BYK spectro2profiler Manual

spectro2profiler
Short Instructions
Kurzbedienungsanleitung
Instructions rapides
Istruzioni Brevi
Instrucciones resumidas
快速操作手册
簡易マニュアル
Краткая инструкция

BYK-Gardner GmbH spectro2profiler
2 283 025 449 - 2305
© Copyright 2023 BYK-Gardner GmbH
All rights reserved

spectro2profiler BYK-Gardner GmbH
Table of Contents
English .............................................................................................. 4
Deutsch............................................................................................. 14
Français............................................................................................. 24
Italiano ............................................................................................. 34
Español............................................................................................. 44
中文 ................................................................................................... 54
日本語 ............................................................................................... 64
Русский............................................................................................. 74
283 025 449 - 2305 3

spectro2profiler BYK-Gardner GmbH
4 283 025 449 - 2305
Table of Contents
1 System Description ..................................................................................................................... 5
2 Software Installation.................................................................................................................. 6
3 Main Menu................................................................................................................................... 7
4 Measurement Parameters .......................................................................................................... 8
5 Instrument Calibration ............................................................................................................... 9
6 Difference Measurement............................................................................................................ 10
7 Absolute Measurement and Quick Check ................................................................................. 11
8 Technical Data ............................................................................................................................. 12

BYK-Gardner GmbH spectro2profiler
283 025 449 - 2305 5
1 System Description
The system consists of instrument, calibration and test tiles and software for data transfer
and analysis.
• Connect instrument (1) with PC via USB cable (2).
• When connecting for the first time, instrument is automatically turned on.
• The battery pack (1) in the instrument is automatically charged.
• If instrument has switched off, turn it on by pressing the Operate button.
• Download and install smart-chart software (3).

spectro2profiler BYK-Gardner GmbH
6 283 025 449 - 2305
2 Software Installation
1. Download zip-file from:
https://www.byk-instruments.com/spectro2profiler
2. Save the file into a new folder and extract the complete archive.
3. Right mouse click on “install.exe” and select option “Run as administrator”.
4. Follow the setup instructions on the screen.
The software includes two packages:
•smart-lab for online measurements and memory transfer to PC
•smart-process for standardized quality control in the production
NOTICE
After installation smart-lab and smart-process can be used for 30 days free trial. There-
after, you need to register one of the packages.

BYK-Gardner GmbH spectro2profiler
283 025 449 - 2305 7
3 Main Menu
The following symbols are displayed by default.
12
3
4 5
1Difference
Compare standard and sample. Res-
ults are saved automatically.
2Absolute
Take absolute measurements
without comparing to a standard.
Results are saved automatically.
3Quick Check
Perform quick evaluations without
saving.
4Browse
View and delete measurement data.
5Configuration
Change measurement parameters or instrument settings and calibrate instrument.
Display of additional icons
Opacity
Activate under Configuration > Measurement Parameters > Color In-
dices.
Organizer
Download at least one organizer from smart-chart.

spectro2profiler BYK-Gardner GmbH
8 283 025 449 - 2305
4 Measurement Parameters
Go to Configuration > Measurement Parameters.
2D/3D Settings: Select algorithm to be
used - Leather-Like, Leather-Inverted,
Coarse Paint, Fine. Details see separate
Glossary.
Gloss: Turn gloss measurement and / or
difference measurement for gloss on or
off.
2D/3D Scales: Select scales to be measured
for 2D reflectivity and 3D structure ana-
lysis.
Illumination: Select standard illuminant.
Default is D65.
Color System: Select color system. Default
is CIE L*a*b*.
Observer: Select standard observer. De-
fault is 10°.
Color Equation: Select color equation.
Default is Δ E*.
Statistics: Define number of readings (n),
statistical values to be displayed and activ-
ate / deactivate the option Statistic fixed
(not more readings than (n) are possible).
Measurement Screen: Select the values
to be displayed after a measurement. De-
fault is Δ SMP (difference sample to stand-
ard).
Always use autostandard: Search for
nearest standard is always active.
Color Indices: Select color indices. Default
is none.
Always continue last test series: Latest
series is opened automatically to add new
measurement data.

