GThese instructions are organised in the following sections:
I. General instructions
II. Possible uses
III. Pack contents
IV. Tools
V. Installation instructions
VI. Operation
I. General instructions
The window universal lock FTS106 is recognised as complying with the
strict test requirements of DIN 18 104-1 and VdS 2536.
FTS106 is certied by DIN Certco as “BURGLAR RETARDANT DIN tested”.
FTS106 oers additional protection from unauthorised intruders in
your rooms. DIN 18 104-1 recommends that an additional security
device should be tted on the left and right for every meter in height
(per window). The police and insurance companies also give the same
recommendation.
Optimum protection can be achieved by proceeding according to these
installation and operation instructions. To prevent the risk of over-
tightening, the fastening screws should be screwed in using a suitable
tool and tightened by hand. Only use ABUS fastening material.
The manufacturer does not assume any liability for possible injuries
or damages caused during installation and/or by incorrect handling!
II. Possible uses
FTS106 is mounted on the handle side of the window or French door
and is suitable for all common windows/French doors opening to the
inside with turn or turn-and-tilt hardware (g. 2).
The lock can be tted to wood, PVC or aluminium.
The windows/French doors can open to the right or left.
FTS106 is always tted on the inside, with the lock case on the casement
and the striking plate on the frame.
In poor xture conditions (soft or hollow or foam base and PVC windows
with and without metal inlay and wooden windows) and/or good
possibilities for intrusion from the outside, more security devices and
additional fastenings should be used (composite mortar or xing bolts).
If the frame itself is too weak for sensible retrotting, it may be necessary
for example to reinforce the frame.
To do so, please use the ABUS xing bolt BA or alternatively for PVC
frames, the ABUS fastening set IM 100. For IM 100 you need a suitable
composite mortar, e.g. Fischer FIS VS150C or similar. ABUS BA and
ABUS IM 100 are available from retail stores together with composite
mortar.
The ABUS products (FAS) shown in g. 2 are also available from retail
stores.
III. Pack contents (g. 3)
1. 1 lock case
2. 1 striking plate
3. 1 screw-on strip
4. 1 cover cap for lock case
5. 1 cover cap for locking case
6. 2 wedge-shaped washers
7. 1 set of spacers for the frame strip 1x1, 2, 4, 5 mm each
8. Screws:
8 each 5.5 x 60 mm
2 each 4.2 x 16 mm
2 each 4.2 x 9.5 mm
1 each M6 x 35 mm
3 each M6 x 25 mm
IV. Tools
Phillips screwdriver
Slotted recess screwdriver
Drill
Saw, le for shortening the screws, possibly vice
Hex key, width across ats 4
for
screws
Ø
in wood and PVC
without metal inlay
drill bit Ø
in aluminium and PVC
with metal inlay
drill bit Ø
4.0 mm
3.0 mm
4.5 mm
3.0 mm
5.5 mm
4.2 mm
Drilling table
GABUS Installation and operation instructions
for ABUS universal window lock FTS106
Abb./g./
schéma/
afb./ill. 10
Abb./g./
schéma/
afb./ill. 11
Abb./g./
schéma/
afb./ill. 12
Abb./g./
schéma/
afb./ill. 13
Abb./g./
schéma/
afb./ill. 5c
Abb./g./
schéma/
afb./ill. 5a
Abb./g./
schéma/
afb./ill. 5b
Abb./g./schéma/afb./ill. 4
Abb./g./
schéma/
afb./ill. 8
Abb./g./
schéma/
afb./ill. 6
Abb./g./
schéma/
afb./ill. 7
Abb./g./
schéma/
afb./ill. 9
3 mm
Unterlagen für Höhenausgleich
Spacers
Entretoises
Opvulplaatjes
Spessori da livellamento
Rahmen
Frame
Cadre
Kozijn
Telaio
3 mm
Tür bzw. Fenster
Door/Window
Fenêtre
Deur/Raam
Porta risp. Finestra
2 mm
Schlosskasten
Lock case
Boîtier
Slotkast
Cassa della serratura
Schließkasten
Locking case
Gâche
Sluitkast
Scatola della
serratura
Falzhöhe
Rebate height
Recouvrement
Opdekmaat
Altezza
d’incassatura
0–29 mm
F
2 mm
C
B
B
C
A
A
C2
D
C1
D
3 mm
E2
E1
E3
GV. Installation instructions:
