Yaesu FTDX 1200 Series Product guide

FTDX1200 SerieS
CAT OperATiOn
reFerenCe BOOk
YAESU MUSEN CO., LTD.

USB Cable
(Supplied w/SCU-17)
Personal Computer
FTDX1200
SCU-17
RS-232C Cable
(Supplied w/SCU-17)
Overview
The CAT (Computer Aided Transceiver) System in the
FTDX1200 transceiver provides control of frequency,
VFO, memory, and other settings such as dual-channel
memories and diversity reception using an external per-
sonal computer. This allows multiple control operations
to be fully automated with single mouse clicks, or key-
stroke operations on the computer keyboard.
Using the RS-232C Cable (Refer to gure 1)
The FTDX1200 series has a built-in level converter, al-
lowing direct connection from the rear-panel CAT jack
to the serial port of your computer without the need of
any external boxes.
You will need a serial cable for connection to the RS-
232C (serial or COM port) connector on your computer.
Purchase a standard serial cable (not the so-called “null
modem” type), ensuring it has the correct gender and
number of pins (some serial COM port connectors use a
9-pin rather than 25-pin conguration). If your computer
uses a custom connector, you may have to construct the
cable. In this case, refer to the technical documentation
supplied with your computer for correct data connection.
Using the USB Cable with SCU-17 (Refer to gure 2)
Install the virtual COM port driver on the personal
computer before using the SCU-17 USB interface unit.
Please see the USB Driver (Virtual COM Port Driver)
on the Yaesu Website for details refer to (http://www.
yaesu.com/) in the FTDX1200 product les section.
Note: Do not connect the USB cable and SCU-17 to
your personal computer until after the “virtual
COM port driver” installation is completed, be-
cause an incorrect driver may be installed.
The SCU-17 interface unit may be used for CAT control
of the transceiver with a computer via a USB connec-
tion. You will need a USB cable to connect to the USB
jack on your computer.
YAESU MUSEN does not produce CAT System
operating software due to the wide variety of per-
sonal computers and operating systems in use today.
However, the information provided in this chapter
explains the serial data structure and opcodes used
by the CAT system. This information, along with
the short programming examples, is intended to help
you start writing programs on your own. As you
become more familiar with CAT operation, you can
customize programs for your operating needs and
utilize the full operating potential of this system.
COnneCTiOn
pin nO.
pin nAme
N/A
SERIAL OUT
SERIAL IN
N/A
GND
N/A
RTS
CTS
N/A
FunCTiOn
---
Outputs the Serial Data from the
transceiver to the computer.
Inputs the Serial Data from the
computer to the transceiver.
---
Signal Ground
---
When the computer is not ready
to receive data, this port goes
to “L” to inhibit the transmit data
from the transceiver.
When the transceiver is not ready
to receive data, this port goes
to “L” to inhibit the transmit data
from the computer.
---
I/O
---
Output
Input
---
---
---
Input
Output
---
CAT (CompuTer Aided TrAnsCeiver)operATion
Personal Computer
FTDX1200
RS-232C “Straight” Cable
FTDX1200 CAT Operation Manual1
FIGURE 1
FIGURE 2

FTDX1200 CAT Operation Manual2
CAT (CompuTer Aided TrAnsCeiver)operATion
Control Command
A computer control command is composed of an alpha-
betical command, various parameters, and the terminator
that signals the end of the control command.
Example: Set the VFO-A frequency to 14.250000 MHz.
FA 14250000 ;
Command Parameter Terminator
There are three commands for the FtdX1200 as shown
below:
Set command: Set a particular condition
(to the FtdX1200)
Read command: Reads an answer
(from the FtdX1200)
Answer command: Transmits a condition
(from the FtdX1200)
For example, note the following case of the FA com-
mand (Set the VFO-A frequency):
To set the VFO-A frequency to 14.250000 MHz, the
following command is sent from the computer to the
transceiver:
“FA14250000;” (Set command)
To read the VFO-A frequency, the following com-
mand is sent from the computer to the transceiver:
“FA;” (Read command)
When the Read command above has been sent, the
following command is returned to the computer:
“FA14250000;” (Answer command)
Alphabetical Commands
A command consists of 2 alphabetical characters.
You may use either lower or upper case characters. The
commands available for this transceiver are listed in the
“PC Control Command Tables” on the following pages.
Parameters
Parameters are used to specify information necessary to
implement the desired command.
The parameters to be used for each command are pre-
determined. The number of digits assigned to each
parameter is also predetermined. Refer to the “Control
Command List” and the “Control Command Tables” to
congure the appropriate parameters.
When configuring parameters, be careful not to make
the following mistakes.
For example,
when the correct parameter is “IS0+1000” (IF SHIFT):
IS01000;
Not enough parameters specied (No direction (+)
given for the IF shift)
IS0+100;
Not enough digits (Only three frequency digits
given)
IS0_+_1000;
Unnecessary characters between parameters
IS0+10000;
Too many digits (Five frequency digits given)
Note: If a particular parameter is not applicable to the
FtdX1200, the parameter digits should be lled using
any character except the ASCII control codes (00 to
1Fh) and the terminator (;).
Terminator
To signal the end of a command, it is necessary to use
a semicolon (;). The digit where this special character
must appear differs depending on the command used.

FTDX1200 CAT Operation Manual3
CAT (CompuTer Aided TrAnsCeiver)operATion
PB
PC
PL
PR
PS
QI
QR
QS
RA
RC
RD
RF
RG
RI
RL
RM
RO
RS
RT
RU
SC
SD
SF
SH
SM
SQ
SV
TS
TX
UL
UP
VD
VF
VG
VM
VS
VX
XT
ZI
Command Set read anS.
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
X
O
X
O
O
O
O
O
O
X
O
O
O
O
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
O
X
X
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
X
O
O
O
X
O
O
O
X
O
O
O
X
O
O
O
O
O
X
X
X
O
X
X
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
X
O
O
O
X
O
O
O
X
O
O
O
X
PLAY BACK
POWER CONTROL
SPEECH PROCESSOR LEVEL
SPEECH PROCESSOR
POWER SWITCH
QMB STORE
QMB RECALL
QUICK SPLIT
RF ATTENUATOR
CLAR CLEAR
CLAR DOWN
ROOFING FILTER
RF GAIN
RADIO INFORMATION
NOISE REDUCTION LEVEL
READ METER
ROTATOR
RADIO STATUS
CLAR
CLAR UP
SCAN
SEMI BREAK-IN DELAY TIME
SUB-DIAL FUNCTION
WIDTH
S METER
SQUELCH LEVEL
SWAP VFO
TXW
TX SET
UNLOCK
UP
VOX DELAY TIME
uTUNE FILTER
VOX GAIN
[V/M] KEY FUNCTION
VFO SELECT
VOX
TX CLAR
ZERO IN
FunCtion ai
X
O
O
O
X
X
X
X
O
X
X
O
O
O
O
O
X
O
O
X
O
O
O
O
O
O
X
O
O
O
X
O
O
O
X
O
O
O
X
AB
AC
AG
AI
AM
AN
BA
BC
BD
BI
BP
BS
BU
BY
CH
CN
CO
CS
CT
DA
DN
DT
ED
EK
EM
EN
EU
EX
FA
FB
FR
FS
FT
GT
ID
IF
IS
KM
KP
KR
KS
KY
LK
LM
MA
MC
MD
MG
ML
MR
MS
MW
MX
NA
NB
NL
NR
OI
OS
PA
Command Set Read anS.
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
O
X
O
O
X
O
O
O
X
O
X
O
X
O
O
X
X
O
X
O
O
O
O
O
X
O
X
X
O
X
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
O
X
O
O
O
O
O
O
X
O
O
O
O
O
O
O
O
X
O
O
O
X
O
X
O
X
O
O
X
X
O
X
O
O
O
O
O
X
O
X
X
O
X
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
O
X
O
O
O
O
O
O
X
O
O
O
O
O
O
O
O
VFO-A TO VFO-B
ANTENNA TUNER CONTROL
AF GAIN
AUTO INFORMATION
VFO-A TO MEMORY CHANNEL
ANTENNA NUMBER
VFO-B TO VFO-A
AUTO NOTCH
BAND DOWN
BREAK-IN
MANUAL NOTCH
BAND SELECT
BAND UP
BUSY
CHANNEL UP/DOWN
CTCSS NUMBER
CONTOUR
CW SPOT
CTCSS
DIMMER
DOWN
DATE AND TIME
ENCORDER DOWN
ENT KEY
ENCODE MEMORY
ENCODE
ENCORDER UP
MENU
FREQUENCY VFO-A
FREQUENCY VFO-B
FUNCTION RX
FAST STEP
FUNCTION TX
AGC FUNCTION
IDENTIFICATION
INFORMATION
IF-SHIFT
KEYER MEMORY
KEY PITCH
KEYER
KEY SPEED
CW KEYING
LOCK
LOAD MESSEGE
MEMORY CHANNEL TO VFO-A
MEMORY CHANNEL
MODE
MIC GAIN
MONITOR LEVEL
MEMORY READ
METER SW
MEMORY WRITE
MOX SET
NARROW
NOISE BLANKER
NOISE BLANKER LEVEL
NOISE REDUCTION
OPPOSITE BAND NFORMATION
OFFSET (Repeater Shift)
PRE-AMP (IPO)
Function ai
X
O
O
X
X
O
X
O
X
O
O
X
X
O
X
O
O
O
O
X
X
X
X
X
X
X
X
O
O
O
O
O
O
O
X
O
O
X
O
O
O
X
O
X
X
X
O
O
O
X
O
X
O
O
O
O
O
O
O
O

