Busch-Jaeger Busch-Infoline 1510 UC User manual

1473
-1-8174 │ Rev. 01 │ 17.12.2012
Operating Instructions
Busch
-Infoline®
Pos: 2 /#Neustruktur#/ Online-Dokumentatio n (+KNX)/Titelbl ätter/Infoline/ Titelblatt - 1510 @ 25\mod_13 39651633537_15.doc x@ 21733 7 @ @ 1
1510 UC
Handicapped WC signal set
=== Ende der Liste für Textmarke Co ver ===

Operating Instructions
Busch-Infoline®
Operating Instructions | 1473-1-8174
— 2 —
Pos: 4 /#Neustruktur#/ Online-Dokumentatio n (+KNX)/Inhaltsver zeichnis (--> Für alle Dokume nte <--)/Inhaltsverzeic hnis @ 19\mod_1320649044386_ 15.docx @ 109653 @ @ 1
1Safety.......................................................................................................................................................................3
2Intended use............................................................................................................................................................3
3Environment.............................................................................................................................................................3
4Operation.................................................................................................................................................................4
5Technical data..........................................................................................................................................................5
6Setup and function...................................................................................................................................................6
6.1 Features of function and equipment........................................................................................................6
6.2 Possible combinations ............................................................................................................................7
7Installation and electrical connection .......................................................................................................................8
7.1 Requirements for the electrician .............................................................................................................8
7.2 Electrical connection...............................................................................................................................9
7.3 Mounting of device inserts ....................................................................................................................11
7.4 Setting alarm behaviour with jumper.....................................................................................................12
7.5 Setting confirmation feedback signal with jumper .................................................................................12
=== Ende der Liste für Textmarke TOC ===

Operating Instructions
Busch-Infoline®
Safety
Operating Instructions | 1473-1-8174
— 3 —
Pos: 6 /#Neustruktur#/ Online-Dokumentatio n (+KNX)/Überschr iften (--> Für alle Doku mente <--)/1. Ebene/S - T/Sic herheit @ 18\mod_130261279179 0_15.docx @ 103357 @ 1 @ 1
1 Safety
Pos: 7 /#Neustruktur#/ Online-Dokumentatio n (+KNX)/Sicher heitshinweise und Hinweise ( --> Für alle Dokumente <--)/W arnhinweise/Sicherheit - 230 V @ 18\mod_13026068 16750_15.docx @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 8 /#Neustruktur#/ Online-Dokumentation (+K NX)/Sicherheitshin weise und Hinweise (--> Für alle Doku mente <--)/Warnhinweise/Si cherheit - Schalldruc k 70 dB @ 25\mod_1341379636575_15. docx @ 222233 @ @ 1
Warning
High sound pressure level!
High sound pressure level of 70 dB at a distance of 1 m. Problems with concentration are possible
in this area.
- Safety distance must be adhered to!
Pos: 9 /#Neustruktur#/ Online-Dokumentatio n (+KNX)/Überschr iften (--> Für alle Doku mente <--)/1. Ebene/A - F/Besti mmungsgemäßer Gebrauch @ 18\mod_130276332 1316_15.docx @ 103483 @ 1 @ 1
2 Intended use
Pos: 10 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Bestimmungsg emäßer Gebrauch (--> Für alle Dokumen te <--)/Busch-Dimmer/Bes timmungsgemäßer Gebrauc h @ 23\mod_1335350449857_1 5.docx @ 208763 @ @ 1
The device is to be used exclusively with the components that are supplied and licensed as described in chapter
"Setup and function".
Pos: 11 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Überschr iften (--> Für alle Dokumente <--)/ 1. Ebene/U - Z/ Umwel t @ 18\mod_130261415 8967_15.docx @ 103383 @ 1 @ 1
3 Environment
Pos: 12 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sicher heitshinweise und Hinweise ( --> Für alle Dokumente <--)/Hinweis e - Umwelt /Hin weis - Umwelt - Hinweis Elek trogeräte @ 18\mod_130276 3973434_15.docx @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste.
– The device contains valuable raw materials which can be recycled. Therefore, dispose of the
device at the appropriate collecting depot.
Pos: 13 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sicher heitshinweise und Hinweise ( --> Für alle Dokumente <--)/Hinweis e - Umwelt /Hin weis - Umwe lt - Entsorgung Elektro geräte @ 20\mod_1325760695 972_15.docx @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the
packaging material and electric devices and their components via the authorized collecting depots and disposal
companies.
The products meet the legal requirements, in particular the laws governing electronic and electrical devices and
the REACH ordinance.
(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos: 14 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Steuermodu le - Online -Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_12688 98668093_0.doc x @ 52149 @ @ 1

