Arjo AtmosAir Velaris User manual

INSTRUCTIONS FOR USE
AtmosAir Velaris
Hybrid mattress system
04.AAV.00EN_05 • 2024-01

2
Design Policy and Copyright
® and ™ are trademarks belonging to the Arjo group of companies.
© Arjo 2024.
As our policy is one of continuous improvement, we reserve the right to modify designs without prior notice.
The content of this publication may not be copied either whole or in part without the consent of Arjo.
WARNING
To avoid injury, always read this Instructions for use and accompanied documents
before using the product.

3
Contents
Foreword...............................................................................5
Intendeduse............................................................................6
Safety instructions .......................................................................8
Preparation ............................................................................10
Partsdesignation.......................................................................11
Alternating pressure pump .................................................................11
Control panel............................................................................11
Standard and Plus mattress ................................................................12
Plus Flex mattress with bolsters .............................................................13
Stretcher(ST)mattress ...................................................................14
Seat cushion ............................................................................15
Controlpanel...........................................................................16
Run/Standby button and light ...............................................................16
Lock button and light......................................................................16
$XGLRRႇOLJKW ...........................................................................16
Weight select buttons and lights ............................................................16
Audio alarm pause button and light ..........................................................17
System fault light.........................................................................17
Low pressure light........................................................................17
Skin IQ light.............................................................................17
Product description - Alternating pressure pump ............................................18
Repeater light ...........................................................................18
Hanging brackets ........................................................................18
Power cable ............................................................................18
Day/Night mode .........................................................................18
SkinIQport.............................................................................18
$XGLRRQRႇVZLWFK .......................................................................18
Product description - Mattresses and seat cushion ..........................................19
All mattress variants ......................................................................19
Standard and Plus mattress variants .........................................................19
Plus Flex mattress with bolsters .............................................................20
Seat cushion ............................................................................20
Reactive and active therapy ..............................................................21
Reactive therapy.........................................................................21
Activetherapy...........................................................................21
System start-up .......................................................................21
Assemble the hybrid mattress system .....................................................22
Assemble the Standard and Plus mattress ....................................................22
Assemble the pump ....................................................................22
Assemble the Plus Flex mattress with bolsters ..............................................24
Transportmode.......................................................................26

4
Dissassemble the hybrid mattress system ..................................................27
7XUQRႇDQGGLVFRQQHFWWKHSXPS ...........................................................27
Disassemble the Plus Flex ................................................................27
Storethepump..........................................................................28
Assemble the Stretcher (ST) mattress ......................................................29
Assemble the Seat cushion...............................................................30
Homecare use ..........................................................................31
Cleaning and disinfection ................................................................32
Care and preventive maintenance .........................................................36
Troubleshooting and alarms ..............................................................38
7HFKQLFDOVSHFL¿FDWLRQV .................................................................39
Labels ................................................................................43
Electromagnetic compatibility ............................................................47

5FOREWORD 5FOREWORD
Foreword
Thank you for choosing the AtmosAir Velaris®hybrid mattress system.
Customer contact information
For questions regarding this product, supplies, maintenance, or other Arjo products and services,
contact Arjo, an Arjo authorised representative or visit www.arjo.com.
Read and fully understand this IFU before using the product
The information in these Instructions For Use (IFU) is necessary for the proper operation and
maintenance of your device. It will help to protect your product and make sure that it performs to your
satisfaction. The information in this IFU is important for your safety. You must read and understand the
,)8WRKHOSSUHYHQWSRVVLEOHLQMXU\8QDXWKRULVHGPRGL¿FDWLRQVRQDQ\$UMRGHYLFHFDQDႇHFWLWVVDIHW\
and performance. Arjo cannot be held responsible for any accidents or incidents resulting from such
PRGL¿FDWLRQVWRLWVSURGXFWV
Service and support
Routine maintenance before every use or every week (in long-term care) is necessary to maintain
the safety and reliability of the product. See the Care and preventive maintenance section for more
information. If you require further information or spare parts, see Customer contact information.
Serious incident
,IDVHULRXVLQFLGHQWRFFXUVLQUHODWLRQWRWKLVPHGLFDOGHYLFHDႇHFWLQJWKHXVHURUWKHSDWLHQWWKHQWKH
user or patient should report the serious incident to the medical device manufacturer or the distributor.
In the European Union, the user should also report the serious incident to the Competent Authority in
the member state where they are located.
'H¿QLWLRQVLQWKLV,)8
WARNING
CAUTION
NOTE
Warning means: Safety warning. Failure to understand
and obey this warning may result in injury to you or
others.
Caution means: Failure to follow these instructions
may cause damage to all or parts of the system or
device.
Note means: This is important information for the
correct use of this system or device.