FTDX1200 CAT Operation Manual4
CAT (CompuTer Aided TrAnsCeiver)operATion
AN ANTENNA NUMBER
Set 1 2 3 4 5 6 7 8 9 10
A N P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
A N P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
A N P1 P3 P4 ;
P1 0: Fixed
P2 1: ANT “1”
2: ANT “2”
P3 1: ANT “1”
2: ANT “2”
P4 0: Fixed
AG AF GAIN
Set 1 2 3 4 5 6 7 8 9 10
A G P1 P2 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
A G P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
A G P1 P2 P2 P2 ;
P1 0: Fixed
P2 000 - 255
AC ANTENNA TUNER CONTROL
Set 1 2 3 4 5 6 7 8 9 10
A C P1 P2 P3 ;
Read 1 2 3 4 5 6 7 8 9 10
A C ;
Answer 1 2 3 4 5 6 7 8 9 10
A C P1 P2 P3 ;
P1 0: Fixed P3 0: Tuner “OFF”
P2 0: Fixed 1: Tuner “ON”
2: Tuning Start
AI AUTO INFORMATION
Set 1 2 3 4 5 6 7 8 9 10
A I P1 ;
Read 1 2 3 4 5 6 7 8 9 10
A I ;
Answer 1 2 3 4 5 6 7 8 9 10
A I P1 ;
P1 0: Auto Information “OFF”
1: Auto Information “ON”
This parameter is set to “0” (OFF) automatically when the transceiver is turned “OFF”.
AM VFO-A TO MEMORY CHANNEL
Set 1 2 3 4 5 6 7 8 9 10
A M ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
BA VFO-B TO VFO-A
Set 1 2 3 4 5 6 7 8 9 10
B A ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
AB VFO-A TO VFO-B
Set 1 2 3 4 5 6 7 8 9 10
A B ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
BC AUTO NOTCH
Set 1 2 3 4 5 6 7 8 9 10
B C P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
B C P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
B C P1 P2 ;
P1 0:Fixed
P2 0: Auto Notch “OFF”
1: Auto Notch “ON”
BD BAND DOWN
Set 1 2 3 4 5 6 7 8 9 10
B D P1 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 0: Fixed

FTDX1200 CAT Operation Manual5
CAT (CompuTer Aided TrAnsCeiver)operATion
CS CW SPOT
Set
1 2 3 4 5 6 7 8 9 10
C S P1 ;
Read
1 2 3 4 5 6 7 8 9 10
C S ;
Answer
1 2 3 4 5 6 7 8 9 10
C S P1 ;
P1 0: OFF
1: ON
BI BREAK-IN
Set 1 2 3 4 5 6 7 8 9 10
B I P1 ;
Read 1 2 3 4 5 6 7 8 9 10
B I ;
Answer 1 2 3 4 5 6 7 8 9 10
B I P1 ;
P1 0: Break-in “OFF”
1: Break-in “ON”
BP MANUAL NOTCH
Set 1 2 3 4 5 6 7 8 9 10
B P P1 P2 P3 P3 P3 ;
Read 1 2 3 4 5 6 7 8 9 10
B P P1 P2 ;
Answer 1 2 3 4 5 6 7 8 9 10
B P P1 P2 P3 P3 P3 ;
P1 0:Fixed
P2 0: Manual NOTCH “ON/OFF”
1: Manual NOTCH LEVEL
P3 P2=0
000: OFF
001: ON
P2=1
001 - 400 (NOTCH Frequency : x 10 Hz )
BS BAND SELECT
Set 1 2 3 4 5 6 7 8 9 10
B S P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 00: 1.8 MHz 06: 18 MHz
01: 3.5 MHz 07: 21 MHz
02: - - - - 08: 24.5 MHz
03: 7 MHz 09: 28 MHz
04: 10 MHz 10: 50 MHz
05: 14 MHz 11: GEN
BU BAND UP
Set 1 2 3 4 5 6 7 8 9 10
B U P1 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 0: Fixed
BY BUSY
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
B Y ;
Answer
1 2 3 4 5 6 7 8 9 10
B Y P1 P2 ;
P1 0: RX BUSY “OFF”
1: RX BUSY “ON”
P2 0: Fixed
CH CHANNEL UP/DOWN
Set
1 2 3 4 5 6 7 8 9 10
C H P1 ;
Read
1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 0: Memory Channel “UP”
1: Memory Channel “DOWN”
CN CTCSS TONE FREQUENCY
Set
1 2 3 4 5 6 7 8 9 10
C N P1 P2 P2 ;
Read
1 2 3 4 5 6 7 8 9 10
C N P1 ;
Answer
1 2 3 4 5 6 7 8 9 10
C N P1 P2 P2 ;
P1 0: Fixed
P2 0 - 49: Tone Frequency Number (See Table 1)
CO CONTOUR
Set
1 2 3 4 5 6 7 8 9 10
C O P1 P2 P3 P3 ;
Read
1 2 3 4 5 6 7 8 9 10
C O P1 P2 ;
Answer
1 2 3 4 5 6 7 8 9 10
C O P1 P2 P3 P3 ;
P1 0:Fixed
P2 0: CONTOUR/APF “ON/OFF”
1: CONTOUR FREQ
2: APF FREQ
P3 P2=0
00: CONTOUR/APF “OFF”
01: CONTOUR “ON”
02: APF “ON”
P2=1
01 - 40 (CONTOUR Frequency:100 ~4000Hz)
P2=2
00 - 50 (APF Frequency:-250 ~250Hz)

FTDX1200 CAT Operation Manual6
CAT (CompuTer Aided TrAnsCeiver)operATion
00
01
02
03
04
05
06
07
08
67.0 Hz
69.3 Hz
71.9 Hz
74.4 Hz
77.0 Hz
79.7 Hz
82.5 Hz
85.4 Hz
88.5 Hz
09
10
11
12
13
14
15
16
17
91.5 Hz
94.8 Hz
97.4 Hz
100.0 Hz
103.5 Hz
107.2 Hz
110.9 Hz
114.8 Hz
118.8 Hz
123.0 Hz
127.3 Hz
131.8 Hz
136.5 Hz
141.3 Hz
146.2 Hz
151.4 Hz
156.7 Hz
159.8 Hz
27
28
29
30
31
32
33
34
35
162.2 Hz
165.5 Hz
167.9 Hz
171.3 Hz
173.8 Hz
177.3 Hz
179.9 Hz
183.5 Hz
186.2 Hz
36
37
38
39
40
41
42
43
44
189.9 Hz
192.8 Hz
196.6 Hz
199.5 Hz
203.5 Hz
206.5 Hz
210.7 Hz
218.1 Hz
225.7 Hz
45
46
47
48
49
---
---
---
---
229.1 Hz
233.6 Hz
241.8 Hz
250.3 Hz
254.1 Hz
---
---
---
---
table 1 (CtCSS tone Chart)
18
19
20
21
22
23
24
25
26
DA DIMMER
Set
1 2 3 4 5 6 7 8 9 10
D A P1 P1 P2 P2 P3 P3 ;
Read
1 2 3 4 5 6 7 8 9 10
D A ;
Answer
1 2 3 4 5 6 7 8 9 10
D A P1 P1 P2 P2 P3 P3 ;
P1 00 : Fixed
P2 01 - 02: LED Indicators Brightness Level
P3 00 - 15: TFT Display Brightness Level
EM ENCODE MEMORY
Set
1 2 3 4 5 6 7 ~ 54 55
E M P1 P2 P3 P3 P3 ~ P3 ;
Read
1 2 3 4 5 6 7 8 9 10
E M P1 P2 ;
Answer
1 2 3 4 5 6 7 ~ 54 55
E M P1 P2 P3 P3 P3 ~ P3 ;
P1 0: RTTY
1: PSK
P2: 1 - 5 : Memory Channel
P3: Message Characters (up to 50 characters)
:requires FFT-1 (option)
CT CTCSS
Set
1 2 3 4 5 6 7 8 9 10
C T P1 P2 ;
Read
1 2 3 4 5 6 7 8 9 10
C T P1 ;
Answer
1 2 3 4 5 6 7 8 9 10
C T P1 P2 ;
P1 0: Fixed
P2 0: CTCSS “OFF”
1: CTCSS ENC/DEC “ON”
2: CTCSS ENC “ON”
ED ENCORDER DOWN
Set
1 2 3 4 5 6 7 8 9 10
E D P1 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 0: MAIN ENCORDER
1: SUB ENCORDER
4: MIC/SPEED ENCORDER
5: PROC/CAR ENCORDER
6: NOTCH ENCORDER
7: CONT ENCORDER
P2 01-99: Steps
table 1
EK ENT KEY
Set
1 2 3 4 5 6 7 8 9 10
E K ;
Read
1 2 3 4 5 6 7 8 9 10
Answer
1 2 3 4 5 6 7 8 9 10
DN MIC DWN
Set 1 2 3 4 5 6 7 8 9 10
D N ;
Read
1 2 3 4 5 6 7 8 9 10
Answer
1 2 3 4 5 6 7 8 9 10
DT DATE AND TIME
Set
1 2 3 4 5 6 7 8 9 10
D T P1 P2 P2 P2 P2 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
D T P1 ;
Answer
1 2 3 4 5 6 7 8 9 10
D T P1 P2 P2 P2 P2 P2 P2 ;
P1 01 : Fixed
P2 hhmmss (24 hour time system)