Operating Instructions
Busch-Infoline®
Operation
Operating Instructions | 1473-1-8174
— 4 —
Pos: 15 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Überschr iften (--> Für alle Dokumente <--)/ 1. Ebene/A - F/Bedienung @ 11\mod_1279185 541649_15.doc x@ 83043 @ 1 @ 1
4 Operation
Pos: 16 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Bedienung/ Infoline/Bedienun g 1510 @ 25\mod_1341314575373_1 5.docx @ 221074 @ @ 1
Triggering an emergency call
1. With the button
- By pressing the emergency call button an alarm message is triggered in the form of a continuous audible
signal and a flashing signal light outside the toilet.
2. With the pullcord
– By pulling the pullcord in the toilet the same alarm message is triggered outside.
The LED (comforting light) integrated in the signal button indicates to the person needing help that her/his call
has been recognized and that help is on the way.
Acknowledging the alarm message
By pressing the cancel button the alarm is acknowledged and the comforting light as well as the acoustic and
optical signal go out.
Pos: 17 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Steuermodu le - Online -Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_12688 98668093_0.doc x@ 52149 @ @ 1

Operating Instructions
Busch-Infoline®
Technical data
Operating Instructions | 1473-1-8174
— 5 —
Pos: 18 /#Neustruktur #/Online-Dokumenta tion(+ KNX)/Überschrif ten( --> Für alle Dokumente <--)/1. Ebene/ S -T/Tec hnische Daten @ 11\mod_127918 5386320_15.docx @ 83019 @ 1 @ 1
5 Technical data
Pos: 19 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Technisc he Daten/Infoline/ Technische Daten - 1510 @ 25\mod_133965 1670343_15.doc x@ 2173 52@ @ 1
General
Nominal voltage 230 V AC, ±10%, 50 / 60 Hz
Nominal current 110 mA AC / 60 mA DC
Output current 15 V AC (SELV) / 150 mA DC
Power loss 2000 mW
Loop current 5 mA
Tripping delay 0.1 s
Sound frequency 2300 Hz
Sound pressure 70 dB / 1 m
Protection class IP 20
Operating temperature range 5 ... 40 °C
Switching contacts
Normally open contact 1 A, 30 VA / W, potential-bound
Changeover contact 40 V AC / 60 V DC, 30 VA / W, floating
Pos: 20 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Steuermodu le - Online -Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_12688 98668093_0.doc x@ 52149 @ @ 1

Operating Instructions
Busch-Infoline®
Setup and function
Operating Instructions | 1473-1-8174
— 6 —
Pos: 21 /#Neustruktur #/Online-Dokumentation (+K NX)/Überschrif ten( --> Für alle Dokumente <--)/1. Ebene/ A -F/ Aufbau und Funktion @ 11\mod_1279185 435352_15.docx @ 83027 @ 1 @ 1
6 Setup and function
Pos: 22 /#Neustruktur #/Online-Dokumentation(+ KNX)/Überschrif ten( --> Für alle Dokumente <--)/2. Ebene/ A -F/ Funktions-und Au sstattungsmerk male @ 23\mod_133655763014 0_15.docx @ 209136 @ 2 @ 1
6.1 Features of function and equipment
Pos: 23 /#Neustruktur #/Online-Dokumentation (+K NX)/Aufbau und Funktion/I nfoline/Funktione n - 1510 @ 25\mod_1339651702503_1 5.docx @ 217368 @ @ 1
The call set serves for setting up an emergency call system in WCs for the handicapped.
The set consists of a power supply insert, alarm signal insert, signal button insert with pullcord, and cancel-button
insert.
Power supply insert
Serves for the short-circuit proof power supply of call and alarm systems.
Alarm signal insert
Serves for setting up call and alarm systems and for monitoring a current loop for interruption or short-circuit. The
insert additionally offers an alarm status storage with a switch-off function. Once an alarm has been triggered,
there is a continuous acoustic alarm and a pulsating optical alarm.
Signal button insert with pullcord
Used for activating alarm signals with a pullcord, e.g. in a WC for the handicapped.
Cancel button insert
Used or deactivating signal / alarm messages of various types via a pilot LED.
Pos: 24 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Steuermodu le - Online -Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_12688 98668093_0.doc x@ 52149 @ @ 1

