Your system has a 24-hour circ pump. The circ pump
and the ozone generator run continuously.
Warm/Cool (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set at 100F°/37°C. The last
measured temperature is constantly displayed on the LCD.
Note that the last measured spa temperature displayed is
current only when the circ pump has been running for at
least 2 minutes.
To display the set temperature, press the “Warm” or “Cool”
pad once.
To change the set temperature, press the pad a second time before
the LCD stops flashing. Each press of the “Warm” or “Cool” pad
will continue to either raise or lower the set temperature.
After three seconds, the LCD will stop flashing and display the
current spa temperature.
Jets 1
Touch the “Jets 1” button once to turn pump 1 on or off, and
to shift between low and high speeds (if equipped). If left
running, the low speed of the pump will automatically turn off
after 4 hours, and the high speed will automatically turn off after
15 minutes.
Jets 2 (If equipped)
Touch the “Jets 2” button once to turn pump 2 on or off. If left
running, pump 2 will automatically turn off after 15 minutes.
Blower (If equipped)
This button is used to turn the blower on and off. If left on, the
blower automatically turns off after 15 minutes.
Light
Press the “Light” button to turn the light on and off. If left on,
the light automatically turns off after 4 hours.
(over)
VS510S/GS510S Control Reference Card
Circ Operation
Initial Start-up
When your spa is first actuated, it will go into Priming mode, indicated by “ .” Please see the M-7 Installation Instruction Manual
for complete instructions on Power-up and Pump Priming. The Priming mode will last for less than 5 minutes (press “Warm” or
“Cool” to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode.
Mode
Mode is changed by pressing the “Warm” or “Cool” button, then
pressing the “Mode” button.
Standard Mode is programmed to maintain the desired
temperature. Note that the last measured spa temperature
displayed is current only when the circ pump has been running
for at least 2 minutes. “ ” will be displayed momentarily
when you switch into Standard Mode.
Economy Mode heats the spa to the set temperature only
during filter cycles. “ ” will display solid when temperature
is not current, and will alternate with temperature when
temperature is current.
Sleep Mode heats the spa to within 20°F/10°C of the set
temperature only during filter cycles. “ ” will display
solid when temperature is not current, and will alternate with
temperature when temperature is current.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is energized.
The second filter cycle begins 12 hours later. Filter duration is
programmable for 2, 4, 6, 8 hours or for continuous filtration
(indicated by “ ”). The default filter time is 2 hours.
To program, press “Warm” or “Cool”, then “Jets 1”.
Press “Warm” or “Cool” to adjust. Press “Jets 1” to
exit programming.
At the beginning of each filter cycle the blower purges for
30 seconds; the pumps purge for 5 minutes. The only effect
filter duration has is: 1) During the filter, the circ pump never
turns off, and 2) In Economy and Sleep Modes, heating only
occurs during the filter cycle.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C
within the heater, the pumps and blower will automatically
activate to provide freeze protection. The equipment stays on
until 4 minutes after the sensors detect that the spa temperature
has risen to 45°F/7.2°C or higher. In colder climates, an
optional additional freeze sensor may be added to protect against
freeze conditions that may not be sensed by the standard sensors.
Aux freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch and without a
4-minute delay in turnoff. See your dealer for details.
Jets
Light
Warm
Cool
Mode
Jets Blower Light Heat
Jets
Light
Warm
Cool
Mode
Jets Blower Light Heat
*Actual buttons and locations may vary
VS Systems display in
°F
GS Systems display in
°C
P/N 40352_C 08/09/2006
Warning! Shock Hazard! No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer or service organization for assistance. Follow all owner’s manual power
connection instructions. Installation must be performed by a licensed electrician and all grounding connections must be properly installed.
Message
No message on display.
Power has been cut off to the spa.
Temperature unknown.
“Overheat” - The spa has shut down. One of the
sensors has detected 118°F/48°C at the heater.
“Overheat” - The spa has shut down. One of
the sensors has detected that the spa water is
110°F/43°C.
“Ice” - Potential freeze condition detected.
Spa is shut down. The sensor that is plugged into
the Sensor “A” jack is not working.
Spa is shut down. The sensor that is plugged into
the Sensor “B” jack is not working.
Sensors are out of balance. If alternating with
spa temperature, it may just be a temporary
condition. If flashing by itself, spa is shut down.
A significant difference between temperature
sensors has been detected. This could indicate a
flow problem.
Persistent low flow problems. (Displays on the
fifth occurrence of “ ” message within
24 hours.) Heater is shut down, but other spa
functions continue to run normally.
Possible inadequate water, poor flow, or air
bubbles in detected in the heater. Spa is shut
down for 15 minutes.
Inadequate water detected in heater. (Displays on
third occurrence of “ ” message.) Spa is
shut down.
The control panel will be disabled until power returns. Spa
settings will be preserved until next power up.
After the pump has been running for 2 minutes, the
temperature will be displayed.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. Once the heater has cooled, reset by
pushing any button. If spa does not reset, shut off the power to
the spa and call your dealer or service organization.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. At 107°F/42°C, the spa should
automatically reset. If spa does not reset, shut off the power to
the spa and call your dealer or service organization.
No action required. The pump and blower will automatically
activate regardless of spa status.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat situation
and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat situation
and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization.
Check water level in spa. Refill if necessary. If the water level
is okay, make sure the pumps have been primed. If problem
persists, contact your dealer or service organization.
Follow action required for “ ” message. Heating capability
of the spa will not reset automatically; you may press any
button to reset.
Check water level in spa. Refill if necessary. If water level is
okay, make sure the pumps have been primed. Press any button
to reset, or this message will automatically reset within
15 minutes. If problem persists, contact your dealer or service
organization.
Follow action required for “ ” message. Spa will not
automatically reset. Press any button to reset.
Meaning Action Required
Diagnostic Messages

