manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AJAX
  6. •
  7. Security Sensor
  8. •
  9. AJAX FireProtect User manual

AJAX FireProtect User manual

Updated April 22, 2021
FireProtect (FireProtect Plus) is a wireless indoor fire detector with an in-built
buzzer and a battery, ensuring up to 4 years of autonomous operation.
FireProtect can detect smoke and rapid temperature increase.
Aside from these functions, FireProtect Plus additionally can alert of dangerous
CO level. Both detectors can function independently from the hub.
Connecting to the Ajax security system via a secured radio protocol,
FireProtect (FireProtect Plus) communicates with the at a distance of up to
1,300 m in line of sight.
The detector can be a part of third-party security systems, connecting to them
via the or integration module.
The detector is set up via the for iOS, Android, macOS, and Windows.
The system notifies the user of all events through push notifications, SMS, and
calls
(
if activated
)
.
The Ajax security system can be connected to a central monitoring station of a
security company.
When smoke penetrates the detector chamber, it distorts infrared light between
the emitter and photoelectric receiver. This distortion triggers a smoke alarm.
When the temperature exceeds 60°Сor rises by 30°Сduring 30 minutes (not
necessary to reach 60°С), the detector registers temperature increase, which
triggers a fire alarm.
1. Siren hole
2. Light indicator (acts as the sensor and Test button)
3. Smoke chamber hole with the temperature detector behind the net
4. SmartBracket attachment panel
5. Power button
6. Tamper button
7. QR code
The life span of the FireProtect Plus detector lasts up to 7 years (up to 10 years for the
). In the event of a detector failure, you will receive a corresponding
notification — it will need to be replaced or submitted for .
FireProtect Plus has an additional sensor to detect a dangerous CO level. If the
concentration of CO in the air exceeds a certain level, the detector generates an
alarm.
The detector is triggered:
In case of alarm, the detector activates the built-in buzzer (the siren sound can
be heard from afar) and blinks with the light indicator. When connected to a
security system, both the user and the security company are notified of the
alarm.
The siren of the device can be turned off using three ways:
within 60–90 min at carbon oxide concentration 50 ppm / 0.005%
within 10–40 min at CO concentration 100 ppm / 0.01%
within 3 min at carbon oxide concentration 300 ppm / 0.03%.
1. By pressing the Ajax logo on the device lid (there is a touch button under the
logo).
2. Through the Ajax app. In case of fire alarm, you will see a pop-up message in
Please note that for this to work you need to priorly select Mute Interconnected
Fire Alarmcommand for this button in the KeyPad settings.
If smoke and/or temperature levels do not restore to normal values, in 10
minutes, the FireProtect/FireProtect Plus turns on the siren again.
3. Using the (if Interconnected FireProtect Alarms feature is enabled).
To turn off the built-in sirens in case of fire alarm, press the “*” button on the
KeyPad.
Before starting connection:
Only users with administrator rights can add the device to the hub
Pairing the detector with hub:
1. Following the hub user guide, install the . Create the account, add
the hub, and create at least one room.
2. Switch on the hub and check the internet connection (via Ethernet cable
and/or GSM network).
3. Make sure that the hub is disarmed and does not update by checking its
status in the Ajax app.
1. Select Add Device in the Ajax app.
2. Name the device, scan or type the QR Code (located on the detector body
and packaging), and select the location room.
3. Tap Add — the countdown will start.
To make sure that the detector is on, press the on/off button — the logo will light
up red for a second.
For detection and pairing to occur, the detector should be located within the
coverage area of the wireless network of the hub (at a single protected object).
The connection request is transmitted for a short time: at the moment of
switching on the device.
If pairing with the hub fails, the detector operates autonomously; switch off the
detector for 5 seconds and retry.
The detector connected to the hub is displayed in the list of devices in the app.
The update of the detector status in the list depends on the device inquiry time
set in the hub settings (the default value is 36 seconds).
To connect the detector to a third party security central unit using the
or integration module, follow the
recommendations in the manual of the respective device.
The smoke detector always operates in the active mode. When connecting
FireProtect to third party security systems, it is appropriate to place it in a
permanently active protection zone.
Parameter State
Temperature Temperature of the device. Measures on the
device processor and changes gradually
Jeweller Signal Strength Signal strength between the hub and the
detector
Connection Connection status between the hub and the