BYK-Gardner GmbH spectro2profiler
283 025 449 - 2305 9
5 Instrument Calibration
The instrument comes with a calibration standard and test standard for color and gloss.
Each tile has a dedicated serial number matching your instrument. Use these tiles to mon-
itor the performance of your instrument. The instrument will guide you through the pro-
cedure.
1. Place standards and instrument on a stable base.
2. Select Configuration > Calibration > Perform diagnosis.
3. Place instrument on green color test standard and keep it steady.
4. Confirm with checkmark or press button Operate.
5. If diagnosis passes, repeat with black gloss test standard.
6. If diagnosis passes, instrument can be used to measure.
7. If diagnosis fails, clean standard and repeat procedure.
8. If diagnosis fails, click on Calibrate and follow instructions.
When the auto diagnosis interval has expired (after 4 weeks), the instrument displays a
message when it is switched on.
NOTICE
To monitor your test equipment: Tap on Add to standard list to store it as a test stand-
ard in the instrument memory und measure it in regular intervals.

spectro2profiler BYK-Gardner GmbH
10 283 025 449 - 2305
6 Difference Measurement
Search for matching standards, create new standards and compare samples to existing
standards. Results are automatically saved.
1
23
4
5
6
7
1. Select existing standard from list (1) or add a new standard.
2. To add a new standard, tap on + symbol (2).
3. Place instrument on standard.
4. To activate camera, press Operate button halfway.
5. Tap on Measure (3) or press Operate button all way through.
6. Standard is measured and automatically saved.
7. Scroll down to see data table and statistics.
4
5
6
7
8. When number of readings is reached (4), proceed with Next (5).
9. Place instrument on 1st sample and tap on Measure or press Operate.
10. Sample is measured and automatically saved (6). Proceed with next.

BYK-Gardner GmbH spectro2profiler
283 025 449 - 2305 11
7 Absolute Measurement and Quick Check
Take measurements without comparison to a standard. Results are automatically saved.
1. Place instrument on 1st sample.
2. Click on Measure or press Operate button.
3. Sample is measured and automatically saved.
4. Scroll down to see data table and statistics.
5. When number of readings per sample is reached, proceed with next sample.
Compare a standard with one or more samples without saving for a quick evaluation.
1. Place instrument on standard and measure it.
2. Continue with Next, place instrument on 1st sample and measure it.
3. Scroll down to see data table and statistics.
4. Continue with Next, place instrument on 2nd sample and measure it.

spectro2profiler BYK-Gardner GmbH
12 283 025 449 - 2305
8 Technical Data
Color Measurement
Geometry 45°c:0°
Aperture size Diameter 25 mm
Spectral range 400 - 700 nm, 10 nm resolution
Repeatability 0.01 ∆E94 (10 readings on white)
Reproducibility 0.1 ∆E94 (average of 12 BCRA tiles)
Color systems CIELab/Ch, Lab(h), XYZ, Yxy
Color differences ∆E*, ∆E(h), ∆E94, ∆ECMC, ∆E99, ∆E2000, ∆E2000PF, ∆E6175
Indices YIE313, YID1925, WIE313, WICIE, WIBerger,
Opacity, Metamerism, Gray Scale
Illuminants A, C, D50, D55, D65, D75, F2, F6, F7, F8, F10, F11, UL30
Observer 2°, 10°
Gloss Measurement
Aperture size 25 × 15 mm
Meas. range Repeatability Reproducibility
0 - 20 GU ± 0.1 GU ± 0.2 GU
20 - 100 GU ± 0.2 GU ± 1.0 GU
2D Reflectivity Measurement
Aperture size 15 × 15 mm
Measurement range 0 - 500 000,
technical performance guaranteed within 0 - 2500
Spatial resolution 60 µm
Repeatability(1) 0.5 % (10 readings on structure reference standard)
Reproducibility(1) 1.0 % (on structure reference standard)

BYK-Gardner GmbH spectro2profiler
283 025 449 - 2305 13
3D Structure Measurement (Cs, Ca)
Aperture size 15 × 15 mm
Measurement range Cell size (Cs): 0 - 255 mm2
Cell amplitude (Ca): 2 µm - 2 mm (perceived)
Spatial resolution 60 µm
Height resolution 1 - 2 µm
Repeatability 2% (10 readings on structure reference standard)
Reproducibility 5% (on structure reference standard)
General Data
Memory 3000 samples with images
10 000 samples without images
Languages English, German, French, Italian, Spanish, Russian,
Japanese, Chinese
Dimensions (LxWxH) 150 x 240 x 155 mm (5.9 × 9.5 × 6.1 in)
Weight 1530 g (3.37 lbs)
Interface USB Type-C (USB 3.1)
Battery 7.2 V; 2350 mAh; 16.92 Wh
Power supply Input: 5 V - 12 V ; max. 3.0 A
External
power supply Input: 100 - 240 V ; 50 - 60 Hz; max. 1.0 A
Output: 5 V ; max. 2.1 A
Vendor: Sunny
Modell: SYS1561-1105-W
Safety approvals: CB / CE / GS / FCC / cU-Lus / CCC / BSMI / PSE /
KC / SAA / RCM / EAC / S-MARK
Temperature
range
Operation: 10° C to 40° C (50° F to 104° F)
Storage: 0° C to 60° C (32° F to 140° F)
Relative humidity Up to 85 % at 35° C (95° F) non-condensing
Operating altitude Up to 2000 m (6561 feet)
Password for reset byk-instruments
Technical data are subject to change without notice.

