manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Allied Telesis
  6. •
  7. Media Converter
  8. •
  9. Allied Telesis AT-PB300 Series User manual

Allied Telesis AT-PB300 Series User manual

This manual suits for next models

4

Other Allied Telesis Media Converter manuals

Allied Telesis AT-IMC100T/SCSM User manual

Allied Telesis

Allied Telesis AT-IMC100T/SCSM User manual

Allied Telesis AT-UMC2000/SC User manual

Allied Telesis

Allied Telesis AT-UMC2000/SC User manual

Allied Telesis IMC2000 Series User manual

Allied Telesis

Allied Telesis IMC2000 Series User manual

Allied Telesis AT-MC1005/2 User manual

Allied Telesis

Allied Telesis AT-MC1005/2 User manual

Allied Telesis Converteon AT-CV102 Series User manual

Allied Telesis

Allied Telesis Converteon AT-CV102 Series User manual

Allied Telesis MMC2000 Series User manual

Allied Telesis

Allied Telesis MMC2000 Series User manual

Allied Telesis AT-G8T User manual

Allied Telesis

Allied Telesis AT-G8T User manual

Allied Telesis AT-FS201 Series User manual

Allied Telesis

Allied Telesis AT-FS201 Series User manual

Allied Telesis AT-LMC10SC User manual

Allied Telesis

Allied Telesis AT-LMC10SC User manual

Allied Telesis AT-MCR1 User manual

Allied Telesis

Allied Telesis AT-MCR1 User manual

Allied Telesis AT-MC13 User manual

Allied Telesis

Allied Telesis AT-MC13 User manual

Allied Telesis Converteon AT-CV5M01 User manual

Allied Telesis

Allied Telesis Converteon AT-CV5M01 User manual

Allied Telesis CONVERTEON AT-CM201 User manual

Allied Telesis

Allied Telesis CONVERTEON AT-CM201 User manual

Allied Telesis AT-MC115XL User manual

Allied Telesis

Allied Telesis AT-MC115XL User manual

Allied Telesis AT-MC601 Series User manual

Allied Telesis

Allied Telesis AT-MC601 Series User manual

Allied Telesis MMC2000/200 Series User manual

Allied Telesis

Allied Telesis MMC2000/200 Series User manual

Allied Telesis AT-MMC6005 User manual

Allied Telesis

Allied Telesis AT-MMC6005 User manual

Allied Telesis AT-MC102 User manual

Allied Telesis

Allied Telesis AT-MC102 User manual

Allied Telesis AT-MC1004 User manual

Allied Telesis

Allied Telesis AT-MC1004 User manual

Allied Telesis DMC1000/100 Series User manual

Allied Telesis

Allied Telesis DMC1000/100 Series User manual

Allied Telesis AT-9924SP User manual

Allied Telesis

Allied Telesis AT-9924SP User manual

Allied Telesis UMC2000 Series User manual

Allied Telesis

Allied Telesis UMC2000 Series User manual

Allied Telesis AT-LMC100SC User manual

Allied Telesis

Allied Telesis AT-LMC100SC User manual

Allied Telesis Converteon AT-CV1KSS User manual

Allied Telesis

Allied Telesis Converteon AT-CV1KSS User manual

Popular Media Converter manuals by other brands

TR-Electronic CMS582M-4096/4096 IOL DMS 14H7 KRF Assembly instructions

TR-Electronic

TR-Electronic CMS582M-4096/4096 IOL DMS 14H7 KRF Assembly instructions

Korenix JetCon 2301S user manual

Korenix

Korenix JetCon 2301S user manual

StarTech.com ET91000LCOAM manual

StarTech.com

StarTech.com ET91000LCOAM manual

Alesis AI-3 Reference manual

Alesis

Alesis AI-3 Reference manual

Caton Vpro 5100 user guide

Caton

Caton Vpro 5100 user guide

Cypress CSC-5500 Operation manual

Cypress

Cypress CSC-5500 Operation manual

H&B TX-100 Installation and instruction manual

H&B

H&B TX-100 Installation and instruction manual

Bolin Technology D Series user manual

Bolin Technology

Bolin Technology D Series user manual

IFM Electronic Efector 400 RN30 Series Device manual

IFM Electronic

IFM Electronic Efector 400 RN30 Series Device manual

GRASS VALLEY KUDOSPRO ULC2000 user manual

GRASS VALLEY

GRASS VALLEY KUDOSPRO ULC2000 user manual

Linear Technology DC1523A Demo Manual

Linear Technology

Linear Technology DC1523A Demo Manual

Lika ROTAPULS I28 Series quick start guide

Lika

Lika ROTAPULS I28 Series quick start guide

Weidmuller IE-MC-VL Series Hardware installation guide

Weidmuller

Weidmuller IE-MC-VL Series Hardware installation guide

Optical Systems Design OSD2139 Series Operator's manual

Optical Systems Design

Optical Systems Design OSD2139 Series Operator's manual

Tema Telecomunicazioni AD615/S product manual

Tema Telecomunicazioni

Tema Telecomunicazioni AD615/S product manual

KTI Networks KGC-352 Series installation guide

KTI Networks

KTI Networks KGC-352 Series installation guide

Gira 0588 Series operating instructions

Gira

Gira 0588 Series operating instructions

Lika SFA-5000-FD user guide

Lika

Lika SFA-5000-FD user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Technical Specifications
Maximum Operating Temperature: 0° C to 40° C (32° F to 104° F)
Maximum Storage Temperature: -20° C to 80° C (-4° F to 17 ° F)
Operating Altitude: Up to 3,048 meters (10,000 feet)
Humidity: 5% to 80% (non-condensing)
EMC: FCC Class A, EN55022 Class A,
EN55024
Safety: EN 0825, EN 0950, UL1950 (UL/cUL)
Electrical Safety and Emission Statement
Standards: This product meets the following standards.
RFI Emission EN55022 Class A
WARNING: In a domestic environment this product may causeradio interference in which case the user may
be required to take adequate measures.
Immunity EN55024
Electrical Safety EN60950, UL1950 (UL/cUL)
Laser EN60825
Copyright  2001 Allied Telesyn International, Corp.
