Package Contents
1
Requirements
2
3-2 Hardware Review (Front View) Hardware Installation
4
1 PE1108 / PE1208 / PE3108 / PE3208 / PE6108 / PE6208 / PE8108 / PE8208
Power Distribution Unit
1 Power Cord
1 Rack Mount Kit
1. Circuit Breaker Pushbutton
2. Power Sockets
3. Readout Section
4. Power LED
5. LAN Port and LEDs
6. Reset Switch
7. Grounding Terminal
8. Sensor Ports
9. Power Socket
• Browsers accessing the eco PDU unit must support SSL 128 bit encryption.
• For cold booting of attached computers, the computer's BIOS must support Wake on LAN or System after AC
Back.
• For Safe Shutdown:
• The computer must be running Windows (Windows 2000 or higher) or Linux.
• The Safe Shutdown program (available by download from our website or on the software CD included), must
be installed and running on the computer.
Hardware Review
3-1
Rack Mounting
The eco PDU can be mounted in a 19” (1U) rack. To rack mount the device, use the rack mounting brackets that
came with your device. The brackets can be screwed to the front or rear sides of the device, and then the unit can
slide into the front of the rack, as shown in the diagram below:
Installation
To set up your eco PDU installation, refer to the installation diagram (the numbers in the diagram correspond to the
numbered steps), and do the following:
1. Use a grounding wire to ground the eco PDU by connecting one end of the wire to its grounding terminal, and
the other end of the wire to a suitable grounded object.
Note: Do not omit this step. Proper grounding helps to prevent damage to the unit from surges or static
electricity.
2. For each device you want to connect, use its power cable to connect from the device's AC socket to any available
outlet on the eco PDU.
3. Plug the cable that connects the eco PDU to the LAN into the eco PDU's LAN port.
4. If you are using sensors in your eco PDU installation, connect them to the sensor ports on the unit’s front panel.
Note: Sensors are optional.
5. Connect the eco PDU's power cord to an AC power source.
Note: We strongly advise that you do not plug the eco PDU into a multi socket extension cord, since it may not
receive enough amperage to operate correctly.
Once you have finished these installation steps, you can turn on the eco PDU and the connected devices.
Note: We strongly recommend using cable ties and cable bars to safely and securely route the cables attached to the
front of the unit.
eco PDU PE Series PE1108/PE1208/PE3108/
PE3208/PE6108/PE6208/PE8108/PE8208
Power Distribution Unit Quick Start Guide
© Copyright 2012 ATEN®International Co., Ltd. www.aten.com
Altusen and the Altusen logo are trademarks of ATEN International Co., Ltd.
All rights reserved. All other trademarks are the property of their respective owners.
This product is RoHS compliant PAPE-1215-900G Printing Date: 04/2012
All information, documentation, and specifications contained in this media are subject to change without prior notification by the manufacturer.
Please visit our website to find the most up to date version.
PE1108A / PE3108A
PE1208A / PE3208A
PE1108B / PE1108G / PE3108B / PE3108G
PE1208B / PE1208G / PE3208B / PE3208G
PE6108A / PE8108A
PE6208A / PE8208A
PE6108B / PE6108G / PE8108B / PE8108G
PE1108 / PE1208 / PE3108 / PE3208 PE6108 / PE6208 / PE8108 / PE8208
