Adam LBX C Series User manual

©AdamEquipmentCompany2020
Adam Equipment
LBX C

©AdamEquipmentCompany2020
Easy Reference:
Model name of the scale:
Serial number of the unit:
Software revision number
(Displayed when power is first turned on):
Date of Purchase:
Name of the supplier and place:

©AdamEquipmentCompany2020
CONTENTS
P.N. 3.02.6.6.15555, Revision A2, September 2020
1.0 INTRODUCTION...................................................................................4
2.0 SPECIFICATIONS.................................................................................5
3.0 SAFETY PRECAUTIONS.....................................................................5
4.0 SET UP..................................................................................................6
4.1 ASSEMBLING OF SCALE................................................................6
5.0 WEIGHING............................................................................................6
5.1 BEFORE WEIGHING.........................................................................6
5.2 WEIGHING.........................................................................................6
5.3 USER PARAMETERS......................................................................7
5.3.1Setting backlight ........................................................................................... 7
5.3.2Auto off .......................................................................................................... 7
5.3.3Unit ................................................................................................................. 7
5.4PARTS COUNTING FUNCTION ....................................................................... 7
5.5MEMORY ACCUMULATION ............................................................................. 7
6.0 CALIBRATION......................................................................................8
6.1USER CALIBRATION PARAMETER SETTING..............................8
7.0 ERROR MESSAGE..............................................................................9
WARRANTY INFORMATION........................................................................10
WARNING:
Pleasereadcarefullyfollowinginstructionsforinstallationand
usebeforestartingyourworkwithanewbalance.Failuretouse
the balance in accordance with the advice in the user manual
couldmeanthattheproductgivesincorrectreadings.

©AdamEquipmentCompany2020
1.0 INTRODUCTION
The LBX C Models are supplied with a power supply adapter, to charge the
internal rechargeable battery.
Four models:
3kg x 0.1g
6kg x 0.2g
15kg x 0.5g
30kg x 1g
3 LCD displays with backlight
5 weighing units: kg, g, lb, oz, and lb:oz
Check-weighing
Indicators for Stable, zero, net weight, and low battery functions
Stainless steel pan with ABS case and pan support
Sealed Membrane keypad
Overload Protection
Spirit level and leveling feet
Auto calibration, zero tracking and tare

©AdamEquipmentCompany2020
2.0 SPECIFICATIONS
Model LBX 3C LBX 6C LBX 15C LBX 30C
Capacity 3Kg 6Kg 15Kg 30Kg
Readability 0.1g 0.2g 0.5g 1g
Repeatability 0.2g 0.4g 1g 2g
Linearity ± 0.2g 0.4g 1g 2g
Units kg / g / lb / oz / lb:oz
Stabilization time 1 second 1 second 1 second 1 second
Operating
temperature
0ºC to 40ºC
32ºF to 104ºF
Power supply
5VDC @ 800mA adapter
4V4.5Ah rechargeable battery
Typical battery life expectancy: 240 hours
Calibration External calibration
Calibration
Weights
1kg,2kg,3kg 2kg,4kg,6kg 5kg,10kg,15Kg 10kg,20kg,30kg
Display 3 x18mm LCD displays
3.0 SAFETY PRECAUTIONS
Caution:
Please use only the original DC adapter supplied with the scale. Other cords or adapters
may damage the scale.
Notice:
Avoid extremes of temperature, do not place in direct sunlight or near air
conditioning vents.
Battery should be removed if the scale is not used for a long period of time.
Do not stack material on the scale when it is not in use.
Avoid high humidity that might cause condensation and keep away from direct
contact with water.
Static may influence the weighing result, to reduce the static wipe the pan and
the scale with anti-static wipes.
When the battery is lower than 3.7v, the battery symbol will flash to
indicate the low battery; when it is lower than 3.4v, the scale will turn off
automatically.

©AdamEquipmentCompany2020
4.0 SET UP
4.1 ASSEMBLING OF SCALE
Put the scale on a stable and even table.
Adjust the height of the feet to level the scale; the spirit level bubble should be
in the centre of the spirit level.
Put the pan support in place, inserting the pan support pins into the holes on top
of the scale. Place the stainless steel pan on the support.
Avoid excess force to weighing pan or the load cell could be damaged.
5.0 WEIGHING
5.1 BEFORE WEIGHING
Check the setting of the auto shut off function, see section 6.2. If the auto shut
off function is on, the scale will shut off after a period of time if the scale is not
used and it has a stable reading.
5.2 WEIGHING
Press [On/Off] to turn on the scale. The display will show the software revision
then show the model “CAP XX”. Then it will begin its self-checking test from 0 to
9. When reading is stable, the display will show "", stable symbol, zero
symbol, and the weighing unit used the last time the scale was used.
Press [UNITS/→] to select units from "g" / "kg" / "lb" / "oz"/”lb:oz”. Only the
weighing units enabled will be displayed.
Check if the reading is “”, if not, press [Zero]. “” and the zero symbol will
be displayed.
Put the item to be weighed on the pan. When the reading is stable, the gross
weight will be shown.

