360 Vision PRED-3M Instruction sheet

Predator Installation Manual Ver 2.9 Page 1
© 360 Vision Technology Ltd.
Predator
Installation/Conguration Manual

Predator Installation Manual Ver 2.9 Page 2
© 360 Vision Technology Ltd.
Table of Contents
1 Safety and Precautions .............................................................................................................................. 3
2 Housing Dimensional Drawing ................................................................................................................... 3
3 Bracket Dimensional Drawing .................................................................................................................... 7
4 Connections ............................................................................................................................................... 9
4.1 Standalone Alarmcard Setup ........................................................................................................... 12
4.2 Washer Control PCB Setup.............................................................................................................. 14
4.3 RS422/RS485 Converter ................................................................................................................. 15
5 Predator Washer/Nozzle Bracket ............................................................................................................. 17
6 Connections to Predators with HMA......................................................................................................... 18
7 Basic Twisted Pair/RS485 Data Wiring .................................................................................................... 19
8 Predator Protocol/Address setup. ............................................................................................................ 19
9 Predator OSD .......................................................................................................................................... 20
9.1 PIN Number ..................................................................................................................................... 20
10 OSD Operation/Navigation..................................................................................................................... 21
11 Special Presets....................................................................................................................................... 25
12 Important - Care of Painted Surfaces..................................................................................................... 26
13 Storage and Handling............................................................................................................................. 26
14 Warranty................................................................................................................................................. 26
15 Camera Specication ............................................................................................................................. 27
16 PSU Enclosure....................................................................................................................................... 27

Predator Installation Manual Ver 2.9 Page 3
© 360 Vision Technology Ltd.
1 Safety and Precautions
1. Please read these notes before attempting to operate the 360 Vision Predator, and keep for future reference.
2. DO NOT disassemble or remove covers. This will break the water seals and invalidate the warranty.
3. All servicing and repairs must be handled by 360 Vision Technology.
4. Avoid pointing the camera directly towards a bright light source (sunlight), or expose the camera to intensive
light situations as this may damage the camera pick-up device.
5. Installation should be carried out by suitably qualied personnel, in accordance with local codes of practice
and regulations.
6. 360 Vision Technology Limited accept no liability for any damage caused by incorrect or improper installation.
7. To prevent risk of injury caused by the Predator or mounting options becoming detached, t a suitable safety
chain or lanyard.
8. Connection of data signals and power should only be made using a pre-made Predator Composite cables.
9. Use only 360 Vision Predator power supplies. These have suitable terminals for all the wires in the Predator
composite cable.
10. Please handle the Predator with care, as improper handling may cause damage within this unit.
2 Housing Dimensional Drawing
Predator No Lamps
Weight 7.5kg

Predator Installation Manual Ver 2.9 Page 4
© 360 Vision Technology Ltd.
Weight 8kg
Predator Single Lamps - Covers IR75, IR125 or IR100WL versions.
Predator Dual Lamps - Covers IR175 or IR150SW versions.
Weight 8.5kg
MUST NOT BE REPRODUCED OR SHOWN TO
DO NOT SCALE
ALL DIMENSIONS IN MM
REMOVE ALL SHARP EDGES
SHEET:
D
C
B
A
D
C
B
A
4
3
2
1
4
3
2
1
A3
DESCRIPTION SCALE:
PERMISSION OF THE AUTHOR.
ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN
C COPYRIGHT PROTECTED AND
THIS DRAWING AND ALL COPIES ARE
PART NUMBER:
0.300 1 OF 2
TOLERANCES:-
X = 0.5
X.X = 0.1
X.XX = 0.05
A3
3rd ANGLE PROJECTION
360 Vision Technology Ltd.
Unit 7, Seymour Court,
Manor Park, Runcorn, Cheshire,
WA7 1SY. United Kingdom.
www.360visiontechnology.com
11
422
270
TILT
SWEEP
125
MOUNTING BASE
9 (x4) ON
101.6 (4 INCH) PCD
380
253 420 PAN SWEEP
NAME:
M5701-A
PREDATOR ASSEMBLY
SINGLE LAMP - ALUMINIUM
ISS DATE REFERENCE
A 060616 FIRST ISSUE
060616
DATE :
K.CRAIK
RELEASED:
APPROVED:
ENGINEER:
--
MATERIAL: FINISH:
SINGLE IR LIGHTS
SCALE 0.3
MOUNTING
BASE
SCALE 0.3
MUST NOT BE REPRODUCED OR SHOWN TO
DO NOT SCALE
ALL DIMENSIONS IN MM
REMOVE ALL SHARP EDGES
SHEET:
D
C
B
A
D
C
B
A
4
3
2
1
4
3
2
1
A3
DESCRIPTION SCALE:
PERMISSION OF THE AUTHOR.
ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN
C COPYRIGHT PROTECTED AND
THIS DRAWING AND ALL COPIES ARE
PART NUMBER:
0.300 1 OF 2
TOLERANCES:-
X = 0.5
X.X = 0.1
X.XX = 0.05
A3
3rd ANGLE PROJECTION
360 Vision Technology Ltd.
Unit 7, Seymour Court,
Manor Park, Runcorn, Cheshire,
WA7 1SY. United Kingdom.
www.360visiontechnology.com
11
422
270
TILT
SWEEP
125
MOUNTING BASE
9 (x4) ON
101.6 (4 INCH) PCD
380
253 420 PAN SWEEP
NAME:
M5702-A
PREDATOR ASSEMBLY
DUAL LAMP - ALUMINIUM
ISS DATE REFERENCE
A 160616 FIRST ISSUE
160616
DATE :
K.CRAIK
RELEASED:
APPROVED:
ENGINEER:
--
MATERIAL: FINISH:
DUAL IR LIGHTS
SCALE 0.3
MOUNTING
BASE
SCALE 0.3

