manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Adaptec
  6. •
  7. Computer Hardware
  8. •
  9. Adaptec RAID 5405Z User manual

Adaptec RAID 5405Z User manual

SERIES 5Z DATA SHEET
>
Unied Serial®(SATA/SAS) RAID Controllers Deliver Maximum Performance,
Energy Efciency and Operating Cost Savings
Adaptec 3Gb/s SATA & SAS RAID Family
with Intelligent Power Management & Zero-Maintenance
Cache Protection (5405Z, 5445Z, 5805Z)
Product Highlights
3Gb/s throughput at each port
1.2GHz Dual Core RAID on Chip
(ROC)
– High-performance RAID 5/6
4- and 8-port low-profile MD2
Supports up to 256 SATA or
SAS devices
Enclosure management support
via LED header and SES2/
SGPIO
Intelligent Power Management
– Reduces power and cooling
costs by as much as 70%
Adaptec Zero-Maintenance
Cache Protection with 4GB
NAND flash:
– No data loss from power failures:
Replaces lithium ion batteries
– Low Operating Costs:
No installation, monitoring, main-
tenance, disposal or replacement
costs due to batteries
– Maintenance-free cached data
protection
– Instant RAID cache protection
– Environmentally conscious
– No toxic battery disposal
– Simplified IATA compliance
Hybrid RAID 1 & 10: SSD +
HDD for Maximum Performance
and Reliability
Built upon on our industry-leading Series 5
RAID controllers, Series 5Z cards feature a dual
core RAID on Chip (ROC), DDR2 533MHz
write cache, and an x8 PCI Express host bus
connection. ey support up to 256 SATA/SAS
devices and feature Adaptec Intelligent Power
Management for improved energy-eciency, plus
Zero-Maintenance Cache Protection (ZMCP —
pronounced “zemcap”) to help data centers save
thousands of dollars in operating costs.
Highest Performance
Series 5Z controllers deliver speeds up to ve times
faster than competing products — over 250,000
IOPs and 1.2GB/s — making them ideal for
enterprise-class storage systems.
Advanced Data Protection
Adaptec RAID Code (ARC) delivers maximum
reliability with RAID levels 0, 1, 1E, 5, 5EE, 6,
10, 50, 60 and JBOD. ARC also oers RAID
Level Migration, Online Capacity Expansion,
and Copyback Hot Spare.
Hybrid RAID
With Hybrid RAID 1 & 10 the Series 5Z
controllers oer maximum performance and
reliability by combining Solid State Drives (SSDs)
and Hard Disk Drives (HDDs) in a single array.
By performing read operations from the faster
SSD and write operations on both the SSDs and
HDDs the result is tremendous performance
gains over standard HDD RAID arrays. Hybrid
RAID oers the benets of both technologies and
allows a better cost per GB ratio than comparable
SSD-only RAID arrays.
The Case for Cache
e fastest way for a RAID controller to fulll
a read or write request is to serve data out of its
cache. Enabling the RAID controller cache oers
signicant performance benets, such as reduced
latency in I/O requests, bandwidth and queue
depths that surpass soware application limits, and
on-the-y parity calculations on sequential writes.
Zero-Maintenance Cache Protection
RAID controllers typically employ battery backup
units (BBUs) to protect cached data during power
loss, but BBUs require constant monitoring and
preserve data for a maximum of 72 hours during
power loss. Adaptec Series 5Z controllers with
Zero-Maintenance Cache Protection provide full
protection to cached data with no installation,
monitoring, maintenance, disposal, or replacement
costs.
Featuring 4GB of NAND ash memory with
super capacitor technology, Series 5Z controllers
instantly save cache contents in the event of system
power loss. e super capacitor charges instantly
while the system is booting, cache protection
is available within minutes of installation, and
stored data is preserved for up to 10 years. And,
since it is ash-based, systems don’t need to be
shut down for battery replacement.
Intelligent Power Management
Intelligent Power Management (IPM) slashes
power and cooling costs by up to 70% using
intelligent I/O caching combined with disk drive
power savings via standby and power-o modes.
One-view Storage Management
Adaptec Storage Manager™, a one-view tool
centralizes management of all Adaptec RAID
products.
Broad Operating System Support
e Series 5Z family supports all major operating
systems, including Windows, Linux, VMware and
FreeBSD.
Compatibility, Reliability, and Support
e Series 5Z family has been extensively tested
with more than 300 third-party components to
deliver the utmost in compatibility. e cards are
