For the most up to date version of the MagnaClean Professional2XP Installation and Servicing
instructions visit adey.com/us. Warranty Terms & Conditions can be found at adey.com/us/support/
register-warranty
Maximum working pressure: 87 PSI
Maximum working temperature: 95°C / 203°F
Flow rate: <21 gal/min
Inlet: Bi-directional
MagnaClean filter contains a strong magnet. Keep away from all electrical devices, bank cards
and other magnetic devices.
MagnaClean filter contains a strong magnet. Caution should be taken at all times when handling
if you have a pacemaker fitted.
MagnaClean filter is a pressurized device. Always release pressure before servicing.
Unit may be hot in operation. Handle with care.
IMPORTANT - Always follow the electrical and safety standards when installing a
MagnaClean filter ensuring pipework is appropriately earth bonded either side of the filter.
WARNING - Cancer and reproductive Harm
www.P65Warnings.ca.gov
CAUTION:
Important
MagnaClean Professional2XP has been developed with a greater filter capture capacity providing
protection for larger residential hydronic heating systems.
MagnaClean Professional2XP®
Combi/sealed system
Open vented system
MagnaClean Professional2XP can be installed anywhere before the boiler. To achieve the best
level of protection, it is recommended that the filter is fitted after the last radiator and before the
boiler. This also ensures a system flush can be carried out using a MagnaCleanse®on the return
(position A only).
Installation overview
Note: In both diagrams, position A is best practice, Position B is suitable if space is tight on the return.
New filter installation
4
24
3
4
1
- Always ensure the filling loop is fitted after the filter.
Cut and remove
section using
measurement
guide sticker
supplied.
Guide sticker
supplied with
valve assembly.
Valve A
Valve B
1
2
The following instructions are designed to support contractors in the safe and effective installation
and servicing of MagnaClean Professional2XP and should be followed at all times. It is recommended
that the filter is installed by a qualified heating contractor. The lid seal should be checked for wear
when servicing MagnaClean®. It is Best Practice to replace the lid seal at each service. To arrange
Always re-dose the system with a suitable protector such as ADEY MC1+®Hydronic Heating
System Protector
CAUTION:
Do NOT overtighten.
1
22