This manual suits for next models

1

Other Balboa Control System manuals

Balboa CHROMAZONE User manual

Balboa

Balboa CHROMAZONE User manual

Balboa BP100UX User manual

Balboa

Balboa BP100UX User manual

Balboa Balboa VS300 User manual

Balboa

Balboa Balboa VS300 User manual

Balboa Revolution Installation guide

Balboa

Balboa Revolution Installation guide

Balboa MLM990S User manual

Balboa

Balboa MLM990S User manual

Balboa VS523DZ User manual

Balboa

Balboa VS523DZ User manual

Balboa 300F User manual

Balboa

Balboa 300F User manual

Balboa BP600 User manual

Balboa

Balboa BP600 User manual

Balboa GS100 User manual

Balboa

Balboa GS100 User manual

Balboa BP600 User manual

Balboa

Balboa BP600 User manual

Balboa GS523DZ Parts list manual

Balboa

Balboa GS523DZ Parts list manual

Balboa Hydro Air 20-0244 User manual

Balboa

Balboa Hydro Air 20-0244 User manual

Balboa TP600 User manual

Balboa

Balboa TP600 User manual

Balboa VS520DZ User manual

Balboa

Balboa VS520DZ User manual

Balboa 300F Series User manual

Balboa

Balboa 300F Series User manual

Balboa BP1600 User manual

Balboa

Balboa BP1600 User manual

Balboa VS504SZ User manual

Balboa

Balboa VS504SZ User manual

Balboa 300F Series User manual

Balboa

Balboa 300F Series User manual

Balboa VS501Z User manual

Balboa

Balboa VS501Z User manual

Balboa Deluxe Digital Control User manual

Balboa

Balboa Deluxe Digital Control User manual

Popular Control System manuals by other brands

Memsic DMU380SA Series user manual

Memsic

Memsic DMU380SA Series user manual

Giltrap Generation II RF Instructions, Operating, Installation

Giltrap

Giltrap Generation II RF Instructions, Operating, Installation

Rinnai MSB-C2 installation instructions

Rinnai

Rinnai MSB-C2 installation instructions

Carson Reflex Wheel X2 instruction manual

Carson

Carson Reflex Wheel X2 instruction manual

Intermatic T51211BC supplementary guide

Intermatic

Intermatic T51211BC supplementary guide

Imesa MCA 1500 manual

Imesa

Imesa MCA 1500 manual

CIAT PRO-DIALOG+ instruction manual

CIAT

CIAT PRO-DIALOG+ instruction manual

Rotel RR-700 owner's manual

Rotel

Rotel RR-700 owner's manual

Purelogic THC1-M Connection and set up manual

Purelogic

Purelogic THC1-M Connection and set up manual

Watts OneFlow OFPSYS EU Installation and operation manual

Watts

Watts OneFlow OFPSYS EU Installation and operation manual

Burkert 8644 AirLINE operating instructions

Burkert

Burkert 8644 AirLINE operating instructions

Cleveland HA-SE-CC Specifications

Cleveland

Cleveland HA-SE-CC Specifications

Binsfeld TorqueTrak 9000 user manual

Binsfeld

Binsfeld TorqueTrak 9000 user manual

HTD Whole-House Audio Control owner's manual

HTD

HTD Whole-House Audio Control owner's manual

CAME FA01584M4A quick start guide

CAME

CAME FA01584M4A quick start guide

BeaconMedaes Manfiold Operation and maintenance instructions

BeaconMedaes

BeaconMedaes Manfiold Operation and maintenance instructions

Isuzu 4HL1 Workshop manual

Isuzu

Isuzu 4HL1 Workshop manual

iAIRE ION KIT Series manual

iAIRE

iAIRE ION KIT Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.