Predator Installation Manual Ver 2.9 Page 5
© 360 Vision Technology Ltd.
Weight 8kg
Predator Thermal with Lamps - Covers IR (75m IR) or IRW (75m IR, 50m White Light) versions.
Weight 9kg
Predator Single Lamps (Straight Arm version) - Covers IR75, IR125 or IR100WL versions.

Predator Installation Manual Ver 2.9 Page 6
© 360 Vision Technology Ltd.
Predator Thermal No Lamps
Weight 9.5kg
HMA Predator No Lamps (shown)
All version of the Predator can be built to order with the integral HMA (Hinged Mount Adapter). The HMA is tted
during manufacture and is NOT available as an option for the installer to add to an existing Predator.
Weight 9kg

Predator Installation Manual Ver 2.9 Page 7
© 360 Vision Technology Ltd.
3 Bracket Dimensional Drawing
Weight 1.2kg
Predator Wall Bracket
Weight 2.2kg
Predator Corner Bracket
Weight 2.5kg
Predator PMB Bracket

Predator Installation Manual Ver 2.9 Page 8
© 360 Vision Technology Ltd.
Predator PMA Bracket
Please use the appropriate xings to suit the weight of the camera housing used.
Weight 1kg
MUST NOT BE REPRODUCED OR SHOWN TO
DO NOT SCALE
ALL DIMENSIONS IN MM
REMOVE ALL SHARP EDGES
SHEET:
D
C
B
A
D
C
B
A
4
3
2
1
4
3
2
1
A3
DESCRIPTION SCALE:
PERMISSION OF THE AUTHOR.
ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN
C COPYRIGHT PROTECTED AND
THIS DRAWING AND ALL COPIES ARE
PART NUMBER:
0.125 9 OF 9
TOLERANCES:-
X = 0.5
X.X = 0.1
X.XX = 0.05
A3
3rd ANGLE PROJECTION
360 Vision Technology Ltd.
Unit 7, Seymour Court,
Manor Park, Runcorn, Cheshire,
WA7 1SY. United Kingdom.
www.360visiontechnology.com
125
OUTSIDE
DIAMETER
9 (x4) ON
101.6 (4 INCH) PCD
USE M8 BOLT FOR
FIXING TO POLE
60
M8 (x4) ON 101.6
(4 INCH) PCD.
FIX PREDATOR USING:
M8x30 HEX-HEAD BOLTS (x4)
- STAINLESS STEEL.
M8 SPRING LOCK WASHER (x4)
- STAINLESS STEEL.
73
M20x1.5P
M20x1.5P
73
M20x1.5P
8.0 (x4) ON 101.6
(4 INCH) PCD.
FIX PREDATOR USING:
M8x30 HEX-HEAD BOLTS (x4)
- STAINLESS STEEL.
M8 SPRING LOCK WASHER (x4)
- STAINLESS STEEL.
53.0
125
OUTSIDE
DIAMETER
M20x1.5P
10 (x4) ON
101.6 (4 INCH) PCD
USE M8 BOLT FOR
FIXING TO POLE
NAME:
M5350-A
PREDATOR ASSEMBLY
STAINLESS STEEL
ISS DATE REFERENCE
A 290216 FIRST ISSUE
290216
DATE :
K.CRAIK
RELEASED:
APPROVED:
ENGINEER:
--
MATERIAL: FINISH:
MOUNT PREDATOR
TO THIS FACE.
MOUNT POLE
TO THIS FACE.
MOUNT PREDATOR
TO THIS FACE.
MOUNT POLE
TO THIS FACE.
MATERIAL:
STAINLESS STEEL
MASS = 3.6 Kg PMA = STAINLESS STEEL
SCALE 0.5
SCALE 0.5
PMA = ALUMINIUM
MATERIAL:
ALUMINIUM
MASS = 0.93Kg
SCALE 0.5 SCALE 0.5

