2
General information
With multidata you have acquired one of the
most up-to-date, modern heat calculator cur-
rently available on the market.
The calculator for changeover heating/cooling
meters can be identied by the inscription “change
over” on the front of the body, the cooling meters
by the inscription “cooling”. Calculators for heat-
ing meters only don’t have any specic inscription.
Expressive symbols in the display and easy menu
navigation make readout simple.
It can be operated with one single button. The
setting of the data loggers (depending on the
type of device) is being done via the software
GMM.
The calculator is equipped with a long-life battery
made for operation during the initial verication
validity period (5 years) including a reserve of at
least another year. With a second battery you will
reach 11 years.
Initial verification
The heating energy metering part of the multi-
data is manufactured and tested according to
the new European Measuring Instrument Direc-
Technical data
Temperature range °C 1 - 150
Temperature difference range k 3 - 120
Diplay Multifunctional LCD, 8-digit, oating
Display unit MWh, kWh, GJ, MJ
Interface ow sensor Models with contact pulsers or active pulser
(
No Namur or Opto, Passive max 1hz/ active max. 100Hz)
Temperature sensor connection PT500, optional PT100, PT1000
Max. cable length temperature sensor 2 wire
12.5 m (PT500), 2.5 m (PT100), 20 m (PT1000)
Max. cable length temperature sensor 4 wire
20 m
Interfaces optical, optionally ZR-Bus (RS 485), M-Bus, RS 232,
remote readout outputs
Ambient temperature °C 5 - 55
Power supply Battery 3.6 V Lithium,
optionally mains power supply 230V/24V
Battery lifetime 6 years, optionally 11 years
Protection class IP 54 / IP 65, acc. to DIN 40050
Mechanical/electro-magnetic class
M1/E1
Accuracy class according to EN1434
Measuring cycle dynamic 40s/30s/10s