Go to the “Biometric” Tab
3. Select the reader(with left click) from which the enrollment will be done. (8.8)
4. Right click on the fingertip and select enroll. (8.9)
5. In the next 25 sec. present the finger on the selected reader and the finger tip will turn red, with the percentage of
successful enrollment shown next to the fingertip. (8.10)
In these 25 sec. the reader will continuously blink in orange.
6. Repeat point 4&5 for each finger that should be enrolled.
7. Click on “Save New” and the fingerprint will be sent automatically to all Biometric Readers where that user has access, i.e. to
all the readers according to the Access Level assign to that user.
Example:
If the user has “Unlimited” Access level then the fingerprints will be sent to all readers, if the user has Access level only for
Reader1 and Reader 3 then the fingerprints will be sent only to those two readers.
Note:
To check if all the fingerprints are sent to the reader, right click on the reader and select “Memory Status”. (8.11)
In the event window a line will appear indicating the number of fingerprints stored in the reader. (8.12)
Note:
If more fingerprints are added for one user, all fingerprints will send the same Wiegand Code to the controller, the one written
in the field User ID(card Number).
8.7
8.8
8.10
8.9
8.11
8.12
8.2 ENROLLING FINGERPRINTS FROM A READER
9
www.visual-plus.com

Plug the Desktop Reader (BIOE) in the PC. If the device is not installed automatically use the drivers located on the CD provided
with the Biometric reader. It is installed in the same way as a USB Device. When the desktop reader has been installed it will
automatically appear in the Software. (8.13)
1. Open the Users Window and create a new user.
Click on “New User”, put a name, ID(card number) and Access Code. 8.7)
2. Go to the “Biometric” Tab
3. Select the USB desktop Reader (with left click).
4. Place the finger on the BIOE, right click on the fingertip and select enroll. (8.9)
5. The finger tip will turn red, with the percentage of successful enrollment shown next to the fingertip. (8.10)
6. Repeat point 5 for each finger that should be enrolled.
7. Click on “Save New” and the fingerprint will be sent automatically to all Biometric Readers where that user has access, i.e. to all
the readers according to the Access Level assign to that user.
If the reader is off line, the fingers will be sent upon the connection is established between PROS server and the reader. No need for
additional enrollment or actions. The fingerprints will be sent as soon as communication is established.
Example:
If the user has “Unlimited” Access level then the fingerprints will be sent to all readers, if the user has Access level only for Reader1
and Reader 3 then the fingerprints will be sent only to those two readers.
Note:
To check if all the fingerprints are sent to the reader, right click on the reader and select “Memory Status”. (8.11)
In the event window a line will appear indicating the number of fingerprints stored in the reader. (8.12)
Note:
If more fingerprints are added for one user, all fingerprints will send the same Wiegand Code to the controller, the one written in
the field User ID(card Number).
8.10
8.11
8.12
8.3 ENROLLING FINGERPRINTS FROM DESKTOP READER
8.9
8.138.7
10
www.visual-plus.com

In General, the fingerprints are stored in the Biometric reader and in the Software.
Deleting can be done only in the readers or from both places.
Deleting one user from the biometric reader
Select the User
Click on “Delete User”. The User together with its fingerprints will be deleted from both the software and the
fingerprint readers. (8.14)
Deleting all users from the biometric reader
Right click on the reader and select “Delete all users from reader” (8.15)
Delete one or more fingerprints
Select the User and open the “Biometric” tab
Go to the fingertip that needs to be deleted, right click and select ”Delete” for one finger or “Delete All” for all fingers
of the User.
Click “Save Changes”.
With this procedure the User's fingerprints are deleted from the software and from the reader. (8.16)
8.15
8.16
8.4 DELETING FINGERPRINTS
8.14
11
www.visual-plus.com