Predator Installation Manual Ver 2.9 Page 9
© 360 Vision Technology Ltd.
4 Connections
Predator Composite Cable
This pre-made Predator Composite Cable is available in 3m, 10m, 25m and 40m lengths. It contains video
coax, power and data cables. One end is tted with the IP68 12-way connector for direct connection to
the Predator, the other is supplied with all cables stripped and tined ready to be connected to the two-part
connectors which are supplied with the Predator power supply.
Connecting the composite cable to the Predator
Route the cable through the brackets and cable glands before connecting it to the Predator. Ensure that the
pins and sockets are lined up correctly, insert the connector and tighten the locking ring to make the connector
water tight.
It is important that the water should not be allowed to pool around the connector, as this will increase the risk of
contamination and corrosion which may cause poor connections.
The connector on the base of the Predator is rated IP68, when it is correctly connected and the locking ring is
tight.
Predator 12-way connector pin-out.
White Band Predator Cable (PRED) Yellow Band Predator Cable (PREDTH)
Cables for Connection to Predator Power Supply
PRED-3M Pre-made 3m cable PREDTH-3M Pre-made 3m cable
PRED-10M Pre-made 10m cable PREDTH-10M Pre-made 10m cable
PRED-25M Pre-made 25m cable PREDTH-25M Pre-made 25m cable
PRED-40M Pre-made 40m cable PREDTH-40M Pre-made 40m cable
Optical Camera Optical Camera with Thermal Camera
Cables for Connection from Predator Power Supply
Cable Type
3 x 0.75mm² conductors with PVC insulation,
PVC overall sheath (H03VV-F or H05RN-F) 250m
Maximum Distance
Mains
Video
Belden 9841, Belden 9842, Belden 8723 3000m
Twisted Pair Data
(RS485)
RG59BU (Copper central conductor, RG11, CT125) 1000m
RG59BU (low quality cable conductor) 250m
Socket 12-pin socket (solder side view)
fitted by 360 Vision to the composite cable
Coax Screen (B)
Grey (C)
White (D)
Blue (E)
Violet (F)
Pink (G)
Green (H)
Orange (J)
Red (K)
Black (M)
Brown (L)
Coax Core (A)
A
B
L C
D
E
F
G
MH
K
J
Socket 12-pins: Wiring diagram of socket fitted
by 360 Vision to the composite cable
Coax Screen (B)
Grey (C)
White (D)
Coax Core (E)
Coax Screen (F)
Pink (G)
Green (H)
Orange (J)
Red (K)
Black (M)
Brown (L)
Coax Core (A)
A
B
L C
D
E
F
G
MH
K
J
White Coax
Black Coax

Predator Installation Manual Ver 2.9 Page 10
© 360 Vision Technology Ltd.
MAINS FUSE
PRED-PSU-SM
MAINS FUSE 3 = 2AF
OUTPUT FUSE
PRED-PSU-SM
FUSE 1 = 6.3AT
FUSE 2 = 1AT
FUSE 4 = N/A
MAINS input
100 - 240Vac
Io Vo
Adj Adj
Model Number: PRED-PSU-SM
Serial Number: yymmndd-xxxx
Input Voltage:100-240VAC 50/60Hz
Input current 2.1A
Output Voltage: 30V DC
Output Current: 6.2A
Use pre-made cable PRED-3M,
PRED-10m, PRED-25m or PRED-
40m to connect to Predator.
NOTE -All wires in composite
cable must
be connected.
PRED-PSU-SM
255 x 180 x 100mm
Enclosure Dimensions
Analogue Version Wiring
24Vac(+)PINK
24Vac(-)GREEN
24Vac(+)GREY
24Vac(-)WHITE
24Vac(+)BROWN
24Vac(-)BLACK
Coax Core
Coax Screen
RED
ORANGE
RS485 D+
RS485 D-
Coax Core (TC)
Coax Screen (TC)
To Analogue
Controller