6 INTENDED USE6 INTENDED USE
Intended use
The AtmosAir Velaris hybrid mattress system is intended for use by caregivers1in acute care,
long-term care and home care facilities, including private homes.
The hybrid mattress system is indicated for the prevention and management of pressure injuries. It
should be used as part of an individualised, comprehensive pressure injury protocol. This typically
includes: repositioning, nutritional support and skin care. The surface should be selected based on full
assessment of the patient needs.
The hybrid mattress system represents one aspect of a pressure injury management protocol. All other
aspects of care should be considered by the healthcare professional.
If existing wounds do not improve, or the patient’s condition changes the overall therapy regimen
should be reviewed by the healthcare professional.
As guidance the system when used in a non-powered reactive mode is indicated for patients that are
deemed to be ‘At Risk’ of a pressure injury. If the system is used in conjunction with the pump, the
SDWLHQWVZLWKDµKLJKHUULVNSUR¿OH¶PD\EHFRQVLGHUHG2
The Velaris Standard mattress, Plus and Plus Flex can all be used in conjunction with the Velaris pump
in order to step up therapy from reactive to active.
The Velaris Stretcher and Seat cushion are reactive only and cannot be used in conjunction with the
Velaris pump.
The above are guidelines only and should not replace clinical judgement.
The Standard mattress system is for patients within the weight range of 40 kg (90 lb) to 250 kg (550 lb).
Heavier patients weighing up to 454 kg (1000 lb) should use the Plus or Plus Flex (bariatric) mattress
system.
7KHK\EULGPDWWUHVVV\VWHPVKRXOGRQO\EHXVHGIRUWKHSXUSRVHVSHFL¿HGLQWKLV,QVWUXFWLRQVIRUXVH
Any other use is prohibited.
1 Caregiver may be a healthcare professional or lay person who operates this medical device.
2 European Pressure Ulcer Advisory Panel, National Pressure Injury Advisory Panel and Pan
3DFL¿F3UHVVXUH,QMXU\$OOLDQFH3UHYHQWLRQDQG7UHDWPHQWRI3UHVVXUH8OFHUV,QMXULHV
&OLQLFDO3UDFWLFH*XLGHOLQH7KH,QWHUQDWLRQDO*XLGHOLQH(PLO\+DHVOHU(G
(38$313,$3333,$&KDSWHU5LVN)DFWRUVDQG5LVN$VVHVVPHQW

7INTENDED USE 7INTENDED USE
Contraindications
In powered active alternating mode with the pump, do not use the hybrid mattress system with patients
with an unstable cervical, thoracic and/or lumbar fracture, cervical traction, and skeletal traction. For
any other conditions that may be complicated by a moving surface, do not use the hybrid mattress
system.
In the non-powered reactive mode without the pump, - It may be possible to use the surface for
patients with unstable cervical, thoracic and/or lumbar fracture, cervical traction, and skeletal traction
if assessed by a healthcare professional as suitable to do so. Ongoing assessment and continuous
monitoring of the patient is advised.
Patient assessment
Facilities should establish regular assessment routines. Caregivers should assess each patient before
using the product. The patient weight must not exceed:
• 250 kg (550 lb) for the Standard mattress
• 454 kg (1000 lb) for the Plus (bariatric) mattress
• 454 kg (1000 lb) for the Plus Flex (bariatric) mattress (with removable bolsters)
• 250 kg (550 lb) for the Stretcher (ST) mattress
• 250 kg (550 lb) for the Seat cushion
If the patient does not meet these criteria an alternative medical device/system shall be used.
Expected service life
The expected service life of the AtmosAir Velaris system elements is:
• Mattress – 5 Years
• Seat Cushion – 5 Years
• Pump – 7 Years
The expected service life of this equipment is subject to preventive maintenance being carried out in
accordance with the instructions for care and maintenance found in this Instructions for use.

