The Outdoor Illuminated Touch Timer
(3 wire) is part of the Elkay family of switches,
timers and detectors which save energy
and increase convenience in and around
your home, garden or premises.
Rating at 240V ac
• All load types 16A
• Time Delay: 2 min - 2 hrs
• Featherlight touch
• Re-trigger function
• Blue Locator ring
• IP66
Usage
The touch sensor is a general purpose time control.
Applications for suitable use include lighting,
heating and ventilation. The timers can be used
independently or as a master unit when using
Activator trigger switches.
Mounting and Installation
IMPORTANT Please note that it is essential
that the Live In wire and switch Live Out
is identifi ed prior to commencing installation. Turn
off mains supply for installation. Your Elkay unit is
compatible with a single gang, 25mm deep, British
Standard accessory plate. Please ensure that
the top and bottom lugs are removed, if fi tted,
from metal wall boxes prior to fi tting. Ensure that
there is adequate space for wiring.
Step 1
Place the Live In wire into the left hand
position of the connector, the switched Live Out
–
OUTDOOR
ILLUMINATED
TOUCH TIMER
560A-1
3 wire
Instruction Guide
BROOK DESIGN HARDWARE LTD
BDH
BDH
BROOK DESIGN
HARDWARE LTD
BDHBROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
BDH
wire into the second from left position of the
connector and neutral into right hand position of
connector (see diagram 1).
Step 2
Set the timing as per timing table (see diagram 2).
The black square illustrates where the dip switch
should be situated. For example:
10min 1 = OFF, 2 = ON, 3 = OFF, 4 = OFF
Step 3
Re-apply mains supply. The blue locator ring will light
up around the touch pad. Your light source or
appliance, will now be switched off . Please refer to
operation section.
Outdoor Installation
Outdoor Unit can only be used in conjunction with
the surface mount box supplied. Take the surface
mount box and remove the knock out section.
It is recommend the hole is cut with a 20mm hole
saw for cleanest eff ect. If required and to ensure
IP66 waterproof rating, please use a suitable M20
cable gland use appropriate sealing washers.
Mount the surface mount box on a secure surface
using the mounting pack supplied. Place screw
cover seals over the mounting screws. It is essential
that the correct IP 66 rated connections are made
to keep the integrity of the IP rated back box
maintained. Mount timer unit onto surface mount
box using the four screws at all four corners ensuring
even connection with the seal-Place screw cover
seals over left and right screw cavities. Clip on front
fascia plate.
Continued overleaf...
Brook House,
Dunmurry Industrial Estate,
Dunmurry,
Belfast BT17 9HU
T +44 (0)28 9061 6505
F +44 (0)28 9061 6518
E info@elkay.co.uk elkay.co.uk
BROOK DESIGN HARDWARE LTD
BDH
B
DH
BROOK DESIGN
HARDWARE LTD
BDHBROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
BDH
Technical Helpline
For further help or assistance or information on this or other products in the range
please call the Elkay Technical team on +44 (0)28 9061 6505. Please call the
Technical helpline before returning any products to your stockist. These
instructions
are available in other languages. Please refer to our website www.elkay.co.uk
Instrukcje są również dostępne w innych językach. Prosimy o zapoznanie się z naszą
stroną internetową www.elkay.co.uk lub www.elkaypolska.pl
Important Notice
All wiring should be carried out by a competent
person or a qualifi ed electrician and should be
fi tted to current IEE wiring regulations BS 7671.
The circuit should be isolated before carrying out
any work. Failure to adhere to the instructions
will invalidate the warranty.
Elkay (Europe), 51C Milicka, Trzebnica, 55-100, Poland
Diagram 1 Diagram 2 – Time settings
Please note:
The black bar denotes
the position of the dip switch.
Flexible Cable – It is always better to use cable
glands with fl exible cable, with the gland connected
at the bottom, rather than through the top.
Ensure sealing washers are used with all connections
and all glands and connections are done up
tightly with a spanner to ensure water tightness.
SWA Glands – SWA glands can be used but must
be IP rated. The IP rating for the SWA gland
guarantees only the connections to the SWA cable.
You will still need a nylon sealing washer to
maintain the IP rating from the gland to the switch
housing back box. As a general rule, nylon washers
work best with this type of application. Rubber
washers can deform when used with metal glands.
Connections must be done up tightly with a
spanner to ensure water tightness.
Operation of the Unit
1. Press the push button/touch pad and the red
LED light up briefl y. Your light source or appliance
will now be switched on.
2. At any time during the working of the light source
or appliance, the push button/touch pad can be
pressed to reset the timing sequence to the
originally set time, e.g. when the timing period
is 30 minutes, if push button/touch pad is
pressed 15 minutes into the sequence, the timer
will re-set for a further 30 minutes.
3. To end the timing sequence prematurely, press
and hold the push button/touch pad until the
red LED fl ashes continuously indicating the last
minute of operation. Your light source or appliance
will be switched off , after one minute.
4. At one minute prior to the end of the timing
sequence, the red LED will begin to fl ash
continuously for the last minute of operation.
The blue locator ring will then illuminate once
the light source or appliance has gone off .
LIVE IN
NEUTRAL
LIVE OUT
5 - 7m
4 - 6m
5 - 7m
3 - 4m
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
7 metres approx.
2.4 metres
7 metres approx.
CEILING
FLOOR
LIVE IN
NEUTRAL
LIVE OUT
LIVE IN
LIVE OUT
Battery
LIVE IN
LIVE OUT
DIL
switches
Battery
NEUTRAL
2 mins 5 mins 10 mins 15 mins 20 mins 25 mins 30 mins 40 mins
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
50 mins 60 mins 70 mins 80 mins 90 mins 100 mins 110 mins 120 mins
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1