device
Battery Charge
Battery level of the device. Two states available:
Lid The tamper state of the device — reacts to the
detachment
ReX Displays the status of using the ReX range
extender
Smoke Shows if smoke is detected
Temperature Threshold Exceeded The state of temperature threshold exceeded
alarm
Rapid Temperature Rise The state of rapid temperature increase alarm
High CO Level (FireProtect Plus only) The state of dangerous CO level alarm
Backup Battery Charge Backup battery level of the device
Smoke sensor The state of the smoke detector
Smoke Sensor Dust Level The dust level in the smoke chamber
Temporary Deactivation
Shows the status of the device: active,
completely disabled by the user, or only
notifications about triggering of the device
tamper button are disabled
2. FireProtect | FireProtect Plus
ОК
Battery discharged
Setting Value
First field Device name, can be edited
Room Selecting the virtual room to which the device is
assigned
Dangerous CO Level Alarm (FireProtect Plus
only)
If active, the detector alerts of exceeding the
limits of carbon monoxide concentration
High Temperature Alarm If active, the detector reacts when the
temperature is 60°C and higher
Rapid Temperature Rise Alarm
If active, the detector reacts to rapid
temperature increase (30°Сfor 30 minutes or
less)
Alert with a siren if smoke is detected If active, added to the systemare
activated in case of smoke alarm
Alert with a siren if temperature threshold
exceeded
If active, added to the systemare
activated in case if temperature threshold
exceeded
Alert with a siren if rapid temperature rise
detected
If active, added to the systemare
activated in case if rapid temperature rise
detected
Alert with a siren if CO detected (FireProtect
Plus only)
If active, added to the systemare
activated in case if CO concentration is
dangerous
Jeweller Signal Strength Test Switches the device to the signal strength test
mode
FireProtect Self Test Starts FireProtect selftest
Allows the user to disconnect the device
1. Devices
2. FireProtect | FireProtect Plus
3. Settings
Temporary Deactivation
Note that a disabled device does not trigger an
interconnected alarm of fire detectors. But if
smoke is detected, the built-in siren will sound
User Guide Opens the detector User Guide
Unpair Device Deletes device and its settings
The function activates built-in sirens of all fire detectors if at least one of them is
triggered. Sirens are activated within the hub–detector ping interval according to
the Jeweller settings.
To enable Interconnected Alarms:
1. Open the Devices tab in the
2. Select a hub
3. Go to its Settings by pressing
4. Select the Service item
5. Go to the Fire detectors settings menu and activate the Interconnected
FireProtect Alarms option
Interconnected alarms are supported by FireProtect and FireProtect Plus detectors with
firmware versions 3.42 and later. Please note that when you turn on the interconnected
alarms, you cannot set the hub–detector ping interval (Jeweller settings) of more than 48
seconds.
Lid only— the system will ignore only
notifications about the triggering of the
device tamper button
minute.
The function works as follows:
1. One of the FireProtect/FireProtect Plus detectors detects an alarm.
2. Delay of Interconnected Alarms starts.
3. The built-in siren of the fire detector informs the alarm. Users receive
notifications in the Ajax app (if are enabled). At the
object, are activated (if the are enabled).
4. An alarm confirmation event is sent to the monitoring station and security
system users, and the system starts the interconnected alarm for fire detectors
if:
The interconnected alarm delay time has passed, and the triggered detector
is still registering an alarm.
During the delay of the interconnected alarms, the triggered detector
reports a different type of alarm (for example, the detector report the
exceeding of the temperature threshold after a smoke alarm).
During the interconnected alarm delay, another fire detector in the system
raised an alarm.
00:00 00:14
00:00 00:13
minutes:
If a triggered detector does not return to a normal state within 10 minutes after the user
postponed the interconnected alarm, another fire detector reports an alarm, or a
triggered detector reports an alarm of another type (for example, temperature and
smoke), the system will send an alarm confirmation and activate interconnected alarm
for fire detectors.
Through Ajax apps.
By pressing the KeyPad function button (in the interconnected fire alarm
muting mode).
By pressing the Button in the interconnected fire alarm muting mode.
By eliminating the cause of the alarm (fire detectors at the facility no longer
detect an alarm).
By pressing the touch button of the triggered fire detector.
7. If necessary, activate the Ignore First Alarm option. This setting is
recommended for premises with potential sources of false alarms. For example,
if the device is installed in a place where dust or steam can get into the detector.
The option functions as follows:
1. The detector reports a smoke alarm.