Operating Instructions
Busch-Infoline®
Setup and function
Operating Instructions | 1473-1-8174
— 7 —
Pos: 25 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Überschr iften (--> Für alle Dokumente <--)/ 2. Ebene/G - L/Kombina tionsmöglichkeiten @ 19\mod_1320312 769153_15.doc x@ 109520 @ 2 @ 1
6.2 Possible combinations
Pos: 26 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Kombinati onsmöglichkeiten/I nfoline/Kombina tionsmöglichkeit en - 1510 @ 25\mod_1339651738678_15. docx @ 217384 @ @ 1
Call set
1510 UC
1511 U
X
1539 U
X
1563 U-12
X
1561 U
X
1564 U-1X
X
1566 U
X
1520/1 UK
X
1520/1 UKZ
X
Pos: 27 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Steuermodu le - Online -Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_12688 98668093_0.doc x@ 52149 @ @ 1

Operating Instructions
Busch-Infoline®
Installation and electrical
connection
Operating Instructions | 1473-1-8174
— 8 —
Pos: 28 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Überschr iften (--> Für alle Dokumente <--)/1. Ebene/M - O/Montag e und elektrischer Ansc hluss @ 23\mod_1336477157864_15. docx @ 209033 @ 1 @ 1
7 Installation and electrical connection
Pos: 29 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sicher heitshinweise und Hinweise ( --> Für alle Dokumente <--)/W arnhinweise/Sicher heit - Niederspannungs- und 230 V-Lei tungen @ 23\mod_133655886820 1_15.docx @ 209164 @ @ 1
Warning
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
– Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!
Pos: 30 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sicher heitshinweise und Hinweise ( --> Für alle Dokumente <--)/W arnhinweise/Sicher heit - Fachkenntnisse @ 23\mod_1336 559183027_15.doc x@ 209 179@ 2 @ 1
7.1 Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
• Incorrect installation endangers your life and that of the user of the electrical system.
• Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
• Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth and short-circuit;
5. Cover or barricade adjacent live parts.
• Use suitable personal protective clothing.
• Use only suitable tools and measuring devices.
• Check the supply network type (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos: 31 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Steuermodu le - Online -Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_12688 98668093_0.doc x@ 52149 @ @ 1

Operating Instructions
Busch-Infoline®
Installation and electrical
connection
Operating Instructions | 1473-1-8174
— 9 —
Pos: 32 /#Neustruktur #/Online-Dokumentation (+K NX)/Überschrif ten( --> Für alle Dokumente <--)/2. Ebene/ A -F/ Elektrischer Anschluss @ 21\mod_ 1328177051724_15.doc x @ 138042 @ 2 @ 1
7.2 Electrical connection
Pos: 33 /#Neustruktur #/Online-Dokumentati on (+KNX)/Anschluss/I nfoline/Anschl uss - 1510 @ 25\mod_1339651803409_15. docx @ 217400 @ @1
Connection diagram
Fig. 1: Circuit diagram
1Separate installation box | 2Protective insulation | 3Power supply insert | 4Alarm message insert |
5Cancel button insert | 6Signal button insert with pullcord | 7terminal resistor
Terminal assignment
1518 U power supply insert
Terminal designation Assignment
L 230 V AC, ±10%, 50 / 60 Hz
N
~ AC 15 V AC
1515 U-12 Alarm indicator insert
Terminal designation
Assignment
<- 15 V AC power supply
<-
14
Changeover contact, floating, 42 V AC / 60 V DC, 30 W / VA11
12
4 Normally open contact, potential-bound
3
2 Signal input
1
R Reset input

Operating Instructions
Busch-Infoline®
Installation and electrical
connection
Operating Instructions | 1473-1-8174
— 10 —
1520/1 UK / 1520/1 UKZ
Signal / cancel button insert / signal button insert with pullcord
Terminal designation Assignment
1 Normally open contact, floating, 30 V AC / 35 V DC, 100 mA
2
3 Signal / control display via LED (UK)
Comforting light and control display via LED (UKZ)
4
Note
The call system can easily be extended by further signal buttons if required.
Pos: 34 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Steuermodu le - Online -Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_12688 98668093_0.doc x@ 52149 @ @ 1

