I/O Modbus Holding Register I/O Type I/O Range Holding Register
Representation (Dec.)
Color #
Gateway Any Node Min. Max. Min. Max.
7 7 7 + (Node# × 16) Reserved
8 8 8 + (Node# × 16) Device Message
9 9 9 + (Node# × 16) Discrete OUT 9 / Bit-picked outputs 0 1 0 1 C1
10 10 10 + (Node# × 16) Discrete OUT 10 0 1 0 1 C2
11 11 11 + (Node# × 16) Discrete OUT 11 0 1 0 1 C3
12 12 12 + (Node# × 16) Discrete OUT 12 0 1 0 1 C4
13 13 13 + (Node# × 16) Discrete OUT 13 0 1 0 1 C5
14 14 14 + (Node# × 16) Discrete OUT 14 / Zero out (clear) the counter 0 1 0 1 -
15 15 15 + (Node# × 16) Control Message
16 16 16 + (Node# × 16) Reserved
Use the User Configuration Tool (UCT) software to define unique synchronous flash patterns for the lights.
Specifications
EZ-LIGHT K70
Supply Voltage and Current
12 to 30 V DC (Outside the USA: 12 V DC to 24 V DC, ± 10%) 1
Indicators - Maximum current per LED color:
Blue, Green, White: 200 mA at 12 V DC; 90 mA at 30 V DC
Red, Yellow: 150 mA at 12 V DC; 75 mA at 30 V DC
900 MHz Consumption: Maximum current draw is < 40 mA and typical
current draw is < 30 mA at 24 V DC. (2.4 GHz consumption is less.)
Supply Protection Circuitry
Protected against transient voltages
Indicator Response Time
Off Response: 150 µs (maximum) at 12 to 30 V DC
On Response: 180 ms (maximum) at 12 V DC; 50 ms (maximum) at 30 V DC
Construction
Base and cover: polycarbonate
Segment Lumens
Color Typical Wavelength or
Color Temp Typical Intensity (lm)
Green 525 nm 65
Red 625 nm 34
Yellow 590 nm 22
Blue 470 nm 22
White 5000 K 87
Indicators
1 to 5 colors depending on model: Green, Red, Yellow, Blue, and White
Connections
5-pin M12/Euro-style quick disconnect, 8-pin M12/Euro-style quick
disconnect, 150 mm (5.9 in) PVC cable with an M12/Euro-style quick
disconnect, or 2 m (6.5 ft) unterminated cable, depending on model
Operating Conditions
–40 °C to +50 °C (–40 °F to +122 °F)
95% at +50 °C maximum relative humidity (non-condensing)
Environmental Rating
IEC IP65
Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC
60068-2-6
Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27
Certifications
(CE approval only
applies to 2.4 GHz
models)
(NOM approval only
applies to 900 MHz
models)
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance with
local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Supply Wiring (AWG) Required Overcurrent Protection (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
1For European applications, power this device from a Limited Power Source as defined in EN 60950-1.
EZ-LIGHT®K70 Wireless Indicator Light
P/N 192534 Rev. D www.bannerengineering.com - Tel: + 1 888 373 6767 7