FTDX1200 CAT Operation Manual7
CAT (CompuTer Aided TrAnsCeiver)operATion
EU ENCORDER UP
Set
1 2 3 4 5 6 7 8 9 10
E U P1 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer
1 2 3 4 5 6 7 8 9 10
P1 0: MAIN ENCORDER
1: SUB ENCORDER
4: MIC ENCORDER
5: PROC ENCORDER
6: NOTCH ENCORDER
7: CONT ENCORDER
P2 01-99: Steps
EX MENU
Set
1 2 3 4 5 6 7 8 n-1 n
E X P1 P1 P1 P2 P2 ~ P2 ;
Read
1 2 3 4 5 6 7 8 9 10
E X P1 P1 P1 ;
Answer 1 2 3 4 5 6 7 8 n-1 n
E X P1 P1 P1 P2 P2 ~ P2 ;
P1 : 001-196 (MENU Number)
P2 : Parameter (See Table 2 to Table 4)
P1 FunCtion P2 diGitS
001 AGC FAST-DELAY 20 ~ 4000 msec (P2= 0020 ~ 4000, 20 msec/step) 4
002 AGC MID DELAY 20 ~ 4000 msec (P2= 0020 ~ 4000, 20 msec/step) 4
003 AGC SLOW DELAY 20 ~ 4000 msec (P2= 0020 ~ 4000, 20 msec/step) 4
004 AGC AGC SLOPE 0: NORMAL 1: SLOPE 1
005 DISPLAY MY CALL Max 12 characters MAX 12
006 DISPLAY MY CALL TIME 0 ~ 5 sec 1
007 DISPLAY VFO COLOR 0: BLUE 1: SKY BLUE 2: GREEN 3: PURPLE 4: RED 5: ORANGE 6: GRAY 7: BLACK 1
008 DISPLAY TFT LAYOUT 0: TYPE 1 1: TYPE 2 1
009 DISPLAY DIMMER LED 1 ~ 2 (P2 = 01 ~ 02) 2
010 DISPLAY DIMMER TFT 00 ~ 15 2
011 DISPLAY BAR DISPLAY SELECT 0: CLAR 1: CW TUNE 2: uTUNE 1
012 DISPLAY METER TYPE SELECT 0: ANALOG 1: BAR GRAPH 1
013 DISPLAY BAR MTR PEAK HOLD 0: OFF 1: 0.5 sec 2: 1.0 sec 3: 2.0 sec 1
014 DISPLAY ROTATOR START UP 0: 0° 1: 90° 2: 180° 3: 270° 1
015 DISPLAY ROTATOR OFFSET ADJ -30° ~ 00° (P2 = 30 ~ 00, 2° step) 2
016 DVS RX OUT LEVEL 0 ~ 100 (P2 = 000 ~ 100) 3
017 DVS TX OUT LEVEL 0 ~ 100 (P2 = 000 ~ 100) 3
018 KEYER F KEYER TYPE 0: OFF 1: BUG 2: ELEKEY 3: ACS 1
019 KEYER F CW KEYER 0: NORNAL 1: REVERSE 1
020 KEYER R KEYER TYPE 0: OFF 1: BUG 2: ELEKEY 3: ACS 1
021 KEYER F CW KEYER 0: NORNAL 1: REVERSE 1
022 KEYER ELEKEY TYPE 0: ELEKEY-A 1: ELEKEY-B 1
023 KEYER CW WEIGHT 25 (1:2.5) ~ 45 (1:4.5) 2
024 KEYER BEACON TIME OFF / 1 ~ 690 sec (P2 = 000 ~ 255, 000: OFF) 3
025 KEYER NUMBER STYLE 0: 1290 1: AUNO 2: AUNT 3: A2NO 4: A2NT 5: 12NO 6: 12NT 1
026 KEYER CONTEST NUMBER 0000 ~ 9999 4
027 KEYER CW MEMORY 1 0: TEXT 1: MESSAGE 1
028 KEYER CW MEMORY 2 0: TEXT 1: MESSAGE 1
029 KEYER CW MEMORY 3 0: TEXT 1: MESSAGE 1
030 KEYER CW MEMORY 4 0: TEXT 1: MESSAGE 1
031 KEYER CW MEMORY 5 0: TEXT 1: MESSAGE 1
032 GENERAL ANT SELECT 0: BAND 1: STACK 1
033 GENERAL ANT2 SETTING 0: TRX 1: R2/1 1
034 GENERAL NB LEVEL 0 ~ 100 (P2 = 000 ~ 100) 3
035 GENERAL BEEP LEVEL 0 ~ 100 (P2 = 000 ~ 100) 3
036 GENERAL MONITOR LEVEL 0 ~ 100 (P2 = 000 ~ 100) 3
037 GENERAL MOX 0: DISABLE 1: ENABLE 1
038 GENERAL RF/SQL VR 0: RF 1: SQL 1
039 GENERAL CAT RATE 0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 1
040 GENERAL CAT TIME OUT TIMER 0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec 1
041 GENERAL CAT RTS 0: DISABLE 1: ENABLE 1
042 GENERAL MEM GROUP 0: DISABLE 1: ENABLE 1
043 GENERAL QUICK SPLIT FREQ –20 kHz ~ +00 (or –00) ~ +20 kHz (P2= -20 ~ +00 or -00 ~ +20) 3
044 GENERAL TXW DIAL SELECT 0: VFO-A 1: VFO-B 1
045 GENERAL TX TIME OUT TIMER 0 (OFF) ~ 30 min (P2= 00 ~ 30) 2
046 GENERAL µTUNE DIAL STEP 0: DIAL STEP-2 1: DIAL STEP-1 1
047 GENERAL MIC SCAN 0: DISABLE 1: ENABLE 1
048 GENERAL MIC SCAN RESUME 0 PAUSE 1: TIME 1
049 GENERAL FREQ ADJ –25 ~ +00 (or –00) ~ +25 (P2= -25 ~ +00 or -00 ~ +25) 3
050 MODE-AM AM LCUT FREQ 00: OFF 01: 100 Hz ~ 19: 1000 Hz (50 Hz steps) 2
051 MODE-AM AM LCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
052 MODE-AM AM HCUT FREQ 00: OFF 01: 700 Hz ~ 67: 4000 Hz (50 Hz steps) 2
053 MODE-AM AM HCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
054 MODE-AM AM MIC GAIN MCVR/FIX(0 ~ 100) (P2 = 1000: MCVR, 0000 ~ 0100: FIX(0 ~ 100)) 4
055 MODE-AM AM MIC SEL 0: FRONT 1: DATA 1
056 MODE-CW CW PITCH 00: 300 Hz 01: 310 Hz ~ 74: 1040 Hz 75: 1050 Hz (10 Hz steps) 2
057 MODE-CW CW LCUT FREQ 00: OFF 01: 100 Hz ~ 19: 1000 Hz (50 Hz steps) 2
table 2
EN ENCODE
Set
1 2 3 4 5 6 7 8 9 10
E N P1 P2 ;
Read
1 2 3 4 5 6 7 8 9 10
Answer
1 2 3 4 5 6 7 8 9 10
P1 0: RTTY
1: PSK
P2:
1: Message Memory “1” Playback
2: Message Memory “2” Playback
3: Message Memory “3” Playback
4: Message Memory “4” Playback
5: Message Memory “5” Playback
:requires FFT-1 (option)

