AXISExSeries
Versionhistory
VersionDateDetails
1.02021-09-17Firstrelease
2.02022-01-10Addedmininginormation
4

AXISExSeries
Models
TheAXISExcameraserieshasourmodels:twotypeswithPTZhousingsandtwotypeswithxed
housings,eachwithvisualimagingoptionsandthermalimagingoptions.Thevisualcameras
includeawiper.
TypeHousingDetails
P21PTZ∅138L210housingWiper
P23PTZ∅138L210housingThermalimager
F31Fixed∅138L290housingWiper
F33Fixed∅138L290housingThermalimager
5
EN

AXISExSeries
Specificconditionsofuse
WARNING
Alwaysreertotheproductcerticatesoranyspecicconditionsouse.
•Flameproojointsarenottobemodied.
•Cabletemperaturecanexceed60°C.Useasuitablecableortheendapplication.
•Cableentriesintotheequipmentshallutilisesuitablycertiedcableglands,thread
adaptorsorplugsthatshallprovideaminimumdegreeoprotectiontomaintainthe
ingressratingotheequipment.AsaminimumthisshouldbeIP66orIP67.
•Unusedcableentryaperturesshallbeclosedwithsuitablycertiedblankingplugs.
•Theprotectiveguardonthethermalhousingsmustnotberemoved.
•YieldstrengthotheendcapastenersisA4-80.
•Forcoalminingapplications,equipmentshallonlybeinstalledwhereithasbeen
assessedthatthereisalowriskomechanicaldamageromimpactswhichcould
compromisetheenclosure’sameprooprotection.
6

AXISExSeries
Installation
WARNING
Allinstallationandmaintenancemustbecarriedoutbyasuitablyskilledelectrician
inaccordancewithalllocalandnationalstandardsandcodesopracticee.g.NFPA70
(NationalElectricalCode),CSAC22.1(CanadianElectricalCode,PartISaetyStandardor
ElectricalInstallations),IEC/EN60079-14(Explosiveatmospheres-Electricalinstallations
design,selectionanderection)andIEC/EN60079-17(Explosiveatmospheres.Electrical
installationsinspectionandmaintenance).
Theinstallermustcomplywiththetechnicaldataattached.
Ensurethatallitemsareapprovedandcertiedortheenvironmentalandinstallation
requirements.Theratinglabelmustbecheckedtoensuretheunitisbeingusedwithinthe
correctambienttemperatureandenvironmentalconditions,andthatthepowersupplyis
suitable.
Usestainlesstoolstoavoidruststainsorpittingcorrosion.Stainlesssteelis
corrosion-resistant,butextraneousrustcanappearithematerialishandledincorrectly.
Equipmentmustbeinstalled≤2000mabovesealevel.
Modicationsordesignchangestothedevicesarenotallowed.
Saetyrulesandnationalregulationsmustbeobserved.
Neverinstalldevicesinareasthatmayexceedtheambienttemperaturerange.
Aggressivesubstancesmayrequireextraprotection.
Thedevicemustbeprotectedbyadditionalmeansoprotectioniitisexposedtoexcessive
externalstress,thatisvibration,heatorimpact.
Ithedeviceisnotutilizedinamannerspeciedbythemanuacturer,thedevice’s
protectionmaybeimpaired.Incomingcablesmustcomplywiththenationalstandards.
Suitablycertiedcableglandsandblankingplugsmustbeused.Threadormmustbe
M25x1.5orM20x1.5,dependingonproducttype,withtolerance6g/6HaccordingtoISO
965.ThecableglandusedmustnotinvalidatetheIPratingotheenclosureandmustbe
ratedortheinstallation.
Allentriesmustbepluggedwithsuitablecertiedequipment.
Fixingbracketsmustbetighteneduponinstallation.Suitablescrewsmustbeused.Seethe
product’sdatasheetorinormationabouttheproductweight.
ReplacementpartsmayonlybeinstalledusingcomponentpartsasspeciedbyAxisExAB.
7
EN