Right click on the biometric reader
Select “Upload all users to reader”
While receiving the fingerprints the reader will blink in orange.
Note: Use this feature when you change or add a reader, if pending tasks are deleted in the software or if there are doubts that
fingerprints in the reader memory are not synchronized with the software database.
In normal usage, the fingerprints are sent automatically and this feature is not used.
8.17
Right-click on the reader and select Firmware update menu (8.18)
On the Firmware update window, click on the Browse button (8.19). The default location of the firmware files installed with
PROS CS is in the folder "Firmware".
Select the firmware file with a "xhc" extension.
Click on the Upload button
Important: Wait for the update end message. Do not turn off the reader, the software or any communication device in between
during the entire process.
8.18 8.19
8.5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
8.6 FIRMWARE UPDATE
www.visual-plus.com 12

Right click on the biometric reader
Select “Properties” and go to the “Biometric” tab
For Entry Mode select “Access Code or Finger” (8.20)
8.20
8.21
8.7 ENTRY MODE
Right click on the biometric reader
Select “Properties” and go to the “Biometric” tab
For Entry Mode select “Access Code and Finger” (8.21)
Use of the double security mode:
Type the PIN Code (ex. 3434), in the next 8 sec. the
reader will blink in orange waiting for the finger.
Present the finger.
8.7.2 Finger and PIN Code
Right click on the biometric reader
Select “Properties” and go to the “Biometric” tab
For Entry Mode select “Finger” (8.22)
Note:
In this mode the keypad will become inactive.
8.7.3 Finger Only
8.21
8.22
8.7.1 Finger or PIN Code
www.visual-plus.com 13

Go to Settings/ System parameters. (8.24)
Select the desired length and click “Save&Exit”. (8.25)
All the readers in the network will automatically receive the change
Note: It is recommended to do this setting immediately after installing the software, as this parameter will set the available number
of PIN Code digits in the user form.
Example: If the PIN code length is set to 6 digits, then in the Users Window, the PIN Code will require 6 digits entry. (8.26)
8.24
8.25
8.8 CHANGE PIN CODE LENGTH
8.26
www.visual-plus.com 14

Send This ID for:
Unknown Finger sends the desired Wiegand when an
unknown finger is applied.
Unknown PIN sends the desired Wiegand when an
unknown Pin Code is applied.
Button “A” Pressed sends the desired Wiegand when
button “A” is pressed.
Button “B” Pressed sends the desired Wiegand when
button “B” is pressed.
Click on the Save & Exit button
Sound level:
Sound level of the device (ON or OFF)
Finger Acceptance Flexibility:
Accepted tolerance. The recommended value is
“Automatic Secure”.
Sensitivity:
Bio-sensor sensitivity, the recommended value is 7,
most sensitive.
Right click on the biometric reader and select
“Calibrate” and wait for confirmation message.
Note: It is recommended to do a calibration while
commissioning the reader and in cases when there are
problems with reading the fingers
· Right-click on the reader and select the Send
configuration menu
· See the events panel to check the configuration flow
Note: The biometric reader gets its settings
automatically. This function is used if the reader was off
line while making the changes.
8.11 ADVANCED SETTINGS
8.9 SENSOR CALIBRATION
8.10 SEND CONFIGURATION
www.visual-plus.com 15

9 CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER
BioManager is software for fingerprint management of XPR Biometric readers, when used with third party access controllers.
Main functions:
- Fingerprint Enrollment
It can be done by ANY Biometric reader in the network or by Desktop (USB) Biometric reader.
Note: The Desktop Biometric reader BIOE is only compatible to Biometric readers with capacitive sensor, not with the ones
with thermal sensor.
- Fingerprint Transfer
Finger templates can be sent to any Reader in the Network. Different Users can be sent to different Biometric readers.
- PIN Codes management and transfer
PIN Code length configuration (1 to 8 digits) and PIN Code transfer.
- Wiegand Output Configuration
The Wiegand output of the Biometric reader can be customized bitwise.
9.1 ADD READER
Right-click on the portal connected to the
reader and select Add reader
Fill the Reader form
Click on Save and the reader icon appears
under the selected portal Right-click on reader and select Version info
www.visual-plus.com 16