FTDX1200 CAT Operation Manual8
CAT (CompuTer Aided TrAnsCeiver)operATion
P1 FunCtion P2 diGitS
058 MODE-CW CW LCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
059 MODE-CW CW HCUT FREQ 00: OFF 01: 700 Hz ~ 67: 4000 Hz (50 Hz steps) 2
060 MODE-CW CW HCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
061 MODE-CW CW AUTO MODE 0: OFF 1: 50 MHz 2: ON 1
062 MODE-CW CW BFO 0: USB 1: LSB 2: AUTO 1
063 MODE-CW CW BK-IN 0: SEMI BREAK-IN 1: FULL BREAK-IN 1
064 MODE-CW CW BK-IN DELAY 30 ~ 3000 msec (P2 = 0030 ~ 3000, 10 msec/step) 4
065 MODE-CW CW WAVE SHAPE 0: 1 msec 1: 2 msec 2: 4 msec 3: 6 msec 1
066 MODE-CW CW FREQ DISPLAY 0: DIRECT FREQ 1: PITCH OFFSET 1
067 MODE-CW PC KEYING 0: OFF 1: ON 1
068 MODE-CW QSK 0: 15 msec 1: 20 msec 2: 25 mesc 3: 30 msec 1
069 MODE-DATA DATA MODE 0: PSK 1: OTHER 1
070 MODE-DATA PSK TONE 0: 1000 Hz 1: 1500 Hz 2: 2000 Hz 1
071 MODE-DATA OTHER DISP (SSB) -3000 Hz ~ 0 ~ +3000 Hz (P2 = -3000 ~ -0000 or +0000 ~ +3000, 10 Hz steps) 5
072 MODE-DATA OTHER SHIFT (SSB) -3000 Hz ~ 0 ~ +3000 Hz (P2 = -3000 ~ -0000 or +0000 ~ +3000, 10 Hz steps) 5
073 MODE-DATA DATA LCUT FREQ 00: OFF 01: 100 Hz ~ 19: 1000 Hz (50 Hz steps) 2
074 MODE-DATA DATA LCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
075 MODE-DATA DATA HCUT FREQ 00: OFF 01: 700 Hz ~ 67: 4000 Hz (50 Hz steps) 2
076 MODE-DATA DATA HCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
077 MODE-DATA DATA MIC GAIN MCVR/FIX (0 ~ 100) (P2 = 1000: MCVR, 0000 ~ 0100: FIX(0 ~ 100)) 4
078 MODE-DATA DATA OUT LEVEL 0 ~ 100 (P2 = 000 ~ 100) 3
079 MODE-DATA DATA VOX GAIN 0 ~ 100 (P2 = 000 ~ 100) 3
080 MODE-DATA DATA VOX DELAY 30 ~ 300 ~ 3000 msec (P2 = 0030 ~ 3000, 10 msec/step) 4
081 MODE-FM FM LCUT FREQ 00: OFF 01: 100 Hz ~ 19: 1000 Hz (50 Hz steps) 2
082 MODE-FM FM LCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
083 MODE-FM FM HCUT FREQ 00: OFF 01: 700 Hz ~ 67: 4000 Hz (50 Hz steps) 2
084 MODE-FM FM HCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
085 MODE-FM FM MIC GAIN MCVR/FIX (0 ~ 100) (P2 = 1000: MCVR, 0000 ~ 0100: FIX(0 ~ 100)) 4
086 MODE-FM FM MIC SEL 0: FRONT 1: DATA 1
087 MODE-FM RPT SHIFT(28MHz) 0 ~ 1000 kHz (P2 = 0000 ~ 1000, 10 kHz/step) 4
088 MODE-FM RPT SHIFT(50MHz) 0 ~ 4000 kHz (P2 = 0000 ~ 4000, 10 kHz/step) 4
089 MODE-FM TONE FREQ 00: 67.0 Hz ~ 49: 254.1 Hz 2
090 MODE-RTY RTTY LCUT FREQ 00: OFF 01: 100 Hz ~ 19: 1000Hz (50 Hz steps) 2
091 MODE-RTY RTTY LCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
092 MODE-RTY RTTY HCUT FREQ 00: OFF 01: 700 Hz ~ 67: 4000 Hz (50 Hz steps) 2
093 MODE-RTY RTTY HCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
094 MODE-RTY RTTY POLARITY-R 0: NOR 1: REV 1
095 MODE-RTY RTTY POLARITY-T 0: NOR 1: REV 1
096 MODE-RTY RTTY OUT LEVEL 000 ~ 100 3
097 MODE-RTY RTTY SHIFT 1: 170 Hz 1: 200 Hz 2: 425 Hz 3: 850 Hz 1
098 MODE-RTY RTTY MARK FREQ 1: 1275 Hz 2: 2125 Hz 1
099 MODE-SSB SSB LCUT FREQ 00: OFF 01: 100 Hz ~ 19: 1000 Hz (50 Hz steps) 2
100 MODE-SSB SSB LCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
101 MODE-SSB SSB HCUT FREQ 00: OFF 01: 700 Hz ~ 67: 4000 Hz (50 Hz steps) 2
102 MODE-SSB SSB HCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct 1
103 MODE-SSB SSB MIC SEL 0: FRONT 1: DATA 1
104 MODE-SSB SSB TX BPF 0: 50 ~ 3000 1: 100 ~ 2900 2: 200 ~ 2800 3: 300 ~ 2700 4: 400 ~ 2600 (Hz) 5: 3000WB 1
105 MODE-SSB LSB RX CARRIER -200 Hz ~ 0 ~ +200 Hz (10Hz steps) (P2= -200 ~ -000 or +000 ~ +200) 4
106 MODE-SSB USB RX CARRIER -200 Hz ~ 0 ~ +200 Hz (10Hz steps) (P2= -200 ~ -000 or +000 ~ +200) 4
107 RX DSP APF WIDTH 0: NARROW 1: MEDIUM 2: WIDE 1
108 RX DSP CONTOUR LEVEL –40 ~ 0 ~ +20 (P2 = –40 ~ -00 or +00 ~ +20) 3
109 RX DSP CONTOUR WIDTH 01 ~ 11 2
110 RX DSP DNR LEVEL 01 ~ 15 2
111 RX DSP IF NOTCH WIDTH 0: NARROW 1: WIDE 1
112 RX DSP HF CW SHAPE 0: SOFT 1: SHARP 1
113 RX DSP HF CW SLOPE 0: STEEP 1: MEDIUM 2: GENTLE 1
114 RX DSP 6M CW SHAPE 0: SOFT 1: SHARP 1
115 RX DSP 6M CW SLOPE 0: STEEP 1: MEDIUM 2: GENTLE 1
116 RX DSP HF PSK SHAPE 0: SOFT 1: SHARP 1
117 RX DSP HF PSK SLOPE 0: STEEP 1: MEDIUM 2: GENTLE 1
118 RX DSP HF FSK SHAPE 0: SOFT 1: SHARP 1
119 RX DSP HF FSK SLOPE 0: STEEP 1: MEDIUM 2: GENTLE 1
120 RX DSP HF SSB SHAPE 0: SOFT 1: SHARP 1
121 RX DSP HF SSB SLOPE 0: STEEP 1: MEDIUM 2: GENTLE 1
122 RX DSP 6M SSB SHAPE 0: SOFT 1: SHARP 1
123 RX DSP 6M SSB SLOPE 0: STEEP 1: MEDIUM 2: GENTLE 1
124 SCOPE SCPE MODE 0: CENTER 1: FIX 1
125 SCOPE SCPE SPEED 0: FAST 1: SLOW 1
126 SCOPE SCPE AUTO TIME 0: OFF 1: 3 sec 2: 5 sec 3: 10 sec 4: 30 sec 5: 60 sec 1
127 SCOPE START DIAL SPEED 0: 0.5 k/sec 1: 1 kHz/sec 2: 2 kHz/sec 3: 4 kHz/sec 4: 8 kHz/sec 5: 16 kHz/sec 1
128 SCOPE SPAN FREQ 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
129 SCOPE FIX 1.8MHz 1.800 MHz ~ 1.999 MHz (P2 = 01800 ~ 01999, 1 kHz steps) 5
130 SCOPE FIX 1.8MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
131 SCOPE FIX 3.5MHz 3.500 MHz ~ 3.999 MHz (P2 = 03500 ~ 03999, 1 kHz steps) 5
132 SCOPE FIX 3.5MHzSPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
133 SCOPE FIX 5.0MHz 5.250 MHz ~ 5.499 MHz (P2 = 05250 ~ 05499, 1 kHz steps) 5
134 SCOPE FIX 5.0MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
135 SCOPE FIX 7.0MHz 7.000 MHz ~ 7.299 MHz (P2 = 07000 ~ 07299, 1 kHz steps) 5
136 SCOPE FIX 7.0MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
137 SCOPE FIX 10MHz 10.100 MHz ~ 10.149 MHz (P2 = 10100 ~ 10149, 1 kHz steps) 5
138 SCOPE FIX 10MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
139 SCOPE FIX 14MHz 14.000 MHz ~ 14.349 MHz (P2 = 14000 ~ 14349, 1 kHz steps) 5
140 SCOPE FIX 14MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
141 SCOPE FIX 18MHz 18.000 MHz ~ 18.199 MHz (P2 = 18000 ~ 18199, 1 kHz steps) 5
142 SCOPE FIX 18MHzSPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
143 SCOPE FIX 21MHz 21.000 MHz ~ 21.449 MHz (P2 = 21000 ~ 21449, 1 kHz steps) 5
144 SCOPE FIX 21MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
145 SCOPE FIX 24MHz 24.800 MHz ~ 24.989 MHz (P2 = 24800 ~ 24989, 1 kHz steps) 5
146 SCOPE FIX 24MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
147 SCOPE FIX 28MHz 28.000 MHz ~ 29.699 MHz (P2 = 28000 ~ 29699, 1 kHz steps) 5
table 3

