Performance comparison between traditional battery charger and intelligent battery charger
Traditional battery chargers
The first
stage
Charge the battery to 80% capacity
The charger first automatically
detects the battery and automatically
identifies 12V or 24V. If the battery is
normal, it will enter the normal
charging mode after 2 minutes and
charge the battery to 80% capacity.
The second
stage
A large amount of current ACTS on the
electrolyte, causing a large number of
bubbles. The voltage shows that it has
reached the standard value (Has been full
of), but the actual capacity is still 80%,
and since it is still charged with a large
current, polarization phenomenon
(overcharging phenomenon) starts to
CPU microcomputer chip control,
automatic from constant current to
constant voltage, small current
continue to charge to 95% capacity,
avoid gasification phenomenon in the
protection plate.
The third
stage
Need to cut off the power supply
artificially, or it will appear overcharge
phenomenon, shorten the service life of
the battery, serious will lead to battery
scrap.
CPU microcomputer chip control,
automatically from constant voltage
to constant current, continue to
charge to 100% capacity with small
current, complete the whole charging
process, automatically stop charging,
there will be no overcharge
Low battery
Such as the battery serious loss of power
(over discharge), direct use of large
current charge will damage the plate,
even if the voltage display has been
full,In fact, the virtual power, used for a
while on the power, seriously shorten the
battery life.
Automatically determine battery
status
If the battery is found to be out of
power, it will be charged
automatically with a small current
until the battery returns to normal,
and then charged in normal charging
mode.
This function can protect and repair
the battery, prolong the service life.
Battery
failure or
improper use
Damage to battery and charger.
The charger can automatically detect
battery failure, positive and negative
polarity reverse connection, short
circuit, battery lack of case and other
phenomena, and sound and light
flashing alarm.
220-240VAC 50-60Hz,variable power , 1.5A,,250W Max
6VDC, 2A/5A; 12VDC, 2A/5A/10A; 12VDC, 15A, 300s (Boost); Temperature Controlled.
6 steps, Full-automatic Charging Cycle.
All type of 12V lead-acid batteries (WET/MF/EFB/GEL/AGM...)
Cable Clamps, and 12V SUPPLY Cigarette Lighter Outlet.