AXISExSeries
Wiring
WARNING
Thedevicemustbeelectricallyinstalledandservicedbyskilledpersons.
ACmainselectricalsupplyshouldincludecircuitbreakerratedmaximum20A.
Thedevicerequiresasurgeprotectordevice,aspartotheinstallation,toprevent
transientovervoltageexceeding2500Vpk.ACmainselectricalsupplyshouldhavea
readilyaccessibleall-polemainsdisconnectdeviceprovidedaspartonthebuilding
installation.Thedevicemustbeconnectedtoprotectiveearththroughtheinternalearth
terminalconnection.
Externalearthingpointsareorsupplementalbondingonlywherelocalauthoritiespermit
orrequiresuchaconnection.
Earthconnectionerruleshouldbeoasuitablematerialastoavoidcorrosion.
Disconnectthedeviceromthepowersourcebeorestartinganyoperations.
Ensurethatthevoltageiscorrectbeorebeginninganymaintenanceorconnections.
Usesuitablycolorcodedconductorsorothermeansoidentication.
Earthingconductorsshouldbegreenandyellow.
Takeextracaretonotdamagethethreadorm.
8

AXISExSeries
WiringofP21andP23
1Earthsupplementalbonding
2TB1auxiliaryOUT
3NetworkconnectorR45
4SFPcage
5TB2supplyIN
6Earthstud
7TB2supplylive
8TB2supplyneutral
9TB2N/C
10TB1auxiliaryOUT+48VDC14.4Wmax
11TB1auxiliaryOUT0VDC
ConnectthePTZcamerawiringtotheconnectionchamberatthebaseothedevice.
9
EN

AXISExSeries
1.Removethetwolockinggrubscrews.Usetheincludedstainlesssteelbits.
2.Removethethreadedchambercover.Toavoiddamagingthethreads,usetheincluded
removaltool.
3.Routethecablesthroughthreadedentrypointsandsuitablycertiedglands.
WARNING
Earthingconnectionmustbeminimum14AWG(2mm²)conductorwithgreenandyellow
insulation.ConnectthroughtheM4earthstudusingthesuppliedcrimpringterminal.
Tightenwitha7mmringspannerorsocket.
Theterminalplugscanbedisconnectedtoalloweasyterminationoutsideotheenclosure.For
TB1andTB2usewirebetween18-12AWG(0.8-3.0mm²).
WARNING
Onlyonewireshouldbeconnectedtoeachclampingpoint.
Anexternalearthconnectionpointisavailableorupto11AWG(4mm²)connection.When
used,itshallbeusedwithacrimpringterminal.
UseanRJ45connector(CAT5orhigher)ornetworkconnection.Optionally,anSFPslotisavailable
oranadditionalnetworkconnection,thisportutilizesvariousSFPmodulesincludingbreoptic.
WARNING
Theuseoaberopticcableandinternalconnectionsshallcomplywithrequirements
oUL/IEC/EN60079-14.
Whenwiringiscompleted,astenthethreadedchambercoverandtightenuntilthejointisclosed.
Tightenthetwolockinggrubscrews.Usetheincludedstainlesssteelbits.
10

AXISExSeries
WiringofF31andF33
1Earthsupplementalbonding
2Earthstud
3TB2supplyIN
4TB1auxiliaryOUT
5SFPcage
6NetworkconnectorR45
7TB2supplylive
8TB2supplyneutral
9TB2N/C
10TB1auxiliaryOUT+48VDC14.4Wmax
11TB1auxiliaryOUT0VDC
Connectthexedcamerawiringtotheconnectionterminalatthebackothedevice.
1.Removingthe6M5x12A4socketheadscrews.Usetheincludedstainlesssteelbits.
11
EN

AXISExSeries
2.Removethebackcover.Careullypullthebackcovero.
3.Routethecablesthroughthreadedentrypointsandsuitablycertiedglands.
CAUTION
Takeextracaretonotdamagethejointsurace.
WARNING
Earthingconnectionmustbeminimum14AWG(2mm²)conductorwithgreenandyellow
insulation.ConnectthroughtheM4earthstudusingthesuppliedcrimpringterminal.
Tightenwitha7mmringspannerorsocket.
Theterminalplugscanbedisconnectedtoalloweasyterminationoutsideotheenclosure.ForTB1
andTB2usewirebetween18-12AWG/0.8-3.0mm².
WARNING
Onlyonewireshouldbeconnectedtoeachclampingpoint.
Anexternalearthconnectionpointisavailableorupto11AWG(4mm²)connection.Whenused,
itshouldbeusedwithacrimpringterminal.
UseanRJ45connector(CAT5orhigher)ornetworkconnection.Optionally,anSFPslotisavailable
oranadditionalnetworkconnection,thisportutilizesvariousSFPmodulesincludingbreoptic.
YoucanalsousetheRJ45networkconnectiontosupplypowertothehousing.Whenusedwith
PoweroverEthernet(PoE),thePowerSourcingEquipment(PSE)shallcomplywithIEEE802.3bt
type3Class6PoE.
WARNING
Theuseoabreopticcableandinternalconnectionsshallcomplywithrequirements
oUL/IEC/EN60079-14.
Whenwiringiscompleted,tthebackcover.Tightenthe6M5x12A4socketheadscrewsto8Nm
±0.5torque.Usetheincludedstainlesssteelbits.
12