©AdamEquipmentCompany2020
If a container is used, put the container on the pan and press the [Tare/↵] key when the
reading is stable. The display will show “”, the zero symbol and ‘NET’. Load the
container or remove material from the container, the scale will show the net weight of
the material added or removed.
5.3 USER PARAMETERS
The parts counting, percent weighing and calibration functions can be accessed using
the [CE] key. In normal weighing press and hold [CE] key to enter user settings.
5.3.1 Setting backlight
BK backlight can be set as ‘’auto’’, ‘’on’’, ‘’off’’; default is ‘’auto’’. To select the available
option press keys 1 and 6 and then press Tare key to confirm your selection.
5.3.2 Auto off
Auto off can be set as ‘’off’’, ‘’1 min’’, ‘’5 min’’, ‘’10 min’’; default is ‘’5 min’’. To select the
available option press keys 1 and 6 and then press Tare key to confirm your selection.
5.3.3 Unit
Apart from kg, all other weighing units can be enabled or disabled.
5.4 PARTS COUNTING FUNCTION
• In normal weighing mode, press hand count the number of pieces to be counted
and put them on the scale. Using the numerical keys enter the count and press
[SMPL] key.
• If the weight of the item is known, enter this using the keypad and press [unit
weight] key to confirm. The weight entered will be displayed in the middle display
window.
5.5 MEMORY ACCUMULATION
When parts counting, put the number of parts to be counted on the top pan, press
[M+] key, the display will show ACC and the number of the memory entry, so for
example ACC 1 will be the first memory entry.
Ensure there is no weight on the top pan and the display is showing zero;

©AdamEquipmentCompany2020
Add another sample to the top pan and press the [M+] key; the memory entry will
be incremented by 1, the middle display will show total weight of all samples
counted in memory and the right display will show the total count of all samples
in memory.
To recall the total of the memory function, press the [M+] key when there is no
weight on the top pan.
To clear the memory, press [M+] key when there is no weight on the top pan and
then press the [CE] key; the display will briefly show ACC 0 to indicate the
memory has been cleared.
6.0 CALIBRATION
Calibration before use is recommended for best accuracy. It is suggested that
the scale be calibrated when first installed and any time the scale is moved to a
different environment.
Ensure weights are ready before calibrating, the weight should be of a known
accuracy, for example OIML class M1 or Class 4 of ASTM E617.
Do not calibrate the scale if a proper calibration weight is not available.
6.1 USER CALIBRATION PARAMETER SETTING
When power on, press TARE during self-checking, enter pass code 1000 to access user
calibration parameter.
Use keys 1 and 6 to select available options and press TARE button to conform the
selection.
U-CAL (user calibration)
This parameter sets the calibration of the scale. Press [TARE]; display will show unload;
with no weight on the top pan and the stable indicator On, press [TARE] key to set the
zero point. The display will then indicate the load (SET) amount. Use Keys 1 and 6 and
CE to enter the desired load amount and then press the [TARE] key. The display will then
show the pre-selected (LOAD) amount for calibration; put this weight on the top pan, wait
for the stable indicator to show on the display and then press the [TARE] key.
AdCnt – this will show the internal A/D counts.

©AdamEquipmentCompany2020
7.0 ERROR MESSAGE
--AdO
A/D counts are too high
--AdL
A/D counts are too low
BEEP 15
Wrong operation
- -OL- -
Overload 9d
and “BATTLO”
Low battery indication
-- Err -
Over zero key range

©AdamEquipmentCompany2020
WARRANTY INFORMATION
Adam Equipment offers Limited Warranty (Parts and Labour) for the
components failed due to defects in materials or workmanship. Warranty starts
from the date of delivery.
During the warranty period, should any repairs be necessary, the purchaser
must inform its supplier or Adam Equipment Company. The company or its
authorized Technician reserves the right to repair or replace the components
at any of its workshops depending on the severity of the problems. However,
any freight involved in sending the faulty units or parts to the service center
should be borne by the purchaser.
The warranty will cease to operate if the equipment is not returned in the
original packaging and with correct documentation for a claim to be processed.
All claims are at the sole discretion of Adam Equipment.
This warranty does not cover equipment where defects or poor performance
is due to misuse, accidental damage, exposure to radioactive or corrosive
materials, negligence, faulty installation, unauthorized modifications or
attempted repair or failure to observe the requirements and recommendations
as given in this User Manual. Additionally rechargeable batteries (where
supplied) are not covered under warranty.
Repairs carried out under the warranty does not extend the warranty period.
Components removed during the warranty repairs become the company
property.
The statutory right of the purchaser is not affected by this warranty. The terms
of this warranty is governed by the UK law. For complete details on Warranty
Information, see the terms and conditions of sale available on our web-site.