Predator Installation Manual Ver 2.9 Page 11
© 360 Vision Technology Ltd.
MAINS FUSE
PRED-XALARM-PSU-SM-A
MAINS FUSE 3 = 2AF
OUTPUT FUSE
PRED-XALARM-PSU-SM-A
FUSE 1 = 6.3AT
FUSE 2 = 1AT
FUSE 4 = N/A
MAINS input
100 - 240Vac
Io Vo
Adj Adj
Model Number: PRED-XALARM-PSU-SM-A
Serial Number: yymmndd-xxxx
Input Voltage:100-240VAC 50/60Hz
Input current 2.1A
Output Voltage: 30V DC
Output Current: 6.2A
ALARM INPUTS
CON1
(e.g. Connect A1 to COM
to activate Alarm 1)
ALARM RELAY OUTPUT
CON3 (Volts Free)
0.5A 125Vac max.
1A 24Vdc max
PRED-XALARM-PSU-SM-A
Use pre-made cable PRED-3M,
PRED-10m, PRED-25m or
PRED-40m to connect to
Predator.
NOTE - All wires in
composite cable must
be connected.
255 x 180 x 100mm
Enclosure Dimensions
24Vac(+)PINK
24Vac(-)GREEN
24Vac(+)GREY
24Vac(-)WHITE
24Vac(+)BROWN
24Vac(-)BLACK
Coax Core
Coax Screen
RED
ORANGE
RS485 D+
RS485 D-
Coax Core (TC)
Coax Screen (TC)
To Analogue
Controller

Predator Installation Manual Ver 2.9 Page 12
© 360 Vision Technology Ltd.
The PRED-XALARM-PSU has eight normally open/normally closed (Dilswitch S1, switch 8 on) alarm inputs
on connector CON1 on the alarm PCB. When using normally closed contacts, all un-used alarm inputs must
be connected to alarm in common CON1. Connect switches or volts free relay outputs from PIRs or other
equipment to CON1 connector so that the terminal labelled COM is connected to the appropriate alarm input
(A1 to A8) when the alarm contact is activated. There is also an alarm relay which can be used to activate
alarms on other equipment (DVRs etc.). The alarm relay contacts (Common – ‘C’, Normally Open – ‘NO’ and
Normally Closed – ‘NC’) use connector CON3 on the alarm PCB.
When an alarm is activated, the ALARM PCB will activate the alarm relay output and will send commands to set
the Predator to activate ‘alarm mode’. The Predator will save the current status (pan, tilt, lens, tour and mimic)
then it will seek the preset which corresponds with the active alarm number.
The alarm will remain active while the alarm input is active. After the alarm input becomes inactive, a 10 second
alarm timer will start. The timer extends the alarm activity until the alarm timer expires. If the alarm input
becomes active again before the timer has expired, the timer resets and will restart again when the alarm input
becomes inactive and a further preset seek command is sent to the Predator.
If an alarm is active and a further alarm becomes active, the latest alarm will interrupt the previous alarm. (i.e.
the latest alarm has highest priority) The Predator will seek the preset that corresponds with the new alarm.
When the contacts become inactive, the Predator will seek the preset that corresponds with the previous
highest priority alarm that is still active. When all alarms inputs are inactive the alarm timer starts. After the timer
expires, the Alarm PCB sends a command to the Predator to end the ‘alarm mode’ and the Predator will return
to the status position and action that had been saved when rst alarm became active. (Fit a link on the alarm
card CON4 position 7 to disable the automatic return to the pre-alarm status when all alarms and the alarm time
have expired).
When an alarm is active and the Predator has automatically selected the appropriate preset, it is possible to
send further commands (i.e. manual control) to the Predator which will override the preset which had previously
been automatically selected. Each time an automatic preset seek occurs as described in the previous
paragraph; the manual control will be interrupted.
4.1 Standalone Alarmcard Setup
Alarm Number Preset Number
1 1
2 2
3 3
4 4
Alarm Number Preset Number
5 5
6 6
7 7
8 8
Address (1-7) (Range 1 to 128)
Use Dilswitch to set address same as camera.
(see page 13).
Alarm Input setting
Use Dilswitch pole 8 to set if alarms are N/O or N/C. All
unused N/C contacts to be connected to alarm common.
(see page 13).
RS485 In Connections/LK3 termination
Connect RS485 from controller to CON6.
Power Connections
Connect 24Vac to CON7.
RS485 Out Connections/LK1 termination
Connect RS485 to camera to CON5.
Relay Output
Use CON3 for relay output.
Alarm Inputs
Use CON1 for volt free alarm inputs.
Protocol/Alarm settings
Use CON4 to set protocol and camera
alarm behaviour. (see page 14).