PE6208B / PE6208G / PE8208B / PE8208G
Front View
Rear View
Readout Section
5
1
4
3
2
6
12 3 4 5
6
12 3
4
5
6
12 3 4 5
6
12 3 4 5
6
123
4
5
6
123
4
5
3SELECT
PDU
CURRENT
OUTLET
CURRENT
IP
ADDRESS
SENSOR
1
SENSOR
2
OUTLET STATUS
3SELECT
PDU
CURRENT
OUTLET
CURRENT
IP
ADDRESS
SENSOR
1
SENSOR
2
6
123
4
5
6
12 3 4 5
7 98
1 Software CD
1 User Instructions
Online Registration
International:
• http://support.aten.com
North America:
• http://www.aten-usa.com/product_registration
Technical Phone Support
International:
• 886-2-8692-6959
China:
• 86-10-5255-0110
Japan:
• 81-3-5615-5811
Korea:
• 82-2-467-6789
North America:
• 1-888-999-ATEN Ext: 4988
United Kingdom:
• 44-8-4481-58923
5Operation 6-1 Specification
Specification 6-2
Operation Methods
ALTUSEN eco PDU models provide three methods to access and manage your installation: Browser, IP Installer ,
eco Sensors, and SNMP.
Browser
The eco PDU can be accessed and controlled via any supported Internet browser from any platform.
eco Sensors
The eco PDU supports ALTUSEN eco Sensors (eco PDU Manager Software). ALTUSEN eco Sensors provides you
with an easy method for managing multiple devices, offering an intuitive and user-friendly Graphical User Interface
that allows you to configure a PDU device and monitor power status of the equipment connected to it. ALTUSEN
eco Sensors can be obtained from the Download area of our web site.
SNMP
The eco PDU supports any 3rd party V3 SNMP Manager Software. SNMP Management Information Database
(MIB) files for the eco PDU device can be found on the software CD provided with the eco PDU package.
First Time Setup
Once the eco PDU installation has been cabled up, the Administrator needs to configure the network parameters,
change the default Administrator login settings, and add users. The easiest way to accomplish this is to log in over
the Net with a browser.
Browser Login
The eco PDU can be accessed via a supported Internet browser from any platform.
Note: Browsers must support SSL 128 bit encryption.
To access the eco PDU do the following:
1. Open your browser and specify the IP address of the eco PDU you want to access in the browser's URL location
bar. If you are the administrator and are logging in for first time, use the default IP address of 192.168.0.60.
Note: You must be on the same network segment as the eco PDU to use the default IP address.
2. If a Security Alert dialog box appears, accept the certificate – it can be trusted. The Login page appears:
3. Provide a valid Username and Password (set by the eco PDU administrator), then Click Login to bring up the
browser Main Page.
If you are the administrator and are logging in for the first time, use the default Username: administrator; and the
default Password: password.
Note: For security purpose we recommend purpose we recommend changing them to something unique.
Network Configuration
To set up the network, do the following:
1. Click the Device Management tab.
2. Select Device Configuration on the menu bar. A screen similar to the one below appears:
Changing the Administrator Login
To change the default Administrator username
and password, do the following:
1.Click the User Management tab.
2. In the Administrator Information section,
reset the name and password fields to
something unique, then click Save (at the