•Before installation, please check the setting of the window
or French door.
•If necessary, readjust the ttings so that the window (French door)
opens and closes perfectly.
•Also check whether your window/French door complies with the
minimum dimensions shown in g.1.
•The depths of the drilled holes and screw lengths must be adjusted
to the local conditions.
•Avoid the drill or screws from coming out at the back!
Possibly work with drill stopper or shorten the existing screws.
•When drilling, do not damage any moving parts, seals or glass panes.
Installation:
Fitting the lock case:
1. Screw on the knob supplied loose through hole “F” using the Phillips
screwdriver (g. 5a). The screw is already in the lock case (1).
For DIN left (g. 5c), for DIN right (g. 5b).
2. Adjusting the personal code:
The number combination of knob is set to 0-0-0 in the factory.
Adjust the personal code as follows:
a) In the setting 0-0-0, hold the side pin in.
b) Adjust your personal code.
c) Release the side pin again, the new code is now adjuste.
We recommend that you note the code and keep the note
in a safe place. ABUS cannot tell what the secret code is.
3. Remove the cover cap (4) from the lock case (1) from below by pressing
on the catch points (g. 6). Undo the locking bolt.
4. Hold the lock case (1) in the required position against the window
casement or door, at a distance of 2 mm to the edge (g. 7).
5. Mark and pre-drill hole position A and B (for PVC windows and doors
also C) (g. 8 and drilling table).
6. Screw on lock case (1). For holes A (depending on rebate height),
use screws 4.2x16 mm or 4.2x9.5 mm (use screwdriver with magnetic tip).
Holes B (C) screws 5.5x 60 mm.
Fitting the locking case:
The lock case (1) and striking plate (2) must be on the same level (g. 4).
To compensate for the diering rebate heights, the striking plate (2)
is lined, using the screw-on strip (3) and/or the spacers (7).
Rebate height:
from 14 mm [with screw-on strip (3) and possibly shims (7)].
1. Hold the screw-on strip (14 mm high) on the same level and at a parallel
distance of 3 mm to the lock case (1) (g.9). Ensure that the screw-on
strip (3) is in the right position.
2. Mark and pre-drill bore holes C1 and C2 (g. 10 and drilling table).
3. Line screw-on strip (3) with spacers (7) if necessary (rebate height larger
than 14 mm). Screw tight with screws 5.5x 60 mm.
4. Drill in the middle through the slanting screw holes Dat the same
angle to the wall (see drilling table). If this is not possible, drill vertically.
Then place the two wedge-shaped washers (6) in holes D.
5. Screw 2 more screws 5.5x60 mm into holes D.
6. Remove the cover cap (5) from the striking plate (2) from below by
pressing on the catch points (g.11).
7. Screw striking plate (2) to screw-on strip with 3 screws M6x25 mm.
Check function:
Locking bolt must run freely into the striking plate (2) when closing.
8. Press on both cover caps.
Rebate height: 0 to 13 mm (possibly with shims).
1. Remove the cover cap (5) from the striking plate (2) from below
by pressing on the catch points (g.11).
2. Hold striking plate (2) centrally on the same level and at a parallel
distance of 3 mm to the lock case (1) (g.12).
3. Mark and pre-drill holes position E1 to E3 (Fig.13) (see drilling table).
4. Line striking plate (2) with spacers (7) if necessary and screw tight with
3 screws 5.5x 60 mm.
Check function:
Locking bolt must run freely into the striking plate (2) when closing.
5. Press on both cover caps.
VI. Operation
FTS106 can be locked without a key by turning the knob
(possibly adjust code). To open, enter the number combination –
your personally adjusted code number – and turn the knob back.
The number wheels should be changed again after locking and also
after opening unintentionally.