AXISExSeries
Maintenance
Thedevicedoesnotcontainanyservicableparts.Nocoversorsealsshouldberemoved.
WARNING
Itisstrictlyprohibitedtocarryoutanyattemptorepairsotherthanbyapprovedand
trainedpersonnel.
Checkallmountingastenersortightnessataregularinterval.
Tomaintainasmoothoperation,cleanthedeviceregularly.Usewater,milddetergent
andasotcloth.
13
EN

AXISExSeries
Specifications
Markings
Youcanndthemarkingsonthedevices’mainbody.
Note
Inormationbelowisonlyanexample.Forspecicinormation,seetheproduct’sdatasheet.
Manuacturer’snameandaddressAxisExAB
Gränden1
SE-22369LUND
SWEDEN
TypeP21,P23,F31orF33
SerialnumberAK********
YearandmonthomanuactureYYY/MM
ModelSeeproductspecicdocument
PartnumberSeeproductspecicdocument
Notiedbodynumber2804
HazardousarearatingsIM2ExdbIMb
II2GExdbIICT6-T4Gb
II2DExtbIIICT85°C-T135°CDb
ClassIDiv1GroupsB,C,DT6-T4
ClassIIDiv1GroupsE,F,GT6-T4
ClassIZone1AExdbIICT6-T4Gb
Zone21AExtbIIICT85°C-T135°CDb
ClassIIIDiv1
CerticatenumbersATE:ExVeritas20ATEX0651X
IECEx:EXV20.0017X
MET:E115198
Ambienttemperature-60°Cto+60°C
IngressprotectionIP66/IP67/68,Type4X
14

AXISExSeries
VoltagePTZ:
100-240VAC±10%
Fixed:
100-240VAC±10%
POE802.3btType3
PowerPTZ:150W
Fixed:56W
Frequency50-60Hz
EntrythreadsizeM25orM20dependingonmodel
15
EN

AXISExSeries
imensionstypeP21andP23
16

AXISExSeries
imensionstypeF31andF33
17
EN

AXISExSeries
Furtherinformation
•Theusermanualisavailableataxis.com
•Tocheckithereisupdatedrmwareavailableoryourdevice,seeaxis.com/support
•Foruseulonlinetrainingsandwebinars,seeaxis.com/academy
Optionalaccessories
Foracompletelistoavailableaccessoriesorthisproduct,gototheproduct’spageon
axis.comandselectSotware&Accessories.
Contactinformation
AxisExAB
Gränden1
22369Lund
Sweden
Tel:+46462721800
Fax:+4646136130
axis.com
18

AXISExSeries
Safetyinformation
Hazardlevels
DANGER
Indicatesahazardoussituationwhich,inotavoided,willresultindeathorseriousinjury.
WARNING
Indicatesahazardoussituationwhich,inotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesahazardoussituationwhich,inotavoided,couldresultinminorormoderate
injury.
NO NO
NOTICE TICE
TICE
Indicatesasituationwhich,inotavoided,couldresultindamagetoproperty.
Othermessagelevels
Important
Indicatessignicantinormationwhichisessentialortheproducttounctioncorrectly.
Note
Indicatesuseulinormationwhichhelpsingettingthemostoutotheproduct.
19
EN

AXISExSeries
Historiquedelaversion
VersionDateDétails
1.02021-09-17Premièreversion
2.02022-01-10Inormationsminières
ajoutées
20
Table of contents
Languages:
Other Axis Digital Camera manuals

Axis
Axis M10 Series User manual

Axis
Axis Q1615-LE Mk III User manual

Axis
Axis Q1656-DLE User manual

Axis
Axis Companion Cube LW User manual

Axis
Axis P5676-LE User manual

Axis
Axis Axis Camera Families for Autodesk Revit User manual

Axis
Axis Q1656 User manual

Axis
Axis M5075-G User manual

Axis
Axis Q1656-LE User manual

Axis
Axis W100 User manual