bottom of the page.)
Function PE1108A /
PE3108A
PE1208A /
PE3208A
PE1108B /
PE3108B
PE1208B /
PE3208B
PE1108G /
PE3108G
PE1208G /
PE3208G
Power
Outlets Direct 8
Connectors
Power Inlet 1 x IEC 320 C20
Power
Outlets
NEMA 8 x NEMA
5-15R
8 x NEMA
5-20R NA
IEC N/A 8 x IEC 320
C13
7 x IEC 320
C13
(Ports 2–8);
1 x C19
(Port 1)
8 x IEC 320
C13
7 x IEC 320
C13
(Ports 2–8);
1 x C19
(Port 1)
Sensor 2 x RJ-11
LAN 1 x RJ-45 (Female)
LEDs
Outlet Status N/A
Selection 1-digit 7-segment (Orange)
PDU Current /
Outlet Current /
IP Address
3 (Green)
Current / IP
Address 3-digit 7-segment (Orange)
Power 1 (Blue)
LAN
10/100M 1 (Orange / Green)
Link 1 (Green)
Sensor 2 (Green)
Switches
Reset 1 x Semi-recessed Pushbutton
Power 1 x Non-fuse Breaker
I/P Rating
100–
120V~;
50/60Hz;
12A
100–
120V~;
50/60Hz;
16A
100–
240V~;
50/60Hz;
12A
100–
240V~;
50/60Hz;
16A
100–
240V~;
50/60Hz;
10A
100–
240V~;
50/60Hz;
16A
Load Capacity 1440W 1920W 2880W 3840W 2400W 3840W
O/P Rating
Per Port
100–
120V~;
50/60Hz;
12A
100–
120V~;
50/60Hz;
16A
100-240V~;
50/60Hz,
12A
Port2-8:
100-240V~;
50/60Hz,
12A 100-240V;
50/60Hz,
10A
Port2-8:
100-240V;
50/60Hz,
10A
Port1:
100–
240V~;
50/60Hz;
16A
Port1:
100–
240V~;
50/60Hz;
16A
Total
100–
120V~;
50/60Hz;
12A
100–
120V~;
50/60Hz;
16A
100-240V~;
50/60Hz,
12A
100-240V~;
50/60Hz,
16A
100-240V~;
50/60Hz,
10A
100-240V~;
50/60Hz,
16A
Environment
Operating
Temperature 0–50˚C
Storage
Temperature -20–60˚C
Humidity 0–80% RH Non-condensing
Physical
Properties
Housing Metal
Weight 2.63Kg /
2.68Kg
2.64Kg /
2.69Kg
2.70 kg /
2.73 kg
2.71 kg /
2.74 kg
2.70 kg /
2.72 kg
2.71 kg /
2.74 kg
Dimensions
(L x W x H) 43.24 x 21.93 x 4.40 cm
Function PE6108A /
PE8108A
PE6208A /
PE8208A
PE6108B /
PE8108B
PE6208B/
PE8208B
PE6108G /
PE8108G
PE6208G/
PE8208G
Power
Outlets Direct 8
Connectors
Power Inlet 1 x IEC 320 C20
Power
Outlets
NEMA 8 x NEMA
5-15R
8 x NEMA
5-20R N/A
IEC N/A 8 x IEC 320
C13
7 xIEC 320
C13
(Ports 2–8);
1 x C19
(Port 1)
8 x IEC
320 C13
7 x IEC
320 C13
(Ports 2–8);
1 x C19
(Port 1)
Sensor 2 x RJ-11
LAN 1 x RJ-45 (Female)
LEDs
Outlet Status 8 (Orange)
Selection 1-digit 7-segment (Orange)
PDU Current /
Outlet Current /
IP Address
3 (Green)
Current / IP
Address 3-digit 7-segment (Orange)
Power 1 (Blue)
LAN 10/100M 1 (Orange / Green)
Link 1 (Green)
Sensor 2 (Green)
Switches Reset 1 x Semi-recessed Pushbutton
Power 1 x Non-fuse Breaker
I/P Rating
100–
120V~;
50/60Hz;
12A
100–120V~;
50/60Hz;
16A
100–240V~;
50/60Hz;
12A
100–
240V~;
50/60Hz;
16A
100–
240V~;
50/60Hz;
10A
100–
240V~;
50/60Hz;
16A
Load Capacity 1440W 1920W 2880W 3840W 2400W 3840W
O/P Rating
Per Port
100–
120V~;
50/60Hz;
12A
100–120V~;
50/60Hz;
16A
100-240V~;
50/60Hz,
12A
Port2-8:
100-
240V~;
50/60Hz,
12A 100-
240V~;
50/60Hz,
10A
Port2-8:
100-
240V~;
50/60Hz,
10A
Port1:
100-
240V~;
50/60Hz,
16A
Port1:
100-
240V~;
50/60Hz,
16A
Total
100–
120V~;
50/60Hz;
12A
100–120V~;
50/60Hz;
16A
100-240V~;
50/60Hz,
12A
100-
240V~;
50/60Hz,
16A
100-
240V~;
50/60Hz,
10A
100-
240V~;
50/60Hz,
16A
Environment
Operating
Temperature 0–50˚C
Storage
Temperature -20–60˚C
Humidity 0–80% RH Non-condensing
Physical
Properties
Housing Metal
Weight 2.77 kg /
2.80 kg
2.77 kg /
2.82 kg
2.82 kg /
2.87 kg
2.79 kg /
2.87 kg
2.82 kg /
2.87 kg
2.79 kg /
2.87 kg
Dimensions
(L x W x H) 43.24 x 21.93 x 4.40 cm

