USA-EN
1. Product information
• MINI secondary sensor, requires connection to
primary MINI-P-PP-A-FC sensor and PP-A-J or PP-1-J
power pack or proprietary low voltage system
• Designed for indoor locations
• Up to 4 secondary sensors may be connected with
a primary sensor to increase detection coverage.
• Spring clips for quick and easy installation in
suspended ceilings and light fixtures
• 5-year limited warranty
• Masking blinds included
• ROHS compliant
2.
Operation with power pack
PP-A-J and PP-1-J
The MINI-P with B.E.G. PP-A power pack detects both
motion and the ambient light level in the room and
then automates the lights according to the parameters
set by the installer or the building management. The
MINI-S extends the motion detection coverage of
the system. The integrated light sensor in the MINI-P
constantly measures the ambient light and if the light
level is sufficient, the light will be switched off. If the
ambient light level is below the preset brightness level
the lights will be allowed to come on when the sensors
detect movement in the room.
When motion is detected in the room the PP-A’s
auxiliary dry contact relay will send a signal to
HVAC or other systems indicating that the room
is occupied. With the integration of simple off the
shelf, normally-open momentary switches, the MINI-
PP-A can be set to operate in vacancy mode via the
auto/manual switch selector on the power pack.
3. Safety information
!
Work should be carried out by qualified pro-
fessionals or by instructed persons under the
direction and supervision of qualified skilled
electrical personnel in accordance with electri-
cal regulations.
!
The device is not to be used to isolate other
equipment from the mains supply!
4. Mounting
Select sensor(s) mounting location based on room di-
mensions and sensor coverage pattern. Avoid placing
sensor(s) less than four feet away from a heat and/
or ventilation sources. Avoid placing sensor(s) where
view will be directed
outside of intended
controlled space, this
to prevent outside
sources from activating
sensor(s).
A circular opening
1.3 in/34 mm in diam-
eter must be made in
the ceiling.
Having connected
the cables in accordance with the national and local
electrical codes, connect the sensor to the power pack
using the RJ12 connector. Pass sensor’s RJ12 connec-
tor through ceiling opening. Next, squeeze spring
clips through ceiling opening. Sensor should clip
securely into place.
(See Figure)
!
When using primary and secondary devices,
please mount the primary device at the place
with the least amount of natural light.
5. Position LED
LED 1 red
6. Self test cycle/Startup behavior
When power is first applied, the sensor enters an
initial 60 second self-test cycle. During this time the
device does not respond to movement and stays on.
7. Range
33 ft/10 m
20 ft/6 m
13 ft/4 m
33 ft/10 m
360°
8 ft/2.50 m
RJ 12
2
1
3
1
quer zum Melder gehen
frontal zum Melder gehen
Unterkriechschutz
Walking across
2
quer zum Melder gehen
frontal zum Melder gehen
Unterkriechschutz
Walking towards
quer zum Melder gehen
frontal zum Melder gehen
Unterkriechschutz
Seated
3
8. Exclude sources of interference
To prevent false activation from external heat-emitting
sources, use blinds to mask sensor viewing angle.
9. Decription / Part No. / Accessory
Description Part No.
MINI-S-PP-FC 97183
MINI-P-PP-A-FC 97180
Remote control:
via B.E.G. Controls IR-Adapter
92726
Power pack PP-A-J 97020
Power pack PP-1-J 97036
The required app for smartphones can be down-
loaded from the App Store for iOS smartphones and
Google Play Store for Android
smartphones.
!
R
emote only works with primary MINI-P-PP-A-FC
sensor!
10. Technical data
Power supply: 24VDC
Pulse output: Digital output
Pulse duration: 1sec. ON, 9 sec. OFF
Ambient temperature: -13°F-122°F/-25°C to +50°C
Protection/Polution degree:
IP20 / II
Recommended height
for mounting:
8 - 10 ft / 2.44 - 3.05 m
Range of coverage Ø H 8.2 ft/2.50 m :
seated 13 ft /4
m
walking across 33 ft /10 m
walking towards 19.7 ft /6 m
Area of coverage:
360°
Dimensions:
H 1.1in x Ø 1.42 in
H 28 x Ø 36 mm
Type 1 Actions
11. Manual switching
!
See manual of the power pack PP-A/PP-1: “PB
load” and “All off” (only PP-A)!
12. LED-functional indicators
LED activity after sensor is energized (60 second
self-test cycle period).
Operating state LED function indicators
Self-test cycle Red blinks once per second and
for 60 seconds
LED function indicators during operation
Process LED function indicators
Motion detection Red LED flashes on each
detected movement
13. MINI-S-PP-FC - Connection
Connect the B.E.G. Controls MINI-S-PP-FC and the
MINI-P-PP-A-FC sensor to the PP-A-J or PP-1-J power
pack using the sensor’s RJ12 connector and splitter.
NOTE:
Splitter: (RJ12 male to dual RJ12 female included
with every secondary mini sensor)
Installation and Operating Instruction for B.E.G. Controls - Secondary sensor MINI-S-PP-FC
MINI-S-PP-FC
Controls
B.E.G.
≤34 mm
≤1.3 in
1
RJ12 Splitter
14. Wiring diagrams with Power
pack PP-A-J and PP-1-J
Standard mode with Primary/Secondary
!
Secondary sensors and primary sensor must be
connected to the same power pack.
!
Secondary sensors and primary sensor must be
connected to the same power pack.
B.E.G. Controls
277 Highway 74 N, Suite 319
Peachtree City, GA 30269
Phone: 770-349-6341
Email: info@begcontrols.com
MAN 8887-180316_1
Controls
B.E.G.
Hot
White
Black
Neutral
Brown
Orange
Gray
Red
Y / B
Y
Y / R
HVAC
Load
PB PB PB
Power Pack
Switch
PP-A-J
LED Switch
RJ 12
RJ 12
RJ 12
6
S
Secondary
P
Primary
All Off HVAC Load
Red
Red
120 - 277 VAC
24 VDC
max. 200 mA
RJ12 male
to dual
RJ12
female
splitter
Hot
White
Black
Neutral
Gray
Red
Load
PB
Power Pack
Switch
PP-1-J
LED Switch
RJ 12
RJ 12
RJ 12
6
S
Secondary
P
Primary
Load
Red
Red
120 - 277 VAC
24 VDC
max. 200 mA
RJ12 male
to dual
RJ12
female
splitter