Predator Installation Manual Ver 2.9 Page 13
© 360 Vision Technology Ltd.
Dil Switch Settings 1-7
Address 1 to 128 range See below
Dil Switch Settings 8
Normally Open Contacts O
Normally Closed Contacts (un-used inputs must be connected to common) On
RS485 Address Settings
1 2 3 4 5 6 7 8
ON
Example shows switch
settings for camera address 3
Switch is shown as
white.
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON

Predator Installation Manual Ver 2.9 Page 14
© 360 Vision Technology Ltd.
1 2 3 4 5 6 7 8
CON4
Protocol Settings 3 4 5 6
360 Vision O O O O
Pelco D 9600 baud On O O O
Pelco D 4800 baud O On O O
Pelco D 2400 baud On On O O
Pelco P 9600 baud O O On O
Pelco P 4800 baud On O On O
Pelco P 2400 baud O On On O
Alarm Settings 7 8
Normal Operation O O
No Pre-alarm, No White Light On O
Forced White Light O On
No Pre-alarm, White Light Timer On On
CON4 Settings
4.2 Washer Control PCB Setup
Power supplies ordered with a Washer function are shipped pre-built into the PSU weather proof box. The
washer control unit is programmed at manufacture to suit the protocol required and cannot be changed. No
further connections are required to this PCB during installation, but address must be set to suit.
Aux Settings 1
Aux 2 (Pelco default) O
Aux 3 (Pelco D 2400 only) On
1 2 3 4 5 6 7 8
CON4
Address (1-7) (Range 1 to 128)
Use Dilswitch to set address same as camera.
(see page 13)
Relay Output
Pre-wired CON3 for relay output to washer power PCB.
RS485 In Connections/LK3 termination
Connect RS485 from controller to CON5.
RS485 Out Connections
Pre-wired RS485 to camera from CON6.
Power Connections
Pre-wired 24Vac to CON7.
Inputs
CON1 not used.

Predator Installation Manual Ver 2.9 Page 15
© 360 Vision Technology Ltd.
4.3 RS422/RS485 Converter
RS422 Tx/Termination LK2
Use CON4 for RS422 Tx
RS422 Rx/Termination LK1
Use CON2 for RS422 Rx
RS485
Pre-wired CON3 for RS485
to camera.
Power
Pre-wired CON1 for 24Vac
power connection.

Predator Installation Manual Ver 2.9 Page 16
© 360 Vision Technology Ltd.
MAINS FUSE
PRED-PSU-SM-WA-A
MAINS FUSE 3 = 2AF
OUTPUT FUSE
PRED-PSU-SM-WA-A
FUSE 1 = 6.3AT
FUSE 2 = 1AT
FUSE 4 = 1AT
MAINS input
100 - 240Vac
Io Vo
Adj Adj
Model Number: PRED-PSU-SM-WA-A
Serial Number: yymmndd-xxxx
Input Voltage:100-240VAC 50/60Hz
Input current 2.1A
Output Voltage: 30V DC
Output Current: 6.2A
PRED-PSU-SM-WA-A
Coax Core
Coax Screen
RED
ORANGE
RS485 D+
RS485 D-
Use pre-made cable PRED-3M,
PRED-10m, PRED-25m or
PRED-40m to connect to
Predator.
NOTE - All wires in
composite cable must
be connected.
255 x 180 x 100mm
Enclosure Dimensions
Coax Core (TC)
Coax Screen (TC)
24Vac(+)PINK
24Vac(-)GREEN
24Vac(+)GREY
24Vac(-)WHITE
24Vac(+)BROWN
24Vac(-)BLACK
To Analogue
Controller

