MINiBOX 0-10V X3
3 fold 0-10V analog input/output multifunction module
ZIO3X010 TECHNICAL DOCUMENTATION
FEATURES
•3 connections than can be configured as 0-10V output, 0-10V input or
4-20mA input
•Manual operation of the 0-10VDC outputs
•1 fan coil module
•3 thermostats
•10 logic functions
•Total data saving on power failure
•Integrated KNX BCU
•Dimensions 67 x 90 x 36mm (2 DIN units)
•DIN rail mounting according to IEC 60715 TH35, with fixing clamp
•Conformity with the CE directives (CE-mark on the right side)
1. Multifunction inputs/outputs
2. 0-10V output status LED
3. 0-10V output control button
4. Programming/Test button
5. Programming/Test LED
6. KNX connector
7. Fixing clamp
1
5
3
4
6
2
7
Figure 1: MINiBOX 0-10V X3
Programming/Test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe
mode. If this button is held for more than 3 seconds, the device enters the test mode.
Programming/Test LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. The manual mode
is indicated by the green color. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it emits a red flash.
GENERAL SPECIFICATIONS
CONCEPT
DESCRIPTION
Type of device
Electric operation control device
KNX supply
Voltage (typical)
29VDC SELV
Voltage range
21..31VDC
Maximum
consumption
Voltage
mA
mW
29VDC (typical)
18.5
536.5
24VDC¹
25
600
Connection type
Typical TP1 bus connector for 0.80mm Ø rigid cable
External power supply
Not required
Operation temperature
0°C .. +55°C
Storage temperature
-20°C .. +55°C
Operation humidity
5 .. 95%
Storage humidity
5 .. 95%
Complementary characteristics
Class B
Protection class
III
Operation type
Continuous operation
Device action type
Type 1
Electrical stress period
Long
Degree of protection
IP20, clean environment
Installation
Independentdevice to be mounted inside electrical panelswith DIN rail (IEC
60715)
Minimum clearances
Not required
Response on KNX bus failure
Data saving according to parameterization
Response on KNX bus restart
Data recovery according to parameterization
Operation indicator
The programming LED indicates programming mode (red) and test mode
(green). Each output LED indicates its status
Weight
80g
PCB CTI index
175V
Housing material
PC FR V0 halogen free
¹ Maximum consumption in the worst-case scenario (KNX Fan-In model).
© Zennio Avance y Tecnología S.L. Edition 1 Further information www.zennio.com Page 2/2
SAFETY INSTRUCTIONSANDADDITIONAL NOTES
•Installation should only be performed by qualified professionals according to the laws and regulations applicable in each country.
•Do not connect the mains voltage nor any other external voltage to any point of the KNX bus; it would represent a risk for the entire KNX system. The
facility must have enough insulation between the mains (or auxiliary) voltage and the KNX bus or the wires of other accessories, in case of being
installed.
•Once the device is installed (in the panel or box), it must not be accessible from outside.
•Keep the device away from water (condensation over the device included) and do not cover it with clothes, paper or any other material while in use.
•The WEEE logo means that this device contains electronic parts and it must be properly disposed of by following the instructions at
https://www.zennio.com/en/legal/weee-regulation.
•This device contains software subject to specific licences. For details, please refer to http://zennio.com/licenses.
0-10V OUTPUT SPECIFICATIONS AND CONNECTIONS
CONCEPT
DESCRIPTION
Number of outputs
3
Output type
0-10VDC
Maximum load per output
2mA
Connection method
Screw terminal block
Cable cross-section
0.5-2.5mm² (IEC) / 26-12AWG (UL)
Maximum cable length
30m
Output per common
1
0-10V / 4-20mA INPUTS SPECIFICATIONS AND CONNECTIONS
CONCEPT
DESCRIPTION
Number of inputs
3
Operation voltage
0-10VDC
Operation current
4-20mA
Connection method
Screw terminal block
Cable cross-section
0.5-2.5mm² (IEC) / 26-12AWG (UL)
Maximum cable length
30m
Note: Each of the three pairs of terminals can act as an input or an output according to its parameterization.
Figure 3: Mounting MINiBOX 0-10V X3
on DIN rail
- V1/F1+ - V2/F2 +
OUTPUTS 0-10V
L / +
N / -
F1
- V3/F3 +
F2 F3
- V1/F1+ - V2/F2 +
OUTPUTS 0-10V
L / +
N / -
V1
- V3/F3 +
V2 V3
- V1/F1+ - V2/F2 +
OUTPUTS 0-10V
L / +
N / -
F1
- V3/F3 +
F2 F3
- V1/F1+ - V2/F2 +
OUTPUTS 0-10V
L / +
N / -
V1
- V3/F3 +
V2 V3
WIRING DIAGRAMS
Figure 2: Wiring examples
- V1/F1+ - V2/F2 +
INPUTS 0-10V / 4-20mA
- V3/F3 +
S1 S2 S3
Attaching MINiBOX 0-10V X3 to DIN rail:
Removing MINiBOX 0-10V X3 from DIN rail:

Other manuals for MINiBOX 0-10V X3

2

This manual suits for next models

1

Other Zennio Control Unit manuals

Zennio Analog User manual

Zennio

Zennio Analog User manual

Zennio GetFace IP User manual

Zennio

Zennio GetFace IP User manual

Zennio ZVPCB1MB User manual

Zennio

Zennio ZVPCB1MB User manual

Zennio KLIC-DI User manual

Zennio

Zennio KLIC-DI User manual

Zennio MAXinBOX FC Guide

Zennio

Zennio MAXinBOX FC Guide

Zennio ZVP-CB2M User manual

Zennio

Zennio ZVP-CB2M User manual

Zennio GetFace IP ZVP-CB3M User manual

Zennio

Zennio GetFace IP ZVP-CB3M User manual

Popular Control Unit manuals by other brands

LINK LABS LL-RLP-20 manual

LINK LABS

LINK LABS LL-RLP-20 manual

Bardiani B935 Use and maintenance manual

Bardiani

Bardiani B935 Use and maintenance manual

DF ROBOT SEN0521 user manual

DF ROBOT

DF ROBOT SEN0521 user manual

Sony HSCU300RF Service manual

Sony

Sony HSCU300RF Service manual

Honeywell HS10S installation instructions

Honeywell

Honeywell HS10S installation instructions

VAT 150 Series Installation, operating,  & maintenance instructions

VAT

VAT 150 Series Installation, operating, & maintenance instructions

Graco Therm-O-Flow 25C994 instructions

Graco

Graco Therm-O-Flow 25C994 instructions

Parallax 28560 manual

Parallax

Parallax 28560 manual

Stübbe C 10 Series operating manual

Stübbe

Stübbe C 10 Series operating manual

Tyco DV-5A manual

Tyco

Tyco DV-5A manual

GE IC695ETM001 manual

GE

GE IC695ETM001 manual

ATEQ G6 Series manual

ATEQ

ATEQ G6 Series manual

Elkron MP 200 Installation and maintenance manual

Elkron

Elkron MP 200 Installation and maintenance manual

CAMBRIONIX ModIT-Boss user manual

CAMBRIONIX

CAMBRIONIX ModIT-Boss user manual

Eclipse 200 LT Series instruction manual

Eclipse

Eclipse 200 LT Series instruction manual

Grundfos ALPHA 15-55 SUC HWR-D Comfort Installation and operating instructions

Grundfos

Grundfos ALPHA 15-55 SUC HWR-D Comfort Installation and operating instructions

Kitz SGE Operation manual

Kitz

Kitz SGE Operation manual

CREVIS GT-5352 user manual

CREVIS

CREVIS GT-5352 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.