ADE PWN5 User manual

OPERATING MANUAL
Stainless steel scale for the food sector
Compact scale with stainless steel ho sing
- Model PWN5
PWN5-191210-Rev005-UM-en
IMPORTANT
OBSERVE THE INSTRUCTIONS FOR USE
PLEASE KEEP FOR FUTURE REFERENCE
ADE Germany GmbH & Co.KG
Hammer Steindamm 27 – 29
22089 Hamb rg / GERMANY
+49 (0) 40 432776-0
Fax +49 (0) 40 432776-10
E-mail: info@ade-germany.de

1 PWN5-191210-Rev005-UM-en
Table of Contents
1. Overview display.......................................................................................................... 2
Button functions .................................................................................................................. 2
2. LCD display ................................................................................................................. 2
3. Installation, operation and f nction .............................................................................. 3
3.1
Inspecting the contents of the box ....................................................................... 3
3.2
Levelling the scale .................................................................................................. 3
3.3
Supplying power to the scale ................................................................................ 3
3.4
Charge status display and battery charge ......................................................... 3
3.5
Switching on ............................................................................................................ 4
3.6
Weighing mode + unit change ............................................................................... 4
3.7
Presetting the units ................................................................................................. 5
3.8
Taring ....................................................................................................................... 5
3.9
Setting minimum and maximum values for checkweighing............................... 5
3.10
Backlight .................................................................................................................. 6
4. Display and error messages ........................................................................................ 6
5. Care and maintenance ................................................................................................ 6
5.1
Care and cleaning ................................................................................................... 6
5.2
Storage and Transport Conditions ........................................................................ 6
5.3
Disposal ................................................................................................................... 6
5.4
Warranty ................................................................................................................... 6
5.5
Safety inspection .................................................................................................... 7
6. CE marking and declaration of conformity ................................................................... 7
7. Technical data ............................................................................................................. 8

PWN5-191210-Rev005-UM-en 2
1. Overview display
Button functions
2. LCD display
Scale weight is stable.
Weight is negative.
Indicates low battery charge; flashes d ring charging.
Displayed if the parameter setting is the maxim m val e.
Displayed if the parameter setting is the minim m val e.
Set- p and confirmation b tton
Unit b tton and backlight setting
Power b tton
Tare b tton in weighing mode

3 PWN5-191210-Rev005-UM-en
3. Installation, operation and f nction
Yo r ADE PWN5 compact scale with stainless steel ho sing is a q ality prod ct designed for
non-approvable checkweighing.
The scale is remarkable for its easy handling. Thanks to the small digit interval, precise weight
meas rements can be performed easily and q ickly.
An a dible signal in conj nction with freely programmable minim m and maxim m limits
expands the possible applications, for example, when weighing rec rring weights.
The stainless steel ho sing is waterproof according to IP67 protection class and can also be
sed in wet working environments.
To achieve precise meas rement res lts, please read the operating man al caref lly and
follow the instr ctions contained therein. Keep this man al in a safe place for f t re reference.
3.1 Inspecting the contents of the box
Checkweigher
Weighing platform
User man al incl. declaration of conformity
Rechargeable batteries 4.8 V 1800 mAh (installed in the scale)
AC/DC adapter
3.2 Levelling the scale
Caref lly remove the scale from the packaging.
Level the scale so that all feet are in contact with the installation s rface. The footing m st be
level and safe.
3.3 Supplying power to the scale
Power is s pplied either by means of the incl ded mains adapter or thro gh the
rechargeable batteries installed in the device.
3.4 Charge status display and battery charge
The scale has a battery stat s indicator that lights p in the event of a low battery charge.
For mains operation as well as for charging the battery, first
connect the incl ded mains adapter to the connector on the
back of the scale (see ill stration on the right) and then to the
mains s pply.
Make s re that the voltage of the local mains s pply matches the operating voltage of the
scale.
Use only the incl ded mains adapter.
The charging process can take p to five ho rs.
A f lly charged battery can operate contin o sly p to 14 ho rs.
If the operating time with f lly charged batteries is drastically red ced, the battery m st be
replaced. In this case, please contact yo r local dealer or service partner.

