10
Installation and maintenance
Mounting the bracket
On the bottom of the movinghead, there are two holes to mount the included bracket, using the
included bolts. It is possible to mount a G-clamp or halfcoupler to this bracket. It is also possible to
mount the bracket on a ceiling, wall, bar, floor, desk or any flat surface. Use proper equipment to
install this fixture, as a dropping fixture may cause severe injury! Ayra is not responsible for any
damage or injuries caused by improper installation.
Cleaning
Make sure to clean the exterior of the unit frequently, as the build-up of dust and dirt may have
negative effects on the cooling and optics of the fixture.
The exterior (plastic parts) of the unit can be cleaned with a damp cloth. The optics of the fixture can
be cleaned with a clean cloth or paper towel, with the addition of a non-aggressive glass cleaning
solution.
Clean the fan outlet and the cooling vents with a small brush, while using vacuum cleaner suction to
remove any loose dust and/or dirt.
Clean the exterior of this fixture once a month. When using this fixture intensively, the frequency of
maintenance needs to be increased.
Transport
When using this fixture in mobile setups, provide sufficient protection during transport. Use the original
packaging of this unit, or use a professional flightcase with proper foam inlay. This way the electronics,
optics and housing are protected against severe shocks, exterior damage and failing electronics.
Make sure the moving parts of the movinghead (pan and tilt motors) are secured during transport.
Shocks and fierce movement of the pan and tilt stepping motors may cause permanent damage.
After use, let the unit cool down for at least 10 minutes. When using DMX, use the ‘black out’ option on
your DMX controller. This way the unit is positioned in a static stand-by mode and the internal fan is
able to cool down the internal electronics, which decreases the chance of damage during transport.
Replacing the internal fuse
First check whether a failing power supply may be the cause of malfunction. When you suspect that
the internal fuse is broken, the fuse can be replaced by removing the fuse cover, located directly below
the power inlet.
WARNING: Before changing the fuse, always disconnect the fixture from your wall outlet or any other
power supply to prevent electric shocks.
Always replace a broken fuse with a fuse that has the same type and rating. After the fuse has been
replaced, always close the fuse-cover. Reconnect the fixture to your power supply and check whether
the problem is solved. When this does not solve your problem, contact your local dealer for help.
IMPORTANT: A spare fuse is located inside a special compartiment of the fuse holder.
Spare parts
This unit has no user serviceable parts inside. When any damage to internal components occurs,
contact your local dealer or a specialized technician in order to repair the fixture.
Focus
Below the beam output lens, there is a manually adjustable focus system. This way you can optimize