Axiom SW121HLA User manual

USER MANUAL
SW121HLA
KEY FEATURES
INTRODUCTION
TECHNICAL SPECIFICATION
Acouscal
Mechanical
Electrical
* Nominal consumpon is measured with pink noise with a crest factor of 12
dB, this can be considered a standard music program.

MECHANICAL DRAWING
OPTIONAL ACCESSORIES
NAC3FXW Note:
See assembly instrucon downloadable from NEUTRIK WEB site at: hp://
www.neutrik.com/
NAC3MXW
HTAC
CAT5SLU01/05/10
AR100LUxx
AR200LUxx
AVCAT5PROxx
NE8MCB
NC3MXXBAG
NC3FXXBAG
USB2CAN
USB2CAND
see hp://www.axiomproaudio.com/ for detailed descripon and other available accessories.
SPARE PARTS
AC103GS 91DA4000
AC115DN 91PCAGLED1
98EDG21SW8 91PCAG00031
NAC3PX 91DSPKT3
SCNACPX 91CRAX2010
99SWRT121SV 95SW121PLS2
80.1 cm
31.5"
58.9 cm
23.2"
102.2 cm
40.2"
112.2 cm
44.2"
NOTE: This product is designed to work on floor and is not equipped with rigging flying points, do not suspend the loudspeakers from the handle.

POWER INPUT
MAINS~ IN -
MAINS~ OUT -
WARNING! Connect no more than one subwoofer unit to the MAINS~ OUT
connector.
WARNING! If you use the MAINS~ OUT turn on each subwoofer unit one a me.
WARNING! In the case of product failure or fuse replacement, disconnect the unit
completely from the mains power.
WARNING! Use a suitable power cable and mains plug to build the power cable, it
must only be connected to a socket corresponding to the specicaons indicated
on the amplier unit.
See assembly instrucon downloadable from NEUTRIK WEB site at: hp://www.
neutrik.com/
CONTROL PANEL
ON -
PROT -
SIGN LIMIT -
INPUT -
LINK -
GND LIFT -
PRESET BUTTON -
1)
ID ASSIGN
2)
STANDARD
INFRA
CARDIOID
USER
.
NETWORK IN/OUT -
TERMINATE -

POWER AMPLIFIER
SIGNAL PROCESSING
PRONET
Download the PRONET app from the AXIOM website at hp://www.axiomproaudio.com/ clicking on downloads secon of the product.
Assign the ID number
1.
2.
3.
4.
5.
For more detailed instrucon about PRONET see the PRONET USER’S MANUAL included with the soware.
+15
+10
+5
0
-5
-10
-15
-20
-25
-30
-35 20 50 100 200 500 1K 2K 5K 10K 20K Hz
SW121HLA - PRESET RESPONSE
INFRA STANDARD

Useful tools to set up properly a vercal array system using the SW121HLA subwoofer
CABLE TESTER
INCLINOMETER WITH LEVER
LASER DISTANCE METER
SMAART or similar acousc measurement system
do not
pressed
pressed
last device
network
network
AX2010A
USB2CAN
PC NOTEBOOK
USB 2.0 port
STATUS
CONVERTER
USB2CAN
CODE:
S/N:
RATINGS:
RoHS COMPLIANT
MADE IN ITALY
USB2CAN
00001
5V --- 200mA
EXAMPLE OF PRONET NETWORK WITH AX2010A AND SW121HLA

CARDIOID PRESET
NOTES:
When placing the cardioid array keep a distance to walls or other obstacles of at least 80 cm (2.7 ) in order not to aect the radiaon of the
reversed cabinet.
When placing mulple cardioid arrays keep a distance between them of at least 120 cm (3.9 ) in order not to maximize the combined radiaon
of whole arrays.
80 cm min.
2.7 min.
120 cm min.
3.9 min.
80 cm min.
2.7 min.
stage
wall or other
big ostacle
bass sum direcon
bass cancellaon direcon
audience floor

NOTES:
When placing the cardioid array keep a distance to walls or other obstacles of at least 80 cm (2.6 ) in order not to aect the radiaon of the
reversed cabinet.
When placing mulple cardioid arrays keep a distance between them of at least 80 cm (2.6 ) in order not to maximize the combined radiaon
of whole arrays.
stage
wall or other
big ostacle
bass sum direcon
bass cancellaon direcon
audience floor
80 cm min.
2.7 min. 80 cm min.
2.7 min.
80 cm min.
2.7 min.

LIMITED WARRANTY
SAFETY INSTRUCTIONS
CE CONFORMITY
PROEL S.p.A. (World Headquarter) - Via alla Ruenia 37/43 - 64027 Sant’Omero (Te) - ITALY
Tel: +39 0861 81241 Fax: +39 0861 887862 www.axiomproaudio.comwww.axiomproaudio.com
Table of contents
Other Axiom Subwoofer manuals

Axiom
Axiom SW215AV2 User manual

Axiom
Axiom SW2100AV2 User manual

Axiom
Axiom SW210P User manual

Axiom
Axiom EP175 v4 User manual

Axiom
Axiom EP800 v3 User manual

Axiom
Axiom SW215P User manual

Axiom
Axiom SW18AV2 User manual

Axiom
Axiom EP350 User manual

Axiom
Axiom SW1800A User manual

Axiom
Axiom SW218XP User manual