Other B.E.G. Security Sensor manuals

B.E.G. LUXOMAT PD4-S-GH User guide

B.E.G.

B.E.G. LUXOMAT PD4-S-GH User guide

B.E.G. LUXOMAT net PD11-KNX-FLAT-BA User manual

B.E.G.

B.E.G. LUXOMAT net PD11-KNX-FLAT-BA User manual

B.E.G. LUXOMAT PD9-DIGI-FC User guide

B.E.G.

B.E.G. LUXOMAT PD9-DIGI-FC User guide

B.E.G. LUXOMAT PD4-M-1C-GH-AP User manual

B.E.G.

B.E.G. LUXOMAT PD4-M-1C-GH-AP User manual

B.E.G. LUXOMAT PD9-S User manual

B.E.G.

B.E.G. LUXOMAT PD9-S User manual

B.E.G. LUXOMAT net PD11-KNX-FLAT-ST User manual

B.E.G.

B.E.G. LUXOMAT net PD11-KNX-FLAT-ST User manual

B.E.G. LUXOMAT net PD4-M-DAA4G User guide

B.E.G.

B.E.G. LUXOMAT net PD4-M-DAA4G User guide

B.E.G. LUXOMAT PD9-M-1C+HVAC User guide

B.E.G.

B.E.G. LUXOMAT PD9-M-1C+HVAC User guide

B.E.G. KNX RC-plus next 230 KNX Service manual

B.E.G.

