manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ASCOM
  6. •
  7. Transmitter
  8. •
  9. ASCOM HMT 1000 User manual

ASCOM HMT 1000 User manual

Other ASCOM Transmitter manuals

ASCOM A51 - User manual

ASCOM

ASCOM A51 - User manual

ASCOM A51 - User manual

ASCOM

ASCOM A51 - User manual

ASCOM H952T User manual

ASCOM

ASCOM H952T User manual

ASCOM 9dLD User manual

ASCOM

ASCOM 9dLD User manual

ASCOM A51 - User manual

ASCOM

ASCOM A51 - User manual

ASCOM T942C User manual

ASCOM

ASCOM T942C User manual

ASCOM HMT1000 - DATASHEET 1 User manual

ASCOM

ASCOM HMT1000 - DATASHEET 1 User manual

ASCOM 9DLD - DATASHEET 1 User manual

ASCOM

ASCOM 9DLD - DATASHEET 1 User manual

ASCOM TELEPROTECT U971 User manual

ASCOM

ASCOM TELEPROTECT U971 User manual

ASCOM TELECARE WP - BROCHURE 1 User manual

ASCOM

ASCOM TELECARE WP - BROCHURE 1 User manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PRODUCT SHEET
Product: HMT 1000
Segment: Defense
Division: Security Communication
The Hybrid Mains and Optical Transmission
Unit is an ancillary product to Ascom’s palette of
military communication equipment. It is a
practical device that fulfils a special but common
requirement. The HMT 1000 feeds isolated
stations with signal and power through a single
hybrid cable. It offers fast set-up, effectively
replaces power generators and can be deployed
by a single person.
Reduced emission as well as distantly
placed transmitters give personnel an element
of added protected in the combat arena.
Compliant with standards for military grade
electronics, the HTM 1000 is constructed of the
same quality standards as the family of Ascom
ruggedized openAccess Nodes. Used primarily in
military environments, it is also suitable for
international peace keeping and crisis manage-
ment operations.
The HTM 1000 delivers power and provides for remote operation of
semi-permanent transmitter stations or other C4I equipment. Simplified
cabling allows a small signal core team to rapidly install - for example -
ad-hoc surveillance stations, command centres, transmitter stations and
check points even in difficult access sites such as snow and steep terrain.
The HTM 1000 hybrid cable consists of a power transmission line and
four single-mode optical fibres bundled in a sturdy, yet compact and light
construction; complete with integrated terminal hybrid connectors that let
fast fail-safe mounting.
The unit boasts a high capacity data transmission rate for supporting
remote data networks and is provisioned with safety monitoring including
passive and active protection of the mains transmission line and provides
galvanically isolated operation.
The watertight ultra rugged enclosure is hermetically sealed to
withstand severe humidity, dust exposure and extreme temperatures. It is
corrosion resistant and shock/vibration protected.
Typical HMT1000 configuration: Ad-hoc connection between a mobile command unit
(‘supply side’) and a remote operation unit (‘remote side’).
Hybrid cable
230 VAC
230 VAC
HMT
1000
HMT
1000
PC
PC
PC
FO connector
Hybrid connector
FO cable FO cable
Mobile command unitRemote operation unit
HMT 1000 HYBRID MAINS AND OPTICAL
TRANSMISSION UNIT 1000 FOR REMOTE
OPERATION OF C4I INFRASTRUCTURE
PRODUCT SHEET: HMT 1000
Although the information in this publication is represented in good faith and believed to be correct, Ascom makes no representations or warranties
as to the completeness or accuracy of the information. In no event will be Ascom responsible for damages of any nature whatsover resulting from the
use of or reliance upon the information contained in this document. Such information is subject to change without notice. Ascom gives no warranty
and makes no representation that any of its products contained in this document are designed for any particular use or purpose. The graphics and
contents of this document are the copyrighted work of Ascom and contain proprietary trademarks and tradenames of Ascom.
08.2010 © Ascom (Switzerland) Ltd.
Technical Specification
Mechanical data
Size (LxHxD)/mm 280x280x258
Weight approx. 25.5 kg
Power supply
Input voltage 230 VAC/50 Hz ± 10%
Output voltage 230 VAC/50 Hz ± 10% (regulated)
Max. output power 1 kVA
Max. transmission
length 3 km
Environment
Operation temperature -20... +55 °C MIL-STD-810F, 502.4, procedure II, 501.4,
procedure II
Storage temperature -30... +60 °C MIL-STD-810F, 502.4,
procedure I, 501.4, procedure I
Relative humidity
(closed interfaces) 95% MIL-STD-810E, 507.3, procedure I, cycle 3
Waterproof IP65
Shock (device in trans-
port case)
MIL-STD-810F, method 516.5, procedure I, impulse (20
g, 11ms, sawtooth)
Vibration (device in
transport case)
MIL-STD-810F, method 514.5 (1.04 g RMS according to
514.5C-1, 5 - 500 Hz)
External I/O
Optical connectors FO-4 (4 x single-mode FO, 1310 nm); HMT1000 to
exernal device
Hybride connector 1 x pair copper, 4 x single-mode FO
(1310 nm; HMT1000 to HMT1000)
EOW Microtel connection
Control 1x RS232, 1x 10base-T
230 VAC In Binder plug, series 693, 7pol pin
230 VAC Out Binder plug, series 693, 7pol socket
User Interface
230 VAC switch On/Off
EOW call Hook on/off button and
indicator
Status indication
LEDs for
Status 230 VAC
link
local error
remote error
overload
Protection
Isolation to ground 3 kVAC
Power Transmission Mains power transmission galvanically isolated and
monitored with supervision signal
Overload protection Electronic protection circuit
Approvals
EMC emissions MIL-STD 461E
EMC immunity
MIL-STD 461E
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-6-2
Transpor t
Case Stocks absorbing carrying case
Ascom (Switzerland) Ltd.
Belpstrasse 37
CH-3000 Berne 14
T + 41 31 999 13 65
F + 41 31 999 16 82
[email protected]
www.ascom.com
Ascom (Austria) Ges.m.b.H
Lemböckgasse 49
1230 Wien
T +43 1 811 77 0
F +43 1 811 77 10
[email protected]
www.ascom.at
Ascom Deutschland GmbH
Edisonstrasse 11 - 13
60388 Frankfurt am Main
T +49 6109 738 584
F +49 6109 738 333
[email protected]
www.ascom.de
Ascom (Finland) Oy
Pakkalankuja 6
FI-01510 Vantaa
T + 358 9 825 901
F + 358 9 825 902 79
info@ascom.fi
www.ascom.fi
Ascom (CZ) s.r.o.
Zemské právo 1199/5
CZ-10200 Praha 10
T + 420 267 219 512
F + 420 267 219 511
[email protected]
www.ascom.cz