8 SAFETY INSTRUCTIONS
Safety instructions
WARNING
To avoid risks of tripping or strangulation,
always use the cable management for the
power cable.
WARNING
To avoid injury, keep the mains power
socket and plug accessible at all times. To
VDIHO\FXWRႇWKHSXPS¶VSRZHUVXSSO\
remove the plug from the mains outlet.
WARNING
To avoid pressure injury, make sure that
the hybrid mattress system is assembled
correctly.
WARNING
To avoid bodily injury, do not use the
mattress or ST mattress as a patient
movement device.
WARNING
To avoid injury and/or unsafe product, do
not use unapproved accessories or attempt
to modify, disassemble or otherwise misuse
the hybrid mattress system.
WARNING
Do not attempt to service or maintain the
pump while it is in use.
WARNING
To avoid falls and injury, make sure that
cables and the tube-set are positioned
correctly. Keep cables away from moving
bed parts or other possible entrapment
areas.
WARNING
To avoid pressure injury the patient must
not wear clothing that may cause areas of
localized high pressure due to creases,
seams, etc. Objects in pockets must be
avoided for the same reason.
WARNING
7RDYRLGUHGXFHGEHQH¿WVIURPWKH
mattress, do not place extra layers between
the patient and the mattress.

9SAFETY INSTRUCTIONS
CPR
CPR can be initiated immediately according to
local protocols (level the bed, disconnect the pump,
lower the side rails).
CAUTION
To avoid damage to the device, do not use
sharp objects or electrical heat under the
blankets on or under the hybrid mattress
system.
CAUTION
To avoid damage, do not expose the device
WRQDNHGÀDPHVVXFKDVFLJDUHWWHV7KLVLV
especially important for the mattress. A leak
in the mattress (Standard and Plus) may
SURSDJDWHWKH¿UH

10 PREPARATION10 PREPARATION
Preparation
Bed frame recommendation
7KHPDWWUHVVUDQJHLVGHVLJQHGWREHXVHGRQ$UMREHGIUDPHV6HH7HFKQLFDOVSHFL¿FDWLRQVRQSDJH
39 of this IFU. The Standard and Stretcher (ST) mattresses may also be used with other bed frames
or trolleys (non-Arjo).
The Plus mattress and Plus Flex mattress with bolsters may only be used with the Arjo Citadel Plus
bed frame.
The clinician or caregiver should assess the needs and determine which mattress and bed frame to
use. See the bed frame IFU for compatible mattress sizes. Find the dimensions of all mattresses in
section Measurements and compatibility on page 40.
$FWLRQVEHIRUH¿UVWXVH
1. Visually check the package for damage. If the package is damaged, contact the transport agency.
Do NOT use the product.
2. Read this IFU.
3. Check that all parts of the product are supplied: Compare to section Parts designation on page
11. If any part is missing or damaged – do NOT use the product.
4. Recycle the packaging according to local regulations.
5. Choose a designated area where this Instructions for Use should be kept and is easily accessible at
all times.
Actions before every use
Inspect the hybrid mattress system according to section Care and preventive maintenance on page
36. If any item is damaged - do NOT use the product.
Action after each patient
Clean and disinfect the product after each patient according to section Cleaning and disinfection on
page 32.

11PARTS DESIGNATION
1
5
4
3
2
6
Control panel
Parts designation
1. Run/Standby button and light
2. Lock button and light
3. Audio OFF light
4. Weight decrease button (-)
5. Weight selected light
6. Weight increase button (+)
7. Power fail light
8. Audio alarm pause button and light
9. Low pressure light
10. System fault light
11. Skin IQ connected light
Skin IQ
AtmosAir Velaris
40 60 80 100 130 170 210 250 350 450 kg
154698
1110
732
1. Control panel (with lights)
2. Repeater light
3. Tube-set connector
4. Hanging brackets
5. Skin IQ port
6. Power cable
Alternating pressure pump