PWN5-191210-Rev005-UM-en 4
If you will not be using the scale for an extended period of time, disconnect
the charger from the mains supply to protect the battery.
3.5 Switching on
Remove all weights from the weighing s rface.
Press the power b tton. All symbols are shown on the LCD display d ring the power-on
ro tine. After that, the scale shows “0g” and is ready for weighing.
If the selected nit has been changed before the last power-off, the scale will show “0.000lb”,
“0:0.00lb:oz” or “0.00oz”.
3.5.1 Switching off
To t rn off the scale, press the power b tton.
3.5.2 Automatic power-off (in battery operation only)
The scale has an a tomatic power-off that can be preset by the ser in config ration mode.
In the as-delivered condition, the a tomatic power-off is preset to 120 seconds (120).
To change the preset, t rn on the scale, wait for the power-on ro tine to complete and then
start the config ration mode by pressing and holding down the “SET” b tton for 3 seconds ntil
the display shows “SEt”. After releasing the b tton, the display will show “Unit”.
Press the [UNIT] b tton and the display will show “AOFF”.
Press the [SET] b tton to switch to the presetting options. Press the [UNIT] b tton to select
the time ntil a tomatic power-off. The s ccession is 120, 180, 240, 300, OFF and again 120.
The val es are the power-off time in seconds.
Once the desired val e is displayed, press [SET] to confirm the selection.
The display will show the config ration item “AOFF”.
Use the [UNIT] b tton to enter the next men item “GrA ”. This f nction is reserved for service
technicians only. Once “GrA ” appears on the display, press the [UNIT] b tton to confirm; the
display will show “End”. Press [SET] to confirm and go back to the weighing mode.
3.5.3 Automatic power-off at low voltage
If the battery charge is too low, the scale will t rn off a tomatically.
3.6 Weighing mode + unit change
P t the object to be weighed on the scale. Once the scale is stable, the weight will be displayed
within one second.
The weight can be displayed in “g”, “lb”, “lb:oz” and “oz” nits, which can be changed by
pressing the [UNIT] b tton. The nit that has been set before the last power-off of the scale
will be displayed when it is t rned on again later.
If the scale is overloaded, the display will show “OL”. In this case, immediately remove the
object to be weighed to prevent permanent damage to the scale.

5 PWN5-191210-Rev005-UM-en
3.7 Presetting the units
The vario s nits s ch as “g”, “lb”, “lb:oz” and “oz” can be separately enabled or disabled as
needed.
To do this, press and hold down the [SET] b tton for 3 seconds ntil the display shows “SEt”.
After releasing the b tton, the display will show “UNIT”.
Now press the [SET] b tton. The display will show “g” as the nit of weight. Repeatedly press
the [UNIT] b tton to enable (“ON”) or disable (“OFF”) the nit.
Press the [SET] b tton to confirm the selection and switch to the “lb/oz” nit stat s display.
To enable or disable the nit selection, press the [UNIT] b tton and confirm the selection as
described above.
Perform these steps also for the “lb/oz1/8”, “lb”, “oz” and “oz1/8” nits.
After confirmation of the last nit of weight to be selected, the display will show “UNIT”.
3.8 Taring
There are two taring options: a tomatic taring when yo t rn on the scale and taring d ring the
weighing process.
With a tomatic taring, p t the container to be tared on the scale before t rning on the scale
and then t rn on the scale. The display will show “0”. As soon as yo p t the object to be
weighed into the container, only the net weight of the object to be weighed will be displayed.
This process can be repeated as often as desired ntil the maxim m weight is reached.
If the scale is already t rned on, taring will take place d ring the weighing process.
P t yo r empty container on the scale and press the [TARE] b tton. The scale display will
show “0”. Now p t the object to be weighed into the container. The scale now shows only the
net weight. This process can be repeated as often as desired ntil the maxim m weight is
reached. Press the [SET] and [TARE] b ttons at the same time to display the total weight. If
yo remove the container and the objects to be weighed, the display will show the weight as a
negative val e. Press the [TARE] b tton again to cancel the tare f nction.
If the display is not stable, the stability indicator will not light up.
3.9 Setting minimum and maximum values for checkweighing
It is possible to set the minim m and maxim m val es on the scale with an a tomatic playing
of an a dible signal. It is very helpf l if, for example, always the same filling q antities are
weighed.
Press and hold down the [TARE] b tton for 3 seconds to set the minim m and maxim m
val es for checkweighing. After a short beep, the “LOW” symbol will flash and switch back to
the “0” display. Now place the weight corresponding to the minim m weight on the weighing
platform and press the [SET] b tton to confirm. A beep will so nd to confirm the stored
minim m val e.
The “HIGH” symbol flashes now. Now add the corresponding weight to the minim m weight
ntil the desired maxim m val e is reached and press the [SET] b tton to confirm. A beep will
so nd to confirm the stored maxim m val e.
Remove the weight from the weighing platform.
If yo now place an arbitrary weight on the weighing s rface, a beep will so nd as long as the
applied weight is below or above the set val es.