If reader is online, new line is added on top of the event table
If reader is not online, following line is added on top of the event table
If reader is online, right click on reader and select Upload configuration
Check at event table if configuration was successful
9.2 EDIT READER
Right-click on the reader and select Properties Edit reader properties and click Save button
Right click on the reader and select Upload configuration
Check at event table if configuration was successful
www.visual-plus.com 17

9.3 DELETE READER
Right-click on the reader and select Delete reader
9.4 CALIBRATE SENSOR
9.5 ADD USER
Right-click on the reader and select Calibrate
See the events panel to check the calibration flow
It is recommended to do sensor calibration once after reader is mounted. Clean the fingerprint sensor before calibration.
At user table, click on the last empty user field and enter user name
Click on ID (User code) field and enter ID number. This number will be sent by the reader to the access controller when user
finger is recognized by the reader
Click on PIN code field and enter the PIN. PIN code is used at readers with keypad. When PIN code is typed at reader, User ID
will be sent to the access controller
9.6 EDIT USER
Find the user at user table to edit
Click on the user field for edit (Name, ID or PIN)
Type new value
Press Enter on the keyboard
Important:
When ID is changed, warning message is displayed reminding that if ID exist in some reader, should be deleted from
reader prior to change.
www.visual-plus.com 18

Check the users to be deleted
Right-click on the users table
Click on Delete checked users menu
Confirm warning message
9.8 ENROLL FINGERS
Select the User in the User Column, not the check box (the check box is for sending
the fingerprints) and the User name cell will turn blue
Select the Biometric reader or Desktop reader BIOE from where the enrollment
will be done
Right click on the fingertip and
select Enroll
Swipe the finger on the Reader and the finger tip will become blue, with
percentage of successful enrollment given right beside the fingertip
Note: If more fingerprints are added for one user, all fingerprints will send the same Wiegand Code to the controller.
9.9 UPLOAD FINGERPRINTS TO READER
Check the users which fingerprints will be sent to the Reader
Right-click on the Biometric reader those users should be sent and select Upload users
As each user is being sent, the checkbox will become unchecked indicating
that the user is successfully sent. In the same time the orange LED of the
Biometric reader blinks
Note: Average time for transferring one finger template is 0,6 sec.
Note: The PIN Codes are also being sent, if there are any.
www.visual-plus.com 19
9.7 DELETE USERS

9.10 DELETE FINGERPRINTS
After the transfer, the fingerprint are stored in the Biometric reader and in the PC.
Deleting can be done only in the software, only in the readers or from the both places.
9.10.1 Deleting one user from the biometric reader
Select the users checkbox.
Right click on the Reader and select Delete Users
The user is deleted from the reader, but his fingerprints are still in the software's database. They can be sent ones again without the
need of re enrollment.
9.10.2 Deleting all users from the biometric reader
Right click on the Reader and select Delete all
9.11 COMPLEX USER UPLOAD
Complex user upload is used to sent multiply user selection to more readers
Click on Upload table at main menu
www.visual-plus.com 20
Table of contents
Other xpr Keypad manuals
Popular Keypad manuals by other brands

Extel
Extel WECACV70003 Installation and user guide

Samsung
Samsung DS 5000 Series Quick reference guide

Texecom
Texecom Premier RKP8 Plus installation manual

Toshiba
Toshiba Compliant Manager BMS-CM1280TLE installation manual

Lasermet
Lasermet ICS-KP12 instruction manual

Storm
Storm AXS Code Master installation instructions

Dorma
Dorma AC217 installation instructions

Securitron
Securitron DK-16W Installation & operating instructions

Chamberlain
Chamberlain Clicker KLIK2U user manual

Alarm Controls Corporation
Alarm Controls Corporation KP-100A manual

AAS
AAS ADVANTAGE DKE 26-100L User & installation manual

Sony
Sony PlayStation 3 CECHZK1GB instruction manual