spectro2profiler BYK-Gardner GmbH
14 283 025 449 - 2305
Inhaltsverzeichnis
1 Systembeschreibung................................................................................................................... 15
2 Software Installation.................................................................................................................. 16
3 Hauptmenü .................................................................................................................................. 17
4 Messparameter............................................................................................................................ 18
5 Kalibrierung................................................................................................................................. 19
6 Differenzmessung ....................................................................................................................... 20
7 Absolutmessung und Quickcheck .............................................................................................. 21
8 Technische Daten ........................................................................................................................ 22

BYK-Gardner GmbH spectro2profiler
283 025 449 - 2305 15
1 Systembeschreibung
Das System besteht aus Messgerät, Kalibrier- und Test-Standards und Software für Daten-
transfer und -analyse.
• Gerät (1) über das USB-Kabel mit dem PC verbinden (2).
• Mit dem erstmaligen Verbinden schaltet sich das Gerät automatisch ein.
• Die Li-Ionen-Batterie im Gerät (1) wird automatisch aufgeladen (2).
• Falls sich das Gerät abgeschaltet hat, kann es mit der Taste Operate eingeschaltet
werden.
• Software smart-chart herunterladen und installieren (3).

spectro2profiler BYK-Gardner GmbH
16 283 025 449 - 2305
2 Software Installation
1. ZIP-Datei herunterladen von:
https://www.byk-instruments.com/spectro2profiler
2. Datei in einem neuen Ordner speichern und das ZIP-Archiv komplett entpacken.
3. Mit der rechten Maus-Taste auf “install.exe” klicken und die Option “Als Adminis-
trator ausführen” wählen.
4. Den Installationsanweisungen auf dem Bildschirm folgen.
Die Software umfasst zwei Pakete:
•smart-lab für Online-Messungen und Datenübertragung zum PC
•smart-process für standardisierte Qualitätskontrollen in der Produktion
HINWEIS:
Nach erfolgter Installation können smart-lab und smart-process zum freien Test 30 Ta-
ge lang verwendet werden. Danach muss eines der beiden Software-Pakete registriert
werden.

BYK-Gardner GmbH spectro2profiler
283 025 449 - 2305 17
3 Hauptmenü
Die folgenden Symbole werden standardmäßig angezeigt.
12
3
4 5
1Differenz
Standard und Probe vergleichen. Er-
gebnisse werden automatisch ge-
speichert.
2Absolut
Absolutmessung ohne Standard
durchführen. Ergebnisse werden au-
tomatisch gespeichert.
3Quick-Check
Schneller Vergleich, ohne Messwerte
zu speichern.
4Datenansicht
Anzeigen und Löschen von Messda-
ten.
5Einstellungen
Messparameter oder Geräteeinstellungen ändern und Gerät kalibrieren.
Anzeige weiterer Symbole
Deckkraft
Aktivieren unter Einstellungen > Messparameter > Farbindizes.
Organizer
Erscheint nach dem Download eines Organizers aus smart-chart.