Other BDH Timer manuals

BDH Elkay 550A-1 Manual

BDH

BDH Elkay 550A-1 Manual

BDH Elkay 3875A-1 Manual

BDH

BDH Elkay 3875A-1 Manual

BDH Elkay 570A-1 Manual

BDH

BDH Elkay 570A-1 Manual

BDH Elkay 370A-1 Manual

BDH

BDH Elkay 370A-1 Manual

BDH Elkay 370B-1 Manual

BDH

BDH Elkay 370B-1 Manual

BDH Elkay 376A-1 Manual

BDH

BDH Elkay 376A-1 Manual

BDH Elkay 380A-1 Manual

BDH

BDH Elkay 380A-1 Manual

BDH Elkay Columbus 400NE Manual

BDH

BDH Elkay Columbus 400NE Manual

BDH Elkay 376B-1 Manual

BDH

BDH Elkay 376B-1 Manual

Popular Timer manuals by other brands

Emos ESI2001 manual

Emos

Emos ESI2001 manual

ALGE-Timing TIMY2 Manual General

ALGE-Timing

ALGE-Timing TIMY2 Manual General

Rosendahl mif 4 instruction manual

Rosendahl

Rosendahl mif 4 instruction manual

Everflourish EMW2600TS instruction manual

Everflourish

Everflourish EMW2600TS instruction manual

Leviton TS300 installation instructions

Leviton

Leviton TS300 installation instructions

Gemo DZ307 quick start guide

Gemo

Gemo DZ307 quick start guide

TAG Heuer POCKET PRO ATHLETICS HL400-A user manual

TAG Heuer

TAG Heuer POCKET PRO ATHLETICS HL400-A user manual

SBC KOP EX Series instructions

SBC

SBC KOP EX Series instructions

Black & Decker BDXPA0021 instruction manual

Black & Decker

Black & Decker BDXPA0021 instruction manual

Woods TD1000 instructions

Woods

Woods TD1000 instructions

Century BND-60/U78 manual

Century

Century BND-60/U78 manual

VWR 62344-641 instruction manual

VWR

VWR 62344-641 instruction manual

Honeywell 46213 quick start guide

Honeywell

Honeywell 46213 quick start guide

MULTISPAN UTR-413 operating manual

MULTISPAN

MULTISPAN UTR-413 operating manual

aldes 29 023 Installation operation & maintenance

aldes

aldes 29 023 Installation operation & maintenance

CDI T4 instructions

CDI

CDI T4 instructions

Sunlite T400 instruction manual

Sunlite

Sunlite T400 instruction manual

Anslut 006052 operating instructions

Anslut

Anslut 006052 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.