This manual suits for next models

6

Other ATEN Power Distribution Unit manuals

ATEN Altuscn PN5212 User manual

ATEN

ATEN Altuscn PN5212 User manual

ATEN Altuscn PN5212 User manual

ATEN

ATEN Altuscn PN5212 User manual

ATEN ALTUSEN PE6108 User manual

ATEN

ATEN ALTUSEN PE6108 User manual

ATEN PE7216r User manual

ATEN

ATEN PE7216r User manual

ATEN PE5340SL User manual

ATEN

ATEN PE5340SL User manual

ATEN PE5220s User manual

ATEN

ATEN PE5220s User manual

ATEN Altusen PN7212 User manual

ATEN

ATEN Altusen PN7212 User manual

ATEN PE5216 User manual

ATEN

ATEN PE5216 User manual

ATEN NRGence PE Series User manual

ATEN

ATEN NRGence PE Series User manual

ATEN NRGence PE5108 User manual

ATEN

ATEN NRGence PE5108 User manual

ATEN PE Series User manual

ATEN

ATEN PE Series User manual

ATEN eco PDU PE7214 User manual

ATEN

ATEN eco PDU PE7214 User manual

ATEN PG98230 Series User manual

ATEN

ATEN PG98230 Series User manual

ATEN PE4104G User manual

ATEN

ATEN PE4104G User manual

ATEN PE7216 User manual

ATEN

ATEN PE7216 User manual

ATEN NRGence PE5-8108 User manual

ATEN

ATEN NRGence PE5-8108 User manual

ATEN PE1107mZ User manual

ATEN

ATEN PE1107mZ User manual

ATEN NRGence PE5108 User manual

ATEN

ATEN NRGence PE5108 User manual

ATEN eco PDU PE Series User manual

ATEN

ATEN eco PDU PE Series User manual

ATEN PG Series User manual

ATEN

ATEN PG Series User manual

ATEN PE1216 User manual

ATEN

ATEN PE1216 User manual

ATEN eco PDU PE5216 User manual

ATEN

ATEN eco PDU PE5216 User manual

ATEN PE7216 User manual

ATEN

ATEN PE7216 User manual

ATEN NRGence PE5-8108 User manual

ATEN

ATEN NRGence PE5-8108 User manual

Popular Power Distribution Unit manuals by other brands

Alpha Technologies Cordex HP 48 1.2kW Technical guide

Alpha Technologies

Alpha Technologies Cordex HP 48 1.2kW Technical guide

Oh!FX TC-107 Quick user guide

Oh!FX

Oh!FX TC-107 Quick user guide

Rowe PDM60 instruction manual

Rowe

Rowe PDM60 instruction manual

Victron energy Smart BatteryProtect 12/24V manual

Victron energy

Victron energy Smart BatteryProtect 12/24V manual

Flintec KAEX-4 Technical manual

Flintec

Flintec KAEX-4 Technical manual

Tektronix ECO8000 Series user manual

Tektronix

Tektronix ECO8000 Series user manual

ERICO TDS150-1SR Series instruction sheet

ERICO

ERICO TDS150-1SR Series instruction sheet

Dell Metered Rack Power Distribution Unit user guide

Dell

Dell Metered Rack Power Distribution Unit user guide

lab12 Gordian owner's manual

lab12

lab12 Gordian owner's manual

Tripp Lite PDU10K owner's manual

Tripp Lite

Tripp Lite PDU10K owner's manual

Black Box ACR1000-CPH8R-R2 user guide

Black Box

Black Box ACR1000-CPH8R-R2 user guide

Zero88 RigSwitch manual

Zero88

Zero88 RigSwitch manual

Phase3 Powersafe PS5-E-88 Assembly guide

Phase3

Phase3 Powersafe PS5-E-88 Assembly guide

Black Box PS186A manual

Black Box

Black Box PS186A manual

Tripp Lite PDUMH15AT owner's manual

Tripp Lite

Tripp Lite PDUMH15AT owner's manual

Tripp Lite PDU1215 Technical application bulletin

Tripp Lite

Tripp Lite PDU1215 Technical application bulletin

BigDog MAVbase PR-W3PI manual

BigDog

BigDog MAVbase PR-W3PI manual

Tripp Lite PDUMV30HVNET Specification sheet

Tripp Lite

Tripp Lite PDUMV30HVNET Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.