FTDX1200 CAT Operation Manual9
CAT (CompuTer Aided TrAnsCeiver)operATion
P1 FunCtion P2 DIGITS
148 SCOPE FIX 28MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
149 SCOPE FIX 50MHz 50.000 MHz ~ 53.999 MHz (P2 = 50000 ~ 53999, 1 kHz steps) 5
150 SCOPE FIX 50MHzSPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz 2
151 TUNING CW DIAL STEP 0: 1 Hz 1: 5 Hz 2: 10 Hz 1
152 TUNING DATA DIAL STEP 0: 1 Hz 1: 5 Hz 2: 10 Hz 1
153 TUNING AM/FM DIAL STEP 0: 10 Hz 1: 100 Hz 1
154 TUNING RTTY DIAL STEP 0: 1 Hz 1: 5 Hz 2: 10 Hz 1
155 TUNING SSB DIAL STEP 0: 1 Hz 1: 5 Hz 2: 10 Hz 1
156 TUNING AM CH STEP 0: 2.5 kHz 1: 5 kHz 2: 9 kHz 3: 10 kHz 4: 12.5 kHz 1
157 TUNING FM CH STEP 0: 5 kHz 1: 6.25 kHz 2: 10 kHz 3: 12.5 kHz 4: 20 kHz 5: 25 kHz 1
158 TUNING 1MHz/100kHz SELECT 0: 1 MHz 1: 100 kHz 1
159 TX AUDIO PRMTRC EQ1 FREQ 00 : OFF 01: 100 02: 200 03: 300 04: 400 05: 500 06: 600 07: 700 Hz 2
160 TX AUDIO PRMTRC EQ1 LEVEL -20 ~ 0 ~ +10 (P2 = -20 ~ -00 or +00 ~ +10) 3
161 TX AUDIO PRMTRC EQ1 BWTH 01 ~ 10 2
162 TX AUDIO PRMTRC EQ2 FREQ
00: OFF 01: 700 02: 800 03: 900 04: 1000 05: 1100 06: 1200 07: 1300 08: 1400 09: 1500 Hz
2
163 TX AUDIO PRMTRC EQ2 LEVEL -20 ~ 0 ~ +10 (P2 = -20 ~ -00 or +00 ~ +10) 3
164 TX AUDIO PRMTRC EQ2 BWTH 01 ~ 10 2
165 TX AUDIO PRMTRC EQ3 FREQ 00 : OFF 01: 1500 02: 1600 03: 1700 04: 1800 05: 1900 06: 2000 ~ 18: 3200 Hz 2
166 TX AUDIO PRMTRC EQ3 LEVEL -20 ~ 0 ~ +10 (P2 = -20 ~ -00 or +00 ~ +10) 3
167 TX AUDIO PRMTRC EQ3 BWTH 01 ~ 10 2
168 TX AUDIO P-PRMTRC EQ1 FREQ 00 : OFF 01: 100 02: 200 03: 300 04: 400 05: 500 06: 600 07: 700 Hz 2
169 TX AUDIO P-PRMTRC EQ1 LEVEL -20 ~ 0 ~ +10 (P2 = -20 ~ -00 or +00 ~ +10) 3
170 TX AUDIO P-PRMTRC EQ1 BWTH 01 ~ 10 2
171 TX AUDIO P-PRMTRC EQ2 FREQ
00: OFF 01: 700 02: 800 03: 900 04: 1000 05: 11000 06: 1200 07: 1300 08: 1400 09: 1500 Hz 2
172 TX AUDIO P-PRMTRC EQ2 LEVEL -20 ~ 0 ~ +10 (P2 = -20 ~ -00 or +00 ~ +10) 3
173 TX AUDIO P-PRMTRC EQ2 BWTH 01 ~ 10 2
174 TX AUDIO P-PRMTRC EQ3 FREQ 00:OFF 01: 1500 02: 1600 03: 1700 04: 1800 05: 1900 06: 2000 ~ 18: 3200 Hz 2
175 TX AUDIO P-PRMTRC EQ3 LEVEL -20 ~ 0 ~ +10 (P2 = -20 ~ -00 or +00 ~ +10) 3
176 TX AUDIO P-PRMTRC EQ3 BWTH 01 ~ 10 2
177 TX GNRL TX MAX POWER 005 ~ 100 3
178 TX GNRL EXT AMP TUNING PWR 0: 10 1: 20 2: 50 3: 100 1
179 TX GNRL TUNER SELECT 0: INTERNAL 1: EXTERNAL 1
180 TX GNRL VOX SELECT 0: MIC 1: DATA 1
181 TX GNRL VOX GAIN 000 ~ 100 3
182 TX GNRL VOX DELAY 30 ~ 300 ~ 3000 msec (P2 = 0030 ~ 3000, 10 msec/step) 4
183 TX GNRL ANTI VOX GAIN 000 ~ 100 3
184 TX GNRL EMERGENCY FREQ TX 0: DISABLE 1: ENABLE 1
185 AF SCOPE FFT DISPLAY MODE 0: SPECTRUM 1: WATER FALL 1
186 AF SCOPE FFT ATT 0: 0 dB 1: 10 dB 2: 20 dB 1
187 DEC CW CW DECODE BW 0: 25 Hz 1: 50 Hz 2: 100 Hz 3: 250Hz 1
188 E/D RTTY RX USOS 0: DISABLE 1: ENABLE 1
189 E/D RTTY TX USOS 0: DISABLE 1: ENABLE 1
190 E/D RTTY RX NEW LINE CODE 0: CR, LF, CR+L 1: CR+LF 1
191 E/D RTTY TX AUTO CR+LF 0: DISABLE 1: ENABLE 1
192 E/D RTTY TX DIDDLE 0: OFF 1: BLANK 2: LTRS 1
193 E/D RTTY BAUDOT CODE 0: CCIT 1: US 1
194 E/D PSK PSK MODE 0: BPSK 1: QPSK 1
195 E/D PSK DECODE AFC RANGE 0: ±8 Hz 1: ±15 Hz 2: ±30 Hz 1
196 E/D PSK QPSK POLARITY REV 0: RX-N, TX-N 1: RX-R, TX-N 2: RX-N, TX-R 3: RX-R, TX-R 1
table 4
FA FREQUENCY VFO-A
Set
1 2 3 4 5 6 7 8 9 10
F A P1 P1 P1 P1 P1 P1 P1 P1
11 12 13 14 15 16 17 18 19 20
;
Read
1 2 3 4 5 6 7 8 9 10
F A ;
Answer
1 2 3 4 5 6 7 8 9 10
F A P1 P1 P1 P1 P1 P1 P1 P1
11 12 13 14 15 16 17 18 19 20
;
P1 0030000 - 56000000 (Hz)
FB FREQUENCY VFO-B
Set
1 2 3 4 5 6 7 8 9 10
F B P1 P1 P1 P1 P1 P1 P1 P1
11 12 13 14 15 16 17 18 19 20
P1 P1 P1 ;
Read
1 2 3 4 5 6 7 8 9 10
F B ;
Answer 1 2 3 4 5 6 7 8 9 10
F B P1 P1 P1 P1 P1 P1 P1 P1
11 12 13 14 15 16 17 18 19 20
P1 P1 P1 ;
P1 0030000 - 56000000 (Hz)
FR FUNCTION RX
Set
1 2 3 4 5 6 7 8 9 10
F R P1 ;
Read 1 2 3 4 5 6 7 8 9 10
F R ;
Answer
1 2 3 4 5 6 7 8 9 10
F R P1 ;
P1 0: VFO-A Band Receiver: “RX”, VFO-B Band Receiver: “OFF”
1: VFO-A Band Receiver: “Mute”, VFO-B Band Receiver: “OFF”
4: VFO-A Band Receiver: “OFF”, VFO-B Band Receiver: “RX”
5: VFO-A Band Receiver: “OFF”, VFO-B Band Receiver: “Mute”

