manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aaeon
  6. •
  7. Control Unit
  8. •
  9. Aaeon PCM-3660 Rev.B User manual

Aaeon PCM-3660 Rev.B User manual

Other Aaeon Control Unit manuals

Aaeon COM-KB User manual

Aaeon

Aaeon COM-KB User manual

Aaeon NanoCOM-KBU-A20 User manual

Aaeon

Aaeon NanoCOM-KBU-A20 User manual

Aaeon PFM-800P User manual

Aaeon

Aaeon PFM-800P User manual

Aaeon PER-C38L User manual

Aaeon

Aaeon PER-C38L User manual

Aaeon PFM-530I User manual

Aaeon

Aaeon PFM-530I User manual

Aaeon NanoCOM-U15 User manual

Aaeon

Aaeon NanoCOM-U15 User manual

Aaeon GENE-8315 User manual

Aaeon

Aaeon GENE-8315 User manual

Aaeon PFM-540I User manual

Aaeon

Aaeon PFM-540I User manual

Aaeon AQ7-BT User manual

Aaeon

Aaeon AQ7-BT User manual

Aaeon COM-KB User manual

Aaeon

Aaeon COM-KB User manual

Aaeon COM-915 A2.0 User manual

Aaeon

Aaeon COM-915 A2.0 User manual

Aaeon COM-TGUC6 User manual

Aaeon

Aaeon COM-TGUC6 User manual

Aaeon ETX - 625 User manual

Aaeon

Aaeon ETX - 625 User manual

Aaeon PICO-BSW1 User manual

Aaeon

Aaeon PICO-BSW1 User manual

Aaeon NanoCOM-APL User manual

Aaeon

Aaeon NanoCOM-APL User manual

Aaeon PER-V01B User manual

Aaeon

Aaeon PER-V01B User manual

Aaeon GENE-6350 User manual

Aaeon

Aaeon GENE-6350 User manual

Aaeon PFM-C20N User manual

Aaeon

Aaeon PFM-C20N User manual

Aaeon PER-C20L User manual

Aaeon

Aaeon PER-C20L User manual

Aaeon ETX-945GSE User manual

Aaeon

Aaeon ETX-945GSE User manual

Aaeon PCM-8152 User manual

Aaeon

Aaeon PCM-8152 User manual

Aaeon PCM-5335 User manual

Aaeon

Aaeon PCM-5335 User manual

Aaeon PER-C10L User manual

Aaeon

Aaeon PER-C10L User manual

Aaeon PCM-3536 User manual

Aaeon

Aaeon PCM-3536 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660 Rev.B Quick Installation Guide 1-1
Notice
This guide is designed for experienced users to setup the system in
the shortest time.
Safety Precautions
Always completely disconnect the power cord
from your board whenever you are working
on it. Do not make connections while the
power is on, because a sudden rush of power
can damage sensitive electronic
components.
Always ground yourself to remove any static
charge before touching the board. Modern
electronic devices are very sensitive to static
electric charges. Use a grounding wrist strap
at all times. Place all electronic components
on a static-dissipative surface or in a
static-shielded bag when they are not in the
chassis.
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660 Rev.B Quick Installation Guide 1-2
Introduction
The PCM-3660 Rev.B is a high-performance 16-bit jumperless Ethernet
interface module that attaches to the PC/104 connector on your CPU card or
PC/104 CPU module. The module automatically senses whether it is
connected to an 8-bit or 16-bit PC/104 system. The PCM-3660 Rev.B fully
complies with IEEE 802.3 10 Mbps CSMA/CD standards and is 100%
Novell NE2000 compatible.
The module includes a built-in 10BASE-T transceiver and RJ-45 connector.
Two diagnostic LEDs indicate the operating The PCM-3660 Rev.B comes
with drivers for a wide variety of networks and operating systems. An
optional boot ROM lets you boot a remote PC/104 station automatically from
a server, making hard or floppy disks unnecessary.
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660Rev.BQuickInstallationGuide1-3
Features
Conforms to IEEE 802.3 Ethernet standards, CSMA/ CD protocol for
10 Mbps data transfer
Hardware and software compatible with Novell NE2000 adapter
Automatically detects 8-bit or 1 6-bit data bus
Remote boot ROM socket for diskless operation
Built-in 10BASE-T transceiver for unshielded twisted pair cabling up to
100 meters
Two diagnostic LEDs indicate network status
Onboard 32K memory for high-performance multi-package buffer
Software drivers for most popular network environments
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660 Rev.B Quick Installation Guide 1-4
Specification
Hardware
Form Factor PC/104
I/O address 200, 220, 240, 260, 280, 2A0, 2C0, 300,
320, 340, 380 or 3A0
Interrupt levels IRQ3, 4, 5, 9, 10, 11, or 15
Boot ROM address C0000, C8000, D0C00 or D8000H
Data bus 8-bit or 16-bit, auto-sensing
Connectors 16-bit PC/104 stack through connector
RJ-45 connector for 10BASE-T, 16-pin
insulation displacement connector for AUI
Dimension 3.5” x 3.8” (90mm x 96 mm )