This manual suits for next models

1

Other Abus Lock manuals

Abus DF 88 User manual

Abus

Abus DF 88 User manual

Abus SmartX 770A Manual

Abus

Abus SmartX 770A Manual

Abus Touch 57 User manual

Abus

Abus Touch 57 User manual

Abus 9001 IoTect Manual

Abus

Abus 9001 IoTect Manual

Abus FTS 3003 Operating instructions

Abus

Abus FTS 3003 Operating instructions

Abus KeyGarage 787 Smart-BT User manual

Abus

Abus KeyGarage 787 Smart-BT User manual

Abus FO500 User manual

Abus

Abus FO500 User manual

Abus FTS3003 User manual

Abus

Abus FTS3003 User manual

Abus Touch 56/50 User manual

Abus

Abus Touch 56/50 User manual

Abus PR2800 Manual

Abus

Abus PR2800 Manual

Abus 2010 Manual

Abus

Abus 2010 Manual

Abus KEYGARAGE One User manual

Abus

Abus KEYGARAGE One User manual

Abus F0 500 User manual

Abus

Abus F0 500 User manual

Abus DFS 95 User manual

Abus

Abus DFS 95 User manual

Abus Bordo 6000 PZ User manual

Abus

Abus Bordo 6000 PZ User manual

Abus 808 Reef User manual

Abus

Abus 808 Reef User manual

Abus FTS 206 User manual

Abus

Abus FTS 206 User manual

Abus KEYGARAGE One User manual

Abus

Abus KEYGARAGE One User manual

Abus Touch 57 User manual

Abus

Abus Touch 57 User manual

Abus FTS 88 User manual

Abus

Abus FTS 88 User manual

Abus E360 User manual

Abus

Abus E360 User manual

Abus FTS 99 User manual

Abus

Abus FTS 99 User manual

Abus CodeLoxx User manual

Abus

Abus CodeLoxx User manual

Abus KeyGarage 787 Smart-BT User manual

Abus

Abus KeyGarage 787 Smart-BT User manual

Popular Lock manuals by other brands

Captain E202 user manual

Captain

Captain E202 user manual

National Cabinet Lock C8103 Dimensional drawing

National Cabinet Lock

National Cabinet Lock C8103 Dimensional drawing

Alarm Lock Trilogy DL1200 Programming instructions

Alarm Lock

Alarm Lock Trilogy DL1200 Programming instructions

PDQ CLS Installation instruction

PDQ

PDQ CLS Installation instruction

Assa Abloy Lockwood Optimum manual

Assa Abloy

Assa Abloy Lockwood Optimum manual

Supra TRAC-Guard Installation & user manual

Supra

Supra TRAC-Guard Installation & user manual

Yakima SKS Series Installation

Yakima

Yakima SKS Series Installation

V-Line Simplex instructions

V-Line

V-Line Simplex instructions

Ezviz LT70 manual

Ezviz

Ezviz LT70 manual

Clavis 82021 Code-Combi K Extended Operational instructions

Clavis

Clavis 82021 Code-Combi K Extended Operational instructions

KAS Z-WAVE DIGITAL LOCK Manual operation guide

KAS

KAS Z-WAVE DIGITAL LOCK Manual operation guide

PROMIX SM101 operating manual

PROMIX

PROMIX SM101 operating manual

Gianni Industries EM-1200 specification

Gianni Industries

Gianni Industries EM-1200 specification

GEM EM-NH600 Specification sheet

GEM

GEM EM-NH600 Specification sheet

LEHMANN DIAL LOCK 59 operating instructions

LEHMANN

LEHMANN DIAL LOCK 59 operating instructions

LeeLen T01 Max user manual

LeeLen

LeeLen T01 Max user manual

Stanley 83KM-93KM installation instructions

Stanley

Stanley 83KM-93KM installation instructions

DatoHome L-B200 user manual

DatoHome

DatoHome L-B200 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.