12 PARTS DESIGNATION
1. Detachable top cover
2. Mattress connector
3. Mattress connector cavity
4. Non-Slip strips
5. Detachable bottom cover
6. Handles
7. &RYHUDWWDFKPHQW]LSZLWK]LSÀDS
8. Cable management loops
Standard and Plus mattress
1
7
6
5
2, 3
4
8

13PARTS DESIGNATION
Plus Flex mattress with bolsters
1. Left side bolster
2. Mattress connector
3. Mattress connector cavity
4. Foot bolster
5. Mattress
6. Buckles (four on each side)
7. Right side bolster
8. &RYHUDWWDFKPHQW]LSZLWK]LSÀDS
9. Non-Slip strips
10. Cable management loops
11. Handles (two on each bolster)
12. Buckles (four on each bolster)
13. Side bolster retaining straps (two at the head end,
two at the foot end)
1
2, 3
4
11
6
12
5
7
8
10
13
9

14 PARTS DESIGNATION
1
5
4
3
2
1. Detachable top cover
2. Non-Slip strips
3. Detachable bottom cover
4. &RYHUDWWDFKPHQW]LSZLWK]LSÀDS
5. Handles
Stretcher (ST) mattress

15PARTS DESIGNATION
1. Detachable top cover
2. &RYHUDWWDFKPHQW]LSZLWK]LSÀDS
3. Non-Slip strip
4. Detachable bottom cover
5. Handle (on the back)
Seat cushion
1
5
4
2
3

16 CONTROL PANEL
Control panel
Run/Standby button and light
The Run/Standby button switches the pump
between Run mode and Standby mode.
In Run mode the light is on.
For Standby mode, press and hold the button for
WZRVHFRQGV7KHOLJKWWXUQVRႇ
Lock button and light
To lock the control panel, press and hold the Lock
button for two seconds. When locked the light turns
on.
To unlock all control panel buttons, press and hold
the Lock button for two seconds. When unlocked
WKHOLJKWWXUQVRႇ
The control panel buttons automatically lock after
60 seconds if no control panel button is pressed.
$XGLRRႇOLJKW
7KH$XGLRRႇOLJKWWXUQVRQZKHQWKH$XGLR
QRWL¿FDWLRQVDQGDODUPVKDYHEHHQSHUPDQHQWO\
disabled.
6HH$XGLRRQRႇVZLWFKRQSDJH
Weight select buttons and lights
40 60 80 100 130 170 210 250 350 450
kg
The default weight is set and the light is on at 100
kg (220 lb).
• Press the - button to reduce the patient weight.
Minimum value is 40 kg (90 lb).
• Press the + button to increase the patient
weight. Maximum value is 450 kg (1000 lb).
For each button press the weight reduces/
increases by one step.
The selected weight is indicated by a green light.
The Plus mattress weight settings (350 kg and 450
kg) are indicated by a blue light when selected.
Always round up the patient’s weight to the next
higher value.

17CONTROL PANEL
Audio alarm pause button and light
Press the Audio alarm pause button to silence the
audible alarm for 15 minutes. The light turns on.
Press the button again to cancel the alarm pause.
Power fail light
If a power failure is detected the power failure light
turns on and an alarm sounds.
Active (alternating) therapy is not possible during
power failure conditions.
NOTE
7RWXUQWKHSXPSRႇDQGFDQFHOWKHDODUP
during a power outage, press and hold the
run/standby button for two seconds.
System fault light
If an internal fault of the pump is detected during
Built-In Self-Test (BIST) or during therapy, the
system fault light turns on and an alarm sounds
Low pressure light
If the mattress fails to achieve the target pressure,
the low pressure light turns on and an alarm
sounds.
Skin IQ light
Skin IQ
The Skin-IQ light turns on when a Skin-IQ coverlet
is connected to the Skin IQ power outlet port.