backed by a 3-year warranty and the company’s
legendary technical support.
™
SERIES 5Z DATA SHEET
Adaptec SATA & SAS RAID Family (5405Z, 5445Z, 5805Z)
PMC-Sierra, Inc.
1380 Bordeaux Dr.
Sunnyvale, CA 94089 USA
Tel: +1 (408) 239-8000
© Copyright PMC-Sierra, Inc. 2011. All rights reserved. PMC, PMC-SIERRA and Adaptec are registered trademarks of PMC-Sierra, Inc. “Adaptec by PMC” is a trademark of PMC-Sierra, Inc.
Other product and company names mentioned herein may be trademarks of their respective owners. For a complete list of PMC-Sierra trademarks, see www.pmc-sierra.com/legal.
DS_Series5Z_121311_US Information subject to change without notice.
World Wide Web: www.adaptec.com
Pre-Sales Support: US and Canada: 1 (800) 442-7274 or (408) 957-7274 or [email protected]
UK: +44 1276 854 528 or [email protected]
Australia: +61-2-90116787
Singapore: +65-92351044
Adaptec Unified Serial Controller Family
Why to buy? Performance Unified Serial RAID controllers support both SATA and SAS devices and offer unique features including Zero Maintenance
Cache Protection and Intelligent Power Management. Ideal for bandwidth intensive storage applications; NAS, online transaction processing
servers (OLTP), web servers, digital surveillance and streaming applications.
Customer Needs High I/O transaction and high bandwidth processing; solutions that reduce energy consumption and maintenance costs
Zero Maintenance Cache
Protection
— Maximizes performance and extends power savings by protecting data in controller cache without incurring monitoring, replacement or
disposal costs.
— Support for full installation lifecycle – up to ten years – ensuring data availability and reducing total cost of ownership.
Intelligent Power
Management
Automated customer-configurable feature that reduces disk drive energy use by up to 70% without compromising application
performance. Two configurable modes supported:
Standby mode – low-power mode; spins disks at lower RPMs (must be supported by disk drive).
Power-off mode – Spin down drives when not in use.
RAID Features — Supports up to 256 SATA or SAS devices using SAS expanders
— RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 and JBOD
— Quick initialization
— Online Capacity Expansion
— Copyback Hot Spare
— Dynamic caching algorithm
— Native Command Queuing (NCQ)
— Background initialization
— Hot-plug drive support
— RAID Level Migration
— Hot spares - global, dedicated, and pooled
— Automatic/manual rebuild of hot spares
— SES and SAF-TE enclosure management
— Configurable stripe size
— S.M.A.R.T. support
— Multiple arrays per disk drive
— Dynamic sector repair
— Staggered drive spin-up
— Bootable array support
— Optimized Disk Utilization
Management Utilities Adaptec Storage Manager™ (ASM)
— Java-based GUI Management Utility
— Remote configuration, monitoring and notification
— ASM OS Support: Windows, Linux, SCO, Solaris, FreeBSD
— Microsoft VDS Support
— SNMP, SMTP
— Remote firmware updates
ARCCONF
— Command Line Interface
Adaptec BIOS Configuration Utility (ACU)
— BIOS level configuration utility
— Flashable BIOS support
Operating System Windows 7, Windows XP, Server 2003/2008, Vista, VMware ESX 3.x, ESXi 3.x and vSphere 4, Red Hat Enterprise Linux (RHEL), SUSE Linux Enter-
prise Server (SLES), SCO OpenServer, UnixWare, Sun Solaris 10 x86, FreeBSD. The latest drivers are available at www.adaptec.com/support.
Physical Dimensions 5405Z/5445Z/5805Z — 2.5”H x 6.6”L (64mm x 167mm)
Operating Temperature* 0°C to 55°C (with 200 LFM airflow)
Operating Voltage 0.40A @ 3.3V; 1.2A @ 12V
Regulatory Certification CE, FCC, UL, C-tick, VCCI
Environmental Compliance RoHS, REACH
MTBF 873,402 hours at 40°C
Warranty 3 years
Adaptec RAID 5405Z 5805Z 5445Z
Order Part Number 2266800-R (single) 2266900-R (single) 2267000-R (single)
Form Factor MD2 - Low Profile MD2 - Low Profile MD2 - Low Profile
Ports 4 internal 8 internal 8 (4 int / 4 ext)
Connectors 1 SFF-8087 (int.) 2 SFF-8087 1 SFF-8087 (int.) / 1 SFF-8088 (ext.)
Bus Interface 8-Lane PCIe Gen1.1 8-Lane PCIe Gen1.1 8-Lane PCIe Gen1.1
Processor 1.2 GHz Dual Core 1.2 GHz Dual Core 1.2 GHz Dual Core
Cache 512MB 512MB 512MB ™
*Note: This Adaptec card contains a powerful RAID processor which requires adequate airflow to operate reliably. Please install this card only into server or PC chassis with recommended airflow (200 LFM).
Ambient temperature measured 1” away from the RAID processor.