PWN5-191210-Rev005-UM-en 6
Briefly press the [SET] and [TARE] b ttons at the same time to delete the stored minim m
and maxim m val es. The scale will confirm the inp t with a short beep.
3.10 Backlight
For better readability, the display has a backlight that is enabled after each power-on. Press
and hold down the [UNIT] b tton for approx. 3 seconds to disable the backlight for low power
cons mption. Press and hold down the [UNIT] b tton for approx. 3 seconds again to enable
the backlight.
4. Display and error messages
“OL” Overload - the scale is overloaded. Weight exceeds the permissible total
weight.
Low battery - charge the battery.
5. Care and maintenance
5.1 Care and cleaning
Before cleaning, disconnect the device from the power s pply. When cleaning, do not se any
aggressive cleaning agents b t only a cloth and water or ne tral disinfectant.
Do not clean the scale with a high-pressure cleaner!
5.2 Storage and Transport Conditions
Keep all parts of the packaging in case yo need to ret rn the shipment to avoid possible
damage d ring transportation.
5.3 Disposal
Used electrical equipment and batteries do not belong in the domestic waste.
Please dispose of defective or old products and batteries with the legal and
authorised channels!
Please make sure that only discharged batteries or batteries with insulated
"poles" are disposed of as otherwise they may short-circuit!
5.4 Warranty
ADE will repair or replace this prod ct if there is evidence is that it failed within one year from
the date of sale (proof of p rchase req ired) by poor workmanship or defective material. All
moving parts, s ch as batteries, cables, etc. are excl ded.

7 PWN5-191210-Rev005-UM-en
The se of accessories other than those approved by ADE, especially batteries, will void the
warranty.
This warranty does not cover external normal wear and tear or damage ca sed by accident or
mis se. The warranty will not apply for devices that have been opened by na thorised
persons. The stat tory rights of the c stomer are not affected by this agreement in any way.
The dealer from whom the scale was p rchased is responsible for complaints, c stomer
service and spare parts.
5.5 Safety inspection
Safe operation is no longer g aranteed:
- if the power s pply is visibly damaged.
- if the power s pply is no longer f nctioning.
- after prolonged storage in h mid areas.
Notify yo r service partner in these cases for yo r own safety.
6. CE marking and declaration of conformity
ADE applies the relevant EC Directives and E ropean standards in order to offer eq ipment
worldwide according to the latest state of the art and with a long service life.
ADE prod cts comply with the strict E ropean directives for man fact re and sale of
professional scales and meas ring instr ments.
Declaration of conformity by the manufacturer
These scales have been man fact red in accordance with the harmonised E ropean standards. It
conforms to the provisions of the EC directives cited below:
EMC Directive 2014/30/EU regarding electromagnetic compatibility
Low voltage directive 2014/35/EU
RoHS Directive 2011/65/EU
in the c rrently valid versions.
This declaration will lose its validity if any modification is made to the scale witho t o r consent.
Hamb rg, Dezember 2019
ADE Germany GmbH & Co.KG
Hammer Steindamm 27-29
D-22089 Hamb rg

PWN5-191210-Rev005-UM-en 8
7. Technical data
Type PWN5
Maximum load: 5 kg
Division = d 1 g
Min. weight 20 d
Maximum tare 100% maxim m weight
Model
PWN5
Weighing s rface
180 x 171 mm, stainless steel, removable
Dimensions 187 x 244 x 54 mm
Net weight
1.80 kg
Gross weight 2.20 kg
Temperat re range
+10°C to + 40°C
Ho sing
Solid stainless steel ho sing
Protection class IP67
Power s pply AC adapter (100-240 V AC 50/60 Hz inp t, 9 V/1000 mA o tp t)
and battery operation (4.8 V 1800 mAh)
Units
5000 g / 1 g
10 lb / 0.1 oz
10 lb / 0.005 lb
10 lb / 1/8 oz 160 oz / 0.05 oz 160 oz / 1/8 oz
Display
Large LCD display with white
backlight, digit height 30 mm
F nctions Weighing, Taring,
A tomatic zeroing,
Freely programmable minim m and maxim m val es for
checkweighing with a dible s pport,
Overload indicator
A tomatic power-off (in battery operation),
Battery level
indicator (if battery is low)

9 PWN5-191210-Rev005-UM-en
Man fact rer: ADE Germany GmbH & Co.KG
Hammer Steindamm 27-29
D – 22089 Hamb rg
Germany
+49 (0) 40 432776-0
Fax +49 (0) 40 432776-10
E-mail: info@ade-germany.de

PWN5-191210-Rev005-UM-en 10

11 PWN5-191210-Rev005-UM-en
Distributor:
Table of contents