B.E.G. LUXOMAT PD9-M-DALI/DSI-FC User guide

360°
5,40 m
5,40 m
RJ
9,00 m
1
2
3
quer zum Melder gehen
frontal zum Melder gehen
Unterkriechschutz
3 2
1
22 - 30 mm
min. 34 mm
165 mm
24 mm
24 mm
45
25
12 16
45
24
25
16
Installation and Operating Instruction for B.E.G. - Occupancy detectors PD9-M-DALI/DSI-FC und PD9-M-DALI/DSI-GH-FC
Unlocking device
Lock device
LUXOMAT®PD9-M-DALI/DSI(-GH)
1b. Mounting preparations
Work on the 230V mains supply
may only be carried out by quali-
fied professionals or by instructed
persons under the direction and
supervision of qualified skilled
electrical personnel in accordance
with electrotechnical regulations.
Disconnect supply before installing!
When in Master/Slave mode of
operation, the Master-appliance
must always be installed at the
location where there is least
daylight.
Switching between DSI and DALI program
Factory setting DSI, press 1x DALI, press 2x DSI
(Toggle-function)
Luminance set point for constant light regulation
+ / – small steps +/ –big steps
Dimming
The following approach will prove useful when setting a
command value (example workplace): Place a luxmeter flat
on the desk, then, using the remote control IR-PD-DALI, adjust
the light up or down by pressing the keys max or min until
the desired command value which best suits your require-
ments has been reached.
Automatic reading in the current light value
as new luminance set point
Individual light value 2 - 2500Lux
Follow-up time (relay and channel 1)
1 upto 30min.
Orientation lighting and its follow-up time
OFF button: No orientation light
Grey button: Programming the switch-off delay time
On button:
Orientation light is permanently activated.
Note: During the orientation light phase, the constant light reg-
ulation is also active: if there is sufficient brightness, dimming
occurs < 2V and, if applicable, the lighting is switched off.
Preset/user mode => (see page 2, point 8)
Fully automatic/semi automatic mode => (see page 2, point 7)
Semi automatic: green LED,
Fully automatic: red LED on for ca. 3 sec.
Resetting when open
All values which have been programmed using the remote
control IR-PD-DALI are deleted, and those values which have
been set by potentiometer are activated.
Lock device
Test mode
Reset to deactivate
Resetting when closed
The lighting relay is switched off, i.e.
opened and the follow-up times reset.
Permanent protection against sabotage
This function blocks the unit permanently (green LED is
illuminated). Th
is operating mode can only be activated
during the period of 5 seconds after pressing the “lock“
button. This status will only permit actuating the function
“Light on/Light off”.
The procedure for leaving this mode is as follows:
1. Switch off the current
2. Apply current for 31 - 59 seconds
3. Switch of the current again
4. Apply current
5. Open detector
Light on/off => (see page 2, point 9)
The light will remain switched on/off for as long as move-
ments are detected in the areas of coverage. Once the last
movement has been detected, the light will remain on for
the duration of the follow-up time as per setting.
The appliance will then return independently to the mode
selected (Fully or Semi-automatic).
1a. Features
*
For connection of up to 12 lamps
* Suitable for dimmable electronic
ballasts and control modules
* DALI/DSI output
* Constant light control
* Manual switching/dimming
* Semi or completely automatic
operation
*
Luminance (brightness) set point,
switch-off delay time for LIGHT and
orientation-light adjustable
* Sensor and power sections in one
housing
* Infrared remote control