Other manuals for RAID 5405Z

2

This manual suits for next models

2

Other Adaptec Computer Hardware manuals

Adaptec RAID 2405 User manual

Adaptec

Adaptec RAID 2405 User manual

Adaptec ASR-2130SLP How to use

Adaptec

Adaptec ASR-2130SLP How to use

Adaptec DuraStor 7200S User manual

Adaptec

Adaptec DuraStor 7200S User manual

Adaptec 2045 User manual

Adaptec

Adaptec 2045 User manual

Adaptec RAID 5405 User manual

Adaptec

Adaptec RAID 5405 User manual

Adaptec SATA RAID FOR ADAPTEC User manual

Adaptec

Adaptec SATA RAID FOR ADAPTEC User manual

Adaptec PM3754U2 User manual

Adaptec

Adaptec PM3754U2 User manual

Adaptec PM3332UW User manual

Adaptec

Adaptec PM3332UW User manual

Adaptec RAID 2405 User manual

Adaptec

Adaptec RAID 2405 User manual

Adaptec AAA-130SA SERIES Assembly Instructions

Adaptec

Adaptec AAA-130SA SERIES Assembly Instructions

Adaptec M3093GX Operating and maintenance manual

Adaptec

Adaptec M3093GX Operating and maintenance manual

Adaptec ASR-3085 Operating manual

Adaptec

Adaptec ASR-3085 Operating manual

Adaptec RAID Solutions Manual

Adaptec

Adaptec RAID Solutions Manual

Adaptec AAA-130U2 SERIES Assembly Instructions

Adaptec

Adaptec AAA-130U2 SERIES Assembly Instructions

Adaptec P Class 733/800/866MHz / 1GHz User manual

Adaptec

Adaptec P Class 733/800/866MHz / 1GHz User manual

Adaptec 7210S Use and care manual

Adaptec

Adaptec 7210S Use and care manual

Adaptec 2410SA - Serial ATA RAID Controller User manual

Adaptec

Adaptec 2410SA - Serial ATA RAID Controller User manual

Adaptec AHA-2940 - SCSI Card User manual

Adaptec

Adaptec AHA-2940 - SCSI Card User manual

Adaptec RAID 5085 User manual

Adaptec

Adaptec RAID 5085 User manual

Adaptec CDP-00277-01-A User manual

Adaptec

Adaptec CDP-00277-01-A User manual

Adaptec AAR-1420SA Instruction Manual

Adaptec

Adaptec AAR-1420SA Instruction Manual

Adaptec SAS RAID Controllers User manual

Adaptec

Adaptec SAS RAID Controllers User manual

Adaptec ACB-232XD User manual

Adaptec

Adaptec ACB-232XD User manual

Adaptec 1200A User manual

Adaptec

Adaptec 1200A User manual

Popular Computer Hardware manuals by other brands

CyberResearch CYB 2232C user manual

CyberResearch

CyberResearch CYB 2232C user manual

RF-Star RF-ZM-2530B1 instruction manual

RF-Star

RF-Star RF-ZM-2530B1 instruction manual

Syntacore SCR1 SDK quick start guide

Syntacore

Syntacore SCR1 SDK quick start guide

Shure DFR22E manual

Shure

Shure DFR22E manual

Avalue Technology ECM-945GSE Quick installation guide

Avalue Technology

Avalue Technology ECM-945GSE Quick installation guide

Epson S5U13719P00C100 user manual

Epson

Epson S5U13719P00C100 user manual

Renesas ISL5217EVAL1 user manual

Renesas

Renesas ISL5217EVAL1 user manual

COUGAR AQUA 360 manual

COUGAR

COUGAR AQUA 360 manual

Siemens PAD-5-CLSA installation guide

Siemens

Siemens PAD-5-CLSA installation guide

ekwb EK-XTOP Revo Dual D5 Serial INSTALLATION AND MOUNTING MANUAL

ekwb

ekwb EK-XTOP Revo Dual D5 Serial INSTALLATION AND MOUNTING MANUAL

Linear Technology DC1057 quick start guide

Linear Technology

Linear Technology DC1057 quick start guide

Avalue Technology SID-10W03 Quick reference guide

Avalue Technology

Avalue Technology SID-10W03 Quick reference guide

nRichDX Revolution user manual

nRichDX

nRichDX Revolution user manual

Omron CQM1H - 08-2005 Operation manual

Omron

Omron CQM1H - 08-2005 Operation manual

Panasonic 2SA1739 Specification sheet

Panasonic

Panasonic 2SA1739 Specification sheet

Watercool HEATKILLER GPU-X2 4870 Assembly instructions

Watercool

Watercool HEATKILLER GPU-X2 4870 Assembly instructions

Supero BPN-SAS3-213A user guide

Supero

Supero BPN-SAS3-213A user guide

EK-Quantum Vector FE RTX 3070 Ti D-RGB + Backplate user guide

EK-Quantum

EK-Quantum Vector FE RTX 3070 Ti D-RGB + Backplate user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.