FTDX1200 CAT Operation Manual10
CAT (CompuTer Aided TrAnsCeiver)operATion
IF INFORMATION
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
I F ;
Answer
1 2 3 4 5 6 7 8 9 10
I F P1 P1 P1 P2 P2 P2 P2 P2
11 12 13 14 15 16 17 18 19 20
P2 P2 P2 P3 P3 P3 P3 P3 P4 P5
21 22 23 24 25 26 27 28 29 30
P6 P7 P8 P9 P9 P10 ;
P1 000-117 (Memory Channel) P2 VFO-A Frequency (Hz)
P3 ClarierDirection+:PlusShift,--: Minus Shift
ClarierOffset:0000-9999(Hz)
P4 0: RX CLAR “OFF” 1: RX CLAR “ON”
P5 0: TX CLAR “OFF” 1: TX CLAR “ON”
P6 MODE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: RTTY-LSB
7: CW-R 8: DATA-LSB 9: RTTY-USB A: ----
B: FM-N C: DATA-USB
P7 0: VFO 1: Memory 2: Memory Tune 3: Quick Memory Bank (QMB) 4: QMB-MT
P8 0: CTCSS “OFF” 1: CTCSS ENC/DEC 2: CTCSS ENC
P9 00: (Fixed)
P10 0: Simplex 1: Plus Shift 2: Minus Shift
IS IF-SHIFT
Set 1 2 3 4 5 6 7 8 9 10
I S P1 -/+ P2 P2 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
I S P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
I S P1 -/+ P2 P2 P2 P2 ;
P1 0:Fixed
P2: --1000 ~ +1000 Hz (20 Hz steps)
KM KEYER MEMORY
Set
1 2 3 4 5 6 7 ~ n-1 n
K M P1 P2 P2 P2 P2 ~ P2 ;
Read
1 2 3 4 5 6 7 8 9 10
K M P1 ;
Answer
1 2 3 4 5 6 7 ~ n-1 n
K M P1 P2 P2 P2 P2 ~ P2 ;
P1 1 - 5 : Keyer Memory Channel Number
P2: Message Characters (up to 50 characters)
GT AGC FUNCTION
Set 1 2 3 4 5 6 7 8 9 10
G T P1 P2 ;
Read
1 2 3 4 5 6 7 8 9 10
G T P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
G T P1 P3 ;
P1 0: Fixed
P2 0: AGC “OFF”
1: AGC “FAST”
2: AGC “MID”
3: AGC “SLOW”
4: AGC “AUTO”
P3 0: AGC “OFF”
1: AGC “FAST”
2: AGC “MID”
3: AGC “SLOW”
4: AGC “AUTO-FAST”
5: AGC “AUTO-MID”
6: AGC “AUTO-SLOW”
FT FUNCTION TX
Set 1 2 3 4 5 6 7 8 9 10
F T P1 ;
Read
1 2 3 4 5 6 7 8 9 10
F T ;
Answer 1 2 3 4 5 6 7 8 9 10
F T P2 ;
P1 0: VFO-A Band: TX/RX (Toggle)
1: VFO-B Band: TX/RX (Toggle)
2: VFO-A Band Transmitter: TX
3: VFO-B Band Transmitter: TX
P2 0: VFO-A Band Transmitter: TX
1: VFO-B Band Transmitter: TX
KP KEY PITCH
Set 1 2 3 4 5 6 7 8 9 10
K P P1 P1 ;
Read
1 2 3 4 5 6 7 8 9 10
K P ;
Answer
1 2 3 4 5 6 7 8 9 10
K P P1 P1 ;
P1 00: 300 Hz - 75: 1050 Hz (10Hz steps)
ID IDENTIFICATION
Set
1 2 3 4 5 6 7 8 9 10
Read
1 2 3 4 5 6 7 8 9 10
ID;
Answer
1 2 3 4 5 6 7 8 9 10
I D P1 P1 P1 P1 ;
P1 0582 :FTDX1200 (optional FFT-1 is installed)
0583 :FTDX1200 (optional FFT-1 is not installed)
FS FAST STEP
Set 1 2 3 4 5 6 7 8 9 10
F S P1 ;
Read
1 2 3 4 5 6 7 8 9 10
F S ;
Answer 1 2 3 4 5 6 7 8 9 10
F S P1 ;
P1 0: VFO-A FAST Key “OFF” 1: VFO-A FAST Key “ON”
2: VFO-B FAST Key “OFF” 3: VFO-B FAST Key “ON”
4: VFO-A FAST Key “OFF”, VFO-B FAST Key “OFF”
5: VFO-A FAST Key “ON”, VFO-B FAST Key “OFF”
6: VFO-A FAST Key “OFF”, VFO-B FAST Key “ON”
7: VFO-A FAST Key “ON”, VFO-B FAST Key “ON”

FTDX1200 CAT Operation Manual11
CAT (CompuTer Aided TrAnsCeiver)operATion
LK LOCK
Set 1 2 3 4 5 6 7 8 9 10
L K P1 ;
Read
1 2 3 4 5 6 7 8 9 10
L K ;
Answer
1 2 3 4 5 6 7 8 9 10
L K P1 ;
P1 0: VFO-A DIAL Lock “OFF” 1: VFO-A DIAL Lock “ON”
2: VFO-B DIAL Lock “OFF” 3: VFO-B DIAL Lock “ON”
4: VFO-A DIAL Lock “OFF”, VFO-B DIAL Lock “OFF”
5: VFO-A DIAL Lock “ON”, VFO-B DIAL Lock “OFF”
6: VFO-A DIAL Lock “OFF”, VFO-B DIAL Lock “ON”
7: VFO-A DIAL Lock “ON”, VFO-B DIAL Lock “ON”
MD OPERATING MODE
Set 1 2 3 4 5 6 7 8 9 10
M D P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
M D P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
M D P1 P2 ;
P1 0: Fixed
P2 MODE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: RTTY-LSB
7: CW-R 8: DATA-LSB 9: RTTY-USB A: ----
B: FM-N C: DATA-USB
MC MEMORY CHANNEL
Set 1 2 3 4 5 6 7 8 9 10
M C P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
M C ;
Answer 1 2 3 4 5 6 7 8 9 10
M C P1 P1 P1 ;
P1 000 - 117: Memory Channel Number
000 - 099: Regular Memory Channel
100: P-1L
101: P-1U
116: P-9L
117: P-9U
~
LM LOAD MESSEGE
Set
1 2 3 4 5 6 7 8 9 10
L M P1 P2 ;
Read
1 2 3 4 5 6 7 8 9 10
L M P1 ;
Answer
1 2 3 4 5 6 7 8 9 10
L M P1 P2 ;
P1 0: Fixed P2 0: DVS (Recording Stop)
1: DVS (CH “1” Recording Start/Stop)
2: DVS (CH “2” Recording Start/Stop)
3: DVS (CH “3” Recording Start/Stop)
4: DVS (CH “4” Recording Start/Stop)
5: DVS (CH “5” Recording Start/Stop)
:requires DVS-6 (option)
MA MEMORY CHANNEL TO VFO-A
Set 1 2 3 4 5 6 7 8 9 10
M A ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
MG MIC GAIN
Set 1 2 3 4 5 6 7 8 9 10
M G P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
M G ;
Answer 1 2 3 4 5 6 7 8 9 10
M G P1 P1 P1 ;
P1 000 - 100
KY CW KEYING
Set
1 2 3 4 5 6 7 8 9 10
K Y P1 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 1: Keyer Memory “1”
Playback
6: Message Keyer “1”
Playback
2: Keyer Memory “2”
Playback
7: Message Keyer “2”
Playback
3: Keyer Memory “3”
Playback
8: Message Keyer “3”
Playback
4: Keyer Memory “4”
Playback
9: Message Keyer “4”
Playback
5: Keyer Memory “5”
Playback
A: Message Keyer “5”
Playback
KR KEYER
Set
1 2 3 4 5 6 7 8 9 10
K R P1 ;
Read
1 2 3 4 5 6 7 8 9 10
K R ;
Answer
1 2 3 4 5 6 7 8 9 10
K R P1 ;
P1 0: KEYER “OFF”
1: KEYER “ON”
KS KEY SPEED
Set
1 2 3 4 5 6 7 8 9 10
K S P1 P1 P1 ;
Read
1 2 3 4 5 6 7 8 9 10
K S ;
Answer
1 2 3 4 5 6 7 8 9 10
K S P1 P1 P1 ;
P1 004 - 060 (WPM)