Predator Installation Manual Ver 2.9 Page 17
© 360 Vision Technology Ltd.
5 Predator Washer/Nozzle Bracket
Nozzle bracket.
The predator washer bracket kit includes the bracket, nozzle M8 plain metal washer, M8 lock washer and four
cable ties.
Nozzle Adjustment
The nozzle is set to produce a vertical water jet. The direction of the jet can be adjusted by rotating the nozzle
body in the bracket, or by using the screw-driver slot.
Fixing Bracket to Predator
Choose one of the four M8 predator xing bolt positions to be used to mount the nozzle bracket so that it does
not obscure an important view. E.g. directly above the horizontal bar of a wall bracket would be suitable.
Fit an m8 at metal washer between the predator base and the nozzle bracket so that the base of the bracket is
not crooked. Fit an M8 lock washer under the head of the bolt to reduce the risk of the bolt becoming loose and
the bracket moving. Ensure that the curved end of the bracket xing plate is directed towards the Predator pan
shaft so that the vertical part of the bracket is the maximum distance from the rotating body.
Tube Connection
Suitable tube (not supplied) for connection to the nozzle is PVC with internal diameter 3mm and outside
diameter 6mm PVC.
The end of the tube is pushed over the ridged tube at the rear of the nozzle. Fit a cable tie around the joint
between the PVC tube and the rear of the nozzle to ensure that the tube can not become detached.
The PVC tube should weave through the two slots in the bracket to provide strain relief. Cable ties can be used
to secure the tube so that it is clear of the Predator’s rotating body. Take care that the cable ties do not cause
excessive restriction of the tube.
K.Craik
15-08-2016
Predator washer image
Water Jet direction (vertical)
Adjustable Nozzle
Tie
Tube
Nozzle Bracket located
Fit M8 Plain Washer Between Nozzle
Bracket and Predator Mounting Base.

Predator Installation Manual Ver 2.9 Page 18
© 360 Vision Technology Ltd.
6 Connections to Predators with HMA
When the HMA (Hinged Mount Adaptor) is tted to the Predator, the ‘Predator Composite Cable’ is not used.
Connections between the power supply and Predator use conventional cables as detailed below.
24Vac Power connections between Predator PSU and Predator that is tted with HMA
Cable Size No IR IR80 IR110WL IR130 IR175SW IR200
0.75mm² 20m 10m 7.5m 7.5m 6m N/A
1.00mm² 25m 12.5m 10m 10m 8m N/A
1.25mm² 30m 15m 12.5m 12.5m 10m N/A
1.50mm² 40m 20m 15m 15m 12m 4m
2.50mm² 65m 30m 25m 25m 20m 6.5m
3.00mm² 80m 40m 30m 30m 24m 8m
4.00mm² 100m 50m 40m 40m 32m 10.5m
If a thermal camera is tted in the Predator use a coax to connect the video signal BNC from Predator that is
tted with HMA and Predator PSU (PCB-000-0157-xx) CON6. This is used for the thermal camera video.
Gain access to connectors in the HMA
• Ensure that the xed part of the HMA is securely bolted to the top of the pole.
• The hinged part of the HMA (Hinged Mount Adapter) is fastened to the xed part using three M8x25
long hex head bolts. Use a spanner (13mm) to remove the three bolts. Each bolt is tted with a
split spring lock washer, a plain metal washer (which prevents the split washer from damaging the
bre washer) and a bre washer (which prevents the paint on the hinged part from being damaged
unnecessarily.
• Open the hinge taking care that the gasket is not damaged and support the weight of the Predator.
Gently open the HMA until the lanyard is able to take the weight. If the lanyard appears to support the
weight of the Predator, there is no need to continue to support the Predator. The connection circuit
board (PCB-000-0221-01) can now be seen.
Please make sure there is adequate spare cable (20cm) for when the camera is resting on the lanyard, failure
to do this could damage the connector circuit board.
Camera
Use BNC Video 1 for video connection from Predator.
Power Connections
Connect 24Vac to CON5.
RS485 Connections
Connect RS485/Twisted Pair data cable to CON2.
Thermal Camera (If present)
Use BNC Video 2 for thermal video connection from
Predator.