Operating Instructions
Busch-Infoline®
Installation and electrical
connection
Operating Instructions | 1473-1-8174
— 11 —
Pos: 35 /#Neustruktur #/Online-Dokumentation (+K NX)/Überschrif ten( --> Für alle Dokumente <--)/2. Ebene/M - O/Montage der Geräteei nsätze @ 25\mod_13413070102 49_15.docx @ 220967 @ 2 @ 1
7.3 Mounting of device inserts
Pos: 36 /#Neustruktur #/Online-Dokumentation (+ KNX)/Montage/Infoline/ Montage -Geräte Einsätze 151 0 @ 25\mod_1339653111462_ 15.docx @ 217416 @ @ 1
It should preferably be mounted next to the door of the WC.
1. Mount the devices in a flush-mounted box according to DIN 049073-1.
2. Fix the devices in the flush-mounted box with screws.
3. Bundle the wires of the mains cable (230 V) with the cable binders included in the scope of supply (Fig. 2: b).
4. Push the low-voltage lines through the insulating tube included in the scope of supply (Fig. 2: a).
5. Connect the terminal resistor to terminals 1 and 2 of the signal button insert that is installed furthest from the
alarm signal insert.
6. Mount the elements of the cover plate in the sequence shown in the illustration.
Fig. 2: 1518 U power supply insert
Fig. 3: 1520/1 UKZ cover plate for signal button insert with pullcord
Fig. 4: 1515 U-12 cover plate for alarm signal insert
Pos: 37 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Steuermodu le - Online -Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_12688 98668093_0.doc x@ 52149 @ @ 1

Operating Instructions
Busch-Infoline®
Installation and electrical
connection
Operating Instructions | 1473-1-8174
— 12 —
Pos: 38 /#Neustruktur#/ Online-Dokumentation ( +KNX)/Überschri ften (--> Für alle Dokumente <--)/2. Ebene/A - F/ Alarmverhalten mit Stec kbrücke einstellen @ 25\mod_1 341307557695_15.doc x@ 2210 23 @ 2@ 1
7.4 Setting alarm behaviour with jumper
Pos: 39 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Montage/I nfoline/Alarmverha lten 1510 (1515 U) @ 25\mod_1341 307588913_15.doc x@ 221037 @ @ 1
Fig. 5: 1515 U-12 Alarm indicator insert
Position Alarm behaviour
- Without storage of the alarm status
M With storage of the alarm status
Pos: 40 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Überschr iften (--> Für alle Dokumente <--)/ 2. Ebene/A - F/Bestätigungsr ückmeldung mit Stec kbrücke einstel len@ 25\mod_1341307 122248_15.doc x@ 220995 @ 2 @ 1
7.5 Setting confirmation feedback signal with jumper
Pos: 41 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Montage/I nfoline/Bestätig ung 1510 / 1520 @ 25\mod_134130716 0796_15.docx @ 221009 @ @ 1
Fig. 6: 1520/1 UKZ signal / cancel button insert
Fig. 7: 1520/1 UKZ signal button insert with pullcord
Position Confirmation feedback signal
B Group triggering
A Single triggering
=== Ende der Liste für Textmarke Con tent ===

Operating Instructions
Busch-Infoline®
1473-1-8174 | Rev. 01 | 17.12.2012
Pos: 43 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Rückseite n (--> Für alle Dokumente <--)Rücksei te- B usch-Jaeger -Allge mein (2013-01-03 09:23:43) @ 28\mod_1347009 779995_15.doc x@ 232282 @ 2 @ 1
A member of the ABB Group
Busch-Jaeger Elektro GmbH
PO box
58505 Lüdenscheid
Freisenbergstraße 2
58513 Lüdenscheid
Germany
www.BUSCH-JAEGER.com
info.bje@de.abb.com
Central sales service:
Phone: +49 (0) 2351 956-1600
Fax: +49 (0) 2351 956-1700
Notice
We reserve the right to at all times make
technical changes as well as changes to the
contents of this document without prior notice.
The detailed specifications agreed to at the time
of ordering apply to all orders. ABB accepts no
responsibility for possible errors or
incompleteness in this document.
We reserve all rights to this document and the
topics and illustrations contained therein. The
document and its contents, or extracts thereof,
must not be reproduced, transmitted or reused by
third parties without prior written consent by ABB.
Copyright© 2012 Busch-Jaeger Elektro GmbH
All rights reserved
=== Ende der Liste für Textmarke Bac kcover ===