FTDX1200 CAT Operation Manual12
CAT (CompuTer Aided TrAnsCeiver)operATion
NB NOISE BLANKER STATUS
Set 1 2 3 4 5 6 7 8 9 10
N B P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
N B P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
N B P1 P2 ;
P1 0: Fixed
P2 0: Noise Blanker “OFF”
1: Noise Blanker “ON”
2: Noise Blanker (Wide) “ON”
MW MEMORY CHANNEL WRITE
Set 1 2 3 4 5 6 7 8 9 10
M W P1 P1 P1 P2 P2 P2 P2 P2
11 12 13 14 15 16 17 18 19 20
P2 P2 P2 P3 P3 P3 P3 P3 P4 P5
21 22 23 24 25 26 27 28 29 30
P6 P7 P8 P9 P9 P10 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 Memory Channel Number(001 ~117) P2 Memory Channel Frequency (Hz)
P3 ClarierDirection+:PlusShift,--: Minus Shift
ClarierOffset:0000-9999(Hz)
P4 0: RX CLAR “OFF” 1: RX CLAR “ON”
P5 0: TX CLAR “OFF” 1: TX CLAR “ON”
P6 MODE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: RTTY-LSB
7: CW-R 8: DATA-LSB 9: RTTY-USB A: ----
B: FM-N C: DATA-USB
P7 0: (Fixed)
P8 0: CTCSS “OFF” 1: CTCSS ENC/DEC 2: CTCSS ENC
P9 00: (Fixed)
P10 0: Simplex 1: Plus Shift 2: Minus Shift
MS METER SW
Set 1 2 3 4 5 6 7 8 9 10
M S P1 ;
Read 1 2 3 4 5 6 7 8 9 10
M S ;
Answer 1 2 3 4 5 6 7 8 9 10
M S P1 ;
P1 0: COMP
1: ALC
3: SWR
4: ID
5: VDD
MX MOX SET
Set 1 2 3 4 5 6 7 8 9 10
M X P1 ;
Read 1 2 3 4 5 6 7 8 9 10
M X ;
Answer 1 2 3 4 5 6 7 8 9 10
M X P1 ;
P1 0: MOX “OFF”
1: MOX “ON”
NA NARROW
Set 1 2 3 4 5 6 7 8 9 10
M A P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
N A P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
N A P1 P2 ;
P1 0: Fixed
P2 0: OFF
1: ON
NL NOISE BLANKER LEVEL
Set 1 2 3 4 5 6 7 8 9 10
N L P1 P2 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
N L P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
N L P1 P2 P2 P2 ;
P1 0: Fixed
P2 000 - 100
MR MEMORY CHANNEL READ
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
M R P1 P1 P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
M R P1 P1 P1 P2 P2 P2 P2 P2
11 12 13 14 15 16 17 18 19 20
P2 P2 P2 P3 P3 P3 P3 P3 P4 P5
21 22 23 24 25 26 27 28 29 30
P6 P7 P8 P9 P9 P10 ;
P1 Memory Channel Number(001 ~117) P2 Memory Channel Frequency (Hz)
P3 ClarierDirection+:PlusShift,--: Minus Shift
ClarierOffset:0000-9999(Hz)
P4 0: RX CLAR “OFF” 1: RX CLAR “ON”
P5 0: TX CLAR “OFF” 1: TX CLAR “ON”
P6 MODE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: RTTY-LSB
7: CW-R 8: DATA-LSB 9: RTTY-USB A: ----
B: FM-N C: DATA-USB
P7 0: VFO 1: Memory
P8 0: CTCSS “OFF” 1: CTCSS ENC/DEC 2: CTCSS ENC
P9 00: (Fixed)
P10 0: Simplex 1: Plus Shift 2: Minus Shift
ML MONITOR LEVEL
Set 1 2 3 4 5 6 7 8 9 10
M L P1 P2 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
M L P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
M L P1 P2 P2 P2 ;
P1 0: MONI “ON/OFF”
1: MONI Level
P2 P1=0
000: MONI “OFF”
001: MONI “ON”
P1=1
001 - 100

FTDX1200 CAT Operation Manual13
CAT (CompuTer Aided TrAnsCeiver)operATion
OS OFFSET (REPEATER SHIFT)
Set 1 2 3 4 5 6 7 8 9 10
O S P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
O S P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
O S P1 P2 ;
P1 0: Fixed
P2 0: Simplex
1: Plus Shift
2: Minus Shift
: This command can be activated only with an FM mode.
PC POWER CONTROL
Set 1 2 3 4 5 6 7 8 9 10
P C P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
P C ;
Answer 1 2 3 4 5 6 7 8 9 10
P C P1 P1 P1 ;
P1 005 -100
PA PRE-AMP (IPO)
Set 1 2 3 4 5 6 7 8 9 10
P A P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
P A P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
P A P1 P2 ;
P1 0:Fixed
P2 0: IPO
1: AMP 1
2: AMP 2
PB PLAY BACK
Set 1 2 3 4 5 6 7 8 9 10
P B P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
P B P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
P B P1 P2 ;
P1 0: Fixed P2 0: DVS (Playback Stop)
1: DVS (CH “1” Playback Start/Stop)
2: DVS (CH “2” Playback Start/Stop)
3: DVS (CH “3” Playback Start/Stop)
4: DVS (CH “4” Playback Start/Stop)
5: DVS (CH “5” Playback Start/Stop)
:requires DVS-6 (option)
PL SPEECH PROCESSOR LEVEL
Set 1 2 3 4 5 6 7 8 9 10
P L P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
P L ;
Answer 1 2 3 4 5 6 7 8 9 10
P L P1 P1 P1 ;
P1 000 - 100
PR SPEECH PROCESSOR
Set 1 2 3 4 5 6 7 8 9 10
P R P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
P R P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
P R P1 P2 ;
P1 0: Speech Processor
1: Parametric Microphone Equalizer
P2 1: “OFF”
2: “ON”
OI OPPOSITE BAND INFORMATION
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
O I ;
Answer 1 2 3 4 5 6 7 8 9 10
O I P1 P1 P1 P2 P2 P2 P2 P2
11 12 13 14 15 16 17 18 19 20
P2 P2 P2 P3 P3 P3 P3 P3 P4 P5
21 22 23 24 25 26 27 28 29 30
P6 P7 P8 P9 P9 P10 ;
P1 Current Memory Channel(001 ~117) P2 VFO-B Frequency (Hz)
P3 ClarierDirection+:PlusShift,--: Minus Shift
ClarierOffset:0000-9999(Hz)
P4 0: RX CLAR “OFF” 1: RX CLAR “ON”
P5 0: TX CLAR “OFF” 1: TX CLAR “ON”
P6 MODE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: RTTY-LSB
7: CW-R 8: DATA-LSB 9: RTTY-USB A: ----
B: FM-N C: DATA-USB
P7 0: VFO 1: Memory
P8 0: CTCSS “OFF” 1: CTCSS ENC/DEC 2: CTCSS ENC
P9 00: (Fixed)
P10 0: Simplex 1: Plus Shift 2: Minus Shift
NR NOISE REDUCTION
Set 1 2 3 4 5 6 7 8 9 10
N R P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
N R P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
N R P1 P2 ;
P1 0: Fixed
P2 0: Noise Reduction “OFF”
1: Noise Reduction “ON”

FTDX1200 CAT Operation Manual14
CAT (CompuTer Aided TrAnsCeiver)operATion
QS QUICK SPLIT
Set 1 2 3 4 5 6 7 8 9 10
Q S ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
RA RF ATTENUATOR
Set 1 2 3 4 5 6 7 8 9 10
R A P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
R A P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
R A P1 P2 ;
P1 0:Fixed
P2 0: OFF
1: 6 dB
2: 12 dB
3: 18 dB
RC CLAR CLEAR
Set 1 2 3 4 5 6 7 8 9 10
R C ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
RD CLAR DOWN
Set 1 2 3 4 5 6 7 8 9 10
R D P1 P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 0000 - 9999 (Hz)
RF ROOFING FILTER
Set 1 2 3 4 5 6 7 8 9 10
R F P1 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
R F P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
R F P1 P3 ;
P1 0: Fixed P2 0: AUTO P3 1: 15 kHz
1: 15 kHz 2: 6 kHz
2: 6 kHz 3: 3 kHz
3: 3 kHz 4: AUTO - 15 kHz
5: AUTO - 6 kHz
6: AUTO - 3 kHz
RG RF GAIN
Set 1 2 3 4 5 6 7 8 9 10
R G P1 P2 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
R G P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
R G P1 P2 P2 P2 ;
P1 0: Fixed
P2 000 - 255
QI QMB STORE
Set 1 2 3 4 5 6 7 8 9 10
Q I ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
QR QMB RECALL
Set 1 2 3 4 5 6 7 8 9 10
Q R ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
PS POWER SWITCH
Set 1 2 3 4 5 6 7 8 9 10
P S P1 ;
Read 1 2 3 4 5 6 7 8 9 10
P S ;
Answer 1 2 3 4 5 6 7 8 9 10
P S P1 ;
P1 0: POWER “OFF”
1: POWER “ON”
This command requires dummy data be initially sent. Then after one second and
before two seconds the command is sent.

FTDX1200 CAT Operation Manual15
CAT (CompuTer Aided TrAnsCeiver)operATion
RT CLAR
Set 1 2 3 4 5 6 7 8 9 10
R T P1 ;
Read 1 2 3 4 5 6 7 8 9 10
R T ;
Answer 1 2 3 4 5 6 7 8 9 10
R T P1 ;
P1 0:RXClarier“OFF”
1:RXClarier“ON”
RU RX CLARIFIER PLUS OFFSET
Set 1 2 3 4 5 6 7 8 9 10
R U P1 P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
P1 0000 - 9999 (Hz)
SC SCAN
Set 1 2 3 4 5 6 7 8 9 10
S C P1 ;
Read 1 2 3 4 5 6 7 8 9 10
S C ;
Answer 1 2 3 4 5 6 7 8 9 10
S C P1 ;
P1 0: Scan “OFF”
1: Scan “ON” (UP ward)
2: Scan “ON” (DOWN ward)
RO ROTATOR
Set 1 2 3 4 5 6 7 8 9 10
R O P1 ;
Read 1 2 3 4 5 6 7 8 9 10
R O ;
Answer 1 2 3 4 5 6 7 8 9 10
R O P1 P2 P2 P2 P3 P3 P3 ;
P1 0: OFF (Rotation stop)
1: Counter Clockwise (Rotation start)
2: Clockwise (Rotation start)
3: SPEED 1 % DOWN
4: SPEED 1 % UP
P2 DIRECTION (0 - 450)
P3 SPEED (0 - 100 %)
RS RADIO STATUS
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
R S ;
Answer 1 2 3 4 5 6 7 8 9 10
R S P1 ;
P1 0: NORMAL MODE
1: MENU MODE
SD CW BREAK-IN DELAY TIME
Set 1 2 3 4 5 6 7 8 9 10
S D P1 P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
S D ;
Answer 1 2 3 4 5 6 7 8 9 10
S D P1 P1 P1 P1 ;
P1 0030 - 3000 msec
RL NOISE REDUCTION LEVEL
Set 1 2 3 4 5 6 7 8 9 10
R L P1 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
R L P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
R L P1 P2 P2 ;
P1 0: Fixed
P2 01 - 15
RM READ METER
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
R M P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
R M P1 P2 P2 P2 ;
P1 0:
Depends on the front panel METER5: PO
1: S 6: SWR
2: Depends on the front panel METER7: ID
(COMP / ALC / PO / SWR / ID / VDD)
8: VDD
3: COMP
4: ALC
P2 0 - 255
RI RADIO INFORMATION
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
R I P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
R I P1 P2 ;
P1 0: Hi-SWR 8: VFO-B-RX P2 0: OFF
1:MIC-EQ 9:μ-tune 1:ON
3: REC
4: PLAY
5: VFO-A TX
6: VFO-B TX
7: VFO-A RX