Software
Driver Support -Lantasti 4.x/5.xdriver
-NDIS 2.x driver
-Packet driver
-SCO UNIX driver
-Netware ODI driver
-NDIS 3.0 miniport driver for Windows NT
31, Windows NT 35 and Windows 95
-OS2driver
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660Rev.BQuickInstallationGuide1-5
-Netware serverdriver
Standard
PC/104 8-bit and 16-bit compatible
Built in IEEE 802.3 10 Mbps CSMA/CD 10BASE-T transceiver
10BASE-2, 10BASE-5 and 10BASE-FOIRL by external transceiver
General
Power +5 V 400 mA max.
Operating
Temperature
32°F~140°F (0°C ~ 60°C)
Storage
Temperature
5°F~176°F (-15°C ~ 80°C)
Humidity 10% ~ 90%
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660 Rev.B Quick Installation Guide 1-6
Installation
Your package should contain the following items. If they are missing,
damaged or fail to meet specifications, contact your dealer/sales
representative immediately.
PCM-3660 Rev.B
Drivers
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660Rev.BQuickInstallationGuide1-7
Software Configuration
The PCM-3660 Rev. B module is supplied with a software utility disk.
This disk contains the files necessary for setting up the Ethernet
controller. Directories and files on the disk are as follows:
1. RSET8019.EXE
This program enables you to view the current Ethernet configuration,
reconfigure the Ethernet interface (medium type, etc.), and execute
useful diagnostic functions.
2. PG8019.EXE
The PCM-3660 is initially set up at the factory using this program.
When you receive your card, use RSET8019.EXE to configure it for
the working environment. If by chance the EEPROM becomes
corrupted, the PG8019.EXE program allows you to reconfigure the
card.
3. 8019AS.CFG
When you run PG801 9.EXE, it will read the configuration
parameters stored in this file.
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660 Rev.B Quick Installation Guide 1-8
Ethernet Interface Configuration
The PCM-3660 Rev.B onboard Ethernet interface supports all major
network operating systems. I/O address and interrupts are easily
configured via the RSET801 9.EXE program included on the utility
disk.
The RSET8019.EXE program provides two ways to configure the
Ethernet interface. Configuration can be done automatically when
you choose PNP (plug and play). When you choose jumperless
configuration, the following IRQ and I/O address settings are
available.
Ethernet Settings
Default Settings: IRO=5; Address=300H
IR0 option I/O address range
Jumperless
Configuration
3, 4, 5, 9,10, 11,15 200-3FFH
Note:
1. You can select an IRQ from the Options shown above, but be sure that
your selection does not conflict with other l/O devices.
2. When Boot ROM is installed, the RSET8019.EXEprogram does not
support PNP mode configuration.
To execute the configuration, to see the current configuration, or run
diagnostics as followings:
1. Power the PCM-3660 Rev.B on. Make sure that the
RSET8019.EXE file is located in a working directory.
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660Rev.BQuickInstallationGuide1-9
2. At the prompt type RSET8019.exe and press <Enter>. Then the
Ethernet configuration program will be displayed.
3. A simple screen displays the available options for the Ethernet
interface. Highlight the option you are going to change and using the
Up and Down keys. To change a selected item press <Enter>, and a
window will show the available options. Highlight your selection and
press <Enter>. Each highlighted option has a helpful message guide
displayed at the bottom of the screen for additional information.
4. After you have made your selections and you are sure that this is
the configuration you want, press <ESC>. A prompt will appear
asking if you want to save the configuration. Press Yif you want to
save.
The Ethernet Setup Menu also offers three very useful diagnostic
functions. These are:
1. Run EEPROM test.
2. Run Diagnostics on Board.
3. Run Diagnostics on Network
Each option has its own display screen which shows the format and
result of any diagnostic tests undertaken.
Remote boot ROM (P/N: PCL-843-ROM)
PC/104 Peripheral Module PCM-3660 Rev.B
PCM-3660 Rev.B Quick Installation Guide 1-10
A boot ROM allows you to boot the workstation directly from the
server, avoiding the need for local hard or floppy disks. Install the
boot ROM as shown below. Make sure that you align the notch on
the ROM chip with the notch on the socket.