M4M 20 NETWORK ANALYZER USER MANUAL 7
2.Packaging contents
Packaging contents
1 Network analyzer M4M 20 or M4M 20-M (MID)
2 Installation manual
3 Calibration certificate
4 Installation accessories (removable terminals, fixing clips)
5 M4M 20-M (MID): Sealable terminal block
The number and type of removable terminals in the package varies according to the different versions.
Please refer to below table to check the removable terminals included in each package.
Product
Name
Current input
terminal (6
poles)
Voltage input
terminal (4
poles)
Auxiliary supply
terminal (2
poles)
Digital outputs
terminal (3
poles)
Programmable
I/O terminal (3
poles)
Analogue output
terminal (3
poles)
RS485 terminal
(3 poles)
M4M 20 X X X X - - -
M4M 20
MODBUS X X X X - - X
M4M 20-M
MODBUS X X X X - - X
M4M 20
ETHERNET X X X X - - -
M4M 20-M
ETHERNET X X X X - - -
M4M 20
PROFIBUS X X X X - - -
M4M 20 I/O X X X X X X X
M4M 20
BACNET X X X X - - -
M4M 20
ROGOWSKI - X X X - - X
Please notice that terminals for current input on M4M 20 Rogowski are pre-wired on ABB’s R4M
Rogowski coils
M4M Calibration Certificate
This Calibration Certificate maynot be reproduced, in whole or in part,
without written permission of ABB
Test Conditions Test Description Accuracy
No. V1
V2
V3
I1
I2
I3
PF Results Limit
#1 230 230 230 6 661 Verification–
Active energy (Import) -0,01% ±0,5% Passed
#2 230 230 230 0,9 0,9 0,9 1 Verification –
Active energy (Import) -0,01% ±0,5% Passed
#3 230 230 230 0,15 0,15 0,15 1 Verification–
Active energy (Import) -0,01% ±0,5% Passed
#4 230 230 230 6 660,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#5 230 230 230 0,9 0,9 0,9 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#6 230 230 230 0,15 0,15 0,15 0,5ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#7 230 230 230 1,5 1,5 1,5 1 Verific ation–
Active energy (Import) -0,01% ±0,5% Passed
#8 230 2 30 230 0,2 0,2 0,2 1 Verification –
Active energy (Import) -0,01% ±0,5% Passed
#9 230 230 230 1,5 1,5 1,5 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#10 2 30 230 230 0,2 0,2 0,2 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#11 230 230 230 6 660,5 ind. Verific ation–
Active energy (Import) -0,01% ±0,5% Passed
#12 230 230 230 0,9 0,9 0,9 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#13 230 230 230 0,15 0,15 0,15 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#14 58 58 58 6 6 6 1 Verification –
Active energy (Import) -0,01% ±0,5% Passed
#15 58 58 58 6 6 6 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#16 230 230 230 6 - 6 1 Verification –
Active energy (Import) -0,01% ±0,5% Passed
#17 230 230 230 0,9 - 0,9 1 Verification –
Active energy (Import) -0,01% ±0,5% Passed
#18 230 230 2 30 0,15 - 0,15 1 Verification –
Active energy (Import) -0,01% ±0,5% Passed
#19 230 230 230 6 - 6 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#20 230 230 230 0,9 - 0,9 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
#21 230 230 230 0,15 - 0,15 0,5 ind. Verification –
Active energy (Import) -0,01% ±0,5% Passed
Contact us
ABBS.p.A .
ElectrificationBusiness
Vialedell’Industria, 18
20010Vittuone (MI) Italy
https://new.abb.com/low-voltage
Graphs
DataReading
Configuration
Network analyzer
INSTALLATIONMANUAL
M4M 20
2CSG445030D0201 July 2019
Warning!Installation by person
withelectrotechnical expertise
only.
Warnung!Installation nur durch
elektrotechnischeFachkraft.
Avvertenza!Fare installare solo da
unelettricista qualificato.
1.Packaging Content
• Networkanalyzer M4M 20
• Installationmanual
• Calibrationcertificate
• 2mounting clips
• Removableterminals for wiring
2.Mounting
2.1.Assembly
2.2.WiringDiagram
Forcurrent measurement, please
noticethat it is needed to fasten
thescrew-type terminal to the
devicewith the two screws.
3.Symbol instruction
Button Function
Shortcutto Home/
Favorite/Notifications
pages.
BACK Returnto the previous
page.
ENTER
Confirmthe selection.
Increaseor decrease the
value.Keeping pressed will
increasethe speed of the
numbervariation.
Movecursor up or down.
Movecursor to the left or to
theright.
Confirmselection with
ENTER
CTratio L1 L2 L3
Selectthe current transformer ratio among
thedefault ones or enter it manually.
Incase of manual entry, enter the value
ofthe primar y with +or -and select the
secondary(1A or 5A).
Enterthe voltage transformer ratio (both
primary and secondary) manually with +or -.
Manual
40/5A
50/5A
60/5A
CTratio L1 L2 L3
-
MORE
Finalizethe installation through
removableterminals.
Defaultpassword is 00000. At
firstuse, the password shall be
defined.In order to disable the
password,please enter 00000.
4.Access to device
Graphs
DataReading
Configuration
Accessto device is done through the five
buttonsunder the screen.
Thehome page is divided in 3 sections:
Sections Description
Graphs
Graphicalrepresentation
ofthe main parameters.
DataReading Valuesof the main
parameters.
Configuration
Setupof the device.
→
→
→
Unit
→
Language
→
→
Installation
→
CT ratio
Incase of direct insertion,
400/400Vvalue shall be used.
→ → Installation → VTratio
CTratio L1 L2 L3
Confirmselection with
ENTER
Confirmselection with ENTER
Confirmselection with
ENTER
3Ph/4W/3CT
3Ph/3W/3CT
3Ph/3W/2CT
3Ph/3W/1CT
Parameter Description
3Ph/4W/3CT 3-phase4-wire + 3CTs
3Ph/4W/1CT 3-phase4-wire + 1CT
3Ph/3W/1CT 3-phase3-wire + 1CT
3Ph/3W/3CT 3-phase3-wire + 3CTs
3Ph/3W/2CT 3-phase3-wire + 2CTs
2Ph/3W/2CT 2-phase3-wire + 2CTs
1Ph/2W/1CT 1-phase2-wire + 1CT
Selectthe type of network among the
followingones:
→
→
Installation
→
Typeof network
3-phase4-wire network with 3CTs
3-phase4-wire network with 1CT
3-phase3-wire network with 1CT
3-phase3-wire network with 3CTs
3-phase3-wire network with 2CTs
2-phase3-wire network with 2CTs
1-phase2-wire network with 1CT
5.First Commissioning
Tostart to use the analyzer it is mandatory
toconfigure the basic setting (password,
language,type of network, CT ratio and VT
ratio).
5.1.Settingpassword
Thepassword is composed by 5 numerical
characters.In order to select each numerical
character,it is necessary to use +or -and
confirmevery selection with ENTER.
5.2.Settinglanguage
5.3.Typeof network
5.4.CurrentTransformer ratio
5.5.VoltageTransformer ratio
Selectthe desired language for the
displayamong the ones available.
QRCode for online
UserManual.