
3
CONTENTS
1 Risks and protections before assembly.................................4
2 Intended use .............................................................................4
3 Precautions ...............................................................................4
4 Package content .......................................................................4
5 Position on farming machine ..................................................5
5.1 System recommended composition.................................5
5.2 Control unit fixing .............................................................6
5.3 Wiring harness connection ..............................................6
6 Wiring connections ..................................................................7
6.1 General precautions for a correct harness position .........7
6.2 Control unit (ECU) connection .........................................7
6.3 Control unit valve connection...........................................8
6.4 Hydraulic valve connection ..............................................8
6.5 Sensor connection...........................................................9
7 ISOBUS system cable connection ........................................10
7.1 Connection of in-cab cable ............................................10
7.2 Connection of ISOBUS cable.........................................10
8 “OBJECT POOL” loading .......................................................11
9 Setting .....................................................................................12
9.1 Tests and checks before setting.....................................12
9.2 Control layout.................................................................12
10 Implement settings > BASIC SETTINGS...............................13
10.1 Home > Data and settings > Implement settings
> Basic settings..............................................................14
11 Implement settings > Advanced Setup .................................15
11.1 Home > Data and settings > Implement settings
> Boom settings .............................................................16
11.1.1 Home > Data and settings > Implement settings
> Boom settings > Set coverage........................................ 16
11.2 Home > Data and settings > Implement settings
> Flowmeters .................................................................17
11.3 Home > data and settings > implement settings
> Pressure sensor..........................................................18
11.4 Home > data and settings > implement settings
> Valves .........................................................................19
11.5 Home > Data and settings > Implement settings
> Nozzles data...............................................................19
11.6 Home > data and settings > implement settings
> Speed .........................................................................20
11.7 Home > data and settings > implement settings
> Rev counter.................................................................20
11.8 Home > data and settings > implement settings
> Tank .............................................................................. 20
11.9 Home > data and settings > implement settings
> Device calibration .......................................................21
11.9.1 Home > Data and settings > Implement settings
> Device calibration > Press. sensor zero value................. 21
11.9.2 Home > Data and settings > Implement settings
> Device calibration > Tank level zero value ....................... 22
11.9.3 Home > Data and settings > Implement settings
> Device calibration > Tank profile calibration .................... 23
11.9.4 Home > data and settings > implement settings
> Device calibration > Save tank profile............................. 24
11.9.5 Home > data and settings > implement settings
> Device calibration > Load tank profile............................. 24
11.10 Home > data and settings > implement settings
> Implement geometry...................................................25
11.11 Home > Data and settings > Implement settings
> System configurations.................................................26
11.12 Home > Data and settings > Implement settings
> Rate controller ............................................................26
11.13 Home > Data and settings > Implement settings
> Flowmeter presets ......................................................27
11.14 Home > Data and settings > Implement settings
> Fan..............................................................................27
12 Data and Settings ...................................................................28
12.1 Home > Data and settings > Manage presets................28
12.1.1 Preset setting...................................................................... 28
12.1.2 Preset activation ................................................................. 28
12.1.3 Home > Data and settings > Manage presets
> Totals - Averages.............................................................. 28
12.2 Home > Data and settings > Job parameters ................29
12.3 Home > Data and settings > Info and alarms ................30
12.4 Home > Data and settings > Implement settings ...........31
12.5 Home > Data and settings > Job data............................31
12.6 Home > Data and settings > Sprayer capability.............31
12.7 Home > Data and settings > System status...................32
12.7.1 Home > Data and settings > System status
> Device status................................................................... 32
12.7.2 Home > Data and settings > System status
> ISOBUS........................................................................... 33
12.7.3 Home > Data and settings > System status
> Auxiliary input status........................................................ 34
12.7.4 Home > Data and settings > System status
> System settings ............................................................... 35
12.7.5 Home > Data and settings > System status
> Registration ..................................................................... 38
12.8 Home > Data and settings > User preferences..............39
13 Use...........................................................................................40
13.1 “HOME” main screen .....................................................40
14 Job functions ..........................................................................41
14.1 Output temporary increase and decrease - Home >
Change target rate.........................................................41
14.2 Home > Alarms ..............................................................41
14.3 Home > Automatic functions..........................................42
14.3.1 Home > Automatic functions > Application rate regulation 42
14.3.2 Home > Automatic functions > Simulated speed............... 43
14.3.3 Home > Automatic functions > Light switches ................... 43
14.4 Home > Tank..................................................................44
14.4.1 Level reset .......................................................................... 44
14.4.2 Filled quantity manual setup .............................................. 45
14.4.3 Tank level manual setting.................................................... 45
14.4.4 Tank filling ........................................................................... 45
14.5 Main control and section management..........................46
14.5.1 Control settings WITH Auxiliary Input.................................. 46
14.5.2 Control settings WITHOUT Auxiliary Input .......................... 46
14.6 Joystick: ARAG default functions ...................................49
14.7 Fans...............................................................................50
14.7.1 Fan control / Fan speed temporary increase and decrease -
Home > Fan operation........................................................ 50
14.7.2 Home > Fan exchange ....................................................... 50
15 Maintenance / diagnostics / repairs......................................51
15.1 Cleaning rules................................................................51
15.2 LED status key...............................................................51
15.3 Error messages .............................................................52
15.4 Troubleshooting..............................................................53
16 Technical data.........................................................................54
16.1 Electrical features ..........................................................54
16.2 Environmental features ..................................................54
16.3 Physical features............................................................54
16.4 Pin-out of IBX100...........................................................54
17 End-of-life disposal ................................................................55
18 Guarantee terms .....................................................................55
19 EU declaration of conformity.................................................55