Supply Voltage
12 V DC to 30 V DC
Supply Current
80 mA maximum current at 12 V DC
35 mA typical at 24 V DC
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Operating Conditions
–40°Cto+45°C(–40°Fto+113°F)
Humidity:90% at +50 °C maximum relative humidity (non-
condensing)
Storage Temperature:–40°Cto+70°C(–40°Fto+158°F)
Environmental Rating
IP65,IP67,IP68,UL Type 1
Construction
Coupling Material: Nickel-plated brass
Connector Body: PVC diffuse white
VibrationandMechanicalShock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55
Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell)
Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms
duration, half sine wave)
Connections
Integral 4-pin M12 male/female quick-disconnect connector
Models with a quick disconnect require a mating cordset
Required Overcurrent Protection
WARNING: Electrical connections must
be made by qualified personnel in
accordance with local and national
electricalcodesandregulations.
Overcurrent protection is required to be provided by end
productapplicationperthesuppliedtable.
Overcurrent protection may be provided with external fusing
or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go
towww.bannerengineering.com.
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
20 5.0 26 1.0
22 3.0 28 0.8
24 1.0 30 0.5
Default Indicator Characteristics
Color
Dominant
Wavelength
(nm) or Color
Temperature
(CCT)
Color
Coordinates(1) Lumen
Output
(Typical at
25 °C)
x y
White 7000K 0.31 0.295 1.16
Green 527 0.175 0.7 1.8
Red 620 0.69 0.307 1.3
Orange 604 0.628 0.356 1.35
Amber 597 0.593 0.383 1.35
Yellow 588 0.537 0.426 1.35
Lime
Green 577 0.466 0.481 1.8
Spring
Green 513 0.178 0.562 1.6
Cyan 498 0.195 0.396 1.3
Sky Blue 489 0.17 0.303 1.1
Blue 465 0.144 0.055 0.25
Violet - 0.337 0.144 0.7
Magenta - 0.506 0.251 1
Rose - 0.593 0.282 1.1
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
(1) Refer to the CIE 1931 (x,y) Chromaticity Diagram to show equivalent
color with indicated color coordinates. Actual coordinates may differ ± 5%.
Specifications