2. The built-in 30-second timer of the detector starts.
3. If after 30 seconds the detector still detects a threat, an alarm is sent to the
hub.
Event Indication
Detector switching on The logo lights up green for 1 second
Detector switching off The logo blinks red three times and the device
switches off
Registration failed The logo blinks green for a minute, then the
device switches to the autonomous mode
Smoke or temperature increase detected The siren switches on, the logo lights red during
the fire/smoke alarm
One short sound signal per 90 sec — main
batteries low (CR2)
The tests do not start straight away but within a period of 36 seconds when
using the standard settings. The test time start depends on the settings of the
detector scanning period (the paragraph on “Jeweller” settings in hub settings).
According to the requirements of EN50131 standard, the level of the radio signal
sent by wireless devices is decreased during the test mode.
Before installing the detector, check the smoke sensor. To test it, switch on the
detector and press the sensor button (the logo center) for a few seconds – the
detector will test the smoke chamber with electronic simulation of smoke
generation and then will switch on the siren for 6 seconds.
You will receive the notification in the Ajax app regarding the test result and
detector status.
of signal reception.
Check the Jeweller signal level at the installation location
If the detector has low or unstable signal strength even after moving, use a
.
Install the detector at the ceiling in the highest point where hot air and smoke
are concentrated in case of fire.
If there are any beams at the ceiling, protruding by 30 or more centimeters from
the ceiling level, install the detector between every two beams.
Before installing the detector, make sure that you have selected the optimal
location that follows the guidelines of this manual!
If LED doesn’t blink after fixing in SmartBracket, check the status of the tamper
in the and then the fixing tightness of the panel.
If someone detaches the detector from the surface or takes it off the
attachment panel, the security system notifies you.
Do not install the detector:
Use double-side adhesive tape only for temporary attachment of the detector. The
tape runs dry with time, which can cause falling, false triggering, and detector
malfunction.
2. Put the detector on the attachment panel by turning it clockwise on
SmartBracket. When the detector is fixed in SmartBracket, it blinks with LED,
signaling that the tamper is closed.
1. outside the premises (outdoors);
2. nearby any metal objects or mirrors causing attenuation or screening of the
signal;
3. at any places with fast air circulation (air fans, open windows or doors);
4. closer than a meter to the cooking surface;
5. inside premises with the temperature and humidity beyond the range of
permissible limits;
In case of autonomous use, the detector notifies of the detected fire/smoke with
the siren sound and light of the logo. To switch off the siren, press the logo
(there is a sensor button) or eliminate the cause of the actuated alarm.
Check the operational capability of the detector regularly. Clean the detector
body from dust, spider web, and other contaminants as they appear. Use soft dry
napkin suitable for tech equipment.
Do not use any substances containing alcohol, acetone, gasoline, and other
active solvents to clean the detector.
To a certain level, the detector ignores the dust in the smoke chamber. When the
chamber becomes too dusty, the detector notifies the user of the need to clean it
via the app (and beeps every minute and a half). Such maintenance is
compulsory for the detector to operate correctly.
Pre-installed batteries ensure up to 4 years of autonomous operation. If the
batteries are discharged, the security system sends the respective notifications
and the detector signal with a sound every 90 seconds:
if the main batteries are low — a single short signal;
Smoke-sensitive element Photoelectric sensor
Temperature sensitive element Thermocouple
Sound notification volume 85 dB at a distance of 3 m
Alarm threshold at the temperature +59°С±2°С
Tamper protection Yes
Frequency band 868.0 – 868.6 MHz or 868.7 – 869.2 MHz
depending on the region of sale
Compatibility
Operates independently or with all Ajax ,
, ,
Maximum RF output power Up to 20 mW
Radio signal modulation GFSK
Radio signal range Up to 1,300 m (any obstacles absent)
Power supply 2 × CR2 (main batteries), CR2032 (backup
battery), 3 V
Battery life Up to 4 years
Warranty for the “AJAX SYSTEMS MANUFACTURING” LIMITED LIABILITY
COMPANY products is valid for 2 years after the purchase and does not apply to
the pre-installed battery.
If the device does not work correctly, you should first contact the support service
— in half of the cases, technical issues can be solved remotely!
1. FireProtect (FireProtect Plus)
2. SmartBracket mounting panel
3. Batteries CR2 (pre-installed) — 2 pcs
4. Battery CR2032 (pre-installed) — 1 pcs
5. Installation kit
6. Quick Start Guide