©AdamEquipmentCompany2020
WEEE2012/19/EU
Thisdevicemaynotbedisposedofindomesticwaste.ThisalsoappliestocountriesoutsidetheEU,pertheir
specificrequirements.Disposalofbatteries(iffitted)mustconformtolocallawsandrestrictions.
Cetappareilnepeutêtreéliminéaveclesdéchetsménagers.L’éliminationdelabatteriedoitêtreeffectuée
conformémentauxloisetrestrictionslocales.
DiesesGerätnichtmitdemHausmüllentsorgt.
Dispositivonopuedeserdesechadojuntoconlosresiduosdomésticos
Dispositivononpuòesseresmaltitoneirifiutidomestici.
FCC/ICCLASSADIGITALDEVICEEMCVERIFICATIONSTATEMENT
NOTE:Thisequipmenthasbeentestedandfoundtocomplywiththe limits for a Class A digital device,
pursuanttoPart15oftheFCCrulesandCanadianICES‐003/NMB‐003regulation.Theselimitsaredesignedto
providereasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedinacommercial
environment.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledand
usedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradiocommunications.
Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuser
willberequiredtocorrecttheinterferenceathisownexpense.
CALIFORNIAPROPOSITION65‐MANDATORYSTATEMENT
WARNING:Thisproductincludesasealedlead‐acidbatterywhichcontainschemicalsknowntotheStateof
Californiatocausecancerandbirthdefectsorotherreproductiveharm
AdamEquipmentproductshavebeentestedwith,andarealwayssuppliedwith
mains power adaptors which meet all legal requirements for the intended
country or region of operation, including electrical safety, interference and
energyefficiency.Asweoftenupdateadaptorproductstomeetchanging
legislationitisnotpossibletorefertotheexactmodelinthismanual.Please
contactusifyouneedspecificationsorsafetyinformationforyourparticular
item.Donotattempttoconnectoruseanadaptornotsuppliedbyus.

©AdamEquipmentCompany2020
ADAMEQUIPMENTisanISO9001:2015certifiedglobalcompanywithmorethan40years’experienceintheproduction
andsaleofelectronicweighingequipment.
AdamproductsarepredominantlydesignedfortheLaboratory,Educational,HealthandFitness,RetailandIndustrial
Segments.Theproductrangecanbedescribedasfollows:
‐AnalyticalandPrecisionLaboratoryBalances
‐CompactandPortableBalances
‐HighCapacityBalances
‐Moistureanalysers/balances
‐MechanicalScales
‐CountingScales
‐DigitalWeighing/Check‐weighingScales
‐HighperformancePlatformScales
‐Cranescales
‐MechanicalandDigitalElectronicHealthandFitnessScales
‐RetailScalesforPricecomputing
ForacompletelistingofallAdamproductsvisitourwebsiteatwww.adamequipment.com
AdamEquipmentCo.Ltd.
MaidstoneRoad,Kingston
MiltonKeynes
MK100BD
UK
Phone:+44(0)1908274545
Fax:+44(0)1908641339
e‐mail:
sales@adamequipment.co.uk
AdamEquipmentInc.
1,FoxHollowRd.
06478
USA
Phone:+12037904774
Fax:+12037923406
e‐mail:
sales@adamequipment.com
AEAdamGmbH.
Instenkamp4
D‐24242Felde
Germany
Phone+49(0)4340403000
Fax:+49(0)43404030020
e‐mail:
AdamEquipmentS.A.(Pty)Ltd.
7MegawattRoad,
SpartanEXT22
KemptonPark,
Johannesburg,
RepublicofSouthAfrica
Phone+27(0)119749745
Fax:+27(0)113922587
e‐mail:
sales@adamequipment.co.za
AdamEquipment(S.E.ASIA)PTYLtd
70 Miguel Road
Bibra Lake
Perth
WA 6163
WesternAustralia
Phone:+61(0)864616236
Fax+61(0)894564462
e‐mail:
sales@adamequipment.com.au
AdamEquipment(Wuhan)Co.Ltd.
ABuildingEastJianhua
PrivateIndustrialPark
ZhuanyangAvenue
WuhanEconomic&
TechnologicalDevelopmentZone
430056Wuhan
P. R . C h i n a
Phone:+86(27)59420391
Fax+86(27)59420388
e‐mail:
info@adamequipment.com.cn
©CopyrightbyAdamEquipmentCo.Allrightsreserved.Nopartofthispublicationmaybereprintedortranslated
inanyformorbyanymeanswithoutthepriorpermissionofAdamEquipment.
AdamEquipmentreservestherighttomakechangestothetechnology,features,specificationsanddesignofthe
equipmentwithoutnotice.
Allinformationcontainedwithinthispublicationistothebestofourknowledgetimely,completeandaccuratewhen
issued.However,wearenotresponsibleformisinterpretationswhichmayresultfromthereadingofthismaterial.
ThelatestversionofthispublicationcanbefoundonourWebsite.
www.adamequipment.com
This manual suits for next models
4
Table of contents
Other Adam Scale manuals

Adam
Adam GBK 16a User manual

Adam
Adam Luna LAB Series User manual

Adam
Adam CPWplus 35 User manual

Adam
Adam TBB User manual

Adam
Adam AGF Series User manual

Adam
Adam AGB35 User manual

Adam
Adam GC INDICATOR User manual

Adam
Adam GBK Mplus Series User manual

Adam
Adam AE-202 User manual

Adam
Adam CBC-M Series User manual