FTDX1200 CAT Operation Manual16
CAT (CompuTer Aided TrAnsCeiver)operATion
SQ SQUELCLH LEVEL
Set 1 2 3 4 5 6 7 8 9 10
S Q P1 P2 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
S Q P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
S Q P1 P2 P2 P2 ;
P1 0: Fixed
P2 000 - 255
SV SWAP VFO
Set 1 2 3 4 5 6 7 8 9 10
S V ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
TS TXW
Set 1 2 3 4 5 6 7 8 9 10
T S P1 ;
Read 1 2 3 4 5 6 7 8 9 10
T S ;
Answer 1 2 3 4 5 6 7 8 9 10
T S P1 ;
P1 0: TXW “OFF”
1: TXW “ON”
SH WIDTH
Set 1 2 3 4 5 6 7 8 9 10
S H P1 P2 P2 ;
Read 1 2 3 4 5 6 7 8 9 10
S H P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
S H P1 P2 P2 ;
P1 0: Fixed
P2 00 (See Table 5)
bandwidth
SSB (Narrow)
1500 Hz
200 Hz
400 Hz
600 Hz
850 Hz
1100 Hz
1350 Hz
1500 Hz
1650 Hz
1800 Hz
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
CW (Narrow)
500 Hz
50 Hz
100 Hz
150 Hz
200 Hz
250 Hz
300 Hz
350 Hz
400 Hz
450 Hz
500 Hz
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
SSB (Wide)
2400 Hz
—
—
—
—
—
—
—
—
1800 Hz
1950 Hz
2100 Hz
2200 Hz
2300 Hz
2400 Hz
2500 Hz
2600 Hz
2700 Hz
2800 Hz
2900 Hz
3000 Hz
3200 Hz
3400 Hz
3600 Hz
3800 Hz
4000 Hz
RTTY/PSK (Wide)
2400 Hz
—
—
—
—
—
—
—
—
—
500 Hz
800 Hz
1200 Hz
1400 Hz
1700 Hz
2000 Hz
2400 Hz
—
—
—
—
—
—
—
—
—
CW (Wide)
2400 Hz
—
—
—
—
—
—
—
—
—
500 Hz
800 Hz
1200 Hz
1400 Hz
1700 Hz
2000 Hz
2400 Hz
—
—
—
—
—
—
—
—
—
RTTY/PSK (Narrow)
500 Hz
50 Hz
100 Hz
150 Hz
200 Hz
250 Hz
300 Hz
350 Hz
400 Hz
450 Hz
500 Hz
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Command
table 5
P2
00 (Default)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
SM S-METER READING
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
S M P1 ;
Answer 1 2 3 4 5 6 7 8 9 10
S M P1 P2 P2 P2 ;
P1 0: Fixed
P2 000 - 255
SF SUB-DIAL FUNCTION
Set 1 2 3 4 5 6 7 8 9 10
S F P1 ;
Read 1 2 3 4 5 6 7 8 9 10
S F ;
Answer 1 2 3 4 5 6 7 8 9 10
S F P1 ;
P1 1: MHz
2: GRP
3: MCH
4: DIAL-B
5: CLAR
6: ----
7: uTUNE

FTDX1200 CAT Operation Manual17
CAT (CompuTer Aided TrAnsCeiver)operATion
VX VOX STATUS
Set 1 2 3 4 5 6 7 8 9 10
V X P1 ;
Read 1 2 3 4 5 6 7 8 9 10
V X ;
Answer 1 2 3 4 5 6 7 8 9 10
V X P1 ;
P1 0: VOX “OFF”
1: VOX “ON”
VM VFO-A TO MEMORY CHANNEL
Set 1 2 3 4 5 6 7 8 9 10
V M ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
VS VFO SELECT
Set 1 2 3 4 5 6 7 8 9 10
V S P1 ;
Read 1 2 3 4 5 6 7 8 9 10
V S ;
Answer 1 2 3 4 5 6 7 8 9 10
V S P1 ;
P1 0: VFO-A
1: VFO-B
VG VOX GAIN
Set 1 2 3 4 5 6 7 8 9 10
V G P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
V G ;
Answer 1 2 3 4 5 6 7 8 9 10
V G P1 P1 P1 ;
P1 000 - 100
VF VRF FILTER
Set 1 2 3 4 5 6 7 8 9 10
V F P1 P2 P3 P4 ;
Read 1 2 3 4 5 6 7 8 9 10
V F P1;
Answer 1 2 3 4 5 6 7 8 9 10
V F P1 P2 P5 P5 P5 P6 ;
P1 0: Fixed P4 0 - 9
P2 0: OFF P5 000 - 255
1: ON P6 0: µ-TUNE is not connected.
2: Default set 1: µ-TUNE is connected.
P3 +: Plus Shift
-: Minus Shift
VD VOX DELAY TIME
Set 1 2 3 4 5 6 7 8 9 10
V D P1 P1 P1 P1 ;
Read 1 2 3 4 5 6 7 8 9 10
V D ;
Answer 1 2 3 4 5 6 7 8 9 10
V D P1 P1 P1 P1 ;
P1 0030 - 3000 msec (10 msec multiples)
UL PLL UNLOCK STATUS
Set 1 2 3 4 5 6 7 8 9 10
Read 1 2 3 4 5 6 7 8 9 10
U L ;
Answer 1 2 3 4 5 6 7 8 9 10
U L P1 ;
P1 0: PLL “Lock”
1: PLL “Unlock”
UP UP
Set 1 2 3 4 5 6 7 8 9 10
U P ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
TX TX SET
Set 1 2 3 4 5 6 7 8 9 10
T X P1 ;
Read 1 2 3 4 5 6 7 8 9 10
T X ;
Answer 1 2 3 4 5 6 7 8 9 10
T X P1 ;
P1 0: RADIO TX “OFF” CAT TX “OFF”
1: RADIO TX “OFF” CAT TX “ON”
2: RADIO TX “ON” CAT TX “OFF” (Answer)

FTDX1200 CAT Operation Manual18
CAT (CompuTer Aided TrAnsCeiver)operATion
XT TX CLAR
Set 1 2 3 4 5 6 7 8 9 10
X T P1 ;
Read 1 2 3 4 5 6 7 8 9 10
X T ;
Answer 1 2 3 4 5 6 7 8 9 10
X T P1 ;
P1 0: TX CLAR “OFF”
1: TX CLAR “ON”
ZI ZERO IN
Set 1 2 3 4 5 6 7 8 9 10
Z I ;
Read 1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
(CW AUTO ZERO IN Function)
:requires FFT-1 (option)

Copyright 2013
YAESU MUSEN CO., LTD.
All rights reserved
No portion of this manual
may be reproduced without
the permission of
YAESU MUSEN CO., LTD. 1310-B0
This manual suits for next models
1
Table of contents
Other Yaesu Transceiver manuals

Yaesu
Yaesu FTA-310 User manual

Yaesu
Yaesu FT-2980E User manual

Yaesu
Yaesu VX-170 User manual

Yaesu
Yaesu FT-8100R Manual

Yaesu
Yaesu FT-747GX User manual

Yaesu
Yaesu FT-5100 User manual

Yaesu
Yaesu FTA-850L User manual

Yaesu
Yaesu FT-50R Manual

Yaesu
Yaesu FT3DR User manual

Yaesu
Yaesu WIRES-X TM-400XDE User manual

Yaesu
Yaesu FTDX5000D HF - PRODUCT REVIEW 12-2010 User manual

Yaesu
Yaesu FTM-3100R Setup guide

Yaesu
Yaesu FT-897 Manual

Yaesu
Yaesu FV-107 User manual

Yaesu
Yaesu FT3DR Manual

Yaesu
Yaesu FT-60R User manual

Yaesu
Yaesu FT-991 User manual

Yaesu
Yaesu VX-3R Manual

Yaesu
Yaesu VX-8R User manual

Yaesu
Yaesu FT-901DM User manual