Technical data
14 RFID110-L1_D00283_02_M_XXEN/04.2018
3. Technical data
3.1 Tabular data
Insulation coordination acc. to IEC 60664-1/IEC 60664-3
Rated voltage ........................................................................................................................................................ 12.5 V
Overvoltage category.....................................................................................................................................................III
Pollution degree .............................................................................................................................................................3
Rated impulse withstand voltage...........................................................................................................................800 V
Rated insulation voltage........................................................................................................................................12.5 V
Altitude..................................................................................................................................................≤ 2000 m AMSL
Nominal voltage/nominal current
Nominal voltage..............................................................................................................................................DC 3.3/5 V
Nominal voltage tolerance .................................................................................................................................... ±5 %
Nominal current.............................................................................................................................................140/64 mA
Frequency
Radio frequency ..............................................................................................................................................13.56 MHz
Environment/EMC
Operating temperature ........................................................................................................................... -30…+70 °C
Climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ............................................3K5 (except condensation, water and formation of ice)
Transport (IEC 60721-3-2) ....................................................................................................................................... 2K2
Long-term storage (IEC 60721-3-1) ........................................................................................................................ 1K2
Mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ..............................................................................................................................3M4
Transport (IEC 60721-3-2) ......................................................................................................................................2M2
Long-term storage (IEC 60721-3-1) .......................................................................................................................1M3
Connection
Connection to charge controller................................................................................................................via RJ45 cable
Maximum cable length..........................................................................................................................................< 3 m
Other
Protection class ......................................................................................................................................................... IP00
Maximum read distance.....................................................................................................................................100 mm
Weight....................................................................................................................................................................... 25 g