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
20 %
max
50
Lux
1500
Lux
ON
OFF
+–
DSI/
DA LI
2a. Installation LUXOMAT®PD9-M-
DALI/DSI(-GH)-FC
The detector has
been designed and
developed specifi-
cally for installation in
suspended ceilings.
A circular opening of
diameter min. 34mm
must be produced in
the ceiling.
Having connected the cables in accordance with
the regulations, connect the power supply via the
RJ11 plug. Therefore, open the power supply with
the help of the screws and close it afterwards. After
that, put the power supply through the opening in
the ceiling and mount the sensor onto the ceiling
according to figure.
3.
Settings carried out
using remote control
(optional)
Remote control LUXOMAT®
IR-PD-DALI
Check Battery:
Open battery compartment
by pressing the plastic
springs together and remo-
ving the battery-holder.
The LUXOMAT®PD9-M-
DALI/DSI(-GH) enters an
initial 60-second self-test
cycle, when the supply
is first connected. The
occupancy detector is
ready for operation.
2b. Self test cycle
Option:
Wall bracket for remote control
IR-PD-DALI
Walking across
Walking towards
Seated
6. Range of Coverage
PD9-M-DALI/DSI
5. Dimensions
PD9-M-DALI/DSI PD9-M-DALI/DSI-GH
PD9-M-DALI/DSI-GH
4. Exclude sources of
interference
PD9-FC PD9-GH-FC
In case the sensing area of the
LUXOMAT®
PD9-M-DALI/DSI(-GH)
is
too large or areas are being covered
that should not be monitored, the range
can be reduced or limited through use
of the enclosed masking clips.
Overview range in dependence from the mounting
height
Mounting
height
Range (circular detection) T=18°C
walking across
5.00 m Ø=3.00 m
6.00 m Ø=3.50 m
7.00 m Ø=4.20 m
8.00 m Ø=4.80 m
9.00 m Ø=5.40 m
10.00 m Ø=6.00 m
GB
10 m
6 m
2.50 m
10 m
360°
2.50 m
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
S
R
NNL
S
T
L'NL
DALI
DSI
D D
13.
Technical data
PD9-M-DALI/DSI(-GH)
11. Wiring diagram
12. PD9-M-DALI/DSI(-GH) - Connections
MAN 5976 – 071209–5
14. LED-functional indicators, fault-finding
The functional indicators in the case of the
LUXOMAT®
PD9-MASTER-DALI/DSI (red and green LED‘s)
Red LED indicating self-checking mode (over a period
of 60 seconds following mains‘-supply lock-on)
Flashing at intervals of 1 second
EEPROM/memory empty
Flashing rapidly
EEPROM/memory contains information
Red LED as an indicator of status
Flashing irregularly
Movements are detected within the area of coverage
Flashing regularly
Detector identifies bright, light off
(dependent upon operating mode)
Not illuminated
Detector identifies dark, light on
(dependent upon operating mode)
Flashing extremely rapidly
Too bright / Too dark / Undefined
Red LED as an acknowledgement of receipt for
commands from the remote control
Illuminated for 2 seconds
Signal validly received
Illuminated for 0.5 seconds
Not-accepted command, detector blocked
Flashing extremely rapidly
Not-accepted command, occurs, for example, when
an attempt is made to input twilight-value are too
bright or too dark
Green LED as an acknowledgement of receipt for
commands from the remote control
Lights up for 3 seconds
Semi automatic or user signal correctly received
Green LED as an indicator of status (only for status
“Permanent protection against sabotage”)
Flashing irregularly
Movement are detected within the area of coverage
Flashing regularly
Detector identifies bright, light off
(dependent upon operating mode)
Not illuminated
Detector identifies dark, light on
(dependent upon operating mode)
lluminated for 2 seconds
Signal validly received
(dependent upon operating mode)
8. Manual Dimming - Preset /User
(for IR-PD-DALI functions see page 1)
