10 YORK INTERNATIONAL
NOTES for Electrical Data pages 34 - 39:
1. Minimum Circuit Ampacity (MCA) is based on 125% of the rated load amps for the largest motor plus 100% of the rated load amps for all other
loads included in the circuit, per N.E.C Article 430-24. If a Factory Mounted Control Transformer is provided, add the following to the system
#1 MCA values in the YCA Tables: -17, add 10 amps; -28, add 9 amps; -46, add 4 amps; -58, add 3 amps.
2. Minimum fuse size is based on 150% of the largest motor RLA plus 100% of the remaining RLAs (U.L. Standard 1995, Section 36.1). It is not
recommended in applications where brown-outs, frequent starting and stopping of the unit, and/or operation at ambient temperatures in
excess of 95°F is anticipated.
3. Maximum dual element fuse size is based on 225% maximum plus 100% of the rated load amps for all other loads included in the circuit, per
N.E.C.440-22.
4. The recommended disconnect switch is based on a minimum of 115% of the summation rated load amps of all the loads included in the circuit,
per N.E.C.440-12A1.
5. Maximum HACR is based on 225% maximum plus 100% of the rated load amps for all loads included in the circuit, per circuit, per U.L. 1995
Fig. 36.2.
6. The Incoming Wire Range is the minimum and maximum wire size that can be accommodated by unit wiring lugs. The (1), (2), (3) or (4)
indicated the number of termination points which are available per phase. Actual wire size and number of wires per phase must be
determined based on ampacity and job requirements using N.E.C. wire sizing information. The above recommendations are based on the
National Electric Code and using copper connectors only. Field wiring must also comply with local codes.
7. A ground lug is provided for each compr system to accommodate field grounding conductor per N.E.C. Article 250-54. A control circuit
grounding lug is also supplied. Incoming ground wire range is #6 - #2/0 (50 - 90 Tons) or #6 - 350 MCM (95 - 230 Tons).
ELECTRICAL DATA
DUAL COMPRESSOR POWER SUPPLY WIRING (STANDARD)
SYSTEM #1 WIRING SYSTEM #2 WIRING
MODEL MAX. MAX SIZE INCOMING COND MAX. MAX SIZE INCOMING COND
YCA MCA1DUAL ELEM DIS. CKT. BKR. WIRE RANGE6CPR CPR FAN MCA1DUAL ELEM DIS. CKT. BKR. WIRE RANGE6CPR CPR FAN
FUSE MIN.4HACR5(CU ONLY) RLA LRA FLA FUSE MIN.4HACR5(CU ONLY) RLA LRA FLA
MIN.2MAX.3TYPE EACH MIN.2MAX.3TYPE EACH
Z88EE8 -17 291 350 350 400 450 (2)#4-250MCM 207 858 16 291 350 450 400 450 (2)#4-250MCM 207 858 16
Z88EE8 -28 258 350 400 400 400 (2)#4-250MCM 180 746 16.4 258 350 400 400 400 (2)#4-250MCM 180 746 16.4
Z88EE8 -46 129 175 200 200 200 (2)#4-250MCM 90 373 8.1 129 175 200 200 200 (2)#4-250MCM 90 373 8.1
Z88EE8 -58 102 125 150 100 150 (2)#4-250MCM 72 304 5.9 102 150 150 100 150 (2)#4-250MCM 72 304 5.9
J44HE8 -17 320 400 500 400 500 (2)#4-250MCM 230 731 16 320 400 500 400 500 (2)#4-250MCM 230 731 16
J44HE8 -28 283 350 450 400 450 (2)#4-250MCM 200 636 16.4 283 350 450 400 450 (2)#4-250MCM 200 636 16.4
J44HE8 -46 142 175 225 200 225 (2)#4-250MCM 100 318 8.1 142 175 225 200 225 (2)#4-250MCM 100 318 8.1
J44HE8 -58 112 150 175 200 175 (2)#4-250MCM 80 254 5.9 112 150 175 200 175 (2)#4-250MCM 80 254 5.9
J54HE8 -17 365 450 600 400 600 (2)1/0-500MCM 266 950 16 320 400 500 400 500 (2)#4-250MCM 230 731 16
J54HE8 -28 322 400 500 400 500 (2)#4-250MCM 231 826 16.4 283 350 450 400 450 (2)#4-250MCM 200 636 16.4
J54HE8 -46 162 200 250 200 250 (2)#4-250MCM 116 413 8.1 142 175 225 200 225 (2)#4-250MCM 100 318 8.1
J54HE8 -58 127 150 200 200 200 (2)#4-250MCM 92 330 5.9 112 150 175 200 175 (2)#4-250MCM 80 254 5.9
J55HE8 -17 365 450 600 400 600 (2)1/0-500MCM 266 950 16 365 450 600 400 600 (2)#4-250MCM 266 950 16
J55HE8 -28 322 400 500 400 500 (2)#4-250MCM 231 826 16.4 322 400 500 400 500 (2)#4-250MCM 231 826 16.4
J55HE8 -46 162 200 250 200 250 (2)#4-250MCM 116 413 8.1 162 200 250 200 250 (2)#4-250MCM 116 413 8.1
J55HE8 -58 127 150 200 200 200 (2)#4-250MCM 92 330 5.9 127 150 200 200 200 (2)#4-250MCM 92 330 5.9
J65HE8 -17 424 500 700 400 700 (2)1/0-500MCM 313 1101 16 365 450 600 400 600 (2)#4-250MCM 266 950 16
J65HE8 -28 373 450 600 400 600 (2)1/0-500MCM 272 976 16.4 322 400 500 400 500 (2)#4-250MCM 231 826 16.4
J65HE8 -46 187 225 300 200 300 (2)#4-250MCM 136 488 8.1 162 200 250 200 250 (2)#4-250MCM 116 413 8.1
J65HE8 -58 148 175 250 200 250 (2)#4-250MCM 109 390 5.9 127 150 200 200 200 (2)#4-250MCM 92 330 5.9