Other manuals for FireProtect

9

This manual suits for next models

5

Other AJAX Security Sensor manuals

AJAX DoorProtect User manual

AJAX

AJAX DoorProtect User manual

AJAX MotionCam User manual

AJAX

AJAX MotionCam User manual

AJAX FireProtect 2 Jeweller User manual

AJAX

AJAX FireProtect 2 Jeweller User manual

AJAX MotionProtect User manual

AJAX

AJAX MotionProtect User manual

AJAX ReX User manual

AJAX

AJAX ReX User manual

AJAX MotionProtect User manual

AJAX

AJAX MotionProtect User manual

AJAX Fire Protect User manual

AJAX

AJAX Fire Protect User manual

AJAX FireProtect 2 (Heat) Jeweller User manual

AJAX

AJAX FireProtect 2 (Heat) Jeweller User manual

AJAX DoorProtect Plus User manual

AJAX

AJAX DoorProtect Plus User manual

AJAX DoorProtect User manual

AJAX

AJAX DoorProtect User manual

AJAX FireProtect User manual

AJAX

AJAX FireProtect User manual

AJAX CombiProtect User manual

AJAX

AJAX CombiProtect User manual

AJAX DualCurtain Outdoor User manual

AJAX

AJAX DualCurtain Outdoor User manual

AJAX MotionProtect Curtain User manual

AJAX

AJAX MotionProtect Curtain User manual

AJAX FireProtect 2 User manual

AJAX

AJAX FireProtect 2 User manual

AJAX LeaksProtect User manual

AJAX

AJAX LeaksProtect User manual

AJAX MotionProtect User manual

AJAX

AJAX MotionProtect User manual

AJAX DoorProtect User manual

AJAX

AJAX DoorProtect User manual

AJAX GlassProtect User manual

AJAX

AJAX GlassProtect User manual

AJAX FireProtect 2 Jeweller User manual

AJAX

AJAX FireProtect 2 Jeweller User manual

AJAX LeaksProtect User manual

AJAX

AJAX LeaksProtect User manual

AJAX FireProtect User manual

AJAX

AJAX FireProtect User manual

AJAX DoorProtect User manual

AJAX

AJAX DoorProtect User manual

AJAX GlassProtect User manual

AJAX

AJAX GlassProtect User manual

Popular Security Sensor manuals by other brands

Micropack FDS300 installation guide

Micropack

Micropack FDS300 installation guide

Elko iNels RFMD-100 quick start guide

Elko

Elko iNels RFMD-100 quick start guide

HIOTH TECHNOLOGY CT-SMEO2001-ID user manual

HIOTH TECHNOLOGY

HIOTH TECHNOLOGY CT-SMEO2001-ID user manual

Assa Abloy Yale SR-A100-0EIR Installation

Assa Abloy

Assa Abloy Yale SR-A100-0EIR Installation

Bosch DS939 installation instructions

Bosch

Bosch DS939 installation instructions

RAB Lighting STL12LV installation manual

RAB Lighting

RAB Lighting STL12LV installation manual

Prime Controls LH200H operating instructions

Prime Controls

Prime Controls LH200H operating instructions

Mannesmann 99980 instruction manual

Mannesmann

Mannesmann 99980 instruction manual

PCB Piezotronics 118B11 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 118B11 Installation and operating manual

ActiV C4408R manual

ActiV

ActiV C4408R manual

PSM LD161 installation guide

PSM

PSM LD161 installation guide

LEGRAND Plexo 695 01 manual

LEGRAND

LEGRAND Plexo 695 01 manual

Elkron IR600VC Installation, programming and functions manual

Elkron

Elkron IR600VC Installation, programming and functions manual

Honeywell Miller EN 360 Picture guide

Honeywell

Honeywell Miller EN 360 Picture guide

Carrier HyperSense 7C-HS-C1W-X installation guide

Carrier

Carrier HyperSense 7C-HS-C1W-X installation guide

Eaton COOPER POWER SERIES Installation and maintenance instructions

Eaton

Eaton COOPER POWER SERIES Installation and maintenance instructions

BEA IXIO-ST manual

BEA

BEA IXIO-ST manual

TH COMMUNICATIONS MotionProtect Outdoor user manual

TH COMMUNICATIONS

TH COMMUNICATIONS MotionProtect Outdoor user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.