spectro2profiler BYK-Gardner GmbH
18 283 025 449 - 2305
4 Messparameter
Einstellungen > Messparameter auswählen.
2D/3D-Einstellungen: Algorithmus für die
Messung wählen - Leather-Like, Leather-
Inverted, Coarse Paint, Fine. Details sie-
he separates Glossar.
Glanz: Glanzmessung und / oder Differenz-
messung für Glanz ein- oder ausschalten.
2D/3D-Skalen: Auswahl der zu messenden
Skalen für die 2D-Reflexion und 3D-Struk-
turanalyse.
Lichtart: Auswahl der Normlichtart. Vor-
eingestellt ist D65.
Farbsystem: Auswahl des Farbsystems.
Voreingestellt ist CIE L*a*b*.
Beobachter: Auswahl des Standardbeob-
achters. Voreingestellt ist 10°.
Differenzmethode: Auswahl der Diffe-
renzmethode. Voreingestellt ist ∆E*.
Statistik: Anzahl der Messwerte (n) und
anzuzeigende statistische Werte festlegen,
Option Statistik fest aktivieren / deaktivie-
ren (nicht mehr Messwerte als (n) sind
möglich).
Messbildschirm: Auswahl der Werte, die
nach einer Messung angezeigt werden sol-
len. Voreingestellt ist ∆SMP (Differenz der
Probe zum Standard).
Immer Autostandard verwenden: Die
Suche nach dem nächstgelegenen Standard
ist stets aktiviert.
Farbindizes: Auswahl der Farbindizes.
Voreingestellt ist Keiner.
Letzte Testserie fortsetzen: Es wird kei-
ne neue Testserie angelegt; die letzte Test-
serie wird automatisch geöffnet.

BYK-Gardner GmbH spectro2profiler
283 025 449 - 2305 19
5 Kalibrierung
Die Lieferung umfasst einen Kalibrierstandard und je einen Teststandard für Farbe und für
Glanz. Jeder Teststandard hat eine Seriennummer, die zum Gerät passt. Mit diesen Kacheln
prüfen, ob das Gerät korrekt misst. Das Gerät führt durch die Prüfung.
1. Standards und Gerät auf einer stabilen Unterlage verwenden.
2. Auf Einstellungen > Kalibrierung > Autodiagnose durchführen tippen.
3. Gerät auf grünen Farbstandard setzen und ruhig halten.
4. Mit Häkchen bestätigen oder Taste Operate drücken.
5. Bei erfolgreicher Diagnose mit schwarzem Glanzstandard fortfahren.
6. Bei erfolgreicher Diagnose Gerät zum Messen verwenden.
7. Schlägt Diagnose fehl, Standard reinigen und Vorgang wiederholen.
8. Schlägt Diagnose fehl, auf Kalibriere tippen und den Anweisungen folgen.
Nach Ablauf des Intervalls der automatischen Diagnose (4 Wochen) zeigt das Gerät beim
Einschalten eine Meldung an.
HINWEIS
Zur Prüfmittelüberwachung: Auf Als Standard hinzufügen tippen, um einen Teststan-
dard im Gerät zu speichern. Diesen Standard in regelmäßigen Intervallen messen.

spectro2profiler BYK-Gardner GmbH
20 283 025 449 - 2305
6 Differenzmessung
Nach passenden Standards suchen, neue Standards anlegen und Proben mit Standards ver-
gleichen. Die Ergebnisse werden automatisch gespeichert.
1
23
4
5
6
7
1. Bestehenden Standard wählen (1) oder neuen Standard anlegen.
2. Zum Anlegen eines neuen Standards auf das Plus-Symbol + (2) tippen.
3. Messgerät auf dem Standard positionieren.
4. Zum Aktivieren der Kamera die Taste Operate halb drücken.
5. Auf Messen (3) tippen oder die Taste Operate durchdrücken.
6. Standard wird gemessen und automatisch gespeichert.
7. Nach unten scrollen, um Mess- und Statistikdaten zu sehen.
4
5
6
7
8. Nach nötiger Anzahl an Messungen (4) weiter mit Nächste (5).
9. Messgerät auf die erste Probe stellen und messen.
10. Probe wird gemessen und gespeichert, weiter zur nächsten Probe (6).
Table of contents
Languages:
Other BYK Measuring Instrument manuals

BYK
BYK haze-gard plus Instruction Manual

BYK
BYK micro-gloss Installation manual

BYK
BYK micro-TRI-gloss ? User manual

BYK
BYK spectro2guide User manual

BYK
BYK CAP 1000+ User manual

BYK
BYK LC 4 User manual

BYK
BYK LC 3 User manual

BYK
BYK multi-angle User manual

BYK
BYK LCM III User manual

BYK
BYK haze-gard plus User manual
Popular Measuring Instrument manuals by other brands

Scott
Scott Protege SG user guide

MICRO-EPSILON
MICRO-EPSILON capaNCDT 6200 Quick manual

VOLTCRAFT
VOLTCRAFT VC-533 AC/DC operating instructions

Kurth Electronic
Kurth Electronic KE401 IT quick start guide

Vaisala
Vaisala WA252 quick guide

Krautkramer
Krautkramer DynaPOCKET Technical Reference and Operating Manual