You can dim manually by pressing the pushbutton for
a long time (> 2 sec). When the button is released,
the current dimming value is retained. Upon renewed
dimming, the dimming direction is reversed.
PRESET –the luminance set point is set during start-up
operation by the installer and remains unchanged.
The luminance set- point congured through manual
dimming is only applied for the time being.
Caution:
The constant light regulation is now deactivated!
The currently set articial light is retained independent
of the ambient/daylight brightness!
After switching off and then back on, the originally set
luminance set-point is reset = constant light regulation
is activated.
USER - can only be activated via the remote control!
The luminance set-point is changed upon each manual
dimming and re-adjusted by the user (Conformation
through relay clicking!)
The constant light regulation remains activated!
7. Fully / Semi automatic mode
(for IR-PD-DALI functions see page 1)
Fully automatic operation
In this operating mode, the lighting switches automati-
cally on and off for increased comfort, depending on
presence and brightness.
Semiautomatic operation
(Semiautomatic can only be activated via the remote
control!)
In this operating condition, in order to gain increased
savings, the lighting is energized only after being manu-
ally switched on.
Switch-off takes place automatically.
The semiautomatic mode basically behaves like the fully
automatic one. However, the difference is that switching-
on must always be carried out manually!
As many (closer-contact) buttons as desired can be wired
in parallel on the “S” button input (ON/OFF Dimm).
9. Manual Switching
You can switch the lighting on and off manually by
pressing the pushbutton for a short time. It will stay on or
off as long as people are detected plus the congured
follow up time.
L
N
Terminal connection for MASTER-/SLAVE-operation
N – N L – L R – R
MASTER SLAVE
230V
~
DA DA
DALI-EB 1
230V
~
DA DA
DALI-EB 2-12
R S N L DALI
T5 und T8
uorescent
lamps
Type FC
PD9-M-DALI/DSI – Master 92920
PD9-M-DALI/DSI-GH – Master 92938
PD9-S – Slave 92905
PD9-S-GH – Slave
92928
LUXOMAT®Remote control:
IR-PD-DALI (incl. wall bracket) 92094
Accessory:
Wall bracket for remote control as replacement
92100
10. Article / Part-Nr. / Accessory
Circuit diagram
L
N
S1S2
up to 12 EBs
EB 1
EB 2
EB 12
For T5 and
T8 uorescent
lamps
SLAVE
20%
LUXOMAT®IR-PD-DALI
RESET TEST
30
min
15
min
10
min
5
min
1
min
OFF
60
min
30
min
10
min
1
min
ON
-
-
-
max
++
+
min
DSI/
DALI
PD9-M-DALI/DSI
PD9-M-DALI/DSI-FC
= up to 12 electronic ballasts (EB) are
connectable.
Power supply: 230 V~ +6 %/-10 %
Power consumption: < 1W
Ambient temperature: -25°C to +50°C
Degree of protection/class:
IP20 / II
Settings:
by remote control
Light values - IR-PD-DALI:
50 - 1500Lux
Extension of the detection area:
with Slaves
Area of coverage:
circular 360°
Range of coverage Ø H 2.50m / T = 18°C:
PD9-M-DALI/DSI
seated
2.50 m
/
tangential
10 m /
radial
6 m
PD9-M-DALI/DSI-GH max. Ø
5.40 m
Recommended height for mounting:
PD9-M-DALI/DSI
2 - 3 m
PD9-M-DALI/DSI-GH 5 - 10 m
Light measurement:
mixed light, daylight and artificial light
• DALI-Output
digital BUS control wire, 2-core, no polarity
(broadcast only)
Max. no. of series-connected electronic ballasts:
up to 12
Time-settings:
1 - 30min. / Test
Dimensions H x Ø [mm]:
PD9-M-DALI/DSI
Ø 45 x H 28 mm
PD9-M-DALI/DSI-GH
Ø 45 x H 40 mm
Power supply L 165 x W 24 x H 24 mm
Declaration of Conformity:
The product complies with
the low voltage recommendation 2006/95/EC and the
EMV recommendation 2004/108/EC.

