PLUMBING RECOMMENDATIONS:
To prevent excess fertilizer from dribbling out of the hoses
when product application is shut o, install one push to
connect polypropylene (Inlet x Outlet) 3/8” O.D. check valve
(not included) in the plumbing to each row prior to the 360
BANDIT orifices. Check valve is available at Dultmeier Sales
(Item #BUCV1103-P38).
A 50 mesh strainer (not included) can be used in the
complete plumbing system between tanks and 360
BANDIT to help prevent debris from blocking orifices.
Install orifice plates 19 in the rubber grommets 20 .
Assemble pluming components in the arrangement shown
above 21 .
Attach the plumbing assembly to each of the hoses coming
from the house guides 22 .
NOTE: If hoses are not fully seated in the push to connect,
they will leak. Hoses seat 7/8” of an inch deep or until you
hear a snap.
The supplied push to connect adapter in the 360 BANDIT kit
connects to 3/8” push to connect compatible hose.
Secure hoses to row unit with provided zip ties.
19
20
21
22
Slide the closing system into place, ensuring the pin hole
lines up with the hole on the BANDIT unit.
Using the previously removed pin and hair clip 18 or the
provided pair of 1/2” bolts and nuts, secure the closing
system to the BANDIT unit.
Reinstall insecticide attachment, if present.
INSTALLATION INSTRUCTIONS
HARVEST INTERNATIONAL
STEP 6
REINSTALL CLOSING SYSTEM
STEP 7
ASSEMBLE PLUBING
INSTALLATION COMPLETE
PAGE 4
22
18