18 PRODUCT DESCRIPTION - ALTERNATING PRESSURE PUMP
Product description - Alternating pressure pump
Repeater light
AtmosAir Velaris
40 60 80 100 130 170 210 250 350 454
kg
During normal operation the repeater light is on and
green. During a fault condition, the repeater light
will turn yellow.
Hanging brackets
Use the hanging brackets to mount the pump at the
foot end of the bed.
7KHSXPSFDQDOVREHSODFHGRQDÀDWVXUIDFHQHDU
the bed and the mattress connector.
Power cable
40 60 80100 130 170210250350 454
kg
Position the power cable in the cable management
loops on the left side of the mattress.
See Cable management loops on page 19.
Day/Night mode
A light sensor automatically reduces the brightness
of the pump lights in low ambient light.
Skin IQ port
Only use the Skin IQ port with the Skin IQ power
cable to provide power to the Skin IQ coverlet.
See Allowed combinations on page 40.
For instructions on how to use Skin IQ, see the
Skin IQ IFU.
$XGLRRQRႇVZLWFK
A
B
7KH$XGLRRQRႇVZLWFKGLVDEOHVDOOSXPSVRXQG
QRWL¿FDWLRQV8VHLWZKHQLWKDVEHHQGHWHUPLQHG
that audio output could be disturbing for the patient.
7KH$XGLRRQRႇVZLWFKLVORFDWHGXQGHUQHDWKWKH
side panel cover. The cover can only be removed
by a service technician.
Set the switch to position A to disable all audio
output. Set the switch to position B to enable all
audio output.
NOTE
7KH$XGLRRQRႇVZLWFKVKRXOGRQO\EH
XVHGE\TXDOL¿HGSHUVRQQHOXQGHUGLUHFWLRQ
of the responsible organisation.

19PRODUCT DESCRIPTION - MATTRESSES AND SEAT CUSHION
All mattress variants
Handles
To move the mattress use the four handles on the
bottom mattress cover.
Non-slip base
Non-slip strips integrated in the bottom cover
prevent the mattress from slipping on the bed
frame.
WARNING
To avoid bodily injury, never use the
mattress or ST mattress as a patient
movement device.
Product description - Mattresses and seat cushion
Standard and Plus mattress variants
Covers
The mattress top and bottom welded covers are
co-joined by a zip.
Cable management loops
SkinIQ
AtmosAir Velaris
406080100130170210 250 350454
kg
The cable management loops are used to
secure the pump power cable to avoid falling or
entanglement.
Mattress connector
The mattress connector is used to connect the
mattress to the pump. The mattress connector is
located at the foot end of the mattress.

20 PRODUCT DESCRIPTION - MATTRESSES AND SEAT CUSHION
Plus Flex mattress with bolsters
Covers
The Plus Flex mattress and bolster bottom covers
are sewn, the top covers are welded and co-joined
by a zip.
Handles
To move the mattress use the four handles on the
bottom mattress cover.
To move a bolster use the two handles on the
bottom bolster cover.
Buckles
The buckles are used to connect the side bolsters
to the mattress. There are four buckles on each
side of the mattress and corresponding buckles on
the side bolsters.
Side bolster retaining straps
The side bolster retaining straps are used to
connect the side bolsters to the mattress.
Seat cushion
Handle
To move the seat cushion use the handle on the
back.
Non-slip base
The non-slip strip integrated in the bottom cover
prevents the cushion from slipping on the chair.
Other manuals for AtmosAir Velaris
3
Table of contents
Other Arjo Indoor Furnishing manuals

Arjo
Arjo ConformX User manual

Arjo
Arjo ConformX User manual

Arjo
Arjo Pentaflex Series User manual

Arjo
Arjo Pentaflex User manual

Arjo
Arjo Prioma OBT4 User manual

Arjo
Arjo ConformX User manual

Arjo
Arjo Prioma User manual

Arjo
Arjo Pentaflex MR Acute User manual

Arjo
Arjo AtmosAir 9000A User manual

Arjo
Arjo AtmosAir Fit User manual
Popular Indoor Furnishing manuals by other brands

Regency
Regency LWMS3015 Assembly instructions

Furniture of America
Furniture of America CM7751C Assembly instructions

Safavieh Furniture
Safavieh Furniture Estella CNS5731 manual

PLACES OF STYLE
PLACES OF STYLE Ovalfuss Assembly instruction

Trasman
Trasman 1138 Bo1 Assembly manual

Costway
Costway JV10856 manual