B.E.G. KNX RC-plus next 230 KNX Service manual

B.E.G. WAVE-PIR-120-DR-(O/V) User manual

B.E.G.

B.E.G. WAVE-PIR-120-DR-(O/V) User manual

B.E.G. Luxomat PD2N-M-1C-LED User manual

B.E.G.

B.E.G. Luxomat PD2N-M-1C-LED User manual

B.E.G. RC-plus next 130 Service manual

B.E.G.

B.E.G. RC-plus next 130 Service manual

B.E.G. LUXOMAT BL2 User manual

B.E.G.

B.E.G. LUXOMAT BL2 User manual

B.E.G. LUXOMAT PD4-S Series User manual

B.E.G.

B.E.G. LUXOMAT PD4-S Series User manual

B.E.G. LUXOMAT PD11-BMS-FLAT User manual

B.E.G.

B.E.G. LUXOMAT PD11-BMS-FLAT User manual

B.E.G. LUXOMAT PD4-M-DAA4G User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DAA4G User guide

B.E.G. LUXMAT PD4-S User guide

B.E.G.

B.E.G. LUXMAT PD4-S User guide

B.E.G. LUXOMAT LC-Click 140 Owner's manual

B.E.G.

B.E.G. LUXOMAT LC-Click 140 Owner's manual

B.E.G. LUXOMAT net PD4N-LTMS-RR User guide

B.E.G.

B.E.G. LUXOMAT net PD4N-LTMS-RR User guide

B.E.G. 93385 User manual

B.E.G.

B.E.G. 93385 User manual

B.E.G. LUXOMAT PD4-M-DALI/DSI-SM User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DALI/DSI-SM User guide

B.E.G. LUXOMAT PD4-M-TRIO-2DALI DSI-1C Wiring diagram

B.E.G.

B.E.G. LUXOMAT PD4-M-TRIO-2DALI DSI-1C Wiring diagram

B.E.G. LUXOMAT PD2-M-2C User manual

B.E.G.

B.E.G. LUXOMAT PD2-M-2C User manual

B.E.G. LUXOMAT PD4-BMS User manual

B.E.G.

B.E.G. LUXOMAT PD4-BMS User manual

Popular Security Sensor manuals by other brands

Bosch RF940E Installation instructions and operators manual

Bosch

Bosch RF940E Installation instructions and operators manual

LEGRAND 6 460 03 instruction manual

LEGRAND

LEGRAND 6 460 03 instruction manual

SGB DLR-G Documentation

SGB

SGB DLR-G Documentation

Niko SERVODAN 41-771 user manual

Niko

Niko SERVODAN 41-771 user manual

Hobby Electronics SFERICS manual

Hobby Electronics

Hobby Electronics SFERICS manual

hyfire ALTAIR HFI-PA-05 manual

hyfire

hyfire ALTAIR HFI-PA-05 manual

Enerwave ZWN-BPC installation instructions

Enerwave

Enerwave ZWN-BPC installation instructions

Climax EIR-32 manual

Climax

Climax EIR-32 manual

Velleman PEREL EMS106 user manual

Velleman

Velleman PEREL EMS106 user manual

NAPCO C 200 AP datasheet

NAPCO

NAPCO C 200 AP datasheet

AccuLine 40-6715 instruction manual

AccuLine

AccuLine 40-6715 instruction manual

CAME R Series manual

CAME

CAME R Series manual

Aritech EV1012 Installation sheet

Aritech

Aritech EV1012 Installation sheet

BGE AUDIO SWlTCH BGE-7500 Installation and operating instructions

BGE

BGE AUDIO SWlTCH BGE-7500 Installation and operating instructions

BabySense 7 user guide

BabySense

BabySense 7 user guide

schmersal RSS 36-I2-D-R-ST manual

schmersal

schmersal RSS 36-I2-D-R-ST manual

Bosch D-tect 120 Professional instructions

Bosch

Bosch D-tect 120 Professional instructions

Bosch ISN-AP1-T installation guide

Bosch

Bosch ISN-AP1-T installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.