All rights reserved. No part of this publication may be reproduced without prior written permission
from Allied Telesyn International, Corp.
Allied Telesyn International Corp.
9 0 Stewart Drive, Suite B
Sunnyvale, CA 94085 USA
Tel 1 (408) 730-0950 • Fax 1 (408) 73 -0100
Visit our web site at: www.alliedtelesyn.co
e
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to
operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
Overview
The AT-PB300 Series Media Converters are hot swappable modules for the
PowerBlade Chassis. The AT-PB300 Series Media Converters are designed to
extend the distance of your network by allowing you to interconnect twisted
pair cabling and fiber optic cabling. Each unit features an 100Base-TX twisted
pair port and an 100Base-FX fiber optic port. The twisted pair port has an
RJ-45 connector and a maximum operating distance of 100 meters (328 feet).
The fiber optic port has an VF-45, MT-RJ, LC, or FJ connector, depending on
the model, and a maximum operating range of 2 kilometers (1.2 miles). The
AT-PB300 Series Media Converters operate at 100 Mbps and feature half- and
full-duplex operation.
Related Documents
This quick install guide is an abbreviated version of the installation
procedures. For complete details on the features and functions of these media
converters and for additional installation instructions, refer to the PowerBlade
Chassis Installation Guide. This guide is available from the Allied Telesyn
web site at www.alliedtelesyn.com.
Cable Specifications
The following table lists the maximum operating distances for the AT-PB300
Series Media Converters.
Model 100Base-TX 100Base-FX Port
Connector Maximum Distance Connector Maximum Distance
AT-PB301 RJ-45 100 m (328 ft) VF-45 2 km (1.2 mi)
AT-PB302 RJ-45 100 m (328 ft) MT-RJ 2 km (1.2 mi)
4PN 613-50198-00 Rev A 010329
AT-PB300 Series
Fast Ethernet Media Converters
Quick Install Guide
For use in the PowerBlade Chassis
Note1: Maximum distancecan only beobtained when the UTP/STPcabling is installed and verifiedto TIA/EIA 568ACommercial
Building Telecommunications Cabling Standard.
Note 2: Maximum distance for 100 Mbps Optical Datalinksare dependenton thefollowing factors:typeof optical fiber, duplex
mode of both end-nodes, and maximum optical lossbudget for each of the optical fiber at the operating optical
wavelength.
The following table lists the cable specifications for the 100Base-TX twisted
pair port.
The following table lists the cabling specifications for the 100Base-FX fiber
optic port when operating in full-duplex mode.
Cable specifications for the 100Base-FX fiber optic port operating in half-
duplex mode and fiber optic port specifications can be found in the
PowerBlade Chassis Installation Guide.
Package Contents
Make sure the following items are included in your package. If any item is
missing or damaged, contact your Allied Telesyn sales representative.
❑One AT-PB300 Series Media Converter Module
❑This quick install guide
❑Warranty card
Installing a Media Converter
1. Remove a blank faceplate from an empty expansion slot on the front of the
chassis. The module can be installed in any slot.
2. Remove the module from the shipping package and store the packaging
material in a safe place. Be sure to observe standard ESD precautions.
3. Set the Auto-negotiation switch on the board to enable or disable auto-
negotiation of the duplex mode on the module. Refer to the PowerBlade
Chassis Installation Guide for the location of the Auto-negotiation switch.
4. Slide the module into the expansion slot, aligning it with the guiderails
until it firmly connects to the chassis’ backplane.
5. Secure the module to the chassis by tightening the thumbscrew.
. Verify that the PR LED on the front of the module is green. If the LED is
OFF, refer to the PowerBlade Chassis Installation Guide for
troubleshooting instructions.
7. Set the ML/LT button to the Link Test (OUT) position. This enables the
link test feature.
8. Remove the dust cover from the fiber optic port and connect the fiber optic
cable to the 100Base-FX port.
9. Connect the twisted pair cable to the 100Base-TX twisted pair port.
10. Set the MDI/MDI-X button to the appropriate setting.
11. The module is now ready for use. Repeat this procedure to install
additional AT-PB300 Series modules.
Refer to the PowerBlade Chassis Installation Guide for additional
information.
Status LEDs
AT-PB303 RJ-45 100 m (328 ft) LC 2 km (1.2 mi)
AT-PB304 RJ-45 100 m (328 ft) FJ 2 km (1.2 mi)
Model Connector Cable Maximum Distance
All models RJ-45 Unshielded or shielded twisted
pair Category 5 or better 100 m (328 ft)
Model Cable Maximum
Distance
Maximum
Allowable Loss
Budget
All models 50/125 micron multimode fiber
optic cable 2 km (1.2 mi) 13.0 dB at 1310 nm
62.5/125micronmultimodefiber
optic cable 2 km (1.2 mi) 16.8 dB at 1310 nm
Model 100Base-TX 100Base-FX Port
Connector Maximum Distance Connector Maximum Distance
LED Color Description
PR Green Power is applied to the media converter.
ML Green The MissingLink feature is enabled.
OFF The unit is performing a Link Test.
FD Green The ports are operating in full-duplex mode.
OFF The ports are operating in half-duplex mode.
LK Green A link is established on the port.
AT Flashing Green Data is being received or transmitted by the port.
2 3