This manual suits for next models

3

Other B.E.G. Security Sensor manuals

B.E.G. LUXOMAT PD4-M-1C Series User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-1C Series User guide

B.E.G. LUXOMAT PD4N-KNX-K-DX How to use

B.E.G.

B.E.G. LUXOMAT PD4N-KNX-K-DX How to use

B.E.G. LUXOMAT 180-SC Service manual

B.E.G.

B.E.G. LUXOMAT 180-SC Service manual

B.E.G. LUXOMAT PD4-S Series User guide

B.E.G.

B.E.G. LUXOMAT PD4-S Series User guide

B.E.G. RC-plus next 130 Service manual

B.E.G.

B.E.G. RC-plus next 130 Service manual

B.E.G. WAVE-PIR-120-DR-(O/V) User manual

B.E.G.

B.E.G. WAVE-PIR-120-DR-(O/V) User manual

B.E.G. LUXOMAT PD4-M-DIM-SM User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DIM-SM User guide

B.E.G. LUXOMAT PD4-M-3C-TRIO Series User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-3C-TRIO Series User guide

B.E.G. LUXOMAT PD4-M-1C-C-PS User manual

B.E.G.

B.E.G. LUXOMAT PD4-M-1C-C-PS User manual

B.E.G. 93385 User manual

B.E.G.

B.E.G. 93385 User manual

B.E.G. LUXOMAT net PD11-KNX-FLAT-ST User manual

B.E.G.

B.E.G. LUXOMAT net PD11-KNX-FLAT-ST User manual

B.E.G. LUXOMAT PD4-M-2C-DUO User manual

B.E.G.

B.E.G. LUXOMAT PD4-M-2C-DUO User manual

B.E.G. LUXOMAT PD4-M-1C-GH-AP User manual

B.E.G.

B.E.G. LUXOMAT PD4-M-1C-GH-AP User manual

B.E.G. LUXOMAT PD4-S-DAA4G User guide

B.E.G.

B.E.G. LUXOMAT PD4-S-DAA4G User guide

B.E.G. LUXOMAT PD2-M-2C-24V User guide

B.E.G.

B.E.G. LUXOMAT PD2-M-2C-24V User guide

B.E.G. LUXOMAT PD4-M-1C-SM User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-1C-SM User guide

B.E.G. LUXOMAT PD4-M-DIM-Corridor User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DIM-Corridor User guide

B.E.G. LUXOMAT PD4-M-DALI/DSI-C User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DALI/DSI-C User guide

B.E.G. LUXOMAT PD4-M-2C-DS User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-2C-DS User guide

B.E.G. PD4-M-1C-GH-SM User guide

B.E.G.

B.E.G. PD4-M-1C-GH-SM User guide

B.E.G. LUXOMAT PD2N-LTMS-RR User manual

B.E.G.

B.E.G. LUXOMAT PD2N-LTMS-RR User manual

B.E.G. LUXOMAT PD4-S Series User guide

B.E.G.

B.E.G. LUXOMAT PD4-S Series User guide

B.E.G. LUXOMAT Indoor 180/R-2W UK Service manual

B.E.G.

B.E.G. LUXOMAT Indoor 180/R-2W UK Service manual

B.E.G. LUXOMAT PD4-S-K User manual

B.E.G.

B.E.G. LUXOMAT PD4-S-K User manual

Popular Security Sensor manuals by other brands

Trust SECURITY PLUS-LINE ALMDT-2000 user manual

Trust

Trust SECURITY PLUS-LINE ALMDT-2000 user manual

Pyreos ezPyro SMD user manual

Pyreos

Pyreos ezPyro SMD user manual

Agilent Technologies 1200 Infinity Series user manual

Agilent Technologies

Agilent Technologies 1200 Infinity Series user manual

Siemens FDOOTC441 installation instructions

Siemens

Siemens FDOOTC441 installation instructions

Cofem CLVR02EXT manual

Cofem

Cofem CLVR02EXT manual

Electro Detectors Zerio Plus EDA-D6000 installation instructions

Electro Detectors

Electro Detectors Zerio Plus EDA-D6000 installation instructions

Etherma eNEXHO-IN Assembly and operating instructions

Etherma

Etherma eNEXHO-IN Assembly and operating instructions

Extech Instruments EzFlex EZ40 user guide

Extech Instruments

Extech Instruments EzFlex EZ40 user guide

Perel EMS103 user manual

Perel

Perel EMS103 user manual

SGB VLX Ex Series Documentation

SGB

SGB VLX Ex Series Documentation

Conrad Electronic FS20 PIRI-2 operating instructions

Conrad Electronic

Conrad Electronic FS20 PIRI-2 operating instructions

ActiV POLIBOX 120888 quick start guide

ActiV

ActiV POLIBOX 120888 quick start guide

Vishay TSSP57P38 manual

Vishay

Vishay TSSP57P38 manual

Crow EDS-2000 Installation instructions & user manual

Crow

Crow EDS-2000 Installation instructions & user manual

teko Astra-43A user guide

teko

teko Astra-43A user guide

Banner VS8LEJ instruction manual

Banner

Banner VS8LEJ instruction manual

Halma Apollo Marine 65 Series quick start guide

Halma

Halma Apollo Marine 65 Series quick start guide

Pyronix HomeControl+ Installation & reference manual

Pyronix

Pyronix HomeControl+ Installation & reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.