Predator Installation Manual Ver 2.9 Page 19
© 360 Vision Technology Ltd.
7 Basic Twisted Pair/RS485 Data Wiring
The Predator is capable of being controlled by either Coax Telemetry or Twisted Pair Telemetry (RS485). Below
are wiring congurations for two wiring formats used for Twisted Pair Telemetry (RS485). The Predator camera
cannot be wired in a Daisy Chain conguration as the RS485/twisted pair circuit is terminated/end of line.
Daisy Chain (Cannot be used with the 360 Predator)
RS485 twisted pair cable is wired to each camera in a “chain”. Only the
last camera is to have the RS485 (end of line) termination on, all other
cameras in the chain must have the RS485 termination o.
Star Wired
RS485 twisted pair cable is wired to each camera in a “star” from one
point. A suitable RS485 star driver/data distribution product must be
used. All cameras in this wiring conguration must have the RS485
(end of line) termination on.
8 Predator Protocol/Address setup.
All Predator cameras are supplied set to 360 Vision protocol, camera twisted pair address 1. When the Predator
is switched on, an OSD (On Screen Display) is shown on the image from the camera for approx 20 seconds.
PRO:360VTL CAM:0001 DS
Predator Software Version
PRO: Protocol being used for telemetry (e.g. 360 Vision Technology Ltd)
CAM: Camera RS485 ID (e.g. Cam 1)
D: If present dual addressing is enabled on the camera.
S or L: Short or Long cable run. Use the utility to set wether the coax used to send video is under or over 300m.
Second Line: Shows the Predator Software Version loaded into the camera.
To change the above settings in the camera, 360 Predator utility software, a USB/RS485 cable (PRED-
USB-485) and a laptop are required.
The Predator utility and PRED-USB-485 cable drivers can be found on the CD (shipped with the camera) or
contact 360 Vision Technical Support.
Install the software (Predator-issued-120521-1-installer.exe) on the laptop being used. Connect the RS485 end
of the cable tted with a 3 way connector to the Predator PSU 3 way RS485 port. Run the utility on the laptop
and then connect the USB end of the cable into the laptop. The utility will then look for new comms ports and
then will look for the camera across all baud rates used.
Settings that can be altered from this software are:
• Protocol: 360 (Coax/RS485), Pelco P 2400/4800/9600, Pelco
D 2400/4800/9600, Pelco Coaxitron (Extended version), VCL
(Coax/RS485), Ultrak (RS485), Forward Vision (RS485),
Molynx (Coax/RS485)*
• Coax Cable length: Longer than 300m or shorter than 300m.
• RS485 Address: Used on RS485 systems only.
*Molynx Coax is only available when the camera is ordered with
this requirement.

Predator Installation Manual Ver 2.9 Page 20
9 Predator OSD
OSD (On Screen Display) is accessed by dening/programming preset 6 or 95.
• Use the joystick up, down, left and right to navigate the menu.
• Use the joystick zoom in to highlight/select an option.
• Use joystick left and right to increment/decrement numbers.
Tour 001 item ...
PreDelSpd
Old.................
New................
0 1 2 3 4 5 6 7 8 9
Accept Item
Accept Final Item
Clear item
Return
Exit
DEFINE MIMIC
Mimic Number 001
Start Recording
Return
Exit
DEFINE PRESET
Preset Number ...
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return
Exit
DEFINE HOME FUNCTION
Action Tour
Number 001
Delay Minutes 010
Delay Seconds 000
Accept Changes
Return
PRIVACY ZONE MENU
Dene Privacy Zone
Seek Privacy Zone
Remove Privacy Zone
Return
Exit
SERVICING
Power Reset Dome
Factory Reset Dome
Predator Software Version
Return
Exit
Dene Tour
Dene Mimic
Dene Preset
Dene Home Function
Return
Dene Tour
Dene Mimic
Dene Preset
Dene Home Function
Settings Menu
Text Field Menu
Servicing
Privacy Zone Menu
Preset Mapping
Return
SEEK PRESET
Preset Number ...
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return
Exit
START TOUR
Tour Number 001
Start Tour
Return
Exit
START MIMIC
Mimic Number 001
Start Mimic
Return
Exit
DOME SETTINGS MENU
Pin Number ...
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return
Exit
DOME MENU
Seek Preset
Start Tour
Start Mimic
Dome Settings Menu
Exit
9.1 PIN Number
Operators PIN: 360 or 426 or 180
Controllers PIN: 1379 or 9731
Engineers PIN: 5498
TEXT FIELD EDIT
---------------------------------------
0123456789 :ABCDEFG
HIJKLMNOPQRSTUVWXYZ
X Position: 000
Y Position: 000
TEXT Display: OFF
Accept Entry
Clear Entry
Return
PRESET MAPPING
Presets 01 to 07
Presets 08 to 14
Presets 15 to 21
Return
General Settings
Pelco Settings
Night1 Settings
Night2 Settings
Lamps Settings
Shutter Settings
Thermal Settings
Return
WARNING
All Stored Data Will Be
Permanently Erased
Continue
Return
Exit
DEFINE PRIVACY ZONE
Privacy Zone ...
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return
Exit
SEEK PRIVACY ZONE
Privacy Zone ...
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return
Exit
REMOVE PRIVACY ZONE
Privacy Zone ...
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return
Exit
FINISH MIMIC BY
DEFINING ANY PRESET
No. ACTION SEEK
01 a) none NO
02 b) none NO
03 c) none NO
04 d) none NO
05 e) none NO
06 f) none NO
07 g) none NO
Accept Changes
Return
Controller level Engineer level
Digital Zoom ON
White Balance OUTDOOR
Line Lock ON
Line Phase +056
Video Gain 002
Video Lift 000
Wide Dynamic OFF
Sunshield OFF
Accept Changes
Return
Auto Flip SEMI
Proportional OFF
Freeze Presets ON
Zoom Speed 007
OSD Preset Six YES
Upright Mount ON
Aperture(day) 010
Attack Detect ON
Accept Changes
Return
Wiper Rest (s) 000
Wiper ON time (h) 000
Wiper ON time (m) 000
Wiper ON time (s) 000
Wiper Permanent OFF
FV Text Control OFF
AF AI When PTZ ON
Noise Reduct (day) 0
Accept Changes
Return
White Lamps YES
White When Alarm ON
White Timeout ON
White Timeout (m) 001
Auto Dimming YES
FV White Lights a)YES
Power on Park YES
White Exclusion YES
Accept Changes
Return
Low Light Angle 000
Low Light Value 100%
Accept Changes
Return
Preset Dene ON
Pelco D Response NO
Ultrak Cmd T/out ON
Arms CANTED
Accept Changes
Return
Aux1 a) auto focus
Aux2 b) digital zoom
Aux3 c) auto iris
Aux4 d) ir
Aux5 e) wiper
Aux6 f) washer
Aux7 g) osd
Aux8 h) backlight
Accept Changes
Return
Col/Mono Change: Dark
Mono On 020
Mono O 013
1=day 7=dusk 20=dark
Brightness Bright
Bright Control Preset
Accept Changes
Return
Illumination IR
Lamp Intensity 100%
Camera Mono
External Lighting Yes
Aperture 3
Noise Reduction 0
Low Light Focus ON
Night Presets OFF
Accept Changes
Return
Lamps1
Lamps2
Return
Fast Shutter OFF
Fast Shutter Speed
g:1/1000
Slow Shutter 1/3 sec
Accept Changes
Return
Gain mode
a: Automatic
Gain Control Mode
a: Histogram
Intensity Transform
a: White Hot
Dual Addressing OFF
Accept Changes
Return
General1 Settings
General2 Settings
General3 Settings
General4 Settings
Return
Thermal
Lamps Shutter
Night 2
Night 1
Pelco
General
General 1 General 2 General 3 General 4 Lamps 1 Lamps 2
This manual suits for next models
11
Table of contents
Other 360 Vision Security Camera manuals

360 Vision
360 Vision Predator Ultra Instruction sheet

360 Vision
360 Vision Affiniti Thermal IP Instruction sheet

360 Vision
360 Vision Invictus Hybrid Instruction sheet

360 Vision
360 Vision Visiondome-HD Instruction sheet

360 Vision
360 Vision Invictus Hybrid Manual

360 Vision
360 Vision Illuminator HD Instruction sheet

360 Vision
360 Vision Predator Radar Instruction sheet

360 Vision
360 Vision Predator-Dualview Manual

360 Vision
360 Vision Predator Ultra Instruction sheet

360 Vision
360 